Search NASA⌕ Search

SEARCH · Search NASA

Results for “brain imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Physiological and Subjective Responses of Pilots during Advanced Air Mobility Flight Testing with Automated Systems

Aviation is constantly evolving, mostly due to the integration of automated systems into the National Airspace System. This presents a host of challenges and opportunities. NASA’s Advanced Air Mobility (AAM) project has taken a significant leap forward with a research flight test led by the Integration of Automated Systems (IAS) sub-project. This effort focused on assessing automated flight deck algorithms essential for supporting high-density Urban Air Mobility (UAM) operations. Carrying out a two-ship flight test in UAM Maturity Level 4 scenarios, the team evaluated state-of-the-art algorithms, including Hazard Perception and Avoidance (HPA) and flight path management (FPM) systems. This paper investigates into pilots’ physiological and subjective responses during the flight scenarios conducted. In collaboration with Lockheed Martin Advanced Technology Laboratories (ATL), we collected and analyzed live-flight biometric data using eye tracking, mobile brain imaging, and heart rate sensors. The study provides insights into pilots’ workload and cognitive engagement while navigating automated tools, leveraging both biometric data and post-encounter subjective assessments. The research highlights the interaction between human operators and automated systems, contributing valuable lessons learned about gathering human data in live-flight environments. The knowledge acquired from this study enhances our understanding of human factors in automated flight and informs future studies attempting to undertake similar feats.

Kevin J. Monk↗

Physiological and Subjective Responses of Pilots During Advanced Air Mobility Flight Testing With Automated Systems

Aviation is constantly evolving, mostly due to the integration of automated systems into the National Airspace System. This presents a host of challenges and opportunities. NASA's Advanced Air Mobility (AAM) project has taken a significant leap forward with a research flight test led by the Integration of Automated Systems (IAS) sub-project. This effort focused on assessing automated flight deck algorithms essential for supporting high-density Urban Air Mobility (UAM) operations. Carrying out a two-ship flight test in UAM Maturity Level 4 scenarios, the team evaluated state-of-the-art algorithms, including Hazard Perception and Avoidance (HPA) and flight path management (FPM) systems. This presentation focuses on results of pilots' physiological and subjective responses during the flight scenarios conducted. In collaboration with Lockheed Martin Advanced Technology Laboratories (ATL), we collected and analyzed live-flight biometric data using eye tracking, mobile brain imaging, and heart rate sensors. The data provides insights into pilots' workload and cognitive engagement while navigating automated tools, leveraging both biometric data and post-encounter subjective assessments. The research highlights the interaction between human operators and automated systems, contributing valuable lessons learned about gathering human data in live-flight environments. The knowledge acquired from this endeavor enhances our understanding of human factors in automated flight and informs future studies attempting to undertake similar feats.

air mobility↗

Robust Estimation of Electron Density From Anatomic Magnetic Resonance Imaging of the Brain Using a Unifying Multi-Atlas Approach

Purpose: To develop a reliable method to estimate electron density based on anatomic magnetic resonance imaging (MRI) of the brain. Methods and Materials: We proposed a unifying multi-atlas approach for electron density estimation based on standard T1- and T2-weighted MRI. First, a composite atlas was constructed through a voxelwise matching process using multiple atlases, with the goal of mitigating effects of inherent anatomic variations between patients. Next we computed for each voxel 2 kinds of conditional probabilities: (1) electron density given its image intensity on T1- and T2-weighted MR images; and (2) electron density given its spatial location in a reference anatomy, obtained by deformable image registration. These were combined into a unifying posterior probability density function using the Bayesian formalism, which provided the optimal estimates for electron density. We evaluated the method on 10 patients using leave-one-patient-out cross-validation. Receiver operating characteristic analyses for detecting different tissue types were performed. Results: The proposed method significantly reduced the errors in electron density estimation, with a mean absolute Hounsfield unit error of 119, compared with 140 and 144 (P<.0001) using conventional T1-weighted intensity and geometry-based approaches, respectively. For detection of bony anatomy, the proposed method achieved an 89% area under the curve, 86% sensitivity, 88% specificity, and 90% accuracy, which improved upon intensity and geometry-based approaches (area under the curve: 79% and 80%, respectively). Conclusion: The proposed multi-atlas approach provides robust electron density estimation and bone detection based on anatomic MRI. If validated on a larger population, our work could enable the use of MRI as a primary modality for radiation treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy

Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Demographic, Genetic, and Imaging Variables Associated With Brain Resilience and Cognitive Resilience to Pathological Tau in Patients With Alzheimer Disease

Importance: Better understanding is needed of the degree to which individuals tolerate Alzheimer disease (AD)-like pathological tau with respect to brain structure (brain resilience) and cognition (cognitive resilience). Objective: To examine the demographic (age, sex, and educational level), genetic (APOE-ε4 status), and neuroimaging (white matter hyperintensities and cortical thickness) factors associated with interindividual differences in brain and cognitive resilience to tau positron emission tomography (PET) load and to changes in global cognition over time. Design, setting, an participants: In this cross-sectional, longitudinal study, tau PET was performed from June 1, 2014, to November 30, 2017, and global cognition monitored for a mean [SD] interval of 2.0 [1.8] years at 3 dementia centers in South Korea, Sweden, and the United States. The study included amyloid-β-positive participants with mild cognitive impairment or AD dementia. Data analysis was performed from October 26, 2018, to December 11, 2019. Exposures: Standard dementia screening, cognitive testing, brain magnetic resonance imaging, amyloid-β PET and cerebrospinal fluid analysis, and flortaucipir (tau) labeled with fluor-18 (18F) PET. Main outcomes and measures: Separate linear regression models were performed between whole cortex [18F]flortaucipir uptake and cortical thickness, and standardized residuals were used to obtain a measure of brain resilience. The same procedure was performed for whole cortex [18F]flortaucipir uptake vs Mini-Mental State Examination (MMSE) as a measure of cognitive resilience. Bivariate and multivariable linear regression models were conducted with age, sex, educational level, APOE-ε4 status, white matter hyperintensity volumes, and cortical thickness as independent variables and brain and cognitive resilience measures as dependent variables. Linear mixed models were performed to examine whether changes in MMSE scores over time differed as a function of a combined brain and cognitive resilience variable. Results: A total of 260 participants (145 [55.8%] female; mean [SD] age, 69.2 [9.5] years; mean [SD] MMSE score, 21.9 [5.5]) were included in the study. In multivariable models, women (standardized β = -0.15, P = .02) and young patients (standardized β = -0.20, P = .006) had greater brain resilience to pathological tau. Higher educational level (standardized β = 0.23, P < .001) and global cortical thickness (standardized β = 0.23, P < .001) were associated with greater cognitive resilience to pathological tau. Linear mixed models indicated a significant interaction of brain resilience × cognitive resilience × time on MMSE (β [SE] = -0.235 [0.111], P = .03), with steepest slopes for individuals with both low brain and cognitive resilience. Conclusions and relevance: Results of this study suggest that women and young patients with AD have relative preservation of brain structure when exposed to neocortical pathological tau. Interindividual differences in resilience to pathological tau may be important to disease progression because participants with both low brain and cognitive resilience had the most rapid cognitive decline over time.

60 APPLIED LIFE SCIENCES↗

Electroencephalographic imaging of higher brain function

High temporal resolution is necessary to resolve the rapidly changing patterns of brain activity that underlie mental function. Electroencephalography (EEG) provides temporal resolution in the millisecond range. However, traditional EEG technology and practice provide insufficient spatial detail to identify relationships between brain electrical events and structures and functions visualized by magnetic resonance imaging or positron emission tomography. Recent advances help to overcome this problem by recording EEGs from more electrodes, by registering EEG data with anatomical images, and by correcting the distortion caused by volume conduction of EEG signals through the skull and scalp. In addition, statistical measurements of sub-second interdependences between EEG time-series recorded from different locations can help to generate hypotheses about the instantaneous functional networks that form between different cortical regions during perception, thought and action. Example applications are presented from studies of language, attention and working memory. Along with its unique ability to monitor brain function as people perform everyday activities in the real world, these advances make modern EEG an invaluable complement to other functional neuroimaging modalities.

