Search NASA⌕ Search

SEARCH · Search NASA

Results for “active filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cleaner Air for Home and Office

Increased insulation has led to higher concentrations in homes and offices of toxic chemicals caused by emissions from synthetic building components. Recent NASA research regarding future interplanetary manned spacecraft has shown that certain plants can absorb gasses, reducing indoor air pollution. After working with water purifying water hyacinths, Dr. B. C. Wolverton at NSTL developed a carbon/plant filter system to remove chemicals, smoke, etc. Two companies have commercialized the system. Bio-safe provides plants, a bed of activated carbon and an air pump installed near the plant's roots. Pollutants are trapped by the charcoal and either digested by the roots or broken down by microorganisms. Purified air is then directed back into the room. Applied Indoor Resource Company markets Bio-Pure, which includes plants on a layer of patented soil medium with activated carbon. Legumes and mosses filter the air; a blower moves air through the filtering system for cleansing by microorganisms. Research at NSTL continues, and the system may eventually be enlarged.

Source record↗

Extracting lignins from mill wastes

Addition of quaternary ammonium compound and activated charcoal to pulp and mill wastes precipitates lignins in sludge mixture. Methanol dissolves lignins for separation from resulting slurry. Mineral acid reprecipitates lignins in filtered solution. Quaternary ammonium compound, activated charcoal, as well as water may be recovered and recycled from this process.

Humphrey, M. F.↗

Chromatic Modulator for High Resolution CCD or APS Devices

A system for providing high-resolution color separation in electronic imaging. Comb drives controllably oscillate a red-green-blue (RGB) color strip filter system (or otherwise) over an electronic imaging system such as a charge-coupled device (CCD) or active pixel sensor (APS). The color filter is modulated over the imaging array at a rate three or more times the frame rate of the imaging array. In so doing, the underlying active imaging elements are then able to detect separate color-separated images, which are then combined to provide a color-accurate frame which is then recorded as the representation of the recorded image. High pixel resolution is maintained. Registration is obtained between the color strip filter and the underlying imaging array through the use of electrostatic comb drives in conjunction with a spring suspension system.

Frank T Hartley↗

The NASA Phoenix 2007 Mars Lander Thruster Calibration Estimator: Design and Validation

The NASA Phoenix 2007 Mars Lander mission, launched in August 2007 on its mission to land near the north pole of Mars in May 2008, had a driving need for entry-corridor delivery precision, which parlayed into stringent requirements on deep space navigation accuracy. This, in turn, necessitated in-cruise calibration of the three-axis thrust force vectors produced by each of the vehicle's four reactioncontrol system (RCS) thrusters during frequent daily low-catalyst-bed-temperature firings done to maintain the 3-axis attitude deadbands. A novel recursive sigmapoint consider-covariance filter was designed, validated and ultimately utilized extensively during flight operations, to estimate the RCS force vectors, per individual thruster. The estimate was achieved through ground-based processing of Deep Space Network (DSN) and telemetered gyroscope data from the spacecraft's inertial measurement unit (IMU), using a novel sigma-point consider filter (SPCF) formulation. During early-cruise active calibration, the spacecraft was flown in attitudes chosen, using this filter, to maximize observability of all thruster axes, to an extent constrained by vehicle thermal and communication considerations. The design of the Phoenix thruster calibration filter, and its validation through processing of archived Mars Odyssey thruster calibration radiometric data, and simulated sets of data, are discussed in this paper. The paper concludes with the formulation of the thruster calibration campaign and a summary of the thruster calibration campaign results. The SPCF algorithm is summarized in the Appendix.

sigma-point filter↗

Solar wind control of auroral zone geomagnetic activity

Solar wind magnetosphere energy coupling functions are analyzed using linear prediction filtering with 2.5 minute data. The relationship of auroral zone geomagnetic activity to solar wind power input functions are examined, and a least squares prediction filter, or impulse response function is designed from the data. Computed impulse response functions are observed to have characteristics of a low pass filter with time delay. The AL index is found well related to solar wind energy functions, although the AU index shows a poor relationship. High frequency variations of auroral indices and substorm expansions are not predictable with solar wind information alone, suggesting influence by internal magnetospheric processes. Finally, the epsilon parameter shows a poorer relationship with auroral geomagnetic activity than a power parameter, having a VBs solar wind dependency.

