At least 127 records · Page 7

Improved components for engine fuel savings

NASA programs for developing fuel saving technology include the Engine Component Improvement Project for short term improvements in existing air engines. The Performance Improvement section is to define component technologies for improving fuel efficiency for CF6, JT9D and JT8D turbofan engines. Sixteen concepts were developed and nine were tested while four are already in use by airlines. If all sixteen concepts are successfully introduced the gain will be fuel savings of more than 6 billion gallons over the lifetime of the engines. The improvements include modifications in fans, mounts, exhaust nozzles, turbine clearance and turbine blades.

Antl, R. J.↗

A Navier-Stokes study of shock-boundary layer interaction and flow separation inside a transonic compressor

A numerical study to evaluate a three-dimensional Navier-Stokes method as a tool to predict the detailed flowfield inside a low-aspect-ratio compressor at off-design rotor speed has been conducted. The flow field inside a state-of-the-art transonic compressor is used for the purpose of the evaluation. The experimental study shows that the rotor has higher peak efficiency at 90 percent rotor speed than at 100 percent rotor speed. The details of the flow structure inside the low-aspect-ratio compressor (three-dimensional shock structure, shock-boundary layer interaction, tip leakage vortex, etc.) and the overall aerodynamic performance at various operating conditions are numerically analyzed, and the results are compared with the available experimental data. The numerical results also indicate that the rotor has higher peak efficiency at 90 percent rotor speed than at 100 percent rotor speed. This is due to the reduced shock strength and the reduced interactions among passage shock, tip-clearance vortex and blade boundary layer.

Hah, Chunill↗

Rotary blood pump

A rotary blood pump is presented. The pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial, and radial clearances of the blades associated with the flow straightener, inducer portion, impeller portion, and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with crosslinked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

Bozeman, Richard J.↗

Method for Reducing Pumping Damage to Blood

Methods are provided for minimizing damage to blood in a blood pump wherein the blood pump comprises a plurality of pump components that may affect blood damage such as clearance between pump blades and housing, number of impeller blades, rounded or flat blade edges, variations in entrance angles of blades, impeller length, and the like. The process comprises selecting a plurality of pump components believed to affect blood damage such as those listed herein before. Construction variations for each of the plurality of pump components are then selected. The pump components and variations are preferably listed in a matrix for easy visual comparison of test results. Blood is circulated through a pump configuration to test each variation of each pump component. After each test, total blood damage is determined for the blood pump. Preferably each pump component variation is tested at least three times to provide statistical results and check consistency of results. The least hemolytic variation for each pump component is preferably selected as an optimized component. If no statistical difference as to blood damage is produced for a variation of a pump component, then the variation that provides preferred hydrodynamic performance is selected. To compare the variation of pump components such as impeller and stator blade geometries, the preferred embodiment of the invention uses a stereolithography technique for realizing complex shapes within a short time period.

Bozeman, Richard J., Jr.↗

Powerpack Testing of the J2-X Oxidizer Turbopump

The J-2X PPA-2 (Powerpack 2) test series was conducted from February through December 2012 on the A1 test stand at NASA Stennis Space Center in a joint effort between Pratt and Whitney Rocketdyne (PWR) and NASA Marshall Space Flight Center (MSFC). The series consisted of 13 tests for a total hotfire duration close to 6500 seconds. Among the chief test objectives was characterization of the capabilities of the new J-2X turbopumps. This paper concentrates on the test results pertaining specifically to the Oxidizer Turbopump (OTP) operation in liquid oxygen (LOX). The two bladed inducer configuration that was tested had a 0.81% blade height tip clearance and incorporated the B-groove modification to the inducer tunnel outboard of the inducer leading edge. Data was collected on inducer suction performance, pump radial loading, and the pump dynamic environment in LOX. Comparisons were made to prior data collected on two geometrically similar subscale inducers tested in water at NASA MSFC (70% scale) and Concepts NREC (52% scale). In overview, the results of the powerpack testing were consistent with the radial load assessment from the water tests. The inducer performed differently in the other two categories, however. The inducer suction performance capability in LOX was notably improved. This was expected and is probably attributable to thermal suppression head (TSH) effects. While the dynamic environment was similar in most aspects to water test observations, the higher order cavitation (HOC) during the powerpack testing was much more benign.

