Search NASA⌕ Search

SEARCH · Search NASA

Results for “building operations optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Deep-Learning-Based Multi-Timescale Load Forecasting in Buildings: Opportunities and Challenges from Research to Deployment

Electricity load forecasting for buildings and campuses is becoming increasingly important as the penetration of distributed energy resources (DERs) grows. Efficient operation and dispatch of DERs require reasonably accurate predictions of future energy consumption in order to conduct near-real-time optimized dispatch of on-site generation and storage assets. Electric utilities have traditionally performed load forecasting for load pockets spanning large geographic areas, and therefore, forecasting has not been a common practice by buildings and campus operators. Given the growing trends of research and prototyping in the grid-interactive efficient buildings domain, characteristics beyond simple algorithm forecast accuracy are important in determining the algorithm's true utility for smart buildings. Other characteristics include the overall design of the deployed architecture and the operational efficiency of the forecasting system. In this work, we present a deep-learning-based load forecasting system that predicts the building load at 1-hour intervals for 18 hours in the future. We also discuss challenges associated with the real-time deployment of such systems as well as the research opportunities presented by a fully functional forecasting system that has been developed within the National Renewable Energy Laboratory's Intelligent Campus program.

building load forecasting↗

Operation and Optimization of Microwave-Heated Continuous-Flow Microfluidics

Microwave (MW) technology can be powerful for electrification and process intensification but limited fundamental understanding of scalability and design principles hinders its effective use. In this work, we build a continuous-flow microreactor inside a commercial single-mode MW applicator and the corresponding computational fluid dynamics model to simulate the temperature profile. The model is in good agreement with experiments for various microreactor dimensions and operating conditions. The model indicates that MW heating is greatly influenced by reactor geometry as well as the operating parameters. We observe a strong correlation between parameters and develop a gradient boost regression tree model to predict the outlet temperature accurately. This model is then applied to optimize the dimensions and operating conditions to maximize the outlet temperature and energy efficiency, resulting in a Pareto optimal. We demonstrate computationally and experimentally that it is possible to surpass the Pareto optimal and achieve an energy efficiency of ~90% or greater at temperatures relevant for liquid-phase chemistry via salting of the solvent. The present methodology can be applied to other complex MW reactors. Lastly, the combined numerical and experimental approach provides insights into and a framework for scale-up and optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VOLTTRON/volttron-pnnl-aems

The Autonomous Energy Management Software (AEMS) system will continuously optimize the operations of the distributed energy resources in the small and medium size commercial building by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. Initially, AEMS system will manage rooftop air conditioners and heat pumps but it can be extended in the future to manage, hot water heaters, storage (battery and thermal), electric vehicle charging and monitoring solar photovoltaic. AEMS support both energy efficiency and grid service features.

Bleeker, Amelia [Pacific Northwest National Labora↗

Modeling the Environmental Impact of Air Traffic Operations

There is increased interest to understand and mitigate the impacts of air traffic on the climate, since greenhouse gases, nitrogen oxides, and contrails generated by air traffic can have adverse impacts on the climate. The models described in this presentation are useful for quantifying these impacts and for studying alternative environmentally aware operational concepts. These models have been developed by leveraging and building upon existing simulation and optimization techniques developed for the design of efficient traffic flow management strategies. Specific enhancements to the existing simulation and optimization techniques include new models that simulate aircraft fuel flow, emissions and contrails. To ensure that these new models are beneficial to the larger climate research community, the outputs of these new models are compatible with existing global climate modeling tools like the FAA's Aviation Environmental Design Tool.

Chen, Neil↗

Data and Multistage Optimization for the New Grid

Three essential capabilities for using exascale computing resources on next generation power grid applications are: generating large renewable energy datasets, modeling damage and operations during and after extreme events, and employing multi-stage optimization for infrastructure planning. Powerscenarios, developed as part of the ExaSGD project, addresses these capabilities by enabling users to build synthetic wind farms for large test systems using numerical weather prediction-based data sources. We share examples of using Powerscenarios to build out wind farms on the ACTIVSg2000 test system, to enable simulated operations and emergency asset allocation during a hurricane strike, and to compute multi-stage infrastructure buildouts.

economic dispatch↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OPER: Optimality-Guided Embedding Table Parallelization for Large-scale Recommendation Model

With the sharp increasing volume of user data, Deep Learning Recommendation Model (DLRM) becomes an indispensable infrastructure in large technology companies. However, large-scale DLRM on the multi-GPU platform is still inefficient due to unbalanced workload partitioning and intensive inter-GPU communication. To this end, we propose OPER, an OPtimality guided Embedding table placement for large-scale Recommendation model training and inference. OPER explores the potential of mitigating remote memory access latency in DLRM through fine-grained embedding table placement. Specifically, OPER proposes a theoretical modeling that builds up the relationship between EMT placement and the embedding communication latency in both training and inference. OPER proves the NP hardness of finding the optimal embedding table placement and proposes a heuristic algorithm that yields near optimal placement. OPER implements a SHMEM-based embedding table training system and a unified embedding index mapping to support fine-grained embedding table sharding and placement. Comprehensive experiments reveal that OPER achieves on average 3.4× and 5.1× speedup on training and inference respectively over state-of-the-art DLRM frameworks.

