Search NASA⌕ Search

SEARCH · Search NASA

Results for “building application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Salt Hydrate Eutectic Thermal Energy Storage for Building Thermal Regulation (Final Technical Report)

Thermal energy storage is anticipated to play an important role in developing the power grid of the future - a power grid that meets increasing demands of users, is resistant to disruptions, but also allows for greater penetration of renewable resources. Specifically, thermal energy storage materials can be integrated into HVAC systems and building envelopes, where they can be used to shift power demands for building climate control from periods of peak demand to periods of low demand. Phase change materials (PCMs) are compelling as low-cost, high energy density thermal energy storage materials for building thermal management. However, there is a lack of high performance low-cost PCMs within the specific temperature ranges which would most effectively allow for power load shifting. Inorganic salt hydrates represent a promising class of PCMs, but their inherent limitations cause them to be currently unavailable for reliable building applications. The overarching goals of this research effort are to: 1) Discover low-cost, high volumetric density salt hydrate eutectic PCMs to store low-quality heat (10 to 40 °C); 2) Introduce a high thermal conductivity matrix to reduce the time constant for energy storage to ~0.1 to 1 hr, incorporate nucleation catalysts to decrease undercooling, and utilize microencapsulation and shape stabilization approaches, minimizing moisture loss/gain, mitigating phase separation, and maintaining stable melting behavior over the lifetime of the compounds; 3) Evaluate the impact these systems have on peak load shifting, and the potential for overall energy savings under different climatic scenarios and building configurations. These goals will be achieved by an integrated research program consisting of six cohesive research subtasks: 1) Materials discovery of eutectic salt hydrate PCMs by using computationally predicted thermodynamic equilibria, coupled with high-throughput experimental validation, 2) Rapid experimental screening of nucleation catalysts identified through robust computational databases, 3) Embedding salt hydrate PCM into a low cost and scalable high conductivity matrix, 4) Microencapsulation of salt hydrate microspheres using hybrid inorganic-polymer microencapsulation approach, 5) Shape stabilization by thermoreversible salt hydrate salogels, and 6) Analysis of end-use using thermal simulations, and characterization of mock-up energy storage finished components.

25 ENERGY STORAGE↗

Performance of Gas-Engine Driven Heat Pump Unit

Air-conditioning (cooling) for buildings is the single largest use of electricity in the United States (U.S.). This drives summer peak electric demand in much of the U.S. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated technologies (TAT), such as natural gas engine-driven heat pumps (GHP), can provide overall peak load reduction and electric grid relief for summer peak demand. GHP offers an attractive opportunity for commercial building owners to reduce electric demand charges and operating expenses. Engine-driven systems have several potential advantages over conventional single-speed or single-capacity electric motor-driven units. Among them are variable speed operation, high part load efficiency, high temperature waste heat recovery from the engine, and reduced annual operating costs (SCGC 1998). Although gas engine-driven systems have been in use since the 1960s, current research is resulting in better performance, lower maintenance requirements, and longer operating lifetimes. Gas engine-driven systems are typically more expensive to purchase than comparable electric motor-driven systems, but they typically cost less to operate, especially for commercial building applications. Operating cost savings for commercial applications are primarily driven by electric demand charges. GHP operating costs are dominated by fuel costs, but also include maintenance costs. The reliability of gas cooling equipment has improved in the last few years and maintenance requirements have decreased (SCGC 1998, Yahagi et al. 2006). Another advantage of the GHP over electric motor-driven is the ability to use the heat rejected from the engine during heating operation. The recovered heat can be used to supplement the vapor compression cycle during heating or to supply other process loads, such as water heating. The use of the engine waste heat results in greater operating efficiency compared to conventional electric motor-driven units (SCGC 1998). In Japan, many hundreds of thousands of natural gas-driven heat pumps have been sold (typically 40,000 systems annually) (Yahagi et al. 2006). The goal of this program is to develop dependable and energy efficient GHPs suitable for U.S. commercial rooftop applications (the single largest commercial product segment). This study describes the laboratory performance evaluation of an integrated 10-ton GHP rooftop unit (a 900cc Daihatsu-Aisin natural gas engine) which uses R410A as the refrigerant (GEDAC No.23). ORNL Thermally-Activated Heat Pump (TAHP) Environmental Chambers were used to evaluate this unit in a controlled laboratory environment.