Jambusaria, Mitul↗

Effect of flight loads on turbofan engine performance deterioration

A significant percentage of high bypass ratio, turbofan engine performance deterioration was caused by an increase in operating clearance between fan/compressor and turbine blades and their outer air seals. These increased clearances resulted from rubs induced by a combination of engine power transients and aircraft flight loads. An analytical technique for predicting the effect of quasi-steady state aircraft flight loads on engine performance deterioration was developed and is presented. Thrust, aerodynamic and inertia loads were considered. Analytical results are shown and compared to actual engine test experience.

Stakolich, E. G.↗

Effect of flight loads on turbofan engine performance deterioration

A significant percentage of high-bypass-ratio turbofan engine performance deterioration is caused by an increase in operating clearance between fan/compressor and turbine blades and their outer air seals. These increased clearances result from rubs induced by a combination of engine power transients and aircraft flight loads. An analytical technique for predicting the effect of quasi-steady state aircraft flight loads on engine performance deterioration has been developed and is presented. Thrust, aerodynamic and inertia loads are considered. Analytical results are shown and compared to actual engine test experience.

Stakolich, E. G.↗

Effects of Double-Leakage Tip Clearance Flow on the Performance of a Compressor Stage with a Large Rotor Tip Gap

Effects of a large rotor tip gap on the performance of a one and half stage axial compressor are investigated in detail with a numerical simulation based on LES and available PIV data. The current paper studies the main flow physics, including why and how the loss generation is increased with the large rotor tip gap. The present study reveals that when the tip gap becomes large, tip clearance fluid goes over the tip clearance core vortex and enters into the next blade's tip gap, which is called double-leakage tip clearance flow. As the tip clearance flow enters into the adjacent blade's tip gap, a vortex rope with a lower pressure core is generated. This vortex rope breaks up the tip clearance core vortex of the adjacent blade, resulting in a large additional mixing. This double-leakage tip clearance flow occurs at all operating conditions, from design flow to near stall condition, with the large tip gap for the current compressor stage. The double-leakage tip clearance flow, its interaction with the tip clearance core vortex of the adjacent blade, and the resulting large mixing loss are the main flow mechanism of the large rotor tip gap in the compressor. When the tip clearance is smaller, flow near the end wall follows more closely with the main passage flow and this double-leakage tip clearance flow does not happen near the design flow condition for the current compressor stage. When the compressor with a large tip gap operates at near stall operation, a strong vortex rope is generated near the leading edge due to the double-leakage flow. Part of this vortex separates from the path of the tip clearance core vortex and travels from the suction side of the blade toward the pressure side of the blade. This vortex is generated periodically at near stall operation with a large tip gap. As the vortex travels from the suction side to the pressure side of the blade, a large fluctuation of local pressure forces blade vibration. Nonsynchronous blade vibration occurs due to this vortex as the frequency of this vortex generation is not the same as the rotor. The present investigation confirms that this vortex is a part of separated tip clearance vortex, which is caused by the double-leakage tip clearance flow.

flow↗

Effect of tip clearance on performance of small axial hydraulic turbine

The first two stages of a six stage liquid oxygen turbine were tested in water. One and two stage performance was determined for one shrouded and two unshrouded blade end configurations over ranges of clearance and blade-jet speed ratio. First stage, two stage, and second stage efficiencies are included as well as the effect of clearance on mass flow for two stage operation.

Boynton, J. L.↗

Tip-Clearance Vortex Characterized With Three-Dimensional Digital Particle Image Velocimetry

