Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration

The most accurate astronomical data is available from space-based observations that are not impeded by the Earth's atmosphere. Such measurements may require spectral samples taken as long as decades apart, with the 1 cm/s velocity precision integrated over a broad wavelength range. This raises the requirements specifically for instruments used in astrophysics research missions -- their stringent wavelength resolution and accuracy must be maintained over years and possibly decades. Therefore, a stable and broadband optical calibration technique compatible with spaceflights becomes essential. The space-based spectroscopic instruments need to be calibrated in situ, which puts forth specific requirements to the calibration sources, mainly concerned with their mass, power consumption, and reliability. A high-precision, high-resolution reference wavelength comb source for astronomical and astrophysics spectroscopic observations has been developed that is deployable in space. The optical comb will be used for wavelength calibrations of spectrographs and will enable Doppler measurements to better than 10 cm/s precision, one hundred times better than the current state-of-the- art.

Strekalov, Dmitry V.↗

Calibration of VIIRS F1 Sensor Fire Detection Band Using lunar Observations

Visible Infrared Imager Radiometer Suite (VIIRS) Fight 1 (Fl) sensor includes a fire detection band at roughly 4 microns. This spectral band has two gain states; fire detection occurs in the low gain state above approximately 345 K. The thermal bands normally utilize an on-board blackbody to provide on-orbit calibration. However, as the maximum temperature of this blackbody is 315 K, the low gain state of the 4 micron band cannot be calibrated in the same manner as the rest of the thermal bands. Regular observations of the moon provide an alternative calibration source. The lunar surface temperature has been recently mapped by the DIVINER sensor on the LRO platform. The periodic on-board high gain calibration along with the DIVINER surface temperatures was used to determine the emissivity and solar reflectance of the lunar surface at 4 microns; these factors and the lunar data are then used to fit the low gain calibration coefficients of the 4 micron band. Furthermore, the emissivity of the lunar surface is well known near 8.5 microns due to the Christiansen feature (an emissivity maximum associated with Si-O stretching vibrations) and the solar reflectance is negligible. Thus, the 8.5 micron band is used for relative calibration with the 4 micron band to de-trend any temporal variations. In addition, the remaining thermal bands are analyzed in a similar fashion, with both calculated emissivities and solar reflectances produced.

McIntire, Jeff↗

Evaluating the Calibration and Validation of the Clouds and the Earth’s Radiant Energy System (CERES) instruments on Terra and Aqua Over Twenty Years

Six Clouds and the Earth’s Radiant Energy System (CERES) instruments on four satellites are used to produce a global continuous multi-decadal record of Earth’s radiation budget (ERB) at the top-of-atmosphere (TOA). Each CERES instrument was calibrated and characterized on the ground before launch, while post-launch calibration is conducted using on-board calibration sources. The performance of the CERES instruments is verified using vicarious approaches involving both Earth and celestial targets. In this paper, we describe the calibration and validation approach and demonstrate the performance of the CERES instruments on the Terra and Aqua spacecrafts over the twenty-year period since launch. Validation results demonstrate that after applying the appropriate calibration corrections, all four instruments are stable and perform consistently with each other. Comparisons of observations between instruments on the two spacecrafts during orbital crossings further confirm the consistent performance across all instruments over the twenty year period.

Terra↗

ERBE - Assessment of measurement accuracy

The Earth Radiation Budget Experiment (ERBE) represents a continuing effort to estimate the solar incident and earth reflected and emitted radiance from spacecraft measurements. The development of accurate and stable sensors and calibration sources is mandatory but not sufficient to attain and validate required measurement accuracies. It is also necessary to develop and experimentally test computational models of the calibration and measurement processes to account for environmental differences between (static) calibrations and (dynamic) measurements of the earth radiant exitance that varies with wavelength, position, direction, and time.

Spiers, R. B., Jr.↗

Calibration of the EGRET high-energy gamma-ray telescope in the range 20-10,000 MeV with a tunable beam of quasi-monoenergetic gamma rays at SLAC

The EGRET telescope, one of the instruments to be carried on NASA's Gamma Ray Observatory, is designed to explore the high-energy portion (20-24,000 MeV) of the electromagnetic spectrum. A calibration source of gamma-rays over this wide energy range has been used together with an appropriate set of intensity-monitoring instruments, to conduct a calibration of the EGRET telescope over this energy range for the full telescope aperture. The calibration method and an overview of the results are described.