03 NATURAL GAS↗

Spray Manufacturing Thermal Insulation Composites

Cellulose-based thermal insulation materials present significant potential for modern green building applications due to their inherent carbon sequestration properties. However, traditional manufacturing of composites often results in the limited thermal insulation performance and embodied carbon footprint due to an increased density from material shrinkage and higher energy consumption during the water-based slurry drying process. Here, we report solvent spraying coupled with dry powder feedstock to manufacture highly porous silica/straw insulation composites. The manufactured composite exhibits negligible shrinkage with the density of 0.08 g/cm 3 , thermal conductivity of 27.8 mW/(m·K), flexural modulus of 3.1 MPa, and compressive modulus of 0.89 MPa. Additionally, the prepared composite demonstrates fire retardancy (burning rate of 0.5 mm/min) and recyclability (99%). Furthermore, this solvent-spraying strategy opens up opportunities of energy-efficient insulation materials for carbon-sequestration building sectors.

36 MATERIALS SCIENCE↗

Research Opportunities in High Energy Density Laboratory Plasmas on the NDCX-II Facility

Intense beams of heavy ions offer a very attractive tool for fundamental research in high energy density physics and inertial fusion energy science. These applications build on the significant recent advances in the generation, compression and focusing of intense heavy ion beams in the presence of a neutralizing background plasma. Such beams can provide uniform volumetric heating of the target during a time-scale shorter than the hydrodynamic response time, thereby enabling a significant suite of experiments that will elucidate the underlying physics of dense, strongly-coupled plasma states, which have been heretofore poorly understood and inadequately diagnosed, particularly in the warm dense matter regime. The innovations, fundamental knowledge, and experimental capabilities developed in this basic research program is also expected to provide new research opportunities to study the physics of directly-driven ion targets, which can dramatically reduce the size of heavy ion beam drivers for inertial fusion energy applications. Experiments examining the behavior of thin target foils heated to the warm dense matter regime began at the Lawrence Berkeley National Laboratory in 2008, using the Neutralized Drift Compression Experiment - I (NDCX-I) facility, and its associated target chamber and diagnostics. The upgrade of this facility, called NDCX-II, will enable an exciting set of scientific experiments that require highly uniform heating of the target, using Li{sup +} ions which enter the target with kinetic energy in the range of 3 MeV, slightly above the Bragg peak for energy deposition, and exit with energies slightly below the Bragg peak. This document briefly summarizes the wide range of fundamental scientific experiments that can be carried out on the NDCX-II facility, pertaining to the two charges presented to the 2008 Fusion Energy Science Advisory Committee (FESAC) panel on High Energy Density Laboratory Plasmas (HEDLP). These charges include: (1) Identify the compelling scientific opportunities for research in fundamental HEDLP that could be investigated using existing and planned facilities in support of the Office of Fusion Energy Sciences and the National Nuclear Security Administration/Defense Program missions; and (2) Identify the scientific issues of implosion and target design that need to be addressed to make the case for inertial fusion energy as a potential future energy source. Compelling research opportunities of high intellectual value that can be carried out on the NDCX-II experimental facility are briefly summarized below, grouped into four main research areas. Page 4 lists several national and internationally-attended user workshops that have provided much of the input for the experimental campaigns describe below. More detailed information can be provided upon request.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MAN-004 Design Standards Manual

