Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Johnson, B. Carol↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Hooker, Stanford B.↗

Gravitational Wave Sources as Timing References for LISA Data

In the megahertz gravitational-wave band, galactic ultra-compact binaries (UCBs) are continuous sources emitting at near-constant frequency. The signals from many of these galactic binaries will be sufficiently strong to be detectable by the Laser Interferometer Space Antenna (LISA) after approximately Omicron (1 week) of observing. In addition to their astrophysical value, these UCBs can be used to monitor the data quality of the observatory. This paper demonstrates the capabilities of galactic UCBs to be used as calibration sources for LISA by demanding signal coherence between adjacent week-long data segments separated by a gap in time of a priori unknown duration. A parameter for the gap duration is added to the UCB waveform model and used in a Markov-chain Monte Carlo algorithm simultaneously fitting for the astrophysical source parameters. Results from measurements of several UCBs are combined to produce a joint posterior on the gap duration. The measurement accuracy's dependence on how much is known about the UCBs through prior observing, and seasonal variations due to the LISA orbital motion, is quantified. The duration of data gaps in a two-week segment of data can be constrained to within approximately 0.2 s using Omicron (10) UCBs after one month of observing. The timing accuracy from UCBs improves to approximately or less than o.1 s after 1 year of mission operations. These results are robust to within a factor of approximately 2 when taking into account seasonal variations.

Gravitation Wave Sources↗

On-orbit Performance Of The Suzaku/XRS

The Suzaku high-resolution X-Ray Spectrometer (XRS) is the first orbiting x-ray microcalorimeter. This instrument, which maintains the sensor at less than 0.1K and utilizes liquid He and solid Ne cryogens, is capable of providing very high, non-dispersive x-ray spectroscopy. The microcalorimeter approach enables increasing spectral resolving power toward increasing energy. This fundamental characteristic makes it the instrument of choice for a variety of spectral diagnostics that can be uniquely obtained from studies of Fe K-line features common in such objects as cluster of galaxies and active galaxies, to name only two important classes out of many. The array aspect allows for imaging spectroscopy of extended sources without spectral degradation. Unfortunately, a design flaw in the XRS dewar/spacecraft interface caused the premature loss of liquid helium and rendered the instrument miusable. Nonetheless, during the three weeks following the launch of Suzaku, the instrument performed extremely well and demonstrated that the basic microcalorimeter concept is sound for space applications. An energy resolution of 7 eV FWHM at 6keV was obtained in orbit as measured using internal calibration sources. We will describe the XRS design and operation, explain what happened, and then present some lessons learned for future space missions utilizing this powerful technology.

Kelley, Richard↗

Extended soft X-ray emission in Seyfert galaxies: ROSAT HRI observations of NGC 3516, NGC 4151, and Markarian 3

We have used the ROSAT High Resolution Imager (HRI) to examine the distribution of soft X-rays in three nearby Seyfert galaxies with approximately 4 to 5 arcsecs FWHM spatial resolution. A feature of our analysis is an attempt to remove errors in the aspect solution using a method developed by one of us (J.M.). NGC 4151 shows resolved X-ray emission that is spatially correlated with the optical extended narrow-line region (ENLR), confirming the results obtained with the Einstein HRI by Elvis, Briel, & Henry. NGC 3516 is elongated along a position angle of approximately 40 to 220 deg, similar to the direction of the Z-shaped narrow-line region. MRK 3 is very faint in our HRI image and is probably spatially unresolved. We detect the faint X-ray source approximately 2 arcmins west of the MRK 3 nucleus previously found by Turner, Urry, & Mushotzky. We also detected the BL Lac object BL 1207 + 39 approximately 5 arcmins north-northwest of NGC 4151. This object appears spatially unresolved, but some excess X-ray emission may be observed in the azimuthally averaged radial brightness profile of BL 1207 + 39 between radii of 10 arcsecs and 30 arcsecs when compared to a calibration source. A much deeper image is necessary to confirm this result.

Morse, Jon A.↗

Satellite Instrument Calibration for Measuring Global Climate Change. Report of a Workshop at the University of Maryland Inn and Conference Center, College Park, MD. , November 12-14, 2002

Measuring the small changes associated with long-term global climate change from space is a daunting task. To address these problems and recommend directions for improvements in satellite instrument calibration some 75 scientists, including researchers who develop and analyze long-term data sets from satellites, experts in the field of satellite instrument calibration, and physicists working on state of the art calibration sources and standards met November 12 - 14, 2002 and discussed the issues. The workshop defined the absolute accuracies and long-term stabilities of global climate data sets that are needed to detect expected trends, translated these data set accuracies and stabilities to required satellite instrument accuracies and stabilities, and evaluated the ability of current observing systems to meet these requirements. The workshop's recommendations include a set of basic axioms or overarching principles that must guide high quality climate observations in general, and a roadmap for improving satellite instrument characterization, calibration, inter-calibration, and associated activities to meet the challenge of measuring global climate change. It is also recommended that a follow-up workshop be conducted to discuss implementation of the roadmap developed at this workshop.

NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NI↗

Evaluation of VIIRS and MODIS Thermal Emissive Band Calibration Stability Using Ground Target

The S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, a polar orbiting Earth remote sensing instrument built using a strong MODIS background, employs a similarly designed on-board calibrating source - a V-grooved blackbody for the thermal emissive bands (TEB). The central wavelengths of most VIIRS TEBs are very close to those of MODIS with the exception of the 10.7 micron channel. To ensure the long term continuity of climate data records derived using VIIRS and MODIS TEB, it is necessary to assess any systematic differences between the two instruments, including scenes with temperatures significantly lower than blackbody operating temperatures at approximately 290 K. Previous work performed by the MODIS Characterization Support Team (MCST) at NASAGSFC used the frequent observations of the Dome Concordia site located in Antarctica to evaluate the calibration stability and consistency of Terra and Aqua MODIS over the mission lifetime. The near-surface temperature measurements from an automatic weather station (AWS) provide a direct reference useful for tracking the stability and determining the relative bias between the two MODIS instruments. In this study, the same technique is applied to the VIIRS TEB and the results are compared with those from the matched MODIS TEB. The results of this study show a small negative bias when comparing the matching VIIRS and Aqua MODIS TEB, implying a higher scene temperature retrieval for S-VIIRS at the cold end. Statistically no significant drift is observed for VIIRS TEB performance over the first 3.5 years of the mission.

Madhavan, Sriharsha↗

Optical Design for CETUS a Wide-Field 1.5-m Aperture UV Payload Being Studied for a NASA Probe Class Mission Study

As part of a study funded by NASA headquarters, we are developing a probe-class mission concept called the Cosmic Evolution through UV Spectroscopy (CETUS). CETUS includes a 1.5-m aperture diameter telescope with a large field of view (FOV). CETUS includes three scientific instruments: a far ultraviolet (FUV) and near ultraviolet (NUV) imaging camera (CAM); a NUV multiobject spectrograph (MOS); and a dual-channel point/slit spectrograph (PSS) in the Lyman ultraviolet (LUV), FUV, and NUV spectral regions. The large FOV three-mirror anastigmatic (TMA) optical telescope assembly (OTA) simultaneously feeds the three separate scientific instruments. That is, the instruments view separate portions of the TMA image plane, enabling parallel operation by the three instruments. The field viewed by the MOS, whose design is based on an Offner-type spectrographic configuration to provide wide FOV correction, is actively configured to select and isolate numerous field sources using a next-generation micro-shutter array. The two-channel CAM design is also based on an Offner-like configuration. The PSS performs high spectral resolution spectroscopy on unresolved objects over the NUV region with spectral resolving power, R ~ 40,000, in an echelle mode. The PSS also performs long-slit imaging spectroscopy at R ~ 20,000 in the LUV and FUV spectral regions with two aberration-corrected, blazed, holographic gratings used in a Rowland-like configuration. The optical system also includes two fine guidance sensors, and wavefront sensors that sample numerous locations over the full OTA FOV. In-flight wavelength calibration is performed by a wavelength calibration system, and flat-fielding is also performed, both using in-flight calibration sources. We describe the current optical design of CETUS and the major trade studies leading to the design.

space sensors↗

The Gaia Catalogue Second Data Release and Its Implications to Optical Observations of Man-Made Earth Orbiting Objects

The Gaia catalogue second data release and its implications to optical observations of man-made Earth orbiting objects. Abstract and not the Final Paper is attached. The Gaia spacecraft was launched in December 2013 by the European Space Agency to produce a three-dimensional, dynamic map of objects within the Milky Way. Gaia's first year of data was released in September 2016. Common sources from the first data release have been combined with the Tycho-2 catalogue to provide a 5 parameter astrometric solution for approximately 2 million stars. The second Gaia data release is scheduled to come out in April 2018 and is expected to provide astrometry and photometry for more than 1 billion stars, a subset of which with a the full 6 parameter astrometric solution (adding radial velocity) and positional accuracy better than 0.002 arcsec (2 mas). In addition to precise astrometry, a unique opportunity exists with the Gaia catalogue in its production of accurate, broadband photometry using the Gaia G filter. In the past, clear filters have been used by various groups to maximize likelihood of detection of dim man-made objects but these data were very difficult to calibrate. With the second release of the Gaia catalogue, a ground based system utilizing the G band filter will have access to 1.5 billion all-sky calibration sources down to an accuracy of 0.02 magnitudes or better. In this talk, we will discuss the advantages and practicalities of implementing the Gaia filters and catalogue into data pipelines designed for optical observations of man-made objects.

