Search NASA⌕ Search

SEARCH · Search NASA

Results for “bombardment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Secondary electron emission measurements from imidazolium-based ionic liquids

The electron-induced secondary electron emission (SEE) yields of imidazolium-based ionic liquids are presented for primary electron beam energies between 30 and 1000 eV. These results are important for understanding plasma synthesis of nanoparticles in plasma discharges with an ionic liquid electrode. Due to their low vapor pressure and high conductivity, ionic liquids can produce metal nanoparticles in low-pressure plasmas through reduction of dissolved metal salts. In this work, the low vapor pressure of ionic liquids is exploited to directly measure SEE yields by bombarding the liquid with electrons and measuring the resulting currents. The ionic liquids studied are [BMIM][Ac], [EMIM][Ac], and [BMIM][BF 4 ]. The SEE yields vary significantly over the energy range, with maximum yields of around 2 at 200 eV for [BMIM][Ac] and [EMIM][Ac], and 1.8 at 250 eV for [BMIM][BF 4 ]. Molecular orbital calculations indicate that the acetate anion is the likely electron donor for [BMIM][Ac] and [EMIM][Ac], while in [BMIM][BF 4 ], the electrons likely originate from the [BMIM] + cation. The differences in SEE yields are attributed to varying ionization potentials and molecular structures of the ionic liquids. These findings are essential for accurate modeling of plasma discharges and understanding SEE mechanisms in ionic liquids.

ionic liquids↗

Self-consistent description of the halo nature of 31 Ne with continuum and pairing correlations

Here a relativistic structure model has previously been used to predict a halo structure for 31 Ne, consistent with halo signatures from measured reaction cross sections of Ne isotopes bombarding Carbon targets. However, previous attempts to calculate those cross sections with reaction models were missing contributions from resonances and pairing correlations in their structure input. Use a reaction model with our relativistic fully microscopic structure model input to predict these cross sections and momentum distributions and analyze for possible halo signatures. Structure input for exotic Ne isotopes were obtained via the analytical continuation of the coupling constant (ACCC) method based on the relativistic mean field (RMF) theory with Bardeen - Cooper - Schrieffer (BCS) pairing approximation, the RAB approach. Total reaction cross sections, one-neutron removal cross sections, and momentum distributions of breakup reaction products were calculated with a Glauber model using our relativistic structure input. Our predictions of total reaction and one-neutron removal cross sections of 31 Ne on a Carbon target were significantly enhanced compared with those of neighboring Neon isotopes, agreeing with measurements at 240 MeV/nucleon and consistent with a single neutron halo. Furthermore, our calculations of the inclusive longitudinal momentum distribution of the 30 Ne and valence neutron residues from the 31 Ne breakup reaction indicate a dilute density distribution in coordinate space, another halo signature. We give a full description of the halo nature of 31 Ne that includes a self-consistent use of pairing and continuum contributions that makes predictions consistent with reaction cross section measurements. This approach can be utilized to determine the halo structure of other exotic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron beam analysis induces Cl vacancy defects in a NaCl thin film

This work reports on the electron-induced modification of NaCl thin film grown on Ag(110). We show using low energy electron diffraction that electron beam bombardment leads to desorption and formation of Cl vacancy defects on NaCl surface. The topographic structure of these defects is studied using scanning tunneling microscopy (STM) showing the Cl defects as depressions on the NaCl surface. Most of the observed defects are mono-atomic vacancies and are located on flat NaCl terraces. Auger electron spectroscopy confirms the effect of electron exposure on NaCl thin films showing Cl atoms desorption from the surface. Using density functional theory taken into account the van der Waals dispersion interactions, we confirm the observed experimental STM measurements with STM simulation. Furthermore, comparing the adsorption of defect free NaCl and defective NaCl monolayer on Ag(110) surfaces, we found an increase of the adhesion energy and the charge transfer between the NaCl film and the substrate due to the Cl vacancy. In details, the adhesion energy increases between the NaCl film and the metallic Ag substrate from 30.4 meV Å –2 for the NaCl film without Cl vacancy and from 39.5 meV Å –2 for NaCl film with a single Cl vacancy. The charge transfer from the NaCl film to the Ag substrate is enhanced when the vacancy is created, from 0.63e – to 1.25e – .

