Search NASA⌕ Search

SEARCH · Search NASA

Results for “air ducts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Customer outcomes in Pay-As-You-Save programs

We review the energy and financial outcomes of households participating in several programs based on successive versions of the Pay As You Save¯ (PAYS¯) system. PAYS¯ programs offer non-debt financing for energy efficiency (and sometimes other technologies) in residential buildings through a tariff attached to the home’s utility meter, designed to be offset by project savings. We find that the five programs we study generally serve customers living in zip codes with levels of income and education below the national average and unemployment rates above the national average, demonstrating their potential to improve equity in energy efficiency adoption. Using weather-normalized analysis of energy consumption data, we show that most customers of Midwest Energy’s program reduce annual electricity and gas consumption, averaging 15% and 26% reductions respectively. Changes in energy consumption calculated using this method represent a combination of project effects and changes in occupant behavior. These results are similar to existing analyses of PAYS¯ programs in North Carolina, Arkansas, and Tennessee. About half of participating Midwest households generate sufficient energy cost savings to cover their monthly tariff. Various factors, including changes in occupant behavior, program error, causes independent of the customer or program, or some combination thereof may explain lower-than-expected cost reductions in some projects. Given the inherent variability in annual household electricity consumption, we feel these programs are enabling energy efficiency improvements and their attendant co-benefits, including occupant health and comfort and reduced carbon emissions, while reasonably balancing energy savings and tariff costs. Pairing PAYS¯ with additional financial assistance, as well as promoting cost-effective measures such as air and duct sealing, could further broaden program participation by enabling additional projects to meet PAYS¯ program eligibility rules.

Deason, Jeff↗

Intermodule ventilation studies for the Space Station

This paper examines the ability of the Space Station intermodule ventilation system to maintain centralized control of CO2 removal and O2 supply. The resulting concentration gradients that will arise are calculated by assuming steady state, ideal gas, isothermal conditions, and perfect mixing of air within and between the pressurized elements. In order to estimate the degree of mixing actually obtained for a given ventilation scheme, a program has been developed based on a potential flow solution technique. Preliminary results from this study indicate that substantial short circuiting and recirculation air flow patterns could arise if a simple duct and diffuser air exchange method at the docking port interface were employed.

Davis, Roy G.↗

ResStock Measure Documentation: Light Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Light Envelope" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

A Wind-Tunnel Investigation of a 4-Foot-Diameter Ducted Fan Mounted on the Tip of a Semispan Wing

Power, wing angle of attack, and the angle of the duct relative to the wing were varied to achieve a specified lift and thrust for a forward velocity range from 0 to 140 knots. In this manner a so-called transition program of steady-state conditions was defined over the velocity range. It was found-that large pitch-up moments resulted when the ducted fan was operated at an angle of attack to the air stream. A deflected vane installed in the high-energy air at the duct exit was helpful in reducing these pitch-up moments. Large downwash angles were induced by the ducted fan at a selected horizontal-tail location. The possibility of using guide vanes in the duct inlet to vary thrust for the purpose of roll control at low forward speeds was examined.The maximum incremental thrust available at zero forward velocity was found to be 11% of the total thrust required at that speed.

Yaggy, Paul F.↗

Apparatus for supplying conditioned air at a substantially constant temperature and humidity

The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.

Obler, H. D.↗

Multiple jet study data correlations

Correlations are presented which allow determination of penetration and mixing of multiple cold air jets injected normal to a ducted subsonic heated primary air stream. Correlations were obtained over jet-to-primary stream momentum flux ratios of 6 to 60 for locations from 1 to 30 jet diameters downstream of the injection plane. The range of geometric and operating variables makes the correlations relevant to gas turbine combustors. Correlations were obtained for the mixing efficiency between jets and primary stream using an energy exchange parameter. Also jet centerplane velocity and temperature trajectories were correlated and centerplane dimensionless temperature distributions defined. An assumption of a Gaussian vertical temperature distribution at all stations is shown to result in a reasonable temperature field model. Data are presented which allow comparison of predicted and measured values over the range of conditions specified above.

Walker, R. E.↗

Mixing of Supersonic Streams

The Strutjet approach to Rocket Based Combined Cycle (RBCC) propulsion depends upon fuel-rich flows from the rocket nozzles and turbine exhaust products mixing with the ingested air for successful operation in the ramjet and scramjet modes. A model of the Strutjet device has been built and is undergoing test to investigate the mixing of the streams as a function of distance from the Strutjet exit plane. Initial cold flow testing of the model is underway to determine both, the behavior of the ingested air in the duct and to validate the mixing diagnostics. During the tests, each of the two rocket nozzles ejected up to two pounds mass per second into the 13.6 square inch duct. The tests showed that the mass flow of the rockets was great enough to cause the entrained air to go sonic at the strut, which is the location of the rocket nozzles. More tests are necessary to determine whether the entrained air chokes due to the reduction in the area of the duct at the strut (a physical choke), or because of the addition of mass inside the duct at the nozzle exit (a Fabri choke). The initial tests of the mixing diagnostics are showing promise.