Wang, Zheng↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Cloud-Control of Legacy Building Automation System: A case study

As Internet of Things devices and cloud-based platforms become more mature, Energy Management and Information Systems (EMIS) are increasingly gaining momentum in the building industry. In large commercial buildings, Fault-Detection and Diagnostic (FDD) and energy information systems (EIS) are now established technologies with tens of providers and thousands of deployment sites across North America. The new frontier for the EMIS technology is now represented by control systems that use advanced system optimization (ASO) methods to improve the operations of the HVAC system. Given the complexity of the integration of such systems with the existing building automation systems (BAS) and the higher risk involved with direct control of the HVAC, these systems are still emerging in the market. This paper presents the results of a project in which a start-up company partnered with a research institution to develop a cloud-based software EMIS solution and deployed it in a university campus in California. The software system included advanced sensing, data acquisition, storage and advanced control and analytics applications developed on top of the native BAS. The new platform controls ten buildings on the campus and the FDD and the ASO applications deployed on this platform were able to generate energy savings of up to 35% and 25% in certain buildings for each functionality respectively. Where the platform did not save energy, it improved building service (air quality). Lessons learned include the importance of collaborating with and training the building operators and evaluating whether the legacy system can work reliably with the new technology.

Prakash, Anand Krishnan↗

The effect of lighting environment on task performance in buildings – A review

The effects of indoor environmental conditions on human health, satisfaction, and performance have been the focal point of research for decades. This paper reviews and summarizes the impact of lighting environment on task performance, specifically for the built environment audience. Existing studies included a variety of performance tests on cognitive performance and perception, visual acuity and reaction, memory, reasoning, and labor productivity. Illuminance, luminance ratio and correlated color temperature were found to affect performance in different ways, reflecting the impact of experimental techniques, conditions, performance evaluation methods used and data analysis methods. These were reviewed and categorized, with discussion on limitations related to sample size, modeling approach, carryover effects and other factors affecting individual differences in performance, with recommendations for future improvement. Although no universal conclusions can be made, in general, task performance seems to improve with higher illuminances, contrast ratios in the range of 7–11:1 (while always making sure that glare will not occur in the space) and higher correlated color temperature, while spectral tuning in the red or blue wavelengths has also shown positive effects. To obtain more generic evidence, future studies should be more consistent in terms of experimental procedures and overall light conditions, and also consider the effects of vertical illuminance, daylight provision/control, and outside views on task performance. Finally, studying performance with multi-factorial designs in a human-centered optimized manner (such as deploying variable lighting scenarios optimized for various tasks) can lead to deeper understanding of lighting effects on task performance, and ultimately to improved lighting design and operation in buildings overall.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Transfer Operators in Algebraic Two-Level Methods for Nonsymmetric and Indefinite Problems

Consider an algebraic two-level method applied to the 𝑛-dimensional linear system 𝐴⁢𝒙 = 𝒃 using fine-space preconditioner (i.e., “relaxation” or “smoother”) 𝑀, with 𝑀 ≈ 𝐴, restriction and interpolation 𝑅 and 𝑃, and algebraic coarse-space operator 𝐴 𝑐 : = 𝑅 ∗ ⁢𝐴⁢𝑃. Then, what are the best possible transfer operators 𝑅 and 𝑃 of a given dimension 𝑛 𝑐 < 𝑛? Brannick et al. [12] showed that when 𝐴 and 𝑀 are Hermitian positive definite (HPD), the optimal interpolation is such that its range contains the 𝑛 𝑐 smallest generalized eigenvectors of the matrix pencil (𝐴, 𝑀). Recently, in Ali et al. [5] we generalized this framework to the non-HPD setting, by considering both right (interpolation) and left (restriction) generalized eigenvectors of (𝐴, 𝑀) and defining corresponding nonsymmetric transfer operators {𝑅#, 𝑃#}. Tight convergence bounds for {𝑅#, 𝑃#} are derived in spectral radius, as well as a proof of pseudo-optimality. Note, {𝑅#, 𝑃#} are typically complex valued, which is not practical for real-valued problems. Here, in this work, we build on [5], first characterizing all inner products in which the coarse-space correction defined by {𝑅#, 𝑃#} is orthogonal. We then develop tight two-level convergence bounds in these norms, and prove that the underlying transfer operators {𝑅#, 𝑃#} are genuinely optimal. As a special case, our theory both recovers and extends the HPD results from [12]. Finally, we show how to construct optimal, real-valued transfer operators in the case of that 𝐴 and 𝑀 are real valued, but are not HPD. Numerical examples arising from a discretized advection-reaction equation, wave-equation, and Stokes equations are used to verify and illustrate the theory.