Materials Science↗

Charge-exchange losses of beam ions in MAST Upgrade: experiments and modelling

Dedicated experiments were performed on MAST Upgrade to study beam-ion losses caused by charge exchange (CX) with edge neutrals. The fuelling was switched from the high-field side to the low-field side mid-discharge. Direct measurements suggest a strong increase in the neutral density around the plasma and a decrease in the beam-ion density, which is qualitatively explained by CX losses. Measurements by a resistive bolometer have suggested particle bombardment during neutral beam injection, providing a unique opportunity to separate CX from other loss mechanisms. To verify and quantify CX losses, the orbit-following code ASCOT, which accounts both for CX neutralization and reionization, was used to simulate beam-particle power loads on the bolometer. Simulations reproduce measured bolometer power loads during high-field-side fuelling, verifying CX losses of approximately 10% of the off-axis beam power. Toroidally symmetric simulations overestimate power loads on the bolometer during low-field-side fuelling, which is explained by toroidal asymmetry in the neutral density distribution, as is demonstrated by toroidally asymmetric simulations. Results suggest significantly higher CX losses during low-field-side fuelling, up to about 50% of off-axis beam power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of silicon carbide as a divertor armor material in DIII-D H-mode discharges

Silicon carbide (SiC) represents a promising but largely untested plasma-facing material (PFM) for next-step fusion devices. In this work, an analytic mixed-material erosion model is developed by calculating the physical (via SDTrimSP) and chemical (via empirical scalings) sputtering yield from SiC, Si, and C. The Si content in the near-surface SiC layer is predicted to increase during D plasma bombardment due to more efficient physical and chemical sputtering of C relative to Si. Silicon erosion from SiC thereby occurs primarily from sputtering of the enriched Si layer, rather than directly from the SiC itself. SiC coatings on ATJ graphite, manufactured via chemical vapor deposition, were exposed to repeated H-mode plasma discharges in the DIII-D tokamak to test this model. The qualitative trends from analytic modeling are reproduced by the experimental measurements, obtained via spectroscopic inference using the S/XB method. Quantitatively the model slightly under-predicts measured erosion rates, which is attributed to uncertainties in the ion impact angle distribution, as well as the effect of edge-localized modes. After exposure, minimal changes to the macroscopic or microscopic surface morphology of the SiC coatings were observed. Compositional analysis reveals Si enrichment of about 10%, in line with expectations from the erosion model. Extrapolating to a DEMO-type device, an order-of-magnitude decrease in impurity sourcing, and up to a factor of 2 decrease in impurity radiation, is expected with SiC walls, relative to graphite, if low C plasma impurity content can be achieved. Furthermore, these favorable erosion properties motivate further investigations of SiC as a low-Z, non-metallic PFM.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Desiccation and Freezing on Microbial Ionizing Radiation Survivability: Considerations for Mars Sample Return

Increasingly, national space agencies are expanding their goals to include Mars exploration with sample return. To better protect Earth and its biosphere from potential extraterrestrial sources of contamination, as set forth in the Outer Space Treaty of 1967, international efforts to develop planetary protection measures strive to understand the danger of cross-contamination processes in Mars sample return missions. We aim to better understand the impact of the martian surface on microbial dormancy and survivability. Radiation resistance of microbes is a key parameter in considering survivability of microbes over geologic times on the frigid, arid surface of Mars that is bombarded by solar and galactic cosmic radiation. We tested the influence of desiccation and freezing on the ionizing radiation survival of six model microorganisms: vegetative cells of two bacteria (Deinococcus radiodurans, Escherichia coli) and a strain of budding yeast (Saccharomyces cerevisiae); and vegetative cells and endospores of three Bacillus bacteria (B. subtilis, B. megaterium, B. thuringiensis). Desiccation and freezing greatly increased radiation survival of vegetative polyploid microorganisms when applied separately, and when combined, desiccation and freezing increased radiation survival even more so. Thus, the radiation survival threshold of polyploid D. radiodurans cells can be extended from the already high value of 25 kGy in liquid culture to an astonishing 140 kGy when the cells are both desiccated and frozen. However, such synergistic radioprotective effects of desiccation and freezing were not observed in monogenomic or digenomic Bacillus cells and endospores, which are generally sterilized by 12 kGy. This difference is associated with a critical requirement for survivability under radiation, that is, repair of genome damage caused by radiation. Deinococcus radiodurans and S. cerevisiae accumulate similarly high levels of the Mn antioxidants that are required for extreme radiation resistance, as do endospores, though they greatly exceed spores in radioresistance because they contain multiple identical genome copies, which in D. radiodurans are joined by persistent Holliday junctions. We estimate ionizing radiation survival limits of polyploid DNA-based life-forms to be hundreds of millions of years of background radiation while buried in the martian subsurface. Our findings imply that forward contamination of Mars will essentially be permanent, and backward contamination is a possibility if life ever existed on Mars.

