Search NASA⌕ Search

SEARCH · Search NASA

Results for “application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SU-F-E-02: A Feasibility Study for Application of Metal Artifact Reduction Techniques in MR-Guided Brachytherapy Gynecological Cancer with Titanium Applicators

Purpose: Utilization of Titanium Tandem and Ring (T&R) applicators in MR-guided brachytherapy has become widespread for gynecological cancer treatment. However, Titanium causes magnetic field disturbance and susceptibility artifact, which complicate image interpretation. In this study, metal artifact reduction techniques were employed to improve the image quality and reduce the metal related artifacts. Methods: Several techniques were employed to reduce the metal artifact caused by titanium T&R applicator. These techniques include Metal Artifact Reduction Sequence (MARS), View Angle Tilting (VAT) to correct in-plane distortion, and Slice Encoding for Metal Artifact Correction (SEMAC) for through-plane artifact correction. Moreover, MARS can be combined with VAT to further reduce the in-plane artifact by reapplying the selection gradients during the readout (MARS+VAT). SEMAC uses a slice selective excitation but acquires additional z-encodings in order to resolve off-resonant signal and to reduce through-plane distortions. Results: Comparison between the clinical sequences revealed that increasing the bandwidth reduces the error in measured diameter of T&R. However, the error is larger than 4mm for the best case with highest bandwidth and spatial resolution. MARS+VAT with isotropic resolution of 1mm reduced the error to 1.9mm which is the least among the examined 2D sequences. The measured diameter of tandem from SEMAC+VAT has the closest value to the actual diameter of tandem (3.2mm) and the error was reduced to less than 1mm. In addition, SEMAC+VAT significantly reduces the blooming artifact in the ring compared to clinical sequences. Conclusion: A higher bandwidth and spatial resolution sequence reduces the artifact and diameter of applicator with a slight compromise in SNR. Metal artifact reduction sequences decrease the distortion associated with titanium applicator. SEMAC+VAT sequence in combination with VAT revealed promising results for titanium imaging and can be utilized for MR-guided brachytherapy in gynecological cancer. The author is employee with Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Machine and Application Aware Partitioning for Adaptive Mesh Refinement Applications. In: HPDC '17 Proceedings of the 26th International Symposium on High-Performance Parallel and Distributed Computing

Load balancing and partitioning are critical when it comes to parallel computations. Popular partitioning strategies based on space filling curves focus on equally dividing work. The partitions produced are independent of the architecture or the application. Given the ever-increasing relative cost of data movement and increasing heterogeneity of our architectures, it is no longer sufficient to only consider an equal partitioning of work. Minimizing communication costs are equally if not more important. Our hypothesis is that an unequal partitioning that minimizes communication costs significantly can scale and perform better than conventional equal-work partitioning schemes. This tradeoff is dependent on the architecture as well as the application. We validate our hypothesis in the context of a finite-element computation utilizing adaptive mesh-refinement. Our central contribution is a new partitioning scheme that minimizes the overall runtime of subsequent computations by performing architecture and application-aware non-uniform work assignment in order to decrease time to solution, primarily by minimizing data-movement. We evaluate our algorithm by comparing it against standard space-filling curve based partitioning algorithms and observing time-to-solution as well as energy-to-solution for solving Finite Element computations on adaptively refined meshes. We demonstrate excellent scalability of our new partition algorithm up to $262,144$ cores on ORNL's Titan and demonstrate that the proposed partitioning scheme reduces overall energy as well as time-to-solution for application codes by up to 22.0%.