97 MATHEMATICS AND COMPUTING↗

ISRU Pilot Excavator - Development of Autonomous Excavation Algorithms

The ISRU Pilot Excavator (IPEx) is a Space Technology Mission Directorate (STMD) Game Changing Development (GCD) project to develop a robotic excavator to demonstrate excavation of up to 10 metric tons of lunar regolith. IPEx is based on the Regolith Advanced Surface Systems Operations Robot (RASSOR) excavator developed at NASA Kennedy Space Center (KSC) and utilizes a counter rotating bucket drum concept to balance excavation forces for use on reduced gravity planetary bodies. To take advantage of the counter rotating bucket drum mechanism, work is being done to develop new autonomous excavation strategies and algorithms. Referred to as “Auto-dig”, these algorithms will allow IPEx to excavate, drive, and deliver its target mass of 10 metric tons of lunar regolith during an 11-day mission semi-autonomously. Due to bandwidth and latency constraints teleoperation will be kept to a minimum, with operators periodically confirming and verifying the excavator’s high-level tasks and operations. While the work to develop optimized autodig solutions is ongoing at KSC, early tests have yielded interesting results that have led to the discovery of additional risks that need to be mitigated in autonomous excavation. Testing has also encouraged the development of new software and visualization tools that provide real-time insight into excavation loads during operation, allowing faster development and helping build better intuition to the excavation process. These tools will help in the pursuit to develop fully optimized digging algorithms that are robust enough to handle hazards such as rocks or irregular terrain.

B. C. Buckles↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PD21A680: Additive Manufacturing Process Optimization and Qualification FY21 Year-end Report

This project builds upon knowledge gained from previous projects on Additive Manufacturing (AM) operation, process control and monitoring, repeatability, and process improvement. This project will exclusively focus on metal powder bed additive manufacturing (PBAM). Objective 1: Advance metal powder bed AM R&D capabilities. Perform enhanced R&D on increased build volumes and throughput, safety and handling controls, process monitoring, and diagnostics with a focus on production end-states. Objective 2: Build upon knowledge gained from previous PDRD projects to develop deeper understanding of process controls, essential for transitioning metal AM processes for future applications. Objective 3: Maintain business development and research advantages through collaborations with external industry and university partners.

36 MATERIALS SCIENCE↗

Sensor and Actuator Attacks on Hierarchical Control Systems with Domain-Aware Operator Theory

Cyber-Physical Systems (CPSs) provide opportunities for cyber attacks to have physical impacts. Advanced Persistent Threats (APTs) are a subclass of cyber threats that act stealthily to avoid detection and enable long-term attacks. Here, we build on our past work in APT modelling to combine deception-based sensor bias attacks and direct actuator manipulations in attacks against a hierarchical control system. That past work used the Koopman operator to develop a data-driven, domain-aware, optimization-based attacker model. Using an expansion of this model, we compute several different attacks, including multiple simultaneous attacks, against a high-fidelity commercial building emulator and compare the impacts of those attacks to each other. One next step of interest is to construct a defender system, built on the same modelling approach, designed to detect and mitigate such attacks.

koopman operator, Cyber-Physical Security, machine↗

Artificial Intelligence for Data Center Operations (AIOps): Cooperative Research and Development (Final Report)

High performance computing data centers will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence and machine learning approaches provide the means to improve HPC data center operational efficiency, by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. NREL has developed methods of real-time collection, aggregation and streaming of these data in the ESIF HPC Data Center and has collected a significant dataset of relevant metrics across computer systems, racks, environmental, building and utility sources for research into various predictive analytics problems. HPE's Advanced Technology Group (ATG) is doing comprehensive research into exascale monitoring and management for High Performance Computing (HPC) systems (hereinafter HPE's Data Monitoring/ Management Technology). NREL and HPE will collaborate to add Artificial Intelligence (AI) to NREL's real-time data collection/ aggregation/ streaming system and HPE's Data Monitoring/ Management System, with the goal of improving the operational efficiency of NREL's Energy Systems Integration Facility (ESIF) HPC Data Center through data analytics on both historical and real-time data from IT systems and facilities operations. This collaboration will consist of efforts in Data Management, Data Analytics, and AI/ML Optimization for both manual and autonomous intervention in data center operations. This will be a multi-year, multi-staged effort with a goal towards building capabilities for an Advanced Smart Facility, and demonstration of these techniques in the NREL ESIF HPC Data Center.

97 MATHEMATICS AND COMPUTING↗