Search NASA⌕ Search

SEARCH · Search NASA

Results for “building thermal systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Enhancing Building Energy Efficiency through Advanced Sizing and Dispatch Methods for Energy Storage

Energy storage and electrification of buildings hold great potential for future decarbonization. However, there are several technical and economic barriers that prevent large-scale adoption and integration of energy storage in buildings. These barriers include integration with building control systems, high capital costs, and the necessity to identify and quantify value streams for different stakeholders. To overcome these obstacles, it is crucial to develop advanced sizing and dispatch methods to assist planning and operational decision-making for integrating energy storage in buildings. This work develops simple and flexible optimal sizing and dispatch framework for thermal energy storage (TES) and battery energy storage (BES) systems in large-scale office building. The optimal sizes of TES, BES, as well as other building assets are determined in a joint manner instead of sequentially to avoid sub-optimal solutions. The interaction between the sizing at the planning stage and hourly or sub-hourly dispatch at the operating stage is explicitly modeled. The solution is determined considering both capital costs in optimal sizing and operational benefits in optimal dispatch. Comprehensive assessments are performed using simulation studies to quantify potential energy, economic, and emission benefits by different utility tariffs and climate locations, to improve our understanding of the techno-economic performance of different TES and BES systems, and to identify barriers for adopting energy storage for buildings. Finally, the proposed framework will provide guidance to a broad range of stakeholders to properly design energy storage in buildings and maximizes potential benefits, thereby advancing affordable building energy storage deployment and helping us accelerating the transition towards a cleaner and more equitable energy economy.

Yu, Mingyung↗

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

Design screening and analysis of gas-fired ammonia-based chemisorption heat pumps for space heating in cold climate

Thermally-driven ammonia-based chemisorption heat pumps (CSHP) have the potential to provide high-efficiency space heating in cold climates. Using the reversible chemical bond between sorbent salt and ammonia, CSHP thermochemically pumps heat from the cold ambient to the end-uses of space heating at 50 °C. The heating coefficient of performance (COP) of a CSHP largely depends on the selection of the sorbent salts, cycle configuration, and the system operation. This study uses a thermodynamic model to investigate the performance of six CSHP system configurations, including four single-effect and two double-effect cycles. The feasibility and performance of 121 available NH 3 /salt reactions are studied for each configuration. The thermal COP of the cycles and the primary energy COP of the gas-fired CSHP systems are evaluated assuming 50 °C supply temperature for building space heating and the optimal system designs are identified. The highest thermal COP for single-effect and double-effect cycles under -25 °C ambient temperatures are predicted to be 1.22 and 1.57, respectively. The corresponding primary energy COPs are above 1.0 and 1.15, which are 30% higher than condensing furnaces and is sustained into the same cold temperatures.

42 ENGINEERING↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Building Envelope Characteristics in Cold Climates

Prescriptive guidelines for thermal insulation in the design of buildings in cold climates have traditionally been derived by a holistic consideration of climatic factors, energy policy, environmental policy, and economics. The differences in thermal barrier requirements in buildings across the arctic and subarctic regions of the world are influenced as much by the differing priorities of the governing bodies that set these requirements as by actual physical demands and conditions. Usually, national requirements for building envelope characteristics such as thermal insulation values, building envelope airtightness, vapor permeability, building mass, and detailing are based on economics, durability, and environmental considerations. Consideration of thermal energy system resilience provides a new paradigm through which to view the optimization of these parameters. The paper describes specifics of construction in cold climates; summarizes best practice requirements for the building envelope characteristics for buildings located in cold and arctic climate of the United States, Canada, and Scandinavian countries; provides some details illustrating how to implement these requirements; and compares the effects of different levels of building envelope efficiency and building mass on indoor air temperature decay when heat supply is interrupted. The paper also presents results from experts' discussions during the consultation forum "Thermal Energy Systems Resilience in Cold/Arctic Climates" (ERDC 2020) and research conducted under the IEA EBC Annex 73, the Environmental Security Technology Certification Program (ESTCP) Project "Technologies Integration to Achieve Resilient, Low-Energy Military Installations," and U.S. Army Program project 633734T1500 under Military Engineering Technology Demonstration. The paper complements the Cold-Climate Design Guide (ASHRAE 2015) with a focus on the resilience of thermal energy systems.

Arctic↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study on a novel three-phase absorption thermal battery with high energy density applied to buildings

Buildings contribute to 75% of total electricity consumption and 80% of peak electricity demand in the United States. A significant portion of building electricity consumption goes to space conditioning. Therefore, using thermal energy storage (TES) to decouple the building electricity consumption and the fluctuating space-conditioning load has significant potential to shift peak electricity demand and improve the stability of the grid. To provide effective TES within the spatial constraints in buildings, a three-phase absorption thermal battery (TATB) system with very high energy storage density was designed and studied. The TATB stores low-temperature heat in hydrate crystals of salts and supports space conditioning through absorption systems. In this study, a benchtop TATB using lithium chloride (LiCl) hydrate crystals as the storage material was tested under practical operating conditions for its energy storage density and discharge rate. We report the TATB successfully generated LiCl hydrate crystals during charging mode and then dissolved the crystals during discharging mode. A material-based energy storage density of 300 kWh/m 3 (specific energy of 903 kJ/kg) was achieved with a discharge rate of up to 1.3 kW thermal energy. The test results verified the high performance of the TATB and encouraged further development of this technology.

25 ENERGY STORAGE↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