Clauer, C. R.↗

Tunable mid-wave infrared spectral filters based on GexSbyTez for multispectral imaging

The mid-wave infrared (MWIR) spectrum contains a wealth of invaluable information including the spectral ‘fingerprint’ of many chemical species and has applications in remote sensing and astronomical imaging. Traditionally, filtering for the MWIR is achieved by means of passive multilayer interference (dichroic) filters, Fabry-Perot-based micro-electro-mechanical system (MEMS) filters, liquid crystal tunable filters, and focal plane array (FPA) filters. For accurate multispectral imaging applications, these approaches suffer from various limitations such as: having moving parts; exhibiting slow response times, and; having limited spectral bandwidth / resolution. Recently, there has been significant interest toward ‘active’ spectral imaging technologies, whereby the ability to provide electrically tunable narrowband filtering—spanning the entire MWIR—is highly desirable. In this work we introduce a new spectral imaging technology, namely actively tunable optical transmission filters using the phase-change material (PCM) GexSbyTez (GST). The GST exhibits a large, reversible change in its refractive index across the MWIR upon a phase transition (from amorphous to crystalline). This refractive index modulation governs the filter’s optical characteristics. Through an optical stimulus or applied voltage—which changes the GST state from amorphous to crystalline—one can actively tune the filter with MHz speed. We incorporate GST into optimized guided mode resonance (GMR) and plasmonic nanohole array (PNA) device architectures, enabling <10nm spectral resolution and tunable operation across 3~5µm. Our proposed PCM-MWIR filter will be able to extract the maximum amount of ‘useful’ information within the atmosphere for remote Earth sensing measurements at operational speeds orders of magnitude faster than current airborne-based sensors. Moreover, it may enable affordable SmallSat-based MWIR instrumentation which is complimentary to other observation systems. The MISSE (Materials International Space Station Experiment-Flight Facility) experiment has been proposed as a testbed for a PCM-based tunable MWIR filter module to allow exposure of the module to the low Earth orbit space environment. This will provide valuable data regarding the robustness of the filter to withstand the radiation and atomic oxygen environment and allow assessment of the technology for use in space applications.

Kim, Hyun Jung↗

Acousto-optic tunable filter multispectral imaging system

This paper discusses recent activities of Jet Propulsion Laboratory in the development of a new type of remote sensing multispectral imaging instruments using acousto-optic tunable filter (AOTF) as programmable bandpass filter. This remote sensor provides real-time operation; observational flexibility; measurements of spectral, spatial, and polarization information using a single instrument; and compact, solid state structure without moving parts. Two microcomputer-controlled AOTF imaging spectrometer breadboard systems were designed and built. One operates in the wavelength range of 0.48-0.76 micron and the other in the range of 1.2-2.5 micron. Experiments were performed using these two systems to observe geological and botanical objects in laboratory and outdoor environment. Results have demonstrated the feasibility of using the AOTF multispectral imaging system as a real-time versatile remote sensor with operational flexibility for future Army tactical applications.

Cheng, Li-Jen↗

Experiments on active isolation using distributed PVDF error sensors

A control system based on a two-channel narrow-band LMS algorithm is used to isolate periodic vibration at low frequencies on a structure composed of a rigid top plate mounted on a flexible receiving plate. The control performance of distributed PVDF error sensors and accelerometer point sensors is compared. For both sensors, high levels of global reduction, up to 32 dB, have been obtained. It is found that, by driving the PVDF strip output voltage to zero, the controller may force the structure to vibrate so that the integration of the strain under the length of the PVDF strip is zero. This ability of the PVDF sensors to act as spatial filters is especially relevant in active control of sound radiation. It is concluded that the PVDF sensors are flexible, nonfragile, and inexpensive and can be used as strain sensors for active control applications of vibration isolation and sound radiation.

