Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Improved generation of ion fluxes by a long laser pulse using laser-induced cavity pressure acceleration

Generation of ion fluxes in the laser-induced cavity pressure acceleration (LICPA) scheme is investigated by the time-of-flight method and compared with the one in the conventional laser-planar target interaction scheme. It is shown that the ion current density and intensity of the ion flux produced in the LICPA scheme from CD{sub 2} foil target irradiated by a 0.3-ns laser pulse of intensity ∼10{sup 14}–10{sup 15} W/cm{sup 2} are by an order of magnitude higher and the mean and maximum ion energies by a factor 4–5 higher than those for the conventional scheme.

36 MATERIALS SCIENCE↗

Highly efficient generation of ultraintense high-energy ion beams using laser-induced cavity pressure acceleration

Results of particle-in-cell (PIC) simulations of fast ion generation in the recently proposed laser-induced cavity pressure acceleration (LICPA) scheme in which a picosecond circularly polarized laser pulse of intensity {approx}10{sup 21} W/cm{sup 2} irradiates a carbon target placed in a cavity are presented. It is shown that due to circulation of the laser pulse in the cavity, the laser-ions energy conversion efficiency in the LICPA scheme is more than twice as high as that for the conventional (without a cavity) radiation pressure acceleration scheme and a quasi-monoenergetic carbon ion beam of the mean ion energy {approx}0.5 GeV and the energy fluence {approx}0.5 GJ/cm{sup 2} is produced with the efficiency {approx}40%. The results of PIC simulations are found to be in fairly good agreement with the predictions of the generalized light-sail model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3rd harmonic magnetometry assessment of NbTiN-based SIS structures

In the quest for alternative superconducting materials to bring accelerator cavity performance beyond the bulk niobium (Nb) intrinsic limits, a promising concept proposes that superconductor-insulator-superconductor (SIS) thin film structures can delay magnetic flux penetration in accelerator cavities to higher fields [1]. NbTiN is a candidate superconductor for such structures. We have demonstrated high quality NbTiN and AlN deposited by reactive direct current magnetron sputtering (DCMS), both for individual layers and multilayers. Interface quality has been assessed for bi-layer stacks with various NbTiN and AlN thicknesses from 500 and 30 nm down to 3 and 1 nm. These SIS structures show continued sharp interfaces. The Hfp enhancement of the films was examined with 3rd harmonic magnetometry. The system was designed and built in an ongoing collaboration with CEA Saclay. It can measure 1? to 2? samples on a temperature controlled stage. This contribution presents the assessment of the first penetration field enhancement with 3rd harmonic magnetometry for standalone films and multilayer nanostructures.

Valente, Anne-Marie↗

Application of International Linear Collider superconducting cavities for acceleration of protons.

Beam acceleration in the International Linear Collider (ILC) will be provided by 9-cell 1300 MHz superconducting (SC) cavities. The cavities are designed for effective acceleration of charged particles moving with the speed of light and are operated on p-mode to provide a maximum accelerating gradient. A significant research and development effort has been devoted to develop ILC SC technology and its rf system which resulted in excellent performance of ILC cavities. Therefore, the proposed 8-GeV proton driver in Fermilab is based on ILC cavities above {approx}1.2 GeV. The efficiency of proton beam acceleration by ILC cavities drops fast for lower velocities and it was proposed to develop squeezed ILC-type (S-ILC) cavities operating at 1300 MHz and designed for {beta}G=0.81, geometrical beta, to accelerate protons or H{sup -} from {approx}420MeV to 1.2 GeV. This paper discusses the possibility of avoiding the development of new {beta}G=0.81 cavities by operating ILC cavities on 8 / 9{pi}-mode of standing wave oscillations.

43 PARTICLE ACCELERATORS↗

Two-beam detuned-cavity electron accelerator structure

Progress has been made in the theory, development, cavity design and optimization, beam dynamics study, beam transport design, and hardware construction for studies of a detuned two-beam electron accelerator structure.