Non-NASA Center↗

Concept of an upright wearable positron emission tomography imager in humans

Abstract Background Positron Emission Tomography ( PET ) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_ PET ) and conducted tests in phantoms and four human volunteers. Methods Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET / CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET / CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROI s. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. Conclusion To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view.

60 APPLIED LIFE SCIENCES↗

Evaluation of MRI and cannabinoid type 1 receptor PET templates constructed using DARTEL for spatial normalization of rat brains

Purpose: Image registration is one prerequisite for the analysis of brain regions in magnetic-resonance-imaging (MRI) or positron-emission-tomography (PET) studies. Diffeomorphic anatomical registration through exponentiated Lie algebra (DARTEL) is a nonlinear, diffeomorphic algorithm for image registration and construction of image templates. The goal of this small animal study was (1) the evaluation of a MRI and calculation of several cannabinoid type 1 (CB1) receptor PET templates constructed using DARTEL and (2) the analysis of the image registration accuracy of MR and PET images to their DARTEL templates with reference to analytical and iterative PET reconstruction algorithms. Methods: Five male Sprague Dawley rats were investigated for template construction using MRI and [{sup 18}F]MK-9470 PET for CB1 receptor representation. PET images were reconstructed using the algorithms filtered back-projection, ordered subset expectation maximization in 2D, and maximum a posteriori in 3D. Landmarks were defined on each MR image, and templates were constructed under different settings, i.e., based on different tissue class images [gray matter (GM), white matter (WM), and GM + WM] and regularization forms (“linear elastic energy,” “membrane energy,” and “bending energy”). Registration accuracy for MRI and PET templates was evaluated by means of the distance between landmark coordinates. Results: The best MRI template was constructed based on gray and white matter images and the regularization form linear elastic energy. In this case, most distances between landmark coordinates were <1 mm. Accordingly, MRI-based spatial normalization was most accurate, but results of the PET-based spatial normalization were quite comparable. Conclusions: Image registration using DARTEL provides a standardized and automatic framework for small animal brain data analysis. The authors were able to show that this method works with high reliability and validity. Using DARTEL templates together with nonlinear registration algorithms allows for accurate spatial normalization of combined MRI/PET or PET-only studies.

60 APPLIED LIFE SCIENCES↗

Kinetic modeling of [ 18 F]V AT , a novel radioligand for positron emission tomography imaging vesicular acetylcholine transporter in non‐human primate brain

Abstract Molecular imaging of vesicular acetylcholine transporter ( VACh T) in the brain provides an important cholinergic biomarker for the pathophysiology and treatment of dementias including Alzheimer's disease. In this study, kinetics modeling methods were applied and compared for quantifying regional brain uptake of the VACh T‐specific positron emission tomography radiotracer, ((−)‐(1‐(‐8‐(2‐fluoroethoxy)‐3‐hydroxy‐1,2,3,4‐tetrahydronaphthalen‐2‐yl)piperidin‐4‐yl)(4‐fluorophenyl)‐methanone) ([ 18 F]V AT ) in macaques. Total volume distribution ( V T ) estimates were compared for one‐tissue compartment model (1 TCM ), two‐tissue compartment model (2 TCM ), Logan graphic analysis (LoganA IF ) and multiple linear analysis (M A 1) with arterial blood input function using data from three macaques. Using the cerebellum‐hemispheres as the reference region with data from seven macaques, three additional models were compared: reference tissue model ( RTM ), simplified RTM ( SRTM ), and Logan graphic analysis (Logan REF ). Model selection criterion indicated that a) 2 TCM and SRTM were the most appropriate kinetics models for [ 18 F]V AT ; and b) S RTM was strongly correlated with 2 TCM (Pearson's coefficients r > 0.93, p < 0.05). Test–retest studies demonstrated that [ 18 F]V AT has good reproducibility and reliability ( TRV < 10%, ICC > 0.72). These studies demonstrate [ 18 F]V AT is a promising VACh T positron emission tomography tracer for quantitative assessment of VACh T levels in the brain of living subjects. image