Lefebvre, S.↗

Establishing and Monitoring an Aseptic Workspace

When are aseptic operations necessary? In order to meet certain bioburden requirements, some components must undergo dry heat microbial reduction (DHMR) or other sterilizing procedures. If sensitive surfaces must be re-exposed after DHMR, this could compromise the bioburden levels. Recontaminating sterilized surfaces could be costly both in time by requiring repeated DHMR and risk to the hardware, which may not be compatible with repeated high temperature bakes. In order to prevent recontamination of the sensitive surfaces, an aseptic environment and sterile technique must be employed. Aseptic environments mean working in a space with almost no detectable bioburden in the air or on surfaces. Ideally, DHMR happens as late as possible to avoid requiring aseptic operations, as it can be considered a high-risk operations. Preparing the cleanroom for aseptic operations Establishing an ISO (International Organization for Standardization) class 5 space to minimize airborne particles. Maintain low bioburden in the cleanroom by using biocidal cleaners. Using multiple biocidal techniques decreases the likelihood of selecting for resistant microorganisms. 70% Isopropyl Alcohol (IPA) denatures the proteins in a microorganism (note: 70% IPA is better at killing microorganisms than 100% IPA) 7% hydrogen peroxide: damages DNA and proteins through oxygen radical damage. Ultraviolet-C (UV-C) lamps: causes crosslinking in DNA which prevents replication. Monitor cleanroom regularly for bioburden trending: Standard bioassay: Swab or wipe samples of cleanroom surfaces processed for colony forming unity (viable or spore selected); Rapid bioassay: Adenosine triphosphate (ATP) or Limulus amebocyte lysate (LAL) for a bioburden snapshot. High levels can signal an immediate re-cleaning before standard bioassay samples are taken. Airborne monitoring: Active (pulling air through a filter) or passive (particle fallout) for bioburden. Verify bioburden levels just before aseptic operation. Test hardware and cleanroom surfaces and air 3 days before the planned aseptic operation. Rapid bioburden just before aseptic operation to ensure room was not re-contaminated. Preparing personnel and tools: Personnel training. Everyone in the cleanroom: Standard cleanroom certification Everyone on the team: 1 day Planetary Protection overview. Aseptic operators only: Half-day aseptic operations training. Covers sterile garmenting/gloves, Sterile handling with a focus on contact transfer risk, tool/GSE preparation, and two-operator system for opening sterilized tools/components. Tool sterilization: All tools to be used during an aseptic operation need to be identified. Compatible tools are sterilized by DHMR or Autoclave. Double wrapped so that the exterior bag can be handled by a non-sterile operator, and the sterile. Tools that are not compatible with high heat do not come in contact with sensitive surfaces: either substitutes are found, or tools are isolated by wrapping in sterile foil. During an aseptic operation. Pre-task to make sure everyone understands the operations, who is handling what, and when the most critical surfaces will be exposed. Monitoring during the operation. Bioburden: active and passive airborne bioburden sampling, glove-tip dabs onto a plate after completion of operation (3 days for results). Particles: real time particle counter constantly running, with alarm for exceeding ISO 5 conditions.

aseptic processing↗

An Indirect Mixed-Sensitivity Approach to Microgravity Vibration Isolation: The Exploitation of Kinematic Coupling In Frequency-Weighting Design-Filter Selections

Many space science experiments need an active isolation system to provide them with the requisite microgravity environment. The isolation systems planned for use with the International Space Station have been appropriately modeled using relative position, relative velocity, and acceleration states. In theory, frequency design filters can be applied to these state-space models, in order to develop optimal H, or mixed-norm controllers with desired stability- and performance characteristics. In practice. however, the kinematic coupling among the various states can lead, through the associated frequency-weighting-filters, to conflicting demands on the Riccati design "machinery." The results can be numerically ill-conditioned regulator and estimator Riccati equations and/or reduced intuition in the design process. In addition, kinematic coupling can result in a redundancy in the demands imposed by the frequency weights. Failure properly to account for this type of coupling can lead to an unnecessary increase in controller dimensionality and, in turn, controller complexity. This paper suggests a rational approach to the assignment of frequency weighting design filters, in the presence of the kinematic coupling among states that exists in the microgravity vibration isolation problem.