43 PARTICLE ACCELERATORS↗

Generation of ultra-high-pressure shocks by collision of a fast plasma projectile driven in the laser-induced cavity pressure acceleration scheme with a solid target

A novel, efficient method of generating ultra-high-pressure shocks is proposed and investigated. In this method, the shock is generated by collision of a fast plasma projectile (a macro-particle) driven by laser-induced cavity pressure acceleration (LICPA) with a solid target placed at the LICPA accelerator channel exit. Using the measurements performed at the kilojoule PALS laser facility and two-dimensional hydrodynamic simulations, it is shown that the shock pressure ∼ Gbar can be produced with this method at the laser driver energy of only a few hundred joules, by an order of magnitude lower than the energy needed for production of such pressure with other laser-based methods known so far.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenic testing of the 2.1 GHz five-cell superconducting RF cavity with a photonic band gap coupler cell

We present results from cryogenic tests of the multi-cell superconducting radio frequency (SRF) cavity with a photonic band gap (PBG) coupler cell. Achieving high average beam currents is particularly desirable for future light sources and particle colliders based on SRF energy-recovery-linacs (ERLs). Beam current in ERLs is limited by the beam break-up instability, caused by parasitic higher order modes (HOMs) interacting with the beam in accelerating cavities. A PBG cell incorporated in an accelerating cavity can reduce the negative effect of HOMs by providing a frequency selective damping mechanism, thus allowing significantly higher beam currents. The multi-cell cavity was designed and fabricated of niobium. Two cryogenic (vertical) tests were conducted. The high unloaded Q-factor was demonstrated at a temperature of 4.2 K at accelerating gradients up to 3 MV/m. The measured value of the unloaded Q-factor was 1.55 × 10 8 , in agreement with prediction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cavity pressure acceleration: An efficient laser-based method of production of high-velocity macroparticles

We propose an efficient method of accelerating macroparticles to high velocities, which employs pressure of the plasma produced by a focused pulsed high-power laser beam inside a cavity-type target. That is why we have called it the cavity pressure acceleration (CPA) scheme. The method was tested during our experiments at the Prague Asterix Laser System, the results of which are reported here. They show that CPA makes it possible to accelerate both light and heavy macroparticles in arbitrary direction, with the acceleration efficiency far exceeding that achieved upto now by using the classic ablative acceleration scheme. High velocities of the macroparticles (foil fragments) produced and possibility of accelerating even rather heavy macroparticles are promising from the point of view of impact fusion studies, of the impact fast ignition, in particular.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The design of a simulated in-line side-coupled 6 MV linear accelerator waveguide

Purpose: The design of a 3D in-line side-coupled 6 MV linac waveguide for medical use is given, and the effect of the side-coupling and port irises on the radio frequency (RF), beam dynamics, and dosimetric solutions is examined. This work was motivated by our research on a linac-MR hybrid system, where accurate electron trajectory information for a clinical medical waveguide in the presence of an external magnetic field was needed. Methods: For this work, the design of the linac waveguide was generated using the finite element method. The design outlined here incorporates the necessary geometric changes needed to incorporate a full-end accelerating cavity with a single-coupling iris, a waveguide-cavity coupling port iris that allows power transfer into the waveguide from the magnetron, as well as a method to control the RF field magnitude within the first half accelerating cavity into which the electrons from the gun are injected. Results: With the full waveguide designed to resonate at 2998.5{+-}0.1 MHz, a full 3D RF field solution was obtained. The accuracy of the 3D RF field solution was estimated through a comparison of important linac parameters (Q factor, shunt impedance, transit time factor, and resonant frequency) calculated for one accelerating cavity with the benchmarked program SUPERFISH. It was found that the maximum difference between the 3D solution and SUPERFISH was less than 0.03%. The eigenvalue solver, which determines the resonant frequencies of the 3D side-coupled waveguide simulation, was shown to be highly accurate through a comparison with lumped circuit theory. Two different waveguide geometries were examined, one incorporating a 0.5 mm first side cavity shift and another with a 1.5 mm first side cavity shift. The asymmetrically placed side-coupling irises and the port iris for both models were shown to introduce asymmetries in the RF field large enough to cause a peak shift and skewing (center of gravity minus peak shift) of an initially cylindrically uniform electron beam accelerating within the waveguide. The shifting and skewing of the electron beam were found to be greatest due to the effects of the side-coupling irises on the RF field. A further Monte Carlo study showed that this effect translated into a 1% asymmetry in a 40x40 cm{sup 2} field dose profile. Conclusions: A full 3D design for an in-line side-coupled 6 MV linear accelerator that emulates a common commercial waveguide has been given. The effect of the side coupling on the dose distribution has been shown to create a slight asymmetry, but overall does not affect the clinical applicability of the linac. The 3D in-line side-coupled linac model further provides a tool for the investigation of linac performance within an external magnetic field, which exists in an integrated linac-MR system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of Multipacting with Space Charge Effect