At Sandia National Laboratories in New Mexico (SNL/NM), the design, construction, operation, and maintenance of facilities is guided by industry standards, a graded approach, and the systematic analysis of life cycle benefits received for costs incurred. The design of the physical plant must ensure that the facilities are "fit for use," and provide conditions that effectively, efficiently, and safely support current and future mission needs. In addition, SNL/NM applies sustainable design principles, using an integrated whole-building design approach, from site planning to facility design, construction, and operation to ensure building resource efficiency and the health and productivity of occupants. The safety and health of the workforce and the public, any possible effects on the environment, and compliance with building codes take precedence over project issues, such as performance, cost, and schedule. These design standards generally apply to all disciplines on all SNL/NM projects. Architectural and engineering design must be both functional and cost-effective. Facility design must be tailored to fit its intended function, while emphasizing low-maintenance, energy-efficient, and energy-conscious design. Design facilities that can be maintained easily, with readily accessible equipment areas, low maintenance, and quality systems. To promote an orderly and efficient appearance, architectural features of new facilities must complement and enhance the existing architecture at the site. As an Architectural and Engineering (A/E) professional, you must advise the Project Manager when this approach is prohibitively expensive. You are encouraged to use professional judgment and ingenuity to produce a coordinated interdisciplinary design that is cost-effective, easily contractible or buildable, high-performing, aesthetically pleasing, and compliant with applicable building codes. Close coordination and development of civil, landscape, structural, architectural, fire protection, mechanical, electrical, telecommunications, and security features is expected to ensure compatibility with planned functional equipment and to facilitate constructability. If portions of the design are subcontracted to specialists, delivery of the finished design documents must not be considered complete until the subcontracted portions are also submitted for review. You must, along with support consultants, perform functional analyses and programming in developing design solutions. These solutions must reflect coordination of the competing functional, budgetary, and physical requirements for the project. During design phases, meetings between you and the SNL/NM Project Team to discuss and resolve design issues are required. These meetings are a normal part of the design process. For specific design-review requirements, see the project-specific Design Criteria. In addition to the design requirements described in this manual, instructive information is provided to explain the sustainable building practice goals for design, construction, operation, and maintenance of SNL/NM facilities. Please notify SNL/NM personnel of design best practices not included in this manual, so they can be incorporated in future updates.

42 ENGINEERING↗

Sandia National Laboratories Facilities Management and Operations Center Design Standards Manual

At Sandia National Laboratories in New Mexico (SNL/NM), the design, construction, operation, and maintenance of facilities is guided by industry standards, a graded approach, and the systematic analysis of life cycle benefits received for costs incurred. The design of the physical plant must ensure that the facilities are "fit for use," and provide conditions that effectively, efficiently, and safely support current and future mission needs. In addition, SNL/NM applies sustainable design principles, using an integrated whole-building design approach, from site planning to facility design, construction, and operation to ensure building resource efficiency and the health and productivity of occupants. The safety and health of the workforce and the public, any possible effects on the environment, and compliance with building codes take precedence over project issues, such as performance, cost, and schedule. These design standards generally apply to all disciplines on all SNL/NM projects. Architectural and engineering design must be both functional and cost-effective. Facility design must be tailored to fit its intended function, while emphasizing low-maintenance, energy-efficient, and energy-conscious design. Design facilities that can be maintained easily, with readily accessible equipment areas, low maintenance, and quality systems. To promote an orderly and efficient appearance, architectural features of new facilities must complement and enhance the existing architecture at the site. As an Architectural and Engineering (A/E) professional, you must advise the Project Manager when this approach is prohibitively expensive. You are encouraged to use professional judgment and ingenuity to produce a coordinated interdisciplinary design that is cost-effective, easily contractible or buildable, high-performing, aesthetically pleasing, and compliant with applicable building codes. Close coordination and development of civil, landscape, structural, architectural, fire protection, mechanical, electrical, telecommunications, and security features is expected to ensure compatibility with planned functional equipment and to facilitate constructability. If portions of the design are subcontracted to specialists, delivery of the finished design documents must not be considered complete until the subcontracted portions are also submitted for review. You must, along with support consultants, perform functional analyses and programming in developing design solutions. These solutions must reflect coordination of the competing functional, budgetary, and physical requirements for the project. During design phases, meetings between you and the SNL/NM Project Team to discuss and resolve design issues are required. These meetings are a normal part of the design process. For specific design-review requirements, see the project-specific Design Criteria. In addition to the design requirements described in this manual, instructive information is provided to explain the sustainable building practice goals for design, construction, operation, and maintenance of SNL/NM facilities. Please notify SNL/NM personnel of design best practices not included in this manual, so they can be incorporated in future updates. You must convey all documents describing work to the SNL/NM Project Manager in both hard copy and in an electronic format compatible with the SNL/NM-prescribed CADD and other software packages, and in accordance with a SNL/NM approved standard format. Print all hard copy versions of submitted documents (excluding drawings and renderings) double-sided when practical.

