Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

System and method for parallel two-photon lithography using a metalens array

A metalens array is disclosed for controllably modifying a phase of a wavefront of an optical beam. The metalens array may have a substrate having at least first and second metalens unit cells, and forming a single integrated structure with no stitching being required of the first and second metalens unit cells. The first metalens unit cell has a first plurality of nanoscale features and is configured to modify a phase of a first portion of a wavefront of an optical signal incident thereon in accordance with a first predetermined phase pattern to create at least one first focal voxel within an image plane. The second metalens unit cell has a second plurality of nanoscale features configured to modify the phase of a second portion of the wavefront of the optical signal incident thereon, in accordance with a second predetermined phase pattern, to simultaneously create at least one second focal voxel within the image plane. Each metalens unit cell also has an overall diameter of no more than about 200 microns.

Xia, Xiaoxing↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Automated Redox Titrations via Interdigitated Electrode Arrays: Application to the Mediated Electron Transfer Interrogation of Charge and Rate on Electrodeposited Polymers

Mediated electron transfer (MET) plays a crucial role in energy storage and conversion technologies such as redox targeting flow batteries (RTFBs), yet its experimental investigation often requires labor-intensive and low-throughput setups. To address this, we developed a microfabricated interdigitated electrode array (IDA) platform that enables automated, high-throughput electrochemical redox titration measurement to be performed to study the MET process. Our redox titration method enables simultaneous measurement of the charge capacity and rate of MET processes on a material or surface. Automated redox titration (ART) facilitates systematic investigation of the MET process across a broad parameter space, exemplified through the study of polypyrrole (PPy) and a pyrene-4,5,9,10-tetrone azo group-based polymer (PTAP), both redox-active polymers relevant to various energy storage applications. Using PPy as a model material, 500 redox titration measurements were conducted within 50 h, varying the electrode gap widths, polymer charging potentials, voltammetric scan rates, and electrolyte concentrations. Finite-element simulations confirmed the electrochemical responses and elucidated the kinetics of the MET reactions. Our automated methodology was further tested with PTAP, revealing a surprising charging potential dependence on the rate of MET. The automation, flexibility, and scalability of our redox titration platform pave the way not only for advanced studies of MET processes relevant to RTFBs, but also with implications in the understanding of next-generation energy storage materials, molecular electrocatalysis, and biosensing.

electrochemical analysis↗

Effect of activation temperature on quantum efficiency and lifetime of NEA truncated nanocone array GaAs photocathode

This study investigates the quantum efficiency (QE) and operational lifetime of a negative electron affinity GaAs truncated nanocone array (TNCA) photocathode benchmarked against a conventional flat GaAs photocathode under varying activation temperatures. The TNCA structure demonstrated a QE of up to 13.6% at 590 nm with room temperature (RT) activation—approximately 1.5 times higher than its flat counterpart. This enhancement is due to Mie resonance effects within the nanostructure, as confirmed by finite-difference time-domain simulations. Moreover, the TNCA photocathode exhibits significantly extended charge lifetime, with enhancement factors of ∼6.1 and ∼19.8 under RT and 50 °C activations, respectively. These gains are primarily attributed to increased effective surface area and optimized dipole layer formation at elevated temperatures. In addition, shorter excitation wavelengths further contribute to lifetime improvements. These findings underscore the TNCA GaAs photocathode’s potential as a high QE, long lifetime electron source for many large-scale electron accelerators.

Cs-NF3 activation↗

Signal Whisperers: Enhancing Wireless Reception Using DRL-Guided Reflector Arrays

This paper presents a multi-agent reinforcement learning (MARL) approach for controlling adjustable metallic reflector arrays to enhance wireless signal reception in non-line-of-sight (NLOS) scenarios. Unlike conventional reconfigurable intelligent surfaces (RIS) that require complex channel estimation, our system employs a centralized training with decentralized execution (CTDE) paradigm where individual agents corresponding to reflector segments autonomously optimize reflector element orientation in three-dimensional space using spatial intelligence based on user location information. Through extensive ray-tracing simulations with dynamic user mobility, the proposed multi-agent beam-focusing framework demonstrates substantial performance improvements over single-agent reinforcement learning baselines, while maintaining rapid adaptation to user movement within one simulation step. Comprehensive evaluation across varying user densities and reflector configurations validates system scalability and robustness. The results demonstrate the potential of learning-based approaches for adaptive wireless propagation control.

deep reinforcement learning↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

99 GENERAL AND MISCELLANEOUS↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

36 MATERIALS SCIENCE↗

Spatiotemporal Thermal Coupling in VO 2 Device Arrays

Correlated oxides such as VO 2 exhibit an electrically driven insulator–metal transition (IMT) that underlies their promise for neuromorphic and memory devices. Yet the IMT is not a uniform bulk process but a spatiotemporal phenomenon in which local heating nucleates filaments, contracts or dissolves them with the electric field, and couples to the environment. In this work, we directly image the VO 2 IMT dynamics by mid-wave infrared, thermography synchronized with electrical transport, resolving device temperature with micrometer spatial and microsecond temporal resolution. At the single-device level, we capture the full cycle of filament nucleation, contraction, and relaxation during current/voltage-driven resistive switching. At the array level, we show that heat propagates across etched gaps with an effective length scale of ∼131 µm, enabling cooperative behaviors among electrically isolated devices. Short-range distanced devices exhibit mutual filament attraction and sequential dissolution, while long-range distanced devices differentiate into distinct roles: drivers that initiate switching, cooperative responders that undergo assisted self-oscillations, and passive reporters that record the thermal field. Furthermore, these results reframe thermal crosstalk, long regarded as parasitic, as an intrinsic coupling channel and design principle for organizing collective switching behaviors, with direct implications for emergent circuit functionality in neuromorphic and unconventional computing architectures.