Here, the electron multiplication on surfaces exposed to an oscillating electromagnetic field causes the phenomenon of multipacting, which can degrade significantly the performance of vacuum RF devices, especially accelerating cavities. It is a serious obstacle to be avoided for normal operation of particle accelerator and their RF components. Many types of room temperature and superconducting accelerating cavities are designed and produced at Fermilab for different projects. The extensive simulations of multipacting in the cavities with updated material properties and comparison of the simulation results with experimental data are routinely performed during electromagnetic design of the cavities. The new advanced computing capabilities made it possible to take the space charge effect into account in the multipacting simulations. The basic new features of multipacting process that appear due to the space charge effect are shown for the classic case of the parallel plates and discussed. As the first practical application of the multipacting simulations with space charge effect the study of multipacting in the low-beta and high-beta 650 MHz elliptical superconducting cavities is also presented.

43 PARTICLE ACCELERATORS↗

Investigations on the multiple-sector hard-copper X-band accelerating structures

The development of advanced, high gradient accelerating structures is one of the leading activity of the particle accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for the verification of their viability. Recent experiments showed that accelerating cavities made out of hard copper, fabricated without high-temperature processes, can achieve better performance as compared with soft copper ones. Recently, we have built cavities using Tungsten Inert Gas welding and the high-power experiments confirmed that this joining process is a robust and low-cost alternative to brazing or diffusion bonding. This is a good solution for high-gradient operation, with a gradient of about 150 MV/m in X-band, at a breakdown rate of 10 -3 /pulse/meter using a shaped RF pulse with a 150 ns flat part. We continue the design, construction and high power tests of three-cells standing-wave X-band accelerating cavities fabricated with a split-open geometry, made of hard copper and vacuum-sealed by welding. Our aim is the fabrication of accelerating structures made out of hard copper alloys by using innovative cost-effective technologies. Moreover, our method of multiple-sector structures opens the way to new technological approaches and design methods, for example providing the possibility of placing dampers of the parasitic higher-order modes. Such structures with dampers allow for acceleration of multi-bunch beams, both in standing and in travelling-wave accelerating modality. Here, this paper describes the design of two cavities made of multiple sectors that were fabricated at the Italian Institute for Nuclear Physics in Frascati, Italy (INFN-LNF), assembled by means of clamping and then joined with the Tungsten Inert Gas welding in order to preserve the hardness of the metal. These are three-cell standing-wave X-band accelerating cavities, to be operated in the π-mode. We report the low-power RF tests of the first one, made of two halves, and the RF design of the second one, made of four quadrants. Both structures were built for high-gradient tests at SLAC National Accelerator Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics of Limiting Phenomena in Superconducting Microwave Resonators: Vortex Dissipation, Ultimate Quench and Quality Factor Degradation Mechanisms