42 ENGINEERING↗

Application-Driven Creation of Building Metadata Models with Semantic Sufficiency

Semantic metadata models such as Brick, RealEstateCore, Project Haystack, and BOT promise to simplify and lower the cost of developing software for smart buildings, enabling the widespread deployment of energy efficiency applications. However, creating these models remains a challenge. Despite recent advances in creating models from existing digital representations like point labels and architectural models, there is still no feedback mechanism to ensure that the human input to these methods results in a model that can actually support the desired software. In this paper, we introduce the notion of semantic sufficiency, a practical principle for semantic metadata model creation that asserts that a model is "finished" when it contains the metadata necessary to support a given set of applications. To support semantic sufficiency, we design a standard representation for capturing application metadata requirements and a templating system for generating common metadata model components with limited user input. We then construct an iterative model creation workflow that integrates metadata requirements to direct the model creation effort, and present several novel optimizations that increase the model utility while minimizing the effort by a human operator. These new abstractions for model creation and validation lower model development costs and ensure the utility of the resulting model, thus facilitating the adoption of intelligent building applications.

applications↗

The Global Precipitation Measurement (GPM) Mission's Scientific Achievements and Societal Contributions: Reviewing Four Years of Advanced Rain and Snow Observations

Precipitation represents a life-critical energy and hydrologic exchange between the Earth’s atmosphere and its surface. As such, knowledge of where, when, and how much rain and snow falls is essential for scientific research and societal applications. Building on the 17-year success of the Tropical Rainfall Measurement Mission (TRMM), the Global Precipitation Measurement (GPM) Core Observatory (GPM-CO) is the first U.S. National Aeronautical and Space Administration (NASA) satellite mission specifically designed with sensors to observe the structure and intensities of both rain and falling snow. The GPM-CO has proved to be a worthy successor to TRMM, extending and improving high-quality active and passive microwave observations across all times of day. The GPM-CO launched in early 2014, is a joint mission between NASA and the Japanese Aerospace Exploration Agency (JAXA), with sensors that include the NASA-provided GPM Microwave Imager and the JAXA-provided Dual-frequency Precipitation Radar. These sensors were devised with high accuracy standards enabling them to be used as a reference for inter-calibrating a constellation of partner satellite data. These intercalibrated partner satellite retrievals are used with infrared data to produce merged precipitation estimates at temporal scales of 30 minutes and spatial scales of 0.1° x 0.1°. Precipitation estimates from the GPM-CO and partner constellation satellites, provided in near real time and later reprocessed with all ancillary data, are an indispensable source of precipitation data for operational and scientific users. Advances have been made using GPM data, primarily in improving sensor calibration, retrieval algorithms, and ground validation measurements, and used to further our understanding of the characteristics of liquid and frozen precipitation and the science of water and hydrological cycles for climate/weather forecasting. These advances have extended to societal benefits related to water resources, operational numerical weather prediction, hurricane monitoring, prediction, and disaster response, extremes, and disease.

Applications↗

Chapter 3: Power Conversion Technologies: The Advent of Power-to-Gas, Power-to-Liquid, and Power-to-Heat

Decreasing levelized costs of renewable electricity coupled with expanding deployment are enabling a rapid reduction in the carbon intensity of the electrical grid. However, this transition is occurring more slowly in other sectors, including transportation and manufacturing. Power-to-X technologies provide a means to accelerate this transition in those sectors by converting renewable electricity into chemical energy and heat. In this chapter, we provide an overview of the existing and emerging Power-to-X technologies covering the production of methane (hydrogen is covered in Chapter 5) (i.e. Power-to-Gas), chemicals and fuels (e.g. ammonia, carbon monoxide, ethylene, methanol, ethanol, and formic acid), and heat (e.g. for industrial and building applications); discuss the overarching and technology-specific challenges and opportunities; and highlight the implications of deployment of Power-to-X technologies on power generation. We emphasize that Power-to-X technologies do exist today at various stages of development and commercialization and that a transition to lower carbon intensity for the transportation and manufacturing sectors is possible, but it requires immense growth of the electrical grid and appropriate systems design and operations.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Flame retardant biogenic building insulation materials from hemp fiber

Biogenic thermal insulation materials are in high demand because of its carbon-sequestration nature. However, high flammability, moisture condensation, and relatively high thermal conductivity of biogenic material are major concerns for sustainable building applications. In this study, we report the fire-retardant cellulose xerogel insulation nanocomposites derived from hemp fiber recycling and silica xerogel, in which the boric acid treatment improves its fire retardancy. The as-prepared materials show a low thermal conductivity of 31.3 mW/m K, high flexural modulus of 665 MPa, hydrophobicity with the water contact angle of 115°, and fire retardancy with 30% weight loss over a period of burning time 10 min. Overall, this work provides an effective method for the synthesis of fire-retardant biogenic thermal insulation materials and shows a promising way for next-generation bio-based insulation materials.