Jin, Hongjun↗

Infrared Imaging System for Studying Brain Function

A proposed special-purpose infrared imaging system would be a compact, portable, less-expensive alternative to functional magnetic resonance imaging (fMRI) systems heretofore used to study brain function. Whereas a typical fMRI system fills a large room, and must be magnetically isolated, this system would fit into a bicycle helmet. The system would include an assembly that would be mounted inside the padding in a modified bicycle helmet or other suitable headgear. The assembly would include newly designed infrared photodetectors and data-acquisition circuits on integrated-circuit chips on low-thermal-conductivity supports in evacuated housings (see figure) arranged in multiple rows and columns that would define image coordinates. Each housing would be spring-loaded against the wearer s head. The chips would be cooled by a small Stirling Engine mounted contiguous to, but thermally isolated from, the portions of the assembly in thermal contact with the wearer s head. Flexible wires or cables for transmitting data from the aforementioned chips would be routed to an integrated, multichannel transmitter and thence through the top of the assembly to a patch antenna on the outside of the helmet. The multiple streams of data from the infrared-detector chips would be sent to a remote site, where they would be processed, by software, into a three-dimensional display of evoked potentials that would represent firing neuronal bundles and thereby indicate locations of neuronal activity associated with mental or physical activity. The 3D images will be analogous to current fMRI images. The data would also be made available, in real-time, for comparison with data in local or internationally accessible relational databases that already exist in universities and research centers. Hence, this system could be used in research on, and for the diagnosis of response from the wearer s brain to physiological, psychological, and environmental changes in real time. The images would also be stored in a relational database for comparison with corresponding responses previously observed in other subjects.

Mintz, Frederick↗

Kinetic Analysis and Quantification of [ 11 C]Martinostat for in Vivo HDAC Imaging of the Brain

We report that epigenetic mechanisms mediated by histone deacetylases (HDACs) have been implicated in a wide-range of CNS disorders and may offer new therapeutic opportunities. In vivo evaluation of HDAC density and drug occupancy has become possible with [ 11 C]Martinostat, which exhibits selectivity for a subset of class I/IIb HDAC enzymes. In this study, we characterize the kinetic properties of [ 11 C]Martinostat in the nonhuman primate (NHP) brain in preparation for human neuroimaging studies. The goal of this work was to determine whether classic compartmental analysis techniques were appropriate and to further determine if arterial plasma is required for future NHP studies. Using an arterial plasma input function, several analysis approaches were evaluated for robust outcome measurements. [ 11 C]Martinostat showed high baseline distribution volume (V T ) ranging from 29.9 to 54.4 mL/cm 3 in the brain and large changes in occupancy (up to 99%) with a blocking dose approaching full enzyme saturation. An averaged nondisplaceable tissue uptake (VND) of 8.6 ± 3.7 mL/cm 3 suggests high specific binding of [ 11 C]Martinostat. From a two-tissue compartment model, [ 11 C]Martinostat exhibits a high K 1 (averaged K 1 of 0.65 mL/cm 3 /min) and a small k 4 (average of 0.0085 min –1 ). In conclusion, our study supports that [ 11 C]Martinostat can be used to detect changes in HDAC density and occupancy in vivo and that simplified analysis not using arterial blood could be appropriate.

59 BASIC BIOLOGICAL SCIENCES↗

Radiotracer Synthesis and PET Imaging Evaluation for Brain Histamine Receptors

The goal of the project is to synthesize([ 11 C]RWJ393059, a carbon-11 labeled antagonist for the histamine H3 receptor, using a procedure developed by Johnson and Johnson chemists. and to evaluate the pharmacokinetics and specificity of this radiotracer for the histamine H3 receptor in the baboon model using the ECAT HR+ PET scanner at Brookhaven.

