SU-E-T-223: Investigation of the Accuracy of Two-Dimensional Dose Distributions Measurement From High-Dose-Rate Brachytherapy Ir-192 Source Using Multiple-Diode-Array Detector (MapCheck2)

Purpose: To investigate the dosimetric accuracy of multiple-diode-array detector (Mapcheck2) for high-dose-rate brachytherapy Ir-192 source. The two-dimensional (2D) dose distributions measured with MapCheck2 were validated with EBT2 Gafchromic film measurement and AAPM task-group- 43 (TG-43) modeling. Methods: 2D-dose distributions from Ir-192 source were measured with MapCheck2 and EBT2-films. MapCheck2 response was corrected for effects: directional dependence, diode and phantom heterogeneity. Optical density growth of the film was controlled by synchronized scanning of the film exposed to Ir-192 and calibration films exposed to 6 MV linac beams. Similarly, MapCheck2 response was calibrated to dose using 6 MV beams. An empirical model was developed for the dose distributions measured with Mapcheck2 that considered directional, diode and phantom heterogeneity corrections. The dose deposited in solid-state-detectors was modeled using a cavity theory model for the diode. This model was then validated with measurements using EBT2-films and calculations with TG-43. Results: The response of MapCheck2 has been corrected for different effects including: (a) directional dependence of 0–20% over angular range 0o–90o, (b) phantom heterogeneity (3%) and (c) diode heterogeneity (9%). The corrected dose distributions measured with MapCheck2 agreed well with the measured dose distributions from EBT2-film and with calculations using TG-43 within 5% over a wide range of dose levels and rates. The advantages of MapCheck2 include less noisy, linear and stable response compared with film. The response of MapCheck2 exposed to 192Ir-source showed no energy dependence similar to its response to MV energy beam. Detection spatial-resolution of individual diodes was 0.8×0.8 mm2, however, 2DMapCheck2 resolution is limited by distance between diodes (7.07 mm). Conclusion: The dose distribution measured with MapCheck2 agreed well within 5% with that measured using EBT2-films; and calculations with TG- 43. Considering correction of artifacts, MapCheck2 provides a compact, practical and accurate dosimetric tool for measurement of 2D-dose distributions for brachytherapy Ir-192.

60 APPLIED LIFE SCIENCES↗

A 128 x 128 InGaAs detector array for 1.0 - 1.7 microns

A two-dimensional 128 x 128 detector array for the 1.0 - 1.7 micron spectral region has been demonstrated with indium gallium arsenide. The 30 micron square pixels had 60 micron spacing in both directions and were designed to be compatible with a 2D Reticon multiplexer. Dark currents below 100 pA, capacitance near 0.1 pF, and quantum efficiencies above 80 percent were measured. Probe maps of dark current and quantum efficiency are presented along with pixel dropout data and wafer yield which was as high as 99.89 percent (7 dropouts) in an area of 6528 pixels and 99.37 percent (103 dropouts) over an entire 128 x 128 pixel region.

Olsen, G.↗

Large Format Detector Arrays for Astrophysics

Improvements in detector design and advances in fabrication techniques has resulted in devices which can reach fundamental sensitivity limits in many cases. Many pressing astrophysical questions require large arrays of such sensitive detectors. I will describe the state of far infrared through millimeter detector development at NASA/GSFC, the design and production of large format arrays, and the initial deployment of these powerful new tools.

Moseley, Harvey↗

A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

Hartig, G. F.↗

Photon counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118

Hartig, G. F.↗

Modulation Transfer Function (MTF) measurement techniques for lenses and linear detector arrays

Application is the determination of the Modulation Transfer Function (MTF) for linear detector arrays. A system set up requires knowledge of the MTF of the imaging lens. Procedure for this measurement is described for standard optical lab equipment. Given this information, various possible approaches to MTF measurement for linear arrays is described. The knife edge method is then described in detail.

Schnabel, J. J., Jr.↗

Stilbene Scintillator Detector Array and Data-Acquisition System for Active Interrogation

A large area Stilbene crystal detector array has been assembled and calibrated for use in active interrogation measurements. The array consists of 10 high-efficiency 4”x2” stilbene cells. The cells were grown by Inrad Optics using LLNL developed technology. The array can be used to detect multiple signatures of SNM items, both actively and passively. Prompt and delayed gamma rays as well as prompt and delay neutrons can be detected and counted separately. The array is coupled to the Mesytec MDPP-16 VME-based digitizer module for data acquisition. This module performs on-board pulse-shape discrimination of signals from the Stilbene crystal detectors. This data-acquisition module allows separation of neutron and gamma-ray events with a low demand on data transfer rates. In addition, the high-resolution timing (<100 ps) is suitable for correlated gamma-ray and neutron multiplicity counting. This report describes the construction and calibration of the system. We also discuss applications of the system as well as how the system is currently being utilized by end users.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Laboratory characterization of direct readout Si:Sb and Si:Ga infrared detector arrays

Highlights of recent results obtained at Ames Research Center in performance evaluations of infrared detector arrays are presented. Antimony- and gallium-doped silicon direct readout 58x62 element hybrid devices from Ames' ongoing detector technology development program are described. The observed characteristics meet most of the performance goals specified by the Space Infrared Telescope Facility (SIRTF) instrument teams and compare favorably with the best performance reported for discrete non-integrating extrinsic silicon detectors. Initial results of radiation environment testing are reported, and non-ideal behavior demonstrated by these test devices is discussed.