36 MATERIALS SCIENCE↗

Tailoring biogenic straw insulation from additive manufacturing

In the pursuit of carbon-storing materials that could help accomplish high levels of building sustainability, wheat straw has emerged as a promising alternative to fossil fuel-based building materials. Straw is 100% biodegradable and abundant agricultural waste used in the construction 400 years ago, and it has been reported to have the lowest embodied carbon when measured against other typical insulating materials. Here, in this study, we report additive manufacturing of carbon-sequestration insulation panel materials by upcycling cellulose fibrils from wheat straw. Cellulose obtained from alkaline and 2,2,6,6-tetramethylpiperidine-1-oxyl radical-mediated oxidation shows thermal conductivity of 0.036 W m -1 K -1 , alongside elastic and flexural modulus of 900 MPa and 502 MPa, respectively. In addition, an in-situ hydrophobic treatment in the cellulose-based insulation panels is achieved with an average water contact angle of 133.7° Furthermore, the extrusion-based additive manufacturing of a 3D-printable ink obtained by mixing the cellulose and silica aerogel precursor is accomplished, with the printed material exhibiting structural integrity, thus showing great potential towards the development of state-of-the-art, sustainable materials for carbon-sequestration building applications.

36 MATERIALS SCIENCE↗

Parallelized POD-based suboptimal economic model predictive control of a state-constrained Boussinesq approximation

Motivated by an energy efficient building application, we want to optimize a quadratic cost functional subject to the Boussinesq approximation of the Navier-Stokes equations and to bilateral state and control constraints. Since the computation of such an optimal solution is numerically costly, we design an efficient strategy to compute a sub-optimal (but applicationally acceptable) solution with significantly reduced computational effort. We employ an economic Model Predictive Control (MPC) strategy to obtain a feedback control. The MPC sub-problems are based on a linear-quadratic optimal control problem subjected to mixed control and state constraints and a convection-diffusion equation, reduced with proper orthogonal decomposition. Finally, to solve each sub-problem, we apply a primal-dual active set strategy. The method can be fully parallelized, which enables the solution of large problems with real-world parameters.

97 MATHEMATICS AND COMPUTING↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Impact of Off-Design CHP Performance on the Optimal Sizing and Dispatch on Hybrid Renewable-CHP Distributed Energy Resources

The maturation of distributed energy resources (DER) has prompted the exploration of their deployment in commercial building applications due to their potential to supply energy at lower costs and emissions rates compared to centralized generation. While several software tools exist for evaluating the techno-economic potential of integrated renewable energy and combined heat and power (CHP) systems for distributed generation applications, many suffer from poor accuracy in capturing off-design (part load and changes in ambient air temperature and pressure) performance characteristics of microturbines, combustion turbines, or internal combustion engines. Thus, this paper presents a methodology for integrating these off-design characteristics in the mixed-integer linear program within REopt, a hybrid DER screening tool. The economic impact of the CHP off-design performance is observed through several application studies of various hybrid system configurations in different climates. Each study indicates how CHP off-design performance influences optimal sizing and dispatch decisions and therefore overall system economic value. We observe through case studies that modeling without the off-design effects, depending on the CHP prime mover and site, can result in Net Present Value predictions of hybrid systems that can be overoptimistic in frequently hot climates (up to 52%), too conservative in frequently cold climates (up to 11%), or unaffected (+/-1%) in temperate climates. Cases also highlight several advantages of hybrid systems relative to non-hybrid systems such as total economic value and the systems' ability to mitigate potentially negative consequences attributed to off-design performance.

ambient de-rate↗

H 2 BZmacropa-NCS: A Bifunctional Chelator for Actinium-225 Targeted Alpha Therapy