Thompson, D. J.↗

Spectral Irradiance Calibration in the Infrared: Calibrated Stellar Spectra Using Dirbe Radiometry - 9

The absolute calibration of the COBE/DIRBE data in the range 1-25 microns is examined through the in-band fluxes of DIRBE's own set of point-source calibration objects. Using the values of DIRBE fluxes expected for Sirius and for 10 of our published set of absolutely calibrated K and M giants that are in common with DIRBE's own calibration network, I find consistency with the project's formal basis, namely, our published calibrated spectrum of Sirius. This consistency means that one can use the DIRBE radiometry to construct absolutely calibrated "stellar templates" (i.e., continuous calibrated spectra from 1 to 35 microns) on the assumption that the intrinsic stellar spectrum of a star of given spectral class matches the intrinsic spectrum for the star of the same spectral class among the set of K and M giants, the spectrum of which has been absolutely defined. This technique is validated using a set of early M giants with well-characterized ground-based photometry and confirmed with IRAS low-resolution spectra.

Cohen, Martin↗

Lucy L’Ralph In-Flight Calibration and Results at (152830) Dinkinesh

The L'Ralph instrument is a key component of NASA's Lucy mission, intended to provide spectral image data of multiple Jupiter Trojans. The instrument operates from ∼0.35 to 4 μm using two focal plane assemblies: a 350–950 nm multispectral imager, Multi-spectral Visible Imaging Camera (MVIC), and a 0.97–4 μm imaging spectrometer, Linear Etalon Imaging Spectral Array (LEISA). Instrument calibration was established through ground testing before launch and has been monitored during cruise utilizing internal calibration sources and stellar targets. In-flight data have shown that the instrument thermal performance is exceeding expectations, allowing for early updates to LEISA radiometric and pointing calibrations. MVIC radiometric performance remains stable more than 3 yr since launch. The serendipitous identification of a new flyby target, (152830) Dinkinesh, allowed testing of instrument performance and interleaved LEISA and MVIC acquisitions on an asteroid target. Both MVIC and LEISA obtained data of Dinkinesh and its moon, Selam, demonstrating that they show good spectral agreement with an S- or Sq-type asteroid, along with evidence of a 3 μm absorption feature.

Amy A Simon↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

Improved S/N meter

Signal-to-noise ratios /S/N/ meter containing a variable-frequency notch filter measures noise plus interference in the presence of carrier or modulation signals. A noise source and calibration signal source are included in the instrument for calibration purposes.

Windett, C. B.↗

First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket

Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018, from the White Sands Missile Range, USA. This flight marks the first successful operation of a transition-edge sensor array and its time-division multiplexing readout system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The onboard calibration source provided X-rays in flight, and it is used to compare detector performance during preflight integration, flight, and after the successful post-flight recovery. This calibration data demonstrate the capabilities of the detector in a space environment as well as its potential for future flight.

TES↗

Solar Ultraviolet Spectral Irradiance Monitor (SUSIM)

The solar ultraviolet spectral irradiance monitor (SUSIM) measures the ultraviolet flux from the entire Sun with high absolute accuracy over the wavelength range 120 to 400 nm with a resolution of 0.1 nm. SUSIM consists of two identical double dispersion scanning spectrometers with 5 photodiodes, 2 photon counters, and a deuterium lamp calibration source, all sealed in a canister pressurized to 1.1 atmosphere of argon. One spectrometer is used almost continuously during sunlight, the other is used once per day as a calibration check. The observations will yield improved absolute measurements of the ultraviolet solar fluxes, provide an accurate reference for studies of variability of the solar fluxes on the time scales of the solar cycle and longer, and measure shorter term changes as well. These measurements complement the active cavity radiometer (ACR) measurements of the total solar irradiance. The data will be used to study the physical behavior of the Sun and the Earth's atmosphere, weather, and climate.

Moore, R. L.↗

Solar Ultraviolet Spectral Irradiance Monitor (SUSIM)

The solar ultraviolet spectral irradiance monitor (SUSIM) measures the ultraviolet flux from the entire Sun with high absolute accuracy over the wavelength range 120 to 400 nm with a resolution of 0.1 nm. SUSIM consists of two identical double dispersion scanning spectrometers with 5 photodiodes, 2 photon counters, and a deuterium lamp calibration source, all sealed in a canister pressurized to 1.1 atmosphere of argon. One spectrometer is used almost continuously during sunlight, the other is used once per day as a calibration check. The observations will yield improved absolute measurements of the ultraviolet solar fluxes, provide an accurate reference for studies of variability of the solar fluxes on the time scales of the solar cycle and longer, and measure shorter term changes as well. These measurements complement the ACR measurements of the total solar irradiance. The data will be used to study the physical behavior of the Sun and the Earth's atmosphere, weather, and climate.