Frith, James M.↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Revisit: Approach and Performance

The soil moisture active passive (SMAP) microwave radiometer is a fully-polarimetric L -band radiometer flown on the SMAP satellite in a 6 AM /6 PM sun-synchronous orbit at 685-km altitude. After the SMAP L1B_TB data product version 4 was released in 2018, the radiometer has undergone further calibration and validation. The goal is to reduce the difference between antenna temperature of ascending and descending orbits during the eclipse, and to reduce the dips in the calibration drift over the cold sky (CS) during the eclipse seasons in 2017 and 2018. The postlaunch calibration algorithm has been revisited by retrieving all of the calibration parameters simultaneously with two different options for the hot calibration source (the global ocean, or the radiometer internal reference load). The performance of the two options are compared here. The option with the radiometer internal reference load has been chosen by the SMAP science team for data release version 5. In addition, a correction offset is applied to the input signal to account for offsets during the early-mission stages with the SMAP synthetic aperture radar transmitter operating alongside the radiometer.

calibration↗

Coastal Research Imaging Spectrometer

The Coastal Research Imaging Spectrometer (CRIS) is an airborne remote sensing system designed specifically for research on the physical, chemical, and biological characteristics of coastal waters. The CRIS includes a visible-light hyperspectral imaging subsystem for measuring the color of water, which contains information on the biota, sediment, and nutrient contents of the water. The CRIS also includes an infrared imaging subsystem, which provides information on the temperature of the water. The combination of measurements enables investigation of biological effects of both natural and artificial flows of water from land into the ocean, including diffuse and point-source flows that may contain biological and/or chemical pollutants. Temperature is an important element of such measurements because temperature contrasts can often be used to distinguish among flows from different sources: for example, a sewage outflow could manifest itself in spectral images as a local high-temperature anomaly. Both the visible and infrared subsystems scan in pushbroom mode: that is, an aircraft carrying the system moves along a ground track, the system is aimed downward, and image data are acquired in across-track linear arrays of pixels. Both subsystems operate at a frame rate of 30 Hz. The infrared and visible-light optics are adjusted so that both subsystems are aimed at the same moving swath, which has across-track angular width of 15 . Data from the infrared and visible imaging subsystems are stored in the same file along with aircraft- position data acquired by a Global Positioning System receiver. The combination of the three sets of data is used to construct infrared and hyperspectral maps of scanned areas (see figure). The visible subsystem is based on a grating spectrograph and a rapid-readout charge-coupled-device camera. Images of the swatch are acquired in 256 spectral bands at wavelengths from 400 to 800 nm. The infrared subsystem, which is sensitive in a single wavelength band of 8 to 10 m, is based on a focal-plane array of HgCdTe photodetectors that are cooled to an operating temperature of 77 K by use of a closed-Stirling-cycle mechanical cooler. The nonuniformities of the HgCdTe photodetector array are small enough that the raw pixel data from the infrared subsystem can be used to recognize temperature differences on the order of 1 C. By use of a built-in blackbody calibration source that can be switched into the field of view, one can obtain bias and gain offset terms for individual pixels, making it possible to offset the effects of nonuniformities sufficiently to enable the measurement of temperature differences as small as 0.1 C.

Lucey, Paul G.↗

Rotary shutter mechanism contains optical elements

Two cylindrical shutter mechanisms having fixed outer sleeves and rotating inner sleeves use single stepping motor and Geneva mechanism to sequentially move optical components into path of ultraviolet monochromator for output control to photomultiplier. Photometric and wavelength calibration sources insure shutter positions according to operational phases.

Weilbach, A. O.↗

Thermal scanner data for studying freeze conditions and for aiding irrigation scheduling

The use of thermal imagery in connection with plant water stress appears to hold considerable potential, particularly with scanners such as the RS-14 where internal calibration sources can be adjusted to bracket the temperatures of interest. The data from the thermal film are fairly easy to reduce; however, data reduction in 3 days or less would be required before it could be used in irrigation timing.

Bartholic, J. F.↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Earth resources sensing technology - 24-channel multispectral sensor system development.

Description of the technology applied to a 24-channel multispectral scanner developed as a tool to investigate the portion of the electromagnetic spectrum between 0.34 and 13.0 microns. Energy reflected or emitted from the terrain and system calibration sources is collected by the scan mirror, reflected into the collecting optics, and brought to focus in a plane containing a square aperture. A dichroic optical element splits the energy which passes through the aperture into two wavelength bands in which wavelengths are greater than and less than 2.0 microns, respectively. These two wavelength bands are dispersed spectrally by two grating spectrometers. The energy from 24 distinct spectral intervals is transformed into electrical signals by 24 detector/preamplifier combinations. These signals then become the inputs to a video processor in an airborne electronics console.

Kessel, J. E.↗