Fernando, Milinda↗

Mass spectrometry in biomarker applications: from untargeted discovery to targeted verification, and implications for platform convergence and clinical application

It is really only in the last ten years that mass spectrometry (MS) has had a truly significant (but still small) impact on biomedical research. Much of this impact can be attributed to proteomics and its more basic applications. Early biomedical applications have included a number of efforts aimed at developing new biomarkers; however, the success of these endeavors to date have been quite modest - essentially confined to preclinical applications - and have often suffered from combinations of immature technology and hubris. Now that MS-based proteomics is reaching adolescence, it is appropriate to ask if and when biomarker-related applications will extend to the clinical realm, and what developments will be essential for this transition. Biomarker development can be described as a multistage process consisting of discovery, qualification, verification, research assay optimization, validation, and commercialization (1). From a MS perspective, it is possible to 'bin' measurements into 1 of 2 categories - those aimed at discovering potential protein biomarkers and those seeking to verify and validate biomarkers. Approaches in both categories generally involve digesting proteins (e.g., with trypsin) as a first step to yield peptides that can be effectively detected and identified with MS. Discovery-based approaches use broad 'unbiased' or 'undirected' measurements that attempt to cover as many proteins as possible in the hope of revealing promising biomarker candidates. A key challenge with this approach stems from the extremely large dynamic range (i.e., relative stoichiometry) of proteins of potential interest in biofluids such as plasma and the expectation that biomarker proteins of the greatest clinical value for many diseases may very well be present at low relative abundances (2). Protein concentrations in plasma extend from approximately 10{sup 10} pg/mL for albumin to approximately 10 pg/mL and below for interleukins and other cytokines.

59 BASIC BIOLOGICAL SCIENCES↗

Leveraging Application Data Constraints to Optimize Database-Backed Web Applications

Exploiting the relationships among data is a classical query optimization technique. As persistent data is increasingly being created and maintained programmatically, prior work that infers data relationships from data statistics misses an important opportunity. We present Coco, the first tool that identifies data relationships by analyzing database-backed applications. Once identified, Coco leverages the constraints to optimize the application's physical design and query execution. Instead of developing a fixed set of predefined rewriting rules, Coco employs an enumerate-test-verify technique to automatically exploit the discovered data constraints to improve query execution. Each resulting rewrite is provably equivalent to the original query. Using 14 real-world web applications, our experiments show that Coco can discover numerous data constraints from code analysis and improve real-world application performance significantly.

Computer Science↗

Shape Memory Alloys and their Applications in Power Generation and Refrigeration

The shape memory effect is closely related to the reversible martensitic phase transformation, which is diffusionless and involves shear deformation. The recoverable transformation between the two phases with different crystalline symmetry results in reversible changes in physical properties such as electrical conductivity, magnetization, and elasticity. Accompanying the transformation is a change of entropy. Fascinating applications are developed based on these changes. In this paper, the history, fundamentals and technical challenges of both thermoelastic and ferromagnetic shape memory alloys are briefly reviewed; applications related to energy conversion such as power generation and refrigeration as well as recent developments will be discussed.

energy generation↗

The Applicability of Unit Systems to High-Performance Computing Applications

Dimensional analysis is a key technique used to verify the soundness of scientific models. Most experts agree that engineering and scientific software would be made more reliable by integrating dimensional analysis in their type system. We explored how High Performance Computing (HPC) applications could integrate compile-time dimensional analysis. We started by investigating various implementation of unit systems for C++. Eventually, selecting the latest (and most advanced) one to apply to our test codes. We worked with code of increasing complexity, from a projectile trajectory calculation to the proxy-application Lulesh. This included our code, Springs-3D, which focuses on demonstrating language features while performing simple physic computations. Finally, our main contribution is a source-code analysis which extracts constraints on the dimension of all variables, functions, and constants in an application. This resulting system of equations is solved using the dimensions of a few of these objects. This analysis has the potential to greatly reduce the time spent performing dimensional analysis when refactoring application to use a representation of units.