Moore, R.↗

Error Analysis of Remotely-Acquired Mossbauer Spectra

On the Mars Exploration Rovers, Mossbauer spectroscopy has recently been called upon to assist in the task of mineral identification, a job for which it is rarely used in terrestrial studies. For example, Mossbauer data were used to support the presence of olivine in Martian soil at Gusev and jarosite in the outcrop at Meridiani. The strength (and uniqueness) of these interpretations lies in the assumption that peak positions can be determined with high degrees of both accuracy and precision. We summarize here what we believe to be the major sources of error associated with peak positions in remotely-acquired spectra, and speculate on their magnitudes. Our discussion here is largely qualitative because necessary background information on MER calibration sources, geometries, etc., have not yet been released to the PDS; we anticipate that a more quantitative discussion can be presented by March 2005.

Schaefer, Martha W.↗

A composite likelihood approach for inference under photometric redshift uncertainty

ABSTRACT Obtaining accurately calibrated redshift distributions of photometric samples is one of the great challenges in photometric surveys like LSST, Euclid, HSC, KiDS, and DES. We present an inference methodology that combines the redshift information from the galaxy photometry with constraints from two-point functions, utilizing cross-correlations with spatially overlapping spectroscopic samples, and illustrate the approach on CosmoDC2 simulations. Our likelihood framework is designed to integrate directly into a typical large-scale structure and weak lensing analysis based on two-point functions. We discuss efficient and accurate inference techniques that allow us to scale the method to the large samples of galaxies to be expected in LSST. We consider statistical challenges like the parametrization of redshift systematics, discuss and evaluate techniques to regularize the sample redshift distributions, and investigate techniques that can help to detect and calibrate sources of systematic error using posterior predictive checks. We evaluate and forecast photometric redshift performance using data from the CosmoDC2 simulations, within which we mimic a DESI-like spectroscopic calibration sample for cross-correlations. Using a combination of spatial cross-correlations and photometry, we show that we can provide calibration of the mean of the sample redshift distribution to an accuracy of at least 0.002(1 + z), consistent with the LSST-Y1 science requirements for weak lensing and large-scale structure probes.

(cosmology:) large-scale structure of Universe↗

Demonstration of neutron radiation-induced nucleation of supercooled water

In this study, we present direct evidence for neutrons causing nucleation of supercooled water. Highly purified water (20 nm filtration) is cooled to well below freezing (as low as −20 °C) with a radioactive calibration source of neutrons/gamma-rays either present or removed during each of many control cooling runs for the same volume of water. When it is primarily neutrons irradiating the sample bulk, the non-equilibrium freezing point (also known as the “supercooling point”) is, on average, +0.7 °C warmer than the control equivalent, with a statistical significance of greater than 5 Sigma, with systematic uncertainty included. This effect is not observed with water in the presence of gamma-rays instead of neutrons. While these neutrons should have theoretically had sufficient energy to mount the energy barrier, corroborating our results, their raising of supercooling temperature has never been reported experimentally to the best of our knowledge. The potential to use deeply supercooled solutions, not only water, as metastable detectors for radiation and perhaps dark matter or neutrino physics presents now a new avenue for exploration.

Szydagis, Matthew↗

VLA observations of a solar noise storm

The first Very Large Array (VLA) observations of the sun at 92 cm wavelength (328 MHz) are presented. A 3-hr solar noise storm was detected; it consisted of burst-like spikes superimposed on a slowly varying background, and both storm components were 95 + or - 5 percent right-hand circularly polarized. A long duration soft X ray event preceeded the radio radiation by 30 m, suggesting a disturbance moving outwards at a velocity of v = 78 km/s. The 92 cm noise storm was resolved with an angular resolution of 9 sec for time intervals as short as 13 s. During the onset and early phases, the storm consisted of four compact sources, each with an angular diameter of 40 sec, oriented within an elongated source with angular dimensions of 40 sec by 200 sec. During the subsequent hour the most intense emission was located in two 40 sec sources separated by 100 sec. Snapshot maps revealed a persistent elongated source ta successive Peaks, with a scatter in the source position. A systematic position shift of Delta Theta sub I greater than or = 15 sec can be produced by the earth's ionoshere, but these effects can be removed by frequent observations of a nearby calibrator source. The observations confirm previously reported trends for a decrease in source size at higher frequencies, but they suggest a hitherto unresolved complexity in source structure.

Lang, Kenneth R.↗

Measurements with the Chandra Flight Contamination Monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements, which place limits on the change in mirror-detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces.

Elsner, R. E.↗