Superconducting niobium accelerating cavities are devices operating in radio-frequency and able to accelerate charged particles up to energy of tera-electron-volts. Such accelerating structures are though limited in terms of quality factor and accelerating gradient, that translates--in some cases--in higher capital costs of construction and operation of superconducting rf accelerators. Looking forward for a new generation of more affordable accelerators, the physical description of limiting mechanisms in superconducting microwave resonators is discussed. In particular, the physics behind the dissipation introduced by vortices in the superconductor, the ultimate quench limitations and the quality factor degradation mechanism after a quench are described in detail. One of the limiting factor of the quality factor is the dissipation introduced by trapped magnetic flux vortices. The radio-frequency complex response of trapped vortices in superconductors is derived by solving the motion equation for a magnetic flux line, assuming a bi-dimensional and mean free path-dependent Lorentzian-shaped pinning potential. The resulting surface resistance shows the bell-shaped trend as a function of the mean free path, in agreement with the experimental data observed. Such bell-shaped trend of the surface resistance is described in terms of the interplay of the two limiting regimes identified as pinning and flux flow regimes, for low and large mean free path values respectively. The model predicts that the dissipation regime--pinning- or flux-flow-dominated--can be tuned either by acting on the frequency or on the electron mean free path value. The effect of different configurations of pinning sites and strength on the vortex surface resistance are also discussed. Accelerating cavities are also limited by the quench of the superconductive state, which limits the maximum accelerating gradient achievable. The accelerating field limiting factor is usually associate d to the superheating field, which is intimately correlated to the penetration of magnetic flux vortices in the material. Experimental data for N-doped cavities suggest that uniform Ginzburg-Landau parameter cavities are statistically limited by the lower critical field, in terms of accelerating gradient. By introducing a Ginzburg-Landau parameter profile at the cavity rf surface--dirty layer--the accelerating gradient of superconducting resonators can be enhanced. The description of the physics behind the accelerating gradient enhancement as a consequence of the dirty layer is carried out by solving numerically the Ginzburg-Landau equations for the layered system. The enhancement is showed to be promoted by the higher energy barrier to vortex penetration, and by the enhanced lower critical field. Another serious threat to the quality factor during the cavity operation is the extra dissipation introduced by the quench. Such quality factor degradation mechanism due to the quench, is generated by the trapping of external magnetic flux at quench spot. The purely extrinsic origin of such extra dissipation is proven by the impossibility of decrease the quality factor by quenching in a magnetic field-free environment. Also, a clear relation of the dissipation introduced by quenching to the orientation of the applied magnetic field is observed. The full recover of the quality factor by re-quenching in compensated field is possible when the trapped flux at the quench spot is modest. On the contrary, when the trapped magnetic flux is too large, the quality factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during the quench.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics of Limiting Phenomena in Superconducting Microwave Resonators: Vortex Dissipation, Ultimate Quench and Quality Factor Degradation Mechanisms

Superconducting niobium accelerating cavities are devices operating in radio-frequency and able to accelerate charged particles up to energy of tera-electron-volts. Such accelerating structures are though limited in terms of quality factor and accelerating gradient, that translates--in some cases--in higher capital costs of construction and operation of superconducting rf accelerators. Looking forward for a new generation of more affordable accelerators, the physical description of limiting mechanisms in superconducting microwave resonators is discussed. In particular, the physics behind the dissipation introduced by vortices in the superconductor, the ultimate quench limitations and the quality factor degradation mechanism after a quench are described in detail. One of the limiting factor of the quality factor is the dissipation introduced by trapped magnetic flux vortices. The radio-frequency complex response of trapped vortices in superconductors is derived by solving the motion equation for a magnetic flux line, assuming a bi-dimensional and mean free path-dependent Lorentzian-shaped pinning potential. The resulting surface resistance shows the bell-shaped trend as a function of the mean free path, in agreement with the experimental data observed. Such bell-shaped trend of the surface resistance is described in terms of the interplay of the two limiting regimes identified as pinning and flux flow regimes, for low and large mean free path values respectively. The model predicts that the dissipation regime--pinning- or flux-flow-dominated--can be tuned either by acting on the frequency or on the electron mean free path value. The effect of different configurations of pinning sites and strength on the vortex surface resistance are also discussed. Accelerating cavities are also limited by the quench of the superconductive state, which limits the maximum accelerating gradient achievable. The accelerating field limiting factor is usually associate d to the superheating field, which is intimately correlated to the penetration of magnetic flux vortices in the material. Experimental data for N-doped cavities suggest that uniform Ginzburg-Landau parameter cavities are statistically limited by the lower critical field, in terms of accelerating gradient. By introducing a Ginzburg-Landau parameter profile at the cavity rf surface--dirty layer--the accelerating gradient of superconducting resonators can be enhanced. The description of the physics behind the accelerating gradient enhancement as a consequence of the dirty layer is carried out by solving numerically the Ginzburg-Landau equations for the layered system. The enhancement is showed to be promoted by the higher energy barrier to vortex penetration, and by the enhanced lower critical field. Another serious threat to the quality factor during the cavity operation is the extra dissipation introduced by the quench. Such quality factor degradation mechanism due to the quench, is generated by the trapping of external magnetic flux at quench spot. The purely extrinsic origin of such extra dissipation is proven by the impossibility of decrease the quality factor by quenching in a magnetic field-free environment. Also, a clear relation of the dissipation introduced by quenching to the orientation of the applied magnetic field is observed. The full recover of the quality factor by re-quenching in compensated field is possible when the trapped flux at the quench spot is modest. On the contrary, when the trapped magnetic flux is too large, the quality factor degradation may become irreversible by this technique, likely due to the outward flux migration beyond the normal zone opening during the quench.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetron-driven microton-injector of a terahertz free electron laser