59 BASIC BIOLOGICAL SCIENCES↗

Examining a hadronic γ-ray scenario for the radiative shell and molecular clouds of the old GeV supernova remnant G298.6−0.0

Abstract Based on the 13.7 yr Fermi-LAT data, Yeung, Bamba, and Sano (2023, PASJ, 75, 384) claimed detection of two γ-ray sources (namely Src-NE and Src-NW) associated with the supernova remnant (SNR) G298.6−0.0, and interpreted it as an old GeV SNR interacting with molecular clouds (MCs). In this follow-up study, we refine the flux measurements below 2 GeV with Fermi-LAT event types of better angular reconstruction. Then, we report our γ-ray spectral fittings and cosmic-ray phenomenology in a hadronic scenario, considering both the shell and MC regions of SNR G298.6−0.0. We confirm that the γ-ray spectra of both Src-NE and Src-NW exhibit spectral breaks, at $1.50_{-0.50}^{+0.60}$ and $0.68_{-0.11}^{+0.32}\:$GeV, respectively. Src-NW has a harder broad-band photon index than Src-NE, suggesting an appreciable difference between the physical separations of their respective emission sites from SNR G298.6−0.0. The cosmic-ray spectrum responsible for Src-NE starts with a minimum energy $E_\mathrm{CR,min}=1.38_{-0.16}^{+0.47}\:$GeV, and has a proton index $\Gamma _\mathrm{CR}=2.57_{-0.21}^{+0.18}$ below the exponential cutoff energy $E_\mathrm{CR,max}=240_{-150}^{+240}\:$GeV. Accordingly, we argue that Src-NE is dominated by the SNR shell, while only a minor portion of lower-energy emission is contributed by the MCs interacting with the SNR. The cosmic-ray population for Src-NW starts at a higher energy such that the ECR, min ratio of Src-NW to Src-NE is ≳2. The high ECR, min, as well as the high cosmic-ray energy density required (∼26 eV cm−3), supports the interpretation that Src-NW is predominantly the γ-ray emission from the farther MCs being bombarded by protons that had earlier escaped from SNR G298.6−0.0. By comparing the high-energy features of G298.6−0.0 with those of analogical SNRs, especially SNR W 28 and SNR W 44, we further constrain the age of SNR G298.6−0.0 to be 10–30 kyr, under the assumption of a purely hadronic scenario.

Astronomy & Astrophysics↗

Interfacial alloying contributions to the magnetic proximity effect in Pt/dysprosium iron garnet

The magnetic proximity effect (MPE), a magnetic response from a heavy metal layer induced by an adjacent magnetic layer, plays an important role in the behavior of heavy-metal/ferro- or ferrimagnet thin film heterostructures. However, in the case of heavy-metal/rare earth iron garnet bilayers the presence and magnitude of the MPE has been debated. We previously reported an MPE in a Pt/dysprosium iron garnet (DyIG) heterostructure where the two layers were grown without breaking vacuum, finding that the magnetic moment present in the Pt layer scales with the magnitude of the DyIG moment and varies nonmonotonically through the DyIG compensation temperature. However, the origin of the magnetic signal from the Pt layer was not identified. In contrast, Pt/DyIG grown with a vacuum break did not exhibit an MPE. Here we investigate the origin of the magnetic moment in the Pt layer using x-ray absorption spectroscopy, x-ray circular dichroism, composition mapping and simulations of ion bombardment. In conclusion, the results are consistent with the presence of an intermixed Fe-Dy-Pt interfacial alloy layer formed during the growth of the Pt on the DyIG and resulting in a measurable MPE.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Final SeaQuest Results on the Flavor Asymmetry of the Proton Light-Quark Sea with Proton-Induced Drell-Yan Process