An optical measurement technique known as Three-Dimensional Digital Particle Image Velocimetry (3-D DPIV) was used to characterize the tip clearance flow in NASA Glenn Research Center's low-speed axial compressor. 3-D DPIV is a technique in which a stereoscopic imaging system consisting of two cross-correlation cameras is used to record particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Although 3-D DPIV has been used elsewhere, this is the first time it has been used to measure compressor tip clearance flows. In-house modifications of the DPIV system include the use of effective seeding technology and a novel system to perform a priori calibrations at all five measurement planes, greatly reducing facility run time. Computational fluid dynamics predictions, which are used to guide design changes toward improving the efficiency and operating range of turbomachinery, can be verified and improved by comparison with 3-D DPIV measurements of the actual tip clearance flow. This measurement campaign dealt with the characterization of the tip clearance vortex in the first stage of a four-stage axial compressor. The tip clearance vortex is formed in compressors operating with a clearance gap between the moving rotor blade tips and the stationary casing when a leakage flow, forced from the pressure side of the blade over the blade tip, forms a vortical structure on the suction side of the blade. 3-D DPIV is ideally suited to measure the clearance vortex for two reasons: (1) this technique captures the entire blade passage flow at one instant in time, so that wandering of the vortex during the measurement does not smear out velocity gradients in the flow field, and (2) the spanwise component of velocity changes sign across the vortex core, providing a more accurate measurement of the vortex location than was available with previous two-dimensional measurement approaches. These two attributes of the data will enable computational fluid dynamics researchers to validate their predictions to a level of accuracy not previously attainable. In an effort to understand the effects of this flow phenomenon on the operation of the low speed axial compressor, data were acquired at two mass flow coefficients: 0.395 (design operating point) and 0.35 (operating point just above stall). In order to identify the spatial extent, location, and magnitude of the tip clearance vortex for each mass flow condition, data were acquired at five equally spaced spanwise locations, from 90- to 100-percent span. The data presented shows a cross section of the tip clearance vortex at 94-percent span and a mass flow coefficient of 0.395, where the color contours represent the radial velocity component. The blue (flow towards the hub) and red (flow towards the casing) regions illustrate the extent of the tip clearance vortex. The interface between the blue and red regions delineates the location of the vortex core.

John, W. Trevor↗

Heat Transfer and Pressure Distributions on a Gas Turbine Blade Tip

Heat transfer coefficient and static pressure distributions are experimentally investigated on a gas turbine blade tip in a five-bladed stationary linear cascade. The blade is a 2-dimensional model of a first stage gas turbine rotor blade with a blade tip profile of a GE-E(sup 3) aircraft gas turbine engine rotor blade. The flow condition in the test cascade corresponds to an overall pressure ratio of 1.32 and exit Reynolds number based on axial chord of 1.1 x 10(exp 6). The middle 3-blade has a variable tip gap clearance. All measurements are made at three different tip gap clearances of about 1%, 1.5%, and 2.5% of the blade span. Heat transfer measurements are also made at two different turbulence intensity levels of 6.1 % and 9.7% at the cascade inlet. Static pressure measurements are made in the mid-span and the near-tip regions as well as on the shroud surface, opposite the blade tip surface. Detailed heat transfer coefficient distributions on the plane tip surface are measured using a transient liquid crystal technique. Results show various regions of high and low heat transfer coefficient on the tip surface. Tip clearance has a significant influence on local tip beat transfer coefficient distribution. Heat transfer coefficient also increases about 15-20% along the leakage flow path at higher turbulence intensity level of 9.7% over 6.1 %.

Azad, Gm S.↗

WINCLR: a Computer Code for Heat Transfer and Clearance Calculation in a Compressor

One of the concerns during inclement weather operation of aircraft in rain and hail storm conditions is the nature and extent of changes in compressor casing clearance. An increase in clearance affects efficiency while a decrease may cause blade rubbing with the casing. The change in clearance is the result of geometrical dimensional changes in the blades, the casing and the rotor due to heat transfer between those parts and the two-phase working fluid. The heat transfer interacts nonlinearly with the performance of the compressor, and, therefore, the determination of clearance changes necessitates a simultaneous determination of change in performance of the compressor. A computer code the WINCLR has been designed for the determination of casing clearance, that is operated interactively with the PURDU-WINCOF I code designed previously for determining the performance of a compressor. A detailed description of the WINCLR code is provided in a companion report. The current report provides details of the code with an illustrative example of application to the case of a multistage compressor. It is found in the example case that under given ingestion and operational conditions, it is possible for a compressor to undergo changes in performance in the front stages and rubbing in the back stages.

Bose, T. K.↗

JT8D high pressure compressor performance improvement

An improved performance high pressure compressor with potential application to all models of the JT8D engine was designed. The concept consisted of a trenched abradable rubstrip which mates with the blade tips for each of the even rotor stages. This feature allows tip clearances to be set so blade tips run at or near the optimum radius relative to the flowpath wall, without the danger of damaging the blades during transients and maneuvers. The improved compressor demonstrated thrust specific fuel consumption and exhaust gas temperature improvements of 1.0 percent and at least 10 C over the takeoff and climb power range at sea level static conditions, compared to a bill-of-material high pressure compressor. Surge margin also improved 4 percentage points over the high power operating range. A thrust specific fuel consumption improvement of 0.7 percent at typical cruise conditions was calculated based on the sea level test results.

