Search NASA⌕ Search

SEARCH · Search NASA

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A miniature remote deadweight calibrator

A miniature, computer-controlled, deadweight calibrator was developed to remotely calibrate a force transducer mounted in a cryogenic chamber. This simple mechanism allows automatic loading and unloading of deadweights placed onto a skin friction balance during calibrations. Equipment for the calibrator includes a specially designed set of five interlocking 200-milligram weights, a motorized lifting platform, and a controller box taking commands from a microcomputer on an IEEE interface. The computer is also used to record and reduce the calibration data and control other calibration parameters. The full-scale load for this device is 1,000 milligrams; however, the concept can be extended to accommodate other calibration ranges.

Supplee, Frank H., Jr.↗

National transonic facility Mach number system

The Mach number system for the Langley Research Center's National Transonic Facility was designed to measure pressures to determine Mach number to within + or - 0.002. Nine calibration laboratory type fused quartz gages, four different range gages for the total pressure measurement, and five different range gages for the static pressure measurement were used to satisfy the accuracy requirement over the 103,000-890,000 Pa total pressure range of the tunnel. The system which has been in operation for over 1 year is controlled by a programmable data process controller to select, through the operation of solenoid valves, the proper range fused quartz gage to maximize the measurement accuracy. The pressure gage's analog outputs are digitized by the process controller and transmitted to the main computer for Mach number computation. An automatic two-point on-line calibration of the nine quartz gages is provided using a high accuracy mercury manometer.

Kern, F. A.↗

Photometric Calibration of Consumer Video Cameras

Equipment and techniques have been developed to implement a method of photometric calibration of consumer video cameras for imaging of objects that are sufficiently narrow or sufficiently distant to be optically equivalent to point or line sources. Heretofore, it has been difficult to calibrate consumer video cameras, especially in cases of image saturation, because they exhibit nonlinear responses with dynamic ranges much smaller than those of scientific-grade video cameras. The present method not only takes this difficulty in stride but also makes it possible to extend effective dynamic ranges to several powers of ten beyond saturation levels. The method will likely be primarily useful in astronomical photometry. There are also potential commercial applications in medical and industrial imaging of point or line sources in the presence of saturation.This development was prompted by the need to measure brightnesses of debris in amateur video images of the breakup of the Space Shuttle Columbia. The purpose of these measurements is to use the brightness values to estimate relative masses of debris objects. In most of the images, the brightness of the main body of Columbia was found to exceed the dynamic ranges of the cameras. A similar problem arose a few years ago in the analysis of video images of Leonid meteors. The present method is a refined version of the calibration method developed to solve the Leonid calibration problem. In this method, one performs an endto- end calibration of the entire imaging system, including not only the imaging optics and imaging photodetector array but also analog tape recording and playback equipment (if used) and any frame grabber or other analog-to-digital converter (if used). To automatically incorporate the effects of nonlinearity and any other distortions into the calibration, the calibration images are processed in precisely the same manner as are the images of meteors, space-shuttle debris, or other objects that one seeks to analyze. The light source used to generate the calibration images is an artificial variable star comprising a Newtonian collimator illuminated by a light source modulated by a rotating variable neutral- density filter. This source acts as a point source, the brightness of which varies at a known rate. A video camera to be calibrated is aimed at this source. Fixed neutral-density filters are inserted in or removed from the light path as needed to make the video image of the source appear to fluctuate between dark and saturated bright. The resulting video-image data are analyzed by use of custom software that determines the integrated signal in each video frame and determines the system response curve (measured output signal versus input brightness). These determinations constitute the calibration, which is thereafter used in automatic, frame-by-frame processing of the data from the video images to be analyzed.

Suggs, Robert↗

A turbojet simulator for Mach numbers up to 2.0

A turbojet simulator was designed and fabricated for use in wind tunnel models. The simulator contains a six-stage, axial-flow compressor powered by a three-stage, axial-flow turbine. High pressure heated air was used to drive the turbine. At design conditions, compressor axial flow, turbine exit flow, and a third supplementary flow all entered the exhaust nozzle at equal values of pressure and termperature. Overall aerodynamic design, compressor operating conditions, automatic controls, turbine aerodynamic design, instrumentation, and calibration procedure is presented. Performance of the device when used to simulate a J-85 turbojet engine at transonic speeds is reported. The installed nozzle performance obtained with the simulator is also discussed and compared with flight data.

Steffen, F. W.↗

Digital tape drive monitor

Network checks skew and character spacing of digital tape drive systems automatically. Tape drive is set up and calibrated to check any written tape when tape is read back. It will indicate track errors or character spacing errors should they exceed specifications.