coupling↗

Magnetic Solitons and Thickness‐Dependent Magnetization Reversal in Interconnected Helical Nanowire Arrays

By expanding magnetic nanostructures into the third dimension, it is possible to introduce new interactions and realize new forms of magnetic textures and emergent phenomena. Consequently, this unlocks new opportunities for applications in data storage, unconventional computing and sensing by utilizing 3D devices with enhanced functionalities. Connected magnetic nanowires offer a unique platform for applications such as neuromorphic computing due to their tunability and the presence of multiple transport pathways. However to realize this promise, it is necessary to further our understanding of how to locally control the magnetization in 3D, nanowire-based geometries. In this work we show the formation of magnetic domain walls, vortices, anti-vortices, and linked vortex-anti-vortex pairs in interconnected helical nanowire arrays. We show how wire diameter and 3D geometric design can control the states that form and reveal the magnetization reversal mechanism. Hence, we demonstrate this to be a highly tunable system, where the magnetization can be readily reconfigured by an external magnetic field.

3D Nanomagnetism↗

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.↗

Fundamental physics opportunities with future ground-based mm/sub-mm VLBI arrays

The Event Horizon Telescope (EHT) Collaboration recently published the first images of the supermassive black holes in the cores of the Messier 87 and Milky Way galaxies. These observations have provided a new means to study supermassive black holes and probe physical processes occurring in the strong-field regime. We review the prospects of future observations and theoretical studies of supermassive black hole systems. Current ground-based very-long-baseline interferometry (VLBI) arrays like the EHT and proposed future extensions like the next-generation Event Horizon Telescope will greatly enhance the capabilities of black-hole imaging interferometry. These enhancements will open up several previously inaccessible avenues of investigation, thereby providing important new insights into the properties of supermassive black holes and their environments. This review describes the current state of knowledge for five key science cases, summarising the unique challenges and opportunities for fundamental physics investigations that future mm/sub-mm VLBI developments will enable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new approach to include electron interaction effects in super transition array opacity theory

A method is presented for the improved calculation of super-shell partition functions which include the repulsive electron–electron interaction energy terms in the Boltzmann factor. Heretofore these interaction terms were approximately treated via the use of Feynman–Jensen inequalities. Further, such investigations are of particular interest for the super-transition-array approach of hot-plasma radiative opacity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Facile synthesis of Co(OH)2 nanoneedle arrays grown on stainless steel for industrial electrochemical oxygen evolution reaction

The electrochemical oxygen evolution reaction (OER) is a critical half-reaction in a variety of energy conversion and storage applications, however, OER suffers from sluggish kinetics due to the four proton-electron transfer processes. To remedy this, interfacial engineering proves an effective strategy to design high active OER catalysts. Herein, we report a facile synthesis of Co(OH)2 nanoneedle (Co-NN) arrays grown on stainless steel (SS) via a one-step hydrothermal reaction, and the resultant impressive OER performance. Particularly, the Co-NN/SS needs 267, 307, and 576 mV overpotentials to reach 10, 100, and 1000 mA cm−2 in 1 M KOH & room temperature, and the overpotentials drop to 199, 257, and 283 mV to achieve the same current densities in 30 wt% KOH & 80 °C. Additionally, an alkaline water electrolysis (AWE) cell coupled with Co-NN/SS anode and PtRu/NiMo cathode only requires 1.65 and 1.73 V iR-free cell voltage to reach 1.0 and 2.0 A cm−2, respectively. The sterling OER performance could be attributed to four possible reasons, the Fe in SS surface tailoring the electronic properties of Co(OH)2, the mixed metal oxides on SS surface accelerating surface reconstruction of Co(OH)2 nanoneedles into CoOOH active species, a Ni-rich surface layer formation cooperatively boosting the OER activity, and a local electric field effect concentrating reactants on the tip surface and accelerating the mass transfer. This work provides a facile approach for synthesizing highly efficient OER catalysts for industrial applications by interfacial engineering.

Lyu, Xiang [ORNL] (ORCID:0000000208673248)↗

Gap junctions fine-tune ganglion cell signals to equalize response kinetics within a given electrically coupled array

Retinal ganglion cells (RGCs) summate inputs and forward a spike train code to the brain in the form of either maintained spiking (sustained) or a quickly decaying brief spike burst (transient). We report diverse response transience values across the RGC population and, contrary to the conventional transient/sustained scheme, responses with intermediary characteristics are the most abundant. Pharmacological tests showed that besides GABAergic inhibition, gap junction (GJ)–mediated excitation also plays a pivotal role in shaping response transience and thus visual coding. More precisely GJs connecting RGCs to nearby amacrine and RGCs play a defining role in the process. These GJs equalize kinetic features, including the response transience of transient OFF alpha (tOFFα) RGCs across a coupled array. We propose that GJs in other coupled neuron ensembles in the brain are also critical in the harmonization of response kinetics to enhance the population code and suit a corresponding task.

59 BASIC BIOLOGICAL SCIENCES↗