Gaffin, W. O.↗

Energy efficient engine. Low pressure turbine test hardware detailed design report

The low pressure turbine for the energy efficient engine is a five-stage configuration with moderate aerodynamic loading incorporating advanced features of decambered airfoils and extended blade overlaps at platforms and shrouds. Mechanical integrity of 18,000 hours on flowpath components and 36,000 hours on all other components is achieved along with no aeromechanical instabilities within the steady-state operating range. Selection of a large number (156) of stage 4 blades, together with an increased stage 4 vane-to-blade gap, assists in achieving FAR 36 acoustic goals. Active clearance control (ACC) of gaps at blade tips and interstage seals is achieved by fan air cooling judiciously applied at responsive locations on the casing. This ACC system is a major improvement in preventing deterioration of the 0.0381 cm (0.015 in.) clearances required to meet the integrated-core/low-spool turbine efficiency goal of 91.1% and the light propulsion system efficiency goal of 91.7%.

Cherry, D. G.↗

CF6 jet engine performance improvement: New fan

As part of the NASA sponsored engine component improvement program, and fan package was developed to reduce fuel consumption in current CF6 turbofan aircraft engine. The new fan package consist of an improved fan blade, reduced fan tip clearance due to a fan case stiffener, and a smooth fan casing tip shroud. CF6 engine performance and acoustic tests demonstrated the predicted 1.8% improvement in cruise sfc without an increase in engine noise. Power management thrust/fan speed characteristics were defined. Mechanical and structural integrity was demonstrated in model fan rotor photoelastic stress tests, full-size fan blade bench fatigue tests, and CF6 engine bird ingestion, crosswind, and cyclic endurance tests. The fan was certified in the CF6-500c2/E2 engines and is in commerical service on the Boeing 747-200, Douglas DC-10-30, and Atrbus industrie A300B aircraft.

Fasching, W. A.↗

B747/JT9D flight loads and their effect on engine running clearances and performance deterioration; BCAC NAIL/P and WA JT9D engine diagnostics programs

Flight loads on the 747 propulsion system and resulting JT9D blade to outer airseal running clearances during representative acceptance flight and revenue flight sequences were measured. The resulting rub induced clearance changes, and engine performance changes were then analyzed to validate and refine the JT9D-7A short term performance deterioration model.

Olsson, W. J.↗

Energy efficient engine high pressure turbine test hardware detailed design report

The high pressure turbine configuration for the Energy Efficient Engine is built around a two-stage design system. Moderate aerodynamic loading for both stages is used to achieve the high level of turbine efficiency. Flowpath components are designed for 18,000 hours of life, while the static and rotating structures are designed for 36,000 hours of engine operation. Both stages of turbine blades and vanes are air-cooled incorporating advanced state of the art in cooling technology. Direct solidification (DS) alloys are used for blades and one stage of vanes, and an oxide dispersion system (ODS) alloy is used for the Stage 1 nozzle airfoils. Ceramic shrouds are used as the material composition for the Stage 1 shroud. An active clearance control (ACC) system is used to control the blade tip to shroud clearances for both stages. Fan air is used to impinge on the shroud casing support rings, thereby controlling the growth rate of the shroud. This procedure allows close clearance control while minimizing blade tip to shroud rubs.

Halila, E. E.↗

Smoke Studies of Secondary Flows in Bends, Tandem Cascades, and High-turning Configurations

Flow-visualization studies, using smoke, were made of the secondary flows in rectangular bends, tandem cascades, and high-turning configurations. The roll-up of the wall boundary layer of a rectangular bend forms a passage vortex near the suction surface similar to that previously observed for cascades. The vortex so formed then shifts out into the main stream. Because of leading-edge effects, the boundary-layer flows in bends were found to be sufficiently different from the flows in blade rows to make direct application of bend results to blade rows inadvisable. Passage vortices are shown, in the tandem-cascade study, to resist turning with the main stream through which they pass and to disturb the flow in subsequent blade rows. This disturbance may explain in part the appreciable size of the losses sometimes attributed to secondary flows in turbomachines despite the fact that the energy involvement in vortex formation is slight. Tip-flow studies of high-turning blades with relative motion between blades and end wall indicated that if the relative sizes of the passage vortex forces, the tip clearance forces, and the blade-scraping effects are properly controlled, it may be possible to improve the blade-tip loading characteristics in turbomachine.