Mckenna, R. T.↗

Air-consumption parameters for automatic mixture control of aircraft engines

Data obtained from Navy calibration tests of an 18-cylinder, two-row, radial engine of 3350-cubic-inch displacement and a 14-cylinder, two-row, radial engine of 2600-cubic-inch displacement (carburetor types) were analyzed to show the correlation between the air consumption of these engines and the parameters that evaluate the air consumption from intake-manifold temperature and pressure, exhaust back pressure, and engine speed.

Shames, Sidney J↗

Self-calibrating models for dynamic monitoring and diagnosis

A method for automatically building qualitative and semi-quantitative models of dynamic systems, and using them for monitoring and fault diagnosis, is developed and demonstrated. The qualitative approach and semi-quantitative method are applied to monitoring observation streams, and to design of non-linear control systems.

Kuipers, Benjamin↗

Automated Camera Array Fine Calibration

Using aerial imagery, the JPL FineCalibration (JPL FineCal) software automatically tunes a set of existing CAHVOR camera models for an array of cameras. The software finds matching features in the overlap region between images from adjacent cameras, and uses these features to refine the camera models. It is not necessary to take special imagery of a known target and no surveying is required. JPL FineCal was developed for use with an aerial, persistent surveillance platform.

Clouse, Daniel↗

Venus radar mapping from the Venera 15 and 16 spacecrafts: Results and restrictions

A description of the results of the Venus northern hemisphere radar survey in 1983-1984 from the Venera 15 and 16 spacecrafts is presented. In addition, we discuss some peculiarities in the function of the radar equipment that defined the technology of SAR data processing. Among these peculiarities are insufficient calibration of SAR and radar altimeter and erroneous automatic gain control data transmission from the spacecrafts. As a result, the procedure of image synthesis and mosaicking contained multistage image brightness corrections. This led to the fact that the average image brightness in a spot 100 km in diameter was constant everywhere in the mosaics. Twenty-seven radar mosaics in the Lambert-Hauss conic projection with 1-2 km spatial resolution covering 25 percent of the surface of Venus have been produced. A Venus surface roughness map was constructed by joint processing of SAR and altimeter data. The mutual calibration of the SAR and altimeter was made in the special radar session when the SAR and altimeter were declined from the local vertical at the same angle. The possibility of estimating relative variations in surface reflection properties over a tens-of-kilometers interval from Venera images is still being considered. Joint analysis of the coordinates of small features of the Venera and Magellan images is one more approach being used to refine the period of rotation for Venus.

Akim, E. L.↗

Automatic Phasing for Active Antenna Elements

Automatic phasing system periodically interrupts antenna operation for calibration intervals and measures phase and amplitude response at each active antenna element. Using these measurements, system adjusts phase shift and possibly gain of active elements during operating intervals to give desired antenna-gain pattern.

Wu, C.↗

An IUE survey of activity in red giants and supergiants

Chromospheric and transition region line activity is examined in apparently single red giants and supergiants using the IUE archives. Low-resolution, large-aperture spectra (mostly short-wavelength) were used to search for variations of emission-line fluxes in time. A series of automatic processing procedures were implemented in order to uniformly calibrate a large number of spectra, fit continua to each of them, determine the fluxes of as many as 18 emission lines, and compare them at different epochs. A method is offered to compute the overall error in the integrated flux, a critical measure of activity, independent of the observing and processing details. This processing was applied to above 120 images of 26 stars taken over a period of 7 yr (1978-1984). Four stars showed UV emission-line flux variations. Alpha Aqr, Beta Peg, and Sigma Oph showed a single enhanced-emission event in all detectable emission lines. Gamma Aql exhibited an increase in the flux level of the O I (1641 A) line in mid-1981 with no comparable change in any other lines. These four stars lie in a region of the H-R diagram in which time-dependent circumstellar absorption lines appear.

Oznovich, I.↗

Spectroscopic CCD surveys for quasars at large redshift. 3: The Palomar Transit Grism Survey catalog

This paper reports the initial results of the Palomar Transit Grism Survey (PTGS). The PTGS was designed to produce a sample of z greater than 2.7 quasars that were identified by well-defined selection criteria. The survey consists of six narrow (approximately equal to 8.5 min wide) strips of sky; the total effective area is 61.47 sq deg. Low-resolution slitless spectra, covering the wavelength range from 4400 to 7500 A, were obtained for approximately 600 000 objects. The wavelength- and flux-calibrated spectra were searched for emission lines with an automatic software algorithm. A total to 1655 emission features in the grism data satisfied our signal-to-noise ratio and equivalent width selection criteria; subsequent slit spectroscopy of the candidates confirmed the existence of 1052 lines (928 different objects). Six groups of emission lines were detected in the survey: Lyman alpha + N V, C IV, C III1, Mg II, H Beta + (O III), and H alpha + (S II). More than two-thirds of the candidates are low-redshift (z less than 0.45) emission-line galaxies; ninety objects are high-redshift quasars (z greater than 2.7) detected via their Lyman alpha + N V emission lines. The survey contains three previously unknown quasars brighter than 17th magnitude; all three have redshifts of approximately equal to 1.3. In this paper we present the observational properties of the survey, the algorithms used to select the emission-line candidates, and the catalog of emission-line objects.