99 GENERAL AND MISCELLANEOUS↗

Imaging Nicotine in Rat Brain Tissue by Use of Nanospray Desorption Electrospray Ionization Mass Spectrometry

Imaging mass spectrometry offers simultaneous detection of drugs, drug metabolites and endogenous substances in a single experiment. This is important when evaluating effects of a drug on a complex organ system such as the brain, where there is a need to understand how regional drug distribution impacts function. Nicotine is an addictive drug and its action in the brain is of high interest. Here we use nanospray desorption electrospray ionization, nano-DESI, imaging to discover the localization of nicotine in rat brain tissue after in vivo administration of nicotine. Nano-DESI is a new ambient technique that enables spatially-resolved analysis of tissue samples without special sample pretreatment. We demonstrate high sensitivity of nano-DESI imaging that enables detection of only 0.7 fmole nicotine per pixel in the complex brain matrix. Furthermore, by adding deuterated nicotine to the solvent, we examined how matrix effects, ion suppression, and normalization affect the observed nicotine distribution. Finally, we provide preliminary results suggesting that nicotine localizes to the hippocampal substructure called dentate gyrus.

dentate gyrus↗

Non-invasive imaging of the levels and effects of glutathione on the redox status of mouse brain using electron paramagnetic resonance imaging

Glutathione (GSH) is the most abundant non-protein thiol that buffers reactive oxygen species in the brain. GSH does not reduce nitroxides directly, but in the presence of ascorbates, addition of GSH increases ascorbate-induced reduction of nitroxides. In this study, we used electron paramagnetic resonance (EPR) imaging and the nitroxide imaging probe, 3-methoxycarbonyl-2,2,5,5-tetramethyl-piperidine-1-oxyl (MCP), to non-invasively obtain spatially resolved redox data from mouse brains depleted of GSH with diethyl maleate compared to control. Based on the pharmacokinetics of the reduction reaction of MCP in the mouse heads, the pixel-based rate constant of its reduction reaction was calculated as an index of the redox status in vivo and mapped as a “redox map”. The obtained redox maps from control and GSH-depleted mouse brains showed a clear change in the brain redox status, which was due to the decreased levels of GSH in brains as measured by a biochemical assay. We observed a linear relationship between the reduction rate constant of MCP and the level of GSH for both control and GSH-depleted mouse brains. Using this relationship, the GSH level in the brain can be estimated from the redox map obtained with EPR imaging. - Highlights: • Redox status of glutathione-depleted mouse brain was examined with EPR imaging. • Redox status of mouse brain changed depending on glutathione (GSH) levels in brains. • Linear relationship between GSH levels and redox status in brains was found. • Using this relation, estimation of GSH levels in brains is possible from EPR images.

60 APPLIED LIFE SCIENCES↗

Repeated exposure of the developing rat brain to magnetic resonance imaging did not affect neurogenesis, cell death or memory function

Research highlights: {yields} The effect of MRI on the developing brain is a matter of debate. {yields} Repeated exposure to MRI did not affect neurogenesis. {yields} Memory function was not affected by repeated MRI during development. {yields} Neither late gestation nor young postnatal brains were affected by MRI. {yields} Repeated MRI did not cause cell death in the neurogenic region of the hippocampus. -- Abstract: The effect of magnetic fields on the brain is a matter of debate. The objective of this study was to investigate whether repeated exposure to strong magnetic fields, such as during magnetic resonance imaging (MRI), could elicit changes in the developing rat brain. Embryonic day 15 (E15) and postnatal day 14 (P14) rats were exposed to MRI using a 7.05 T MR system. The animals were anesthetized and exposed for 35 min per day for 4 successive days. Control animals were anesthetized but no MRI was performed. Body temperature was maintained at 37 {sup o}C. BrdU was injected after each session (50 mg/kg). One month later, cell proliferation, neurogenesis and astrogenesis in the dentate gyrus were evaluated, revealing no effects of MRI, neither in the E15, nor in the P14 group. DNA damage in the dentate gyrus in the P14 group was evaluated on P18, 1 day after the last session, using TUNEL staining. There was no difference in the number of TUNEL-positive cells after MRI compared with controls, neither in mature neurons, nor in newborn progenitors (BrdU/TUNEL double-labeled cells). Novel object recognition was performed to assess memory function 1 month after MRI. There was no difference in the recognition index observed after MRI compared with the control rats, neither for the E15, nor for the P14 group. In conclusion, repeated exposure to MRI did not appear to affect neurogenesis, cell death or memory function in rats, neither in late gestation (E15-E18) nor in young postnatal (P14-P17) rats.

60 APPLIED LIFE SCIENCES↗