A magnetron-driven microtron injector has been developed for a terahertz free electron laser (FEL). An internal injection system was chosen for the microtron to achieve a compact and inexpensive design. The system provides acceleration of electrons with low emittance and energy spread that is highly important for the FEL. However, the intrapulse instabilities of the accelerated current and the bunch repetition rate inherent to the injection system make problems for the FEL operation. Simulations of the beam dynamics and the transient process allow one to compute the load characteristic of the accelerating cavity and the time-dependent accelerated current. The simulation techniques also allow one to calculate time-dependent deviations of the magnetron frequency in the coupled system of the accelerating and magnetron cavities, as well as deviations in the bunch repetition rate. The computations validate proposed concepts for increasing the intrapulse current stability with appropriate time-dependent variation of the magnetron power and decreasing the bunch repetition rate instability through a simple microwave scheme utilizing the microtron accelerating cavity concurrently as an external stabilizing resonator for the magnetron. The realized concepts and optimization of the microtron regimes using the simulated phase motion of the accelerated bunch provide stable operation of the terahertz FEL, tunable in the range of 1-3 THz with extracted macropulse power up to 50 Watts at the macropulse energy of -0.2 mJ.

43 PARTICLE ACCELERATORS↗

Superconducting accelerating structures for very low velocity ion beams.

This paper presents designs for four types of very-low-velocity superconducting (SC) accelerating cavity capable of providing several MV of accelerating potential per cavity, and suitable for particle velocities in the range 0.006<v/c<0.06. Superconducting TEM-class cavities have been widely applied to cw acceleration of ion beams. SC linacs can be formed as an array of independently phased cavities, enabling a variable velocity profile to maximize the output energy for each of a number of different ion species. Several laboratories in the U.S. and Europe are planning exotic beam facilities based on SC linacs. The cavity designs presented here are intended for the front end of such linacs, particularly for the postacceleration of rare isotopes of low charge state. Several types of SC cavities have been developed recently to cover particle velocities above 0.06c. Superconducting four-gap quarter-wave resonators for velocities 0.008<{beta}=v/c<0.05 were developed about two decades ago and have been successfully operated at the ATLAS SC linac at Argonne National Laboratory. Since that time, progress in simulation tools, cavity fabrication, and processing have increased SC cavity gradients by a factor of 3-4. This paper applies these tools to optimize the design of a four-gap quarter-wave resonator for exotic beam facilities and other low-velocity applications.

43 PARTICLE ACCELERATORS↗

FLUKA Analysis of Linac Fault Study Dose Rates

The planned Linac Fault Study was conducted on December 5 and 6, 2013 according to the Fault Study Procedure. Beam energy out the end of the Linac was typically 200 MeV, except for the LB-B1 Fault study that used 100 MeV beam out of the 4 th accelerator cavity (ACC4, also called and labeled as 4 th accelerating structure, AS4). The Linac fault study where beam was steered into the 4 th accelerator cavity (upstream) had beam energy of 150 MeV, since the last cavity was not traversed. Table I describes the list of the Beam Loss Fault Studies generated for verification of the Linac tunnel bulk and Linac supplemental shield effectiveness. The beam charge for the loss locations was typically measured at the LB-IT1 integrating current monitor after the ACC4 cavity, between LB-Q1 and LB-Q2. If beam was transported to the dumps a Faraday cup (LB-DU1 or LBDU2) monitor will yield the transported current to the dump, with the difference between LB-IT1 and LB-DU1 yielding the charge lost ahead of the dump. For beam miss-steered or intercepted ahead of the dumps the transport efficiency is zero. For the ACC4 beam loss fault the assumed current was the LB-ITI value before the miss-steering. For most of the faults the LB-ITI current was reading ~13.4 nC and the pulse rate was 1Hz, for 13.4 nC/s beam current.

36 MATERIALS SCIENCE↗