Actinium-225 ( 225 Ac) is one of the most promising radionuclides for targeted alpha therapy (TAT). With a half-life of 9.92 days and a decay chain that emits four high-energy α particles, 225 Ac is well-suited for TAT when conjugated to macromolecular targeting vectors that exhibit extended in vivo circulation times. The implementation of 225 Ac in these targeted constructs, however, requires a suitable chelator that can bind and retain this radionuclide in vivo. Previous work has demonstrated the suitability of a diaza-18-crown-6 macrocyclic chelator H 2 macropa for this application. Building upon these prior efforts, in this study, two rigid variants of H 2 macropa, which contain either one (H 2 BZmacropa) or two (H 2 BZ 2 macropa) benzene rings within the macrocyclic core, were synthesized and investigated for their potential use for 225 Ac TAT. The coordination chemistry of these ligands with La 3+ , used as a nonradioactive model for Ac 3+ , was carried out. Both NMR spectroscopic and X-ray crystallographic studies of the La 3+ complexes of these ligands revealed similar structural features to those found for the related complex of H 2 macropa. Thermodynamic stability constants of the La 3+ complexes, however, were found to be 1 and 2 orders of magnitude lower than those of H 2 macropa for H 2 BZmacropa and H 2 BZ 2 macropa, respectively. The decrease in thermodynamic stability was rationalized via the use of density functional theory calculations. 225 Ac radiolabeling and serum stability studies with H 2 BZmacropa showed that this chelator compares favorably with H 2 macropa. Based on these promising results, a bifunctional version of this chelator, H 2 BZmacropa-NCS, was synthesized and conjugated to the antibody codrituzumab (GC33), which targets the liver cancer biomarker glypican-3 (GPC3). The resulting GC33-BZmacropa conjugate and an analogous GC33-macropa conjugate were evaluated for their 225 Ac radiolabeling efficiencies, antigen-binding affinities, and in vivo biodistribution in HepG2 liver cancer tumor-bearing mice. Although both conjugates were comparably effective in their radiolabeling efficiencies, [ 225 Ac]Ac-GC33-BZmacropa showed slightly poorer serum stability and biodistribution than [ 225 Ac]Ac-GC33-macropa. Altogether, these results establish H2BZmacropa-NCS as a new bifunctional chelator for the preparation of 225 Ac radiopharmaceuticals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An All-Ceramic, Anisotropic, and Flexible Aerogel Insulation Material

To exploit the high-temperature superinsulation potential of anisotropic thermal management materials, the incorporation of ceramic aerogel into the aligned structural networks is indispensable. Yet, the long-standing obstacle to exploring ultralight superinsulation ceramic aerogels is the inaccessibility of its mechanical elasticity, stability, and anisotropic thermal insulation. Here, we report a recoverable, flexible ceramic fiber-aerogel composite with anisotropic lamellar structure, where the interfacial cross-linking between ceramic fiber and aerogel is important in its superinsulation performance. The resulting ultralight aerogel composite exhibits a density of 0.05 g/cm 3 , large strain recovery (over 50%), and low thermal conductivity (0.0224 W m –1 K –1 ), while its hydrophobicity is achieved by in situ trichlorosilane coating with the water contact angle of 135°. The hygroscopic tests of such aerogel composites demonstrate a reversible thermal insulation. The mechanical elasticity and stability of the anisotropic composites, with its soundproof performance, shed light on the low-cost superelastic aerogel manufacturing with scalability for energy saving building applications.

36 MATERIALS SCIENCE↗

Tailoring Nanoporous Silica and Natural Straw Structural Insulation Composites

Nanoporous silica exhibits ultralow thermal conductivity as a result of its nanoscale pore size, high pore volume, and specific surface area. In this study, we report the self-assembled surfactant-templated synthesis of nanoporous silica, which is integrated with cellulose fibers derived from natural straw to manufacture high thermal insulation and mechanically robust nanocomposites. The nanocomposite shows a low thermal conductivity of 22.5 mW/(m·K), a compressive modulus of 0.93 MPa, and a hydrophobicity with a water contact angle of 125°. Moreover, we observed a marked reduction in water absorption capacity and a carbon footprint of 0.21 kg CO 2 equiv/kg. Here, this study provides a pathway toward the development of nanoporous structural insulation materials for energy-efficient building applications.

36 MATERIALS SCIENCE↗