Hawk, Clark W.↗

Bioregenerative system components for microgravity

The goal of the class was to design, fabricate, and test prototype designs that were independent, yet applicable to a Closed Loop Life Support System. The three prototypes chosen were in the areas of agar plant growth, regnerative filtration, and microgravity food preparation. The plant growth group designed a prototype agar medium growth system that incorporates nutrient solution replenishment and post-harvest refurbishment. In addition, the unit emphasizes material containment and minimization of open interfaces. The second project was a filter used in microgravity that has the capability to clean itself. The filters are perforated plates which slide through a duct and are cleaned outside of the flow with a vacuum system. The air in the duct is prevented from flowing outside of the duct by a network of sliding seals. The food preparation group developed a device which dispenses and mixes ingredients and then cooks the mixture in microgravity. The dry ingredients are dispensed from a canister by a ratchet-operated piston. The wet ingredients are dispensed from plastic bags through tubing attached to a syringe. Once inside the mixing chamber, the ingredients are mixed using a collapsible whisk and then pushed into the cooking device.

Nevill, Gale E., Jr.↗

Development of Acoustic Mufflers for Cabin Noise Reduction in Orion Spacecraft

Controlling cabin acoustic noise levels in the Crew Module (CM) of the Orion spacecraft is critical to ensure adequate speech intelligibility, to avoid fatigue, and prevent any possibility of temporary and permanent hearing loss to the crew. The primary source of cabin noise for the on-orbit phase of the mission is from the Environmental Control and Life Support System (ECLSS) which recycles and conditions breathing air and maintains cabin pressurization through its duct network and components. Unfortunately, as a side effect, noise from the ECLSS fans propagates through theses ducts and emanate into the cabin habitable volume via the ECLSS inlet and outlets. To mitigate excessive duct-borne noise, two ECLSS mufflers have been designed to provide significant acoustic transmission loss (TL) so that the cabin noise requirements can be met. Each muffler is meant to be installed in the ducting of the ECLSS air inlet and outlet sides, respectively. Packaging constraints and tight volume requirements necessitated the mufflers to be of complex geometry and compatible with the bends of the ECLSS duct layout. To design and characterize the acoustic performance of the inlet and outlet mufflers, computational acoustic models were developed using the Finite Element Method (FEM) with 𝑤𝑎𝑣𝑒଺ vibroacoustic software. Characterization of the acoustic material and perforations in the mufflers were addressed with poroelastic theory. Once the mufflers were designed on paper and its TL predicted, prototypes of these mufflers were created using additive manufacturing. The muffler prototypes were subsequently tested for acoustic TL in the laboratory with various con-figurations of acoustic materials. Comparing the analytical predictions to the test performance yielded excellent correlation for acoustic TL and demonstrated significant broadband noise attenuation. The ECLSS mufflers are currently scheduled to be installed on the Artemis II Crew Module (CM) of the Orion spacecraft and will provide significant cabin comfort to crew during the mission.

Indranil Dandaroy↗

Development of an Experimental Rig for Investigation of Higher Order Modes in Ducts

Continued progress to reduce fan noise emission from high bypass ratio engine ducts in aircraft increasingly relies on accurate description of the sound propagation in the duct. A project has been undertaken at NASA Langley Research Center to investigate the propagation of higher order modes in ducts with flow. This is a two-pronged approach, including development of analytic models (the subject of a separate paper) and installation of a laboratory-quality test rig. The purposes of the rig are to validate the analytical models and to evaluate novel duct acoustic liner concepts, both passive and active. The dimensions of the experimental rig test section scale to between 25% and 50% of the aft bypass ducts of most modern engines. The duct is of rectangular cross section so as to provide flexibility to design and fabricate test duct liner samples. The test section can accommodate flow paths that are straight through or offset from inlet to discharge, the latter design allowing investigation of the effect of curvature on sound propagation and duct liner performance. The maximum air flow rate through the duct is Mach 0.3. Sound in the duct is generated by an array of 16 high-intensity acoustic drivers. The signals to the loudspeaker array are generated by a multi-input/multi-output feedforward control system that has been developed for this project. The sound is sampled by arrays of flush-mounted microphones and a modal decomposition is performed at the frequency of sound generation. The data acquisition system consists of two arrays of flush-mounted microphones, one upstream of the test section and one downstream. The data are used to determine parameters such as the overall insertion loss of the test section treatment as well as the effect of the treatment on a modal basis such as mode scattering. The methodology used for modal decomposition is described, as is a description of the mode generation control system. Data are presented which demonstrate the performance of the controller to generate the desired mode while suppressing all other cut on modes in the duct.

Gerhold, Carl H.↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Autoignition in a premixing-prevaporizing fuel duct using 3 different fuel injection systems at inlet air temperatures to 1250 K

Conditions were determined in a continuous-flow, premixing-prevaporizing duct at which autoignition occurred. Test conditions were representative of an advanced, regenerative-cycle, automotive gas turbine. The test conditions inlet air temperatures from 600 to 1250 K (a vitiated preheater was used), pressures from 170 to 600 kPa, air velocities of 10 to 30 m/sec, equivalence ratios from 0.3 to 1.0, mixing lengths from 10 to 60 cm, and residence times of 2 to 100 ms. The fuel was diesel number 2. The duct was insulated and had an inside diameter of 12 cm. Three different fuel injection systems were used: One was a single simplex pressure atomizer, and the other two were multiple-source injectors. The data obtained with the simplex and one of the multiple-source injectors agreed satisfactorily with the references and correlated with an Arrenhius expression. The data obtained with the other multiple source injector, which used multiple cones to improve the fuel-air distribution, did not correlate well with residence time.

Tacina, R. R.↗