The Fermilab E906/SeaQuest collaboration performed measurements of the Drell-Yan process using 120 GeV proton beams bombarding liquid hydrogen and liquid deuterium targets. A combined analysis of all collected data was performed to obtain the final results for the 𝜎 𝑝⁢𝑑 /2⁢𝜎 𝑝⁢𝑝 Drell-Yan cross section ratio covering the kinematic region of 0.13 < 𝑥 <0.45. The 𝑥 dependencies of $\bar{d}$(𝑥)/$\bar{𝑢}$⁡(𝑥) and $\bar{d}$(𝑥) $-$ $\bar{𝑢}$⁡(𝑥) are extracted from these cross section ratios. It is found that $\bar{d}$(𝑥) is greater than $\bar{𝑢}$⁡(𝑥) over the entire measured 𝑥 range, with improved statistical accuracy compared to previous measurements. The new results on $\bar{d}$(𝑥)/$\bar{𝑢}$⁡(𝑥) and $\bar{d}$(𝑥) $-$ $\bar{𝑢}$⁡(𝑥) are compared to various parton distribution functions and theoretical calculations.

Leung, C. H. [University of Illinois at Urbana-Cha↗

Direct cross section measurement of 102 Pd ⁢(𝛾,𝑝) and 102 Pd ⁢(𝛾,𝛼) for the astrophysical 𝑝 process

Background: A handful of neutron-deficient stable nuclei, known as the “p nuclei,” cannot be produced through astrophysical neutron capture processes. Instead, some of these nuclei are proposed to be produced by 𝛾-induced reactions on existing r- and s-process seeds. The specific astrophysical site or sites are not yet identified, however, with uncertainties in the cross sections of these 𝛾-induced reactions playing a role. Databases of reaction rates for astrophysical simulations often rely on theoretical statistical model calculations, such as Hauser-Feshbach, for rates where no experimental information is known. However, reasonable variations in the choice of parametrizations of various nuclear properties can create order-of-magnitude variations in the final predicted cross sections and reaction rates, which are then propagated through the models to the predicted final abundances. Purpose: To better constrain these statistical model calculations and ultimately reduce the uncertainties from the nuclear physics on our understanding of the p nuclei, a measurement of the cross sections of 𝛾-induced reactions on the p-nucleus 102 Pd was undertaken. This work represents the first measurement of its kind, using segmented silicon detectors to measure prompt charged particle emission from 𝛾-induced reactions. Methods: Quasimonoenergetic gamma beams from the High Intensity 𝛾 Source facility bombarded an enriched 102 Pd target. A segmented silicon array was arranged to detect the particles emitted from (𝛾,𝑝) and (𝛾,𝛼) reactions. Results: Reaction cross sections were deduced at multiple 𝛾-beam energies between 10 and 19 MeV, and compared to statistical model calculations using talys-1.96. The 102 Pd ⁢(𝛾,𝑝)⁢ 101 Rh reaction cross section was reasonably well reproduced by a subset of photon strength functions and level densities, though the strength to the ground state of 101 Rh was underestimated at higher incident gamma energies. The 102 Pd ⁢(𝛾,𝛼)⁢ 98 Ru was in general overpredicted by the various alpha-nucleus optical model potentials. Conclusions: While the theoretical cross sections used to model the (𝛾,𝑝) reactions for the p process may be reasonable, a more careful approach is needed in the case of (𝛾,𝛼). Further work to probe gamma-induced reaction cross sections at and near the p nuclei is warranted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Ehrlich-Schwoebel barrier contribution to the self-organized formation of ordered surface patterns on Ge(001)

Normal-incidence 1-keV Ar + ion bombardment leads to amorphization and ultrasmoothing of Ge at room temperature, but at elevated temperatures the Ge surface remains crystalline and is unstable to the formation of self-organized nanoscale patterns of ordered pyramid-shaped pits. The physical phenomenon distinguishing the high-temperature patterning from room-temperature ultrasmoothing is believed to be a surface instability due to the Ehrlich-Schwoebel barrier for diffusing vacancies and adatoms, which is not present on the amorphous material. This real-time grazing-incidence small-angle x-ray scattering study compares smoothing of a prepatterned Ge sample at room temperature with patterning of an initially flat Ge sample at an elevated temperature. In both experiments, when the nanoscale structures are relatively small in height, the average kinetics can be explained by a linear theory. Furthermore, the linear theory coefficients, indicating surface stability or instability, were extracted for both experiments. A comparison between the two measurements allows estimation of the contribution of the Ehrlich-Schwoebel barrier to the self-organized formation of ordered nanoscale patterns on crystalline Ge surfaces.