Mckelvey, Mark E.↗

Thermopile Detector Arrays for Space Science Applications

Thermopile detectors are widely used in uncooled applications where small numbers of detectors are required, particularly in low-cost commercial applications or applications requiring accurate radiometry. Arrays of thermopile detectors, however, have not been developed to the extent of uncooled bolometer and pyroelectric/ferroelectric arrays. Efforts at JPL seek to remedy this deficiency by developing high performance thin-film thermopile detectors in both linear and two-dimensional formats. The linear thermopile arrays are produced by bulk micromachining and wire bonded to separate CMOS readout electronic chips. Such arrays are currently being fabricated for the Mars Climate Sounder instrument, scheduled for launch in 2005. Progress is also described towards realizing a two-dimensional thermopile array built over CMOS readout circuitry in the substrate.

Foote, M. C.↗

Initial Field Measurements with the Multisensor Airborne Radiation Survey (MARS) High Purity Germanium (HPGe) Detector Array

Abstract: The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gamma ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. The system is ruggedized and shock mounted for use in a variety of field applications. This paper reports on results from initial field measurements conducted in a truck and on two different boats.

characterization↗

Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detector

Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame –1 or 826 ns frame –1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. In conclusion, it was found that in burst mode the ratio of 2s to 1s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-background detector arrays for infrared astronomy

The status of a program which develops and characterizes integrated infrared (IR) detector array technology for space astronomical applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, coupled to silicon readout electronics. Low-background laboratory test results include measurements of responsivity, noise, dark current, temporal response, and the effects of gamma-radiation. In addition, successful astronomical imagery has been obtained on some arrays from this program. These two aspects of the development combine to demonstrate the strong potential for integrated array technology for IR space astronomy.

Mccreight, C. R.↗

Submillisecond X-ray photon correlation spectroscopy from a pixel array detector with fast dual gating and no readout dead-time

Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.

43 PARTICLE ACCELERATORS↗

The development and test of multi-anode microchannel array detector systems. 2: Soft X-ray detectors

The techniques and procedures for producing very-large-format pulse-counting array detector systems for use in forthcoming high-energy astrophysics facilities were defined, and the structures and performance characteristics of high-sensitivity photocathodes for use at soft X-ray wavelengths between 100 and 1 A were determined. The progress made to date in each of these areas are described and the tasks that will be undertaken when the program is continued are summarized.

Timothy, J. G.↗

Detector arrays for low-background space infrared astronomy

The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratory test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications.

Mccreight, C. R.↗

Detector arrays for low-background space infrared astronomy

The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratary test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications.

Mccreight, C. R.↗

Numerical analysis of temperature and stress fields in hybrid indium antimonide arrays detector with laser irradiation

Thermal-stress effects are the major cause of failure in infrared focal-plane arrays detector, during laser irradiation. Based on the established three-dimensional structural model of hybrid indium antimonide infrared focal-plane arrays, the temperature and stress fields of hybrid indium antimonide detectors irradiated by 1.064-μm Gauss pulsed laser are studied, considering the temperature-dependent material parameters. The results indicate that the temperature increase and thermal stress effects are different, in each layer. Especially in indium antimonide chip, which is the uppermost layer of the indium antimonide detector that directly absorbs laser energy, the temperature shows not a smooth decrease as laser intensity from centre to outside, but a concentric-ringed ripple decrease with discontinuous high temperature extremum areas; which induces its own unique stress distributions: during the laser irradiation region, the thermal stress in areas above indium bumps is much lower than that in areas above underfill, but the stress distribution outside the laser irradiation region is exactly the opposite. The temperature and stress distribution in other materials are also different from that in indium antimonide chip. The main reason is that each material has different thermal properties, especially indium bump and underfill, which are alternative distribution in middle layers, have quite different thermal parameters. All these make the temperature and stress distribution in each layer having own characteristics. In addition, the change trend of the maximum temperature and stress in each layer in accordance with the laser pulse number are also studied. The maximum stress as well as temperature always occurs in the indium antimonide chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Identification in the NIMROD-ISiS Detector Array

Interest in the influence of the neutron-to-proton (N/Z) ratio on multifragmenting nuclei has demanded an improvement in the capabilities of multi-detector arrays as well as the companion analysis methods. The particle identification method used in the NIMROD-ISiS 4{pi} array is described. Performance of the detectors and the analysis method are presented for the reaction of {sup 86}Kr+{sup 64}Ni at 35 MeV/u.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