Hampton, R. David↗

ISO Guest Observer Data Analysis and LWS Instrument Team Activities

We have designed and fabricated infrared filters for use at wavelengths greater than or equal to 15 microns. Unlike conventional dielectric filters used at the short wavelengths, ours are made from stacked metal grids, spaced at a very small fraction of the performance wavelengths. The individual lattice layers are gold, the spacers are polyimide, and they are assembled using integrated circuit processing techniques; they resemble some metallic photonic band-gap structures. We simulate the filter performance accurately, including the coupling of the propagating, near-field electromagnetic modes, using computer aided design codes. We find no anomalous absorption. The geometrical parameters of the grids are easily altered in practice, allowing for the production of tuned filters with predictable useful transmission characteristics. Although developed for astronomical instrumentation, the filters are broadly applicable in systems across infrared and terahertz bands.

Oliversen, Ronald J.↗

JPL Activated Carbon Treatment System (ACTS) for sewage

An Activated Carbon Treatment System (ACTS) was developed for sewage treatment and is being applied to a one-million gallon per day sewage treatment pilot plant in Orange County California. Activities reported include pyrolysis and activation of carbon-sewage sludge, and activated carbon treatment of sewage to meet ocean discharge standards. The ACTS Sewage treatment operations include carbon-sewage treatment, primary and secondary clarifiers, gravity (multi-media) filter, filter press dewatering, flash drying of carbon-sewage filter cake, and sludge pyrolysis and activation. Tests were conducted on a laboratory scale, 10,000 gallon per day demonstration plant and pilot test equipment. Preliminary economic studies are favorable to the ACTS process relative to activated sludge treatment for a 175,000,000 gallon per day sewage treatment plant.

Source record↗

Analytical Methods and Testbeds for Characterizing Adsorbents and Catalysts for Atmosphere Revitalization of Crewed Spacecraft

Spacecraft environmental control and life support systems (ECLSS) include a number of air revitalization (AR) technologies to provide breathable air and a comfortable living environment to the crew. Crew health and comfort is ensured by controlling human produced CO2 (1 kg person-1 day-1) and water vapor (~2 kg person-1 day-1), and by removing trace contaminants (TCs) from cabin air. These life support functions on-board the International Space Station (ISS) are carried out by the Carbon Dioxide Removal Assembly (CDRA), the Water Processor Assembly (WPA), and the trace contaminant control system (TCCS). During the development of the TCCS, new analytical and theoretical methods were developed in the 1970s for characterizing adsorption and desorption characteristics of activated carbons for the purpose of designing suitable AR technologies required for controlling airborne trace contaminants within spacecraft cabins during long exploration missions. The TCCS removes harmful volatile organic compounds and other trace contaminants from the circulating air. It consists of a granular activated carbon (GAC) bed for the removal of high molecular weight contaminants and ammonia followed by a heated catalytic bed for low molecular weight hydrocarbons. The high temperature catalytic oxidizer (HTCO) of the TCCS, which operates at 400°C and requires 120W average power, removes low molecular weight compounds such as carbon monoxide (CO), formaldehyde (CH2O), and methane (CH4), that pass through the GAC bed. The Air Revitalization Laboratory at the Kennedy Space Center (KSC) was established to develop new analytical methods for evaluating emerging ECLSS technologies for use in future AR architectures. General properties of adsorbents and catalysts are required for trace contaminant control system design calculations and vendor-supplied data are seldom available at relevant process conditions of interest to spacecraft cabin applications. To address this shortcoming, appropriate testbeds were developed to measure the desired properties of AR technologies being considered for use in ECLS architectures. Generally, the testbeds developed at KSC challenge the test media (activated carbon, impregnated activated carbon, catalysts, zeolites, solid amines, or pleated filters) with simulated spacecraft gas streams containing representative mixtures of trace contaminants (volatile organic compounds, ammonia, CO, CO2, or siloxanes) at the flow rates, temperatures, and relative humidity that will be encountered within manned spacecraft. Work performed at KSC funded by NASA’s Advanced Exploration (AES) Program has included: Identifying candidate sorbents to replace commercially obsolete impregnated carbons for NH3 control within the TCCS, characterizing their adsorptive capacities using simulated spacecraft gas streams, and ranking their appropriateness in various AR applications; evaluating novel low temperature catalysts for controlling CO and formaldehyde by traditional and photocatalytic methods for trace contaminant control; development of analytical methods to assess regenerable solid amine performance for CO2 control via pressure swing adsorption. The Air Revitalization lab was also funded to study trace contaminant control by other NASA programs. These include: screening of candidate sorbents for the design of new Charcoal HEPA Integrated Particle Scrubber (CHIPS) filters for removing siloxanes from cabin air; characterizing the performance of an impregnated activated carbon at low humidity for use in ORION ECLS; screening of sorbents for protecting the Sabatier 2.0 catalyst from DMSO2, siloxanes, NH3, and solid amine byproducts.