97 MATHEMATICS AND COMPUTING↗

Fast All-Sky Radiation Model for Solar Applications (FARMS): A Brief Overview of Mechanisms, Performance, and Applications: Preprint

Solar radiation can be computed using radiative transfer models, such as the Rapid Radiation Transfer Model (RRTM) and its general circulation model applications, and used for various energy applications. Due to the complexity of computing radiation fields in aerosol and cloudy atmospheres, simulating solar radiation can be extremely time-consuming, but many approximations--e.g., the two-stream approach and the delta-M truncation scheme--can be utilized. To provide a new fast option for computing solar radiation, we developed the Fast All-sky Radiation Model for Solar applications (FARMS) by parameterizing the simulated diffuse horizontal irradiance and direct normal irradiance for cloudy conditions from the RRTM runs using a 16-stream discrete ordinates radiative transfer method. The solar irradiance at the surface was simulated by combining the cloud irradiance parameterizations with a fast clear-sky model, REST2. To understand the accuracy and efficiency of the newly developed fast model, we analyzed FARMS runs using cloud optical and microphysical properties retrieved using GOES data from 2009-2012. The global horizontal irradiance for cloudy conditions was simulated using FARMS and RRTM for global circulation modeling with a two-stream approximation and compared to measurements taken from the U.S. Department of Energy's Atmospheric Radiation Measurement Climate Research Facility Southern Great Plains site. Our results indicate that the accuracy of FARMS is comparable to or better than the two-stream approach; however, FARMS is approximately 400 times more efficient because it does not explicitly solve the radiative transfer equation for each individual cloud condition. Radiative transfer model runs are computationally expensive, but this model is promising for broad applications in solar resource assessment and forecasting. It is currently being used in the National Solar Radiation Database, which is publicly available from the National Renewable Energy Laboratory at http://nsrdb.nrel.gov.

14 SOLAR ENERGY↗

Assessing a mini-application as a performance proxy for a finite element method engineering application

The performance of a large-scale, production-quality science and engineering application (‘app’) is often dominated by a small subset of the code. Even within that subset, computational and data access patterns are often repeated, so that an even smaller portion can represent the performance-impacting features. If application developers, parallel computing experts, and computer architects can together identify this representative subset and then develop a small mini-application (‘miniapp’) that can capture these primary performance characteristics, then this miniapp can be used to both improve the performance of the app as well as provide a tool for co-design for the high-performance computing community. However, a critical question is whether a miniapp can effectively capture key performance behavior of an app. This study provides a comparison of an implicit finite element semiconductor device modeling app on unstructured meshes with an implicit finite element miniapp on unstructured meshes. The goal is to assess whether the miniapp is predictive of the performance of the app. Finally, single compute node performance will be compared, as well as scaling up to 16,000 cores. Results indicate that the miniapp can be reasonably predictive of the performance characteristics of the app for a single iteration of the solver on a single compute node.

97 MATHEMATICS AND COMPUTING↗

A Secure Web Application Providing Public Access to High-Performance Data Intensive Scientific Resources - ScalaBLAST Web Application

This work presents the ScalaBLAST Web Application (SWA), a web based application implemented using the PHP script language, MySQL DBMS, and Apache web server under a GNU/Linux platform. SWA is an application built as part of the Data Intensive Computer for Complex Biological Systems (DICCBS) project at the Pacific Northwest National Laboratory (PNNL). SWA delivers accelerated throughput of bioinformatics analysis via high-performance computing through a convenient, easy-to-use web interface. This approach greatly enhances emerging fields of study in biology such as ontology-based homology, and multiple whole genome comparisons which, in the absence of a tool like SWA, require a heroic effort to overcome the computational bottleneck associated with genome analysis. The current version of SWA includes a user account management system, a web based user interface, and a backend process that generates the files necessary for the Internet scientific community to submit a ScalaBLAST parallel processing job on a dedicated cluster.