36 MATERIALS SCIENCE↗

Determining the average prompt-fission-neutron multiplicity for Pu 239 ( n , f ) via a Pu 240 ( α , α ' f ) surrogate reaction

The average prompt-fission-neutron multiplicity ν ¯ is of significance in the areas of nuclear theory, nuclear nonproliferation, and nuclear energy. In this work, the surrogate-reaction method has been used for the first time to indirectly determine ν ¯ for Pu 239 ( n , f ) via Pu 240 ( α , α ' f ) reactions. A Pu 240 target was bombarded with a beam of 53.9-MeV α particles. Scattered α particles, fission products, and neutrons were measured with the NeutronSTARS detector array. Values of ν ¯ were obtained for a continuous range of equivalent incident neutron energies between 0.25 and 26.25 MeV, and the results agree well with direct neutron measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure of 30 Mg explored via in-beam γ-ray spectroscopy

In the island of inversion, ground states of neutron-rich sd-shell nuclei exhibit strong admixtures of intruder configurations from the fp shell. The nucleus 30 Mg, located at the boundary of the island of inversion, serves as a cornerstone to track the structural evolution as one approaches this region. Spin-parity assignments for excited states in 30 Mg, especially negative-parity levels, have yet to be established. In the present work, the nuclear structure of 30Mg was investigated by in-beam gamma-ray spectroscopy mainly focusing on firm spin-parity determinations. High-intensity rare-isotope beams of 31 Mg, 32 Mg, 34 Si, and 35 P bombarded a Be target to induce nucleon removal reactions populating states in 30 Mg. Gamma rays were detected by the state-of-the-art gamma-ray tracking array GRETINA. For the direct one-neutron removal reaction, final-state exclusive cross sections and parallel momentum distributions were deduced. Multi-nucleon removal reactions from different projectiles were exploited to gain complementary information. With the aid of the parallel momentum distributions, an updated level scheme with revised spin-parity assignments was constructed. Spectroscopic factors associated with each state were also deduced. Results were confronted with large-scale shell-model calculations using two different effective interactions, showing excellent agreement with the present level scheme. Furthermore, a marked difference in the spectroscopic factors indicates that the full delineation of the transition into the island of inversion remains a challenge for theoretical models.

20 ≤ A ≤ 38↗

Long-lived isomeric states and quasiparticle band structures in neutron-rich 162,164 Gd nuclei from β decay

Neutron-rich nuclei 162,164 Eu were produced by bombarding a proton beam on a 238 U target at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory and mass separating the 162,164 Eu products. New level schemes and new γ-ray transitions of the daughters 162,164 Gd were identified from β-decay spectroscopy studies. Additionally, half-lives of the 162,164 Eu were remeasured to clarify the previous ambiguous results. Two quasiparticle band structures were built and compared with neighboring nuclei. The β and γ bands were extended in 162 Gd and a γ band was extended in 164 Gd. Half-lives of the isomeric states at (6 - ) 1449 keV in 162 Gd and (4 - ) 1096 keV in 164 Gd were measured to be 99(3) μs and 0.56(3) μs, respectively. Projected shell model calculations were performed and found to be in good agreement with all of the experimental data.

150 ≤ A ≤ 189↗

Possible quenching of static neutron pairing near the N=98 deformed shell gap: Rotational structures in 160,161 Gd

A 160 Gd beam was accelerated to an energy of 1000 MeV and, separately, bombarded thick targets of 154 Sm and 164 Dy in order to observe neutron-rich, rare-earth nuclei via deep-inelastic collision processes. Gammasphere was utilized to observe g-ray emissions. Here, many new states and transitions were observed in 160 Gd as a result of so-called "unsafe" Coulomb excitation. The ground-state band in 160 Gd has been extended to I π = 20 + and a rotational band based on the K π = 4 + state, previously associated with a hexadecapole vibration, was observed up to 18 + . The quasiparticle configuration of the K π = 4 + band has been determined, and its unusual alignment behavior may result from a possible quenching of static neutron pairing. In addition, the band based on the [523]5/2 quasineutron orbital in 161 Gd was extended from 11/2 – to 33/2 – , and also displays the same unusual alignment behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