Search NASA⌕ Search

SEARCH · Search NASA

Results for “atom interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Compact laser source with frequency modulators generating multiple lines

A compact laser source and a single sideband modulator used therein is disclosed. The compact laser source includes a seed laser and one or more channels, with each channel generating one or more output laser beams having corresponding different wavelengths. The compact laser source can be formed in whole or in part on a single optical motherboard to thereby minimize space and power requirements. By employing the disclosed single sideband modulator, harmonics in the generated output laser beams can be minimized. The compact laser source finds application in an atom interferometer (AI) system, which may be used to measure gravity, acceleration, or rotation of the AI system.

Lentine, Anthony L.↗

Dissipation Enables Strongly Detuning-Dependent Interference in Pulsed Dynamical Decoupling

One of the defining features of pulsed dynamical decoupling is its suppression of a driven qubit's sensitivity to static detuning errors between the drive field and qubit resonance. In this paper, we show that dissipation, in the form of excited-state decay, can change this behavior entirely, producing an interference signal with a strong detuning dependence. This signal arises from decay during driven evolution and relies on coherence retained by the qubit after such a decay event. We develop analytical and numerical models that capture the underlying mechanism and observe this same dissipation-induced detuning dependence experimentally in both a free-space strontium atom interferometer and a superconducting transmon qubit system. We also use this dissipation-induced detuning dependence as the basis for a new spectroscopic technique called Dissipative Carr-Purcell Spectroscopy (DCPS) and compare it with a traditional Ramsey sequence. Our results establish a regime of pulsed dynamical decoupling in which dissipation reshapes, rather than merely degrades, coherent control, and we expect these dynamics to be relevant to a wide range of quantum systems.

DeRose, Kenneth [Northwestern U.; Fermilab] (ORCID↗

Development of a magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals; static magnetic fields must also be tightly controlled to manage measurement resolution. Several tools are being applied to the problem, including mu-metal shielding, field biasing, and a suite of magnetometers. This report details the development of a magnetic field monitoring system to be built from commercially available parts and installed at seventeen locations, one for each of the modular sections making up the length of the MAGIS-100 apparatus.

Arce, Edwin [Unlisted, US, CA]↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Fast phase stabilization of a low frequency beat note for atom interferometry

Atom interferometry experiments rely on the ability to obtain a stable signal that corresponds to an atomic phase. For interferometers that use laser beams to manipulate the atoms, noise in the lasers can lead to errors in the atomic measurement. In particular, it is often necessary to actively stabilize the optical phase between two frequency components of the beams. Typically this is achieved using a time-domain measurement of a beat note between the two frequencies. This becomes challenging when the frequency difference is small and the phase measurement must be made quickly. The method presented here instead uses a spatial interference detection to rapidly measure the optical phase for arbitrary frequency differences. A feedback system operating at a bandwidth of about 10 MHz could then correct the phase in about 3 μs. This time is short enough that the phase correction could be applied at the start of a laser pulse without appreciably degrading the fidelity of the atom interferometer operation. The phase stabilization system was demonstrated in a simple atom interferometer measurement of the {sup 87}Rb recoil frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Enhanced Cavity QED Interferometer with Partially Delocalized Atoms in Lattices

Herein, we propose a quantum enhanced interferometric protocol for gravimetry and force sensing using cold atoms in an optical lattice supported by a standing-wave cavity. By loading the atoms in partially delocalized Wannier-Stark states, it is possible to cancel the undesirable inhomogeneities arising from the mismatch between the lattice and cavity fields and to generate spin squeezed states via a uniform one-axis twisting model. The quantum enhanced sensitivity of the states is combined with the subsequent application of a compound pulse sequence that allows us to separate atoms by several lattice sites. This, together with the capability to load small atomic clouds in the lattice at micrometric distances from a surface, make our setup ideal for sensing short-range forces. We show that for arrays of 10 4 atoms, our protocol can reduce the required averaging time by a factor of 10 compared to unentangled lattice-based interferometers after accounting for primary sources of decoherence.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Abrasion of Photovoltaic Glass: A Comparison of the Effects of Natural and Artificial Aging

Natural soiling and the subsequent requisite cleaning of photovoltaic (PV) modules result in abrasion damage to the cover glass. The durability of the front glass has important economic consequences, including determining the use of antireflective and/or antisoiling coatings as well as the method and frequency of operating maintenance (cleaning). The abrasion of coatings and glass has been explored in a field study, including the soiling-prone locations of Dubai (United Arab Emirates), Kuwait City (Kuwait), Mesa (Arizona), Mumbai (India), and Sacramento (California). Dry-brush-cleaned specimens will be compared to those subjected to artificial-brush testing. The characteristics of material integrity, surface energy, optical transmittance, surface roughness, and scratch size were examined using an optical microscope, contact goniometer (for water), spectrophotometer, interferometer, and atomic force microscope (AFM), respectively. The findings of this study will be used to provide feedback regarding the cleaning equipment, cleaning methods, and coatings used in the PV industry. The study here will also be used to aid in developing an abrasion standard for the PV industry.