Monje, Oscar↗

Ultraviolet photometry of Nova Serpentis 1970

The appearance of the bright nova, Nova Serpentis 1970, provided the first opportunity to obtain spectrophotometric observations of a nova in the vacuum ultraviolet. OAO-2 carried out systematic measurements from shortly after outburst on through the first sixty days of nova activity. This data consist of filter photometry and spectral scans. General characteristics of the light and spectral variations in the ultraviolet exhibited by this set of data are described.

Code, A. D.↗

High efficiency ground data transmission

It is demonstrated that state-of-the-art communications technology can be implemented and reliably operated on a global basis to increase the transmission rates and efficiencies on circuits with bandwidths greater than the typical speech channel. Optimization is affected by optimum clock recovery procedures, multilevel pulse amplitude modulation, single sideband amplitude modulation, transversal filter equalizers, data scrambling, and active compensation for phase instability.

Dickinson, W. B.↗

Overview of the NASA tropospheric environmental quality remote sensing program

This paper will summarize the current NASA Tropospheric Environmental Quality Remote Sensing Program for studying the global and regional troposphere from space, airborne and ground-based platforms. As part of the program to develop remote sensors for utilization from space, NASA has developed a series of passive and active remote sensors which have undergone field test measurements from airborne and ground platforms. Recent measurements with active lidar and passive gas filter correlation and infrared heterodyne techniques will be summarized for measurements of atmospheric aerosols, CO, SO2, O3, and NH3. These measurements provide the data base required to assess the sensitivity of remote sensors for applications to urban and regional field measurement programs. Studies of Earth Observation Satellite Systems are currently being performed by the scientific community to assess the capability of satellite imagery to detect regions of elevated pollution in the troposphere. The status of NASA sponsored research efforts in interpreting satellite imagery for determining aerosol loadings over land and inland bodies of water will be presented, and comments on the potential of these measurements to supplement in situ and airborne remote sensors in detecting regional haze will be made.

Allario, F.↗

Ultraviolet observations of starburst systems with Astro and the Hubble Space Telescope

The capabilities of the Astro observatory and the Hubble Space Telescope (HST) for UV astronomical observations are discussed. The advantages of using UV for studying extragalactic problems are reviewed, including sensitivity to hot sources, the rich UV line spectra, sensitivity to interstellar dust, and dark UV sky background. The HST and Astro instrumentation and plans for launching the systems are described. Possibile uses of HST and Astro include the study of massive stars in the Galaxy and nearby galaxies, interstellar medium, the UV excess component in old stellar populations, deep UV surveys (filter imaging and slitless spectroscopy), active galactic nuclei, quasars, and starburst systems.

O'Connell, Robert W.↗