Schneider, Donald P.↗

Device enables calibration of microphones at high sound pressure levels

Coupling device accurately calibrates microphones at high sound pressure intensities. The system which uses a liquid as the coupling medium can operate in an automatic mode by using a standard microphone as a control sensor. Feedback from the standard microphone controls the calibration signal level.

Gillen, A.↗

Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

Czapla-Myers, J.↗

Evaluation of Aqua MODIS and S-NPP VIIRS Thermal Emissive Bands Calibration Stability Using Dome-C

Establishing the calibration consistency between satellite measurements is an essential step in the implementation of a long-term global monitoring plan, which often leads to sensor calibration improvements. The Suomi National Polar-Orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) is a polar-orbiting Earth remote sensing instrument built with a strong Moderate Resolution Imaging Spectroradiometer (MODIS) heritage. The center wavelengths of all VIIRS thermal emissive bands (TEBs) match well with those of MODIS with the exception of VIIRS TEB M15 (10.7μm). Previous work from the MODIS Characterization Support Team (MCST) at the NASA/GSFC used specific Earth surface targets to track the long-term consistency,stability, and relative bias between the two MODIS instruments onboard the Terra and Aqua satellites. Using similar methodologies, this paper evaluates the TEB calibration consistency between the MODIS instruments and S-NPP VIIRS over Dome Concordia (Dome-C). The Dome-C site is uniformly snow-covered and the atmospheric effects are small in the surrounding area. Near-surface air temperature measurements from an Automatic Weather Station (AWS) are used as a reference to track each sensor’s calibration stability and determine the relative bias between the MODIS and VIIRS instruments. The results of this study provide a quantitative assessment of the S-NPP VIIRS TEB mission-long performance.

MODIS↗

An automated secondary standard for calibrating liquid flowmeters

A secondary working standard of flow calibration has been developed to be used in place of a primary weight-time standard, and which can thereby effect a 75 percent reduction in calibration time while maintaining acceptable accuracies. The secondary standard uses six previously calibrated turbine-type flowmeters built into two manifold systems containing automatically switched flow valves. The pair of systems is capable of covering the flow range of 0.0004 to 19 l/s (0.007 to 300 gpm) with the uncertainty in volume flow rate not exceeding + or - 0.25 percent over the range of 0.06 to 19 l/s and not exceeding + or - 0.5 percent over the range 0.0004 to 0.06 1/s. Data reduction and plotting of results are by computer.

Hobart, H. F.↗

An automated secondary standard for calibrating liquid flowmeters

A secondary working standard of flow calibration has been developed to be used in place of a primary weight-time standard, and which can thereby effect a 75 percent reduction in calibration time while maintaining acceptable accuracies. The secondary standard uses six previously calibrated turbine-type flowmeters built into two manifold systems containing automatically switched flow valves. The pair of systems is capable of covering the flow range of 0.0004 to 19 1/s (0.007 to 300 gpm) with the uncertainty in volume flow rate not exceeding plus or minus 0.25 percent over the range 0.06 to 19 1/s and not exceeding plus or minus 0.5 percent over the range 0.0004 to 0.06 1/s. Data reduction and plotting of results are by computer.

Hobart, H. F.↗

Evaluation of space shuttle main engine fluid dynamic frequency response characteristics

In order to determine the POGO stability characteristics of the space shuttle main engine liquid oxygen (LOX) system, the fluid dynamic frequency response functions between elements in the SSME LOX system was evaluated, both analytically and experimentally. For the experimental data evaluation, a software package was written for the Hewlett-Packard 5451C Fourier analyzer. The POGO analysis software is documented and consists of five separate segments. Each segment is stored on the 5451C disc as an individual program and performs its own unique function. Two separate data reduction methods, a signal calibration, coherence or pulser signal based frequency response function blanking, and automatic plotting features are included in the program. The 5451C allows variable parameter transfer from program to program. This feature is used to advantage and requires only minimal user interface during the data reduction process. Experimental results are included and compared with the analytical predictions in order to adjust the general model and arrive at a realistic simulation of the POGO characteristics.

Gardner, T. G.↗