43 PARTICLE ACCELERATORS↗

Triangular Elastomeric Stamps for Optical Applications: Near-Field Phase Shift Photolithography, 3D Proximity Field Patterning, Embossed Antireflective Coatings, and SERS Sensing

The use of a decal transfer lithography technique to fabricate elastomeric stamps with triangular cross-sections, specifically triangular prisms and cones, is described. These stamps are used in demonstrations for several prototypical optical applications, including the fabrication of multiheight 3D photoresist patterns with near zero-width features using near-field phase shift lithography, fabrication of periodic porous polymer structures by maskless proximity field nanopatterning, embossing thin-film antireflection coatings for improved device performance, and efficient fabrication of substrates for surface-enhanced Raman spectroscopic sensing. Furthermore, the applications illustrate the utility of the triangular poly(dimethylsiloxane) decals for a wide variety of optics-centric applications, particularly those that exploit the ability of the designed geometries and materials combinations to manipulate light–matter interactions in a predictable and controllable manner.

36 MATERIALS SCIENCE↗

Investigating power capping toward energy-efficient scientific applications: Investigating Power Capping toward Energy-Efficient Scientific Applications

The emergence of power efficiency as a primary constraint in processor and system design poses new challenges concerning power and energy awareness for numerical libraries and scientific applications. Power consumption also plays a major role in the design of data centers, which may house petascale or exascale-level computing systems. At these extreme scales, understanding and improving the energy efficiency of numerical libraries and their related applications becomes a crucial part of the successful implementation and operation of the computing system. In this paper, we study and investigate the practice of controlling a compute system's power usage, and we explore how different power caps affect the performance of numerical algorithms with different computational intensities. Further, we determine the impact, in terms of performance and energy usage, that these caps have on a system running scientific applications. This analysis will enable us to characterize the types of algorithms that benefit most from these power management schemes. Our experiments are performed using a set of representative kernels and several popular scientific benchmarks. Lastly, we quantify a number of power and performance measurements and draw observations and conclusions that can be viewed as a roadmap to achieving energy efficiency in the design and execution of scientific algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing Principle For Ni-rich Cathode Materials With High Energy Density For Practical Applications

Nickel(Ni)-rich lithium transition metal oxides (e.g. LiNi0.8Co0.15Al0.05O2 (NCA), LiNi1-x-yMnxCoyO2 (x+y<1) (NMC)) with layered structure are regarded as promising cathode candidates for constructing high energy density lithium ion batteries, so as to promote the market penetration of zero-emission electric vehicles. However, the poor structural and interfacial stability of Ni-rich NMC or NCA still hamper their large-scale applications. This review article mainly summarizes the recent progress achieved in the development of Ni-rich cathode materials, with an aim to provide important clues for future design Ni-rich cathodes and eventually enable their practical applications. Firstly, we introduce the improved method for the synthesis of Ni-rich cathode materials and discuss the relationships between the synthesis method, physicochemical properties, and the electrochemical performances of the cathode materials. Secondly, the insightful understandings on the capacity and voltage fading mechanism as well as the reasons of poor structure stability are comprehensively overviewed. Then, we summarize the main progress regarding to the novel approaches and attempts to prolong the cycling lifetime of Ni-rich materials and safety. Finally, we end up this review by proposing new perspectives and insights to stimulate more revolutionary strategies to boost the practical applications of Ni-rich cathodes.

high energy density, Ni-rich materials, modificati↗

Mucosal prior to systemic application of recombinant adenovirus boosting is more immunogenic than systemic application twice but confers similar protection against SIV-challenge in DNA vaccine-primed macaques

We investigated the immunogenicity and efficacy of a bimodal prime/boost vaccine regimen given by various routes in the Simian immunodeficiency virus (SIV) rhesus monkey model for AIDS. Twelve animals were immunized with SIV DNA-vectors followed by the application of a recombinant adenovirus (rAd5) expressing the same genes either intramuscularly (i.m.) or by oropharyngeal spray. The second rAd5-application was given i.m. All vaccinees plus six controls were challenged orally with SIVmac239 12 weeks post-final immunization. Both immunization strategies induced strong SIV Gag-specific IFN-{gamma} and T-cell proliferation responses and mediated a conservation of CD4{sup +} memory T-cells and a reduction of viral load during peak viremia following infection. Interestingly, the mucosal group was superior to the systemic group regarding breadth and strength of SIV-specific T-cell responses and exhibited lower vector specific immune responses. Therefore, our data warrant the inclusion of mucosal vector application in a vaccination regimen which makes it less invasive and easier to apply.