14 SOLAR ENERGY↗

Robust Optimized Pulse Schemes for Atomic Fountain Interferometry

The robustness of an atomic fountain interferometer with respect to variations in the initial velocity of the atoms and deviations from the optimal pulse amplitude is examined. We numerically simulate the dynamics of an interferometer in momentum space with a maximum separation of and map out the expected signal contrast depending on the variance of the initial velocity distribution and the value of the laser field amplitude. We show that an excitation scheme based on rapid adiabatic passage significantly enhances the expected signal contrast, compared to the commonly used scheme consisting of a series of and pulses. We demonstrate further substantial increase of the robustness by using optimal control theory to identify splitting and swapping pulses that perform well on an ensemble average of pulse amplitudes and velocities. Our results demonstrate the ability of optimal control to significantly enhance future implementations of atomic fountain interferometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laboratory Apparatus Generates Dual-Species Cold Atomic Beam

A laser cooling apparatus that generates a cold beam of rubidium and cesium atoms at low pressure has been constructed as one of several intermediate products of a continuing program of research on laser cooling and atomic physics. Laser-cooled atomic beams, which can have temperatures as low as a microkelvin, have been used in diverse applications that include measurements of fundamental constants, atomic clocks that realize the international standard unit of time, atom-wave interferometers, and experiments on Bose-Einstein condensation. The present apparatus is a prototype of one being evaluated for use in a proposed microgravitational experiment called the Quantum Interferometric Test of Equivalence (QuITE). In this experiment, interferometric measurements of cesium and rubidium atoms in free fall would be part of a test of Einstein s equivalence principle. The present apparatus and its anticipated successors may also be useful in other experiments, in both microgravity and normal Earth gravity, in which there are requirements for dual-species atomic beams, low temperatures, and low pressures. The apparatus includes a pyramidal magneto-optical trap in which the illumination is provided by multiple lasers tuned to frequencies characteristic of the two atomic species. The inlet to the apparatus is located in a vacuum chamber that contains rubidium and cesium atoms at a low pressure; the beam leaving through the outlet of the apparatus is used to transfer the atoms to a higher-vacuum (lower-pressure) chamber in which measurements are performed. The pyramidal magneto-optical trap is designed so that the laser cooling forces in one direction are unbalanced, resulting in a continuous cold beam of atoms that leak out of the trap (see figure). The radiant intensity (number of atoms per unit time per unit solid angle) of the apparatus is the greatest of any other source of the same type reported to date. In addition, this is the first such apparatus capable of producing a slow, collimated beam that contains two atomic species at the same time.

Thompson, Robert↗

Atom Interferometry for Detection of Gravitational Waves: NASA Institute for Advanced Concepts (NIAC) - Phase 1 Final Report

This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 "Atom Interferometry for Detection of Gravitational Waves" project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket

Saif, Babak N.↗

Soiling Related Abrasion and the Development of a PV Abrasion Standard

The natural soiling and consequent cleaning of photovoltaic (PV) modules result in abrasion damage to the cover glass. The durability of the front glass has important economic consequences, including the use of antireflective and/or antisoiling coatings as well as the method and frequency of cleaning-maintenance. The abrasion of glass and coated glass has been explored in a field study, including the soiling-prone locations of: Dubai (United Arab Emirates), Kuwait city (Kuwait), Mesa (Arizona), Mumbai (India), and Sacramento (California). Dry brush cleaned specimens will be compared to those subject to artificial brush testing or falling sand abrasion. The characteristics of material integrity, optical transmittance, surface energy, surface roughness, and scratch size were examined using an optical microscope, spectrophotometer, contact goniometer (for water), interferometer, and atomic force microscope, respectively. The findings of this study will be used to provide feedback regarding the cleaning equipment, cleaning methods, and coatings used in the PV industry. The study here will also be used to aid the development of an abrasion standard for the PV industry.

14 SOLAR ENERGY↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Truncated Nonlinear Interferometry for Quantum-Enhanced Atomic Force Microscopy

Nonlinear interferometers that replace beam splitters in Mach-Zehnder interferometers with nonlinear amplifiers for quantum-enhanced phase measurements have drawn increasing interest in recent years, but practical quantum sensors based on nonlinear interferometry remain an outstanding challenge. Here, we demonstrate the first practical application of nonlinear interferometry by measuring the displacement of an atomic force microscope microcantilever with quantum noise reduction of up to 3 dB below the standard quantum limit, corresponding to a quantum-enhanced measurement of beam displacement of 1.7 fm/√Hz. Further, we minimize photon backaction noise while taking advantage of quantum noise reduction by transducing the cantilever displacement signal with a weak squeezed state while using dual homodyne detection with a higher power local oscillator. This approach may enable quantum-enhanced broadband, high-speed scanning probe microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Twilight and nighttime ionospheric temperatures from oxygen wavelengths 6300 and 5577 spectral line profiles

Fabry-Perot interferometer measurements of atomic oxygen 6300 A and 5577 A line profiles from twilight and nightglow are used to determine the neutral temperatures in F2 and E regions of the earth's ionosphere. The exospheric temperatures T sub n (infinity) determined from the 6300 A profiles are usually somewhat higher than those calculated from Jacchia's model, with differences as large as approximately 300 K noted when T sub n (infinity) = 1500 to 1600 K. The post-sunset and pre-dawn rate of change of T sub n (infinity) is often substantially larger than the Jacchia prediction. The 5577 A (E-region) measured temperatures range from 200 to 220 K on quiet nights to 500 to 600 K during geomagnetic storms.

Feibelman, W. A.↗