60 APPLIED LIFE SCIENCES↗

Recent Advances on Carbon Nanospheres. Synthetic Routes and Applications

Carbon-based materials are the most popular material types in both fundamental research and industrial applications, partly because of their well-controlled nano-morphologies. In the past two decades, we have witnessed a number of breakthroughs in carbon research: fullerenes, carbon nanotubes, and more recently graphene. Nowadays, carbon nanospheres are attracting more and more attention worldwide due to their excellent performance in various fields: drug delivery, heterogeneous catalysis, encapsulation of support and electrode materials. Actually, spherical carbon is an old material, whereas controlling carbon spheres in the nanometer range is a recent story. In the past 5 years, it has become possible to precisely control the particle size, surface area, pore size, chemical composition, and dispersity of carbon nanospheres. Toward this end, a number of synthetic strategies are emerging, such as hydrothermal carbonization of biomass-based resources, extended Stöber synthesis, and organic–organic self-assembly via different binding methods. In this feature article, we summarize recent routes for carbon nanospheres and briefly touch on their applications to shed light on the potential of this field. Throughout this article, a special emphasis is placed on the possible modulation of spherical structures at the nanoscale, and we wish to inspire many more designs and applications of carbon nanostructures in the near future.

36 MATERIALS SCIENCE↗

Near-infrared spectroscopy for burning plasma diagnostic applications

Ultraviolet and visible (UV-VIS, 200-750 nm) atomic spectroscopy of neutral and ionized fuel species (H, D, T, and Li) and impurities (e.g., He, Be, C, and W) is a key element of plasma control and diagnosis on International Thermonuclear Experimental Reactor and future magnetically confined burning plasma experiments (BPXs). Spectroscopic diagnostic implementation and performance issues that arise in the BPX harsh nuclear environment in the UV-VIS range, e.g., degradation of first mirror reflectivity under charge-exchange atom bombardment (erosion) and impurity deposition, permanent and dynamic loss of window, and optical fiber transmission under intense neutron and {gamma}-ray fluxes, are either absent or not as severe in the near-infrared (NIR, 750-2000 nm) range. An initial survey of NIR diagnostic applications has been undertaken on the National Spherical Torus Experiment. It is demonstrated that NIR spectroscopy can be used for machine protection and plasma control applications, as well as contribute to plasma performance evaluation and physics studies. Emission intensity estimates demonstrate that NIR measurements are possible in the BPX plasma operating parameter range. Complications in the NIR range due to the parasitic background emissions are expected to occur at very high plasma densities, low impurity densities, and at high plasma-facing component temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thick sputtered tantalum coatings for high-temperature energy conversion applications

Thick sputtered tantalum (Ta) coatings on polished Inconel were investigated as a potential replacement for bulk refractory metal substrates used for high-temperature emitters and absorbers in thermophotovoltaic energy conversion applications. In these applications, high-temperature stability and high reflectance of the surface in the infrared wavelength range are critical in order to sustain operational temperatures and reduce losses due to waste heat. The reflectance of the coatings (8 and 30 μm) was characterized with a conformal protective hafnia layer as-deposited and after one hour anneals at 700, 900, and 1100 °C. To further understand the high-temperature performance of the coatings, the microstructural evolution was investigated as a function of annealing temperature. X-ray diffraction was used to analyze the texture and residual stress in the coatings at four reflections (220, 310, 222, and 321), as-deposited and after anneal. No significant changes in roughness, reflectance, or stress were observed. No delamination or cracking occurred, even after annealing the coatings at 1100 °C. Overall, the results of this study suggest that the thick Ta coatings are a promising alternative to bulk substrates and pave the way for a relatively low-cost and easily integrated platform for nanostructured devices in high-temperature energy conversion applications.

36 MATERIALS SCIENCE↗