Search NASA⌕ Search

SEARCH · Search NASA

Results for “calorimeter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

CMS Full Simulation for Run 3

We report the status of the CMS full simulation for Run 3. During the long shutdown of the LHC a significant update has been introduced to the CMS code for simulation. The CMS geometry description is reviewed. Several important modifications were needed. CMS detector description software is migrated to the DD4Hep community developed tool. We will report on our experience obtained during the process of this migration. Geant4 10.7 is the CMS choice for Run 3 simulation productions. We will discuss arguments for this choice, the strategy of adaptation of a new Geant4 version, and will report on the physics performance of the CMS simulation. A special Geant4 Physics List configuration FTFP_BERT_EMM will be described, which provides a compromise between simulation accuracy and CPU performance. A significant fraction of time for simulation of CMS events is spent on tracking of charged particles in a magnetic field. In the CMS simulation a dynamic choice of Geant4 parameters for tracking in field is implemented. A new method is introduced into simulation of electromagnetic components of hadronic showers in the electromagnetic calorimeter of CMS. For low-energy electrons and positrons a parametrization of GFlash type is applied. Results of tests of this method will be discussed. In summary, we expect about 25% speedup of the CMS simulation production for Run 3 compared to the Run 2 simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast Simulation of Electromagnetic Showers in the ATLAS Calorimeter: Frozen Showers

One of the most time consuming process simulating pp interactions in the ATLAS detector at LHC is the simulation of electromagnetic showers in the calorimeter. In order to speed up the event simulation several parametrisation methods are available in ATLAS. In this paper we present a short description of a frozen shower technique, together with some recent benchmarks and comparison with full simulation. An expected high rate of proton-proton collisions in ATLAS detector at LHC requires large samples of simulated events (Monte Carlo) to study various physics processes. A detailed simulation of particle reactions ('full simulation') in the ATLAS detector is based on GEANT4 and is very accurate. However, due to complexity of the detector, high particle multiplicity and GEANT4 itself, the average CPU time spend to simulate typical QCD event in pp collision is 20 or more minutes for modern computers. During detector simulation the largest time is spend in the calorimeters (up to 70%) most of which is required for electromagnetic particles in the electromagnetic (EM) part of the calorimeters. This is the motivation for fast simulation approaches which reduce the simulation time without affecting the accuracy. Several of fast simulation methods available within the ATLAS simulation framework (standard Athena based simulation program) are discussed here with the focus on the novel frozen shower library (FS) technique. The results obtained with FS are presented here as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experiments on the Capillary Condensation/Evaporation Hysteresis of Pure Fluids and Binary Mixtures in Cylindrical Nanopores

Here, a new experimental method, i.e., isochoric cooling/heating cycle measurement using differential scanning calorimeter (DSC), is applied to investigate the hysteretic phenomenon of pure components and mixtures confined in two different types of cylindrical nanopores (SBA-15 and KIT-6). The capillary condensation/evaporation hysteresis end point (T he ) for a specific system is determined by performing a series of measurements with different densities by increasing initial temperature and pressure. We confirm that for a pure component, T he is lower when confined in smaller nanopores, whereas T he for CH 4 /CO 2 and CH 4 /C 2 H 6 mixtures at the specific composition investigated are higher than that of pure CO 2 and C 2 H 6 , respectively, when confined in the same nanopores. To the best of our knowledge, this is the first time that T he of fluid mixture is experimentally studied, which further demonstrates that binary mixtures behave similarly to pure fluids when confined in nanoporous media. At low temperatures where hysteresis is observed, the shape as well as the duration of the exothermic peak (due to capillary condensation) and endothermic peak (due to capillary evaporation) indicate that capillary condensation, rather than capillary evaporation, takes place at/near a thermodynamic equilibrium. Within the accuracy of the measurements, we find that the total heat of capillary condensation is identical to that of capillary evaporation for all systems examined, regardless of the presence of hysteresis. By comparing the heat per unit volume among different systems, we also find that the heat per unit volume of the phase transition of confined pure fluid is lower than that of bulk, which further demonstrates that the molar density of confined pure liquid is less than that of bulk pure liquid at saturation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calorimeter with Bayesian unfolding of spectra of high-flux broadband x rays

We report the development of a multipurpose differential x-ray calorimeter with a broad energy bandwidth. The absorber architecture is combined with a Bayesian unfolding algorithm to unfold high energy x-ray spectra generated in high-intensity laser–matter interactions. Particularly, we show how to extract absolute energy spectra and how our unfolding algorithm can reconstruct features not included in the initial guess. The performance of the calorimeter is evaluated via Monte Carlo generated data. The method accuracy to reconstruct electron temperatures from bremsstrahlung is shown to be 5% for electron temperatures from 1 to 50 MeV. We study bremsstrahlung generated in solid target interaction showing an electron temperature of 0.56 ± 0.04 MeV for a 700 μm Ti titanium target and 0.53 ± 0.03 MeV for a 50 μm target. We investigate bremsstrahlung from a target irradiated by laser-wakefield accelerated electrons showing an endpoint energy of 551 ± 5 MeV, inverse Compton generated x rays with a peak energy of 1.1 MeV, and calibrated radioactive sources. The total energy range covered by all these sources ranges from 10 keV to 551 MeV.

47 OTHER INSTRUMENTATION↗

High Power Flex-Propellant Arcjet Performance

A MW-class electrothermal arcjet based on a water-cooled, wall-stabilized, constricted arc discharge configuration was subjected to extensive performance testing using hydrogen and simulated ammonia propellants with the deliberate aim of advancing technology readiness level for potential space propulsion applications. The breadboard design incorporates alternating conductor/insulator wafers to form a discharge barrel enclosure with a 2.5-cm internal bore diameter and an overall length of approximately 1 meter. Swirling propellant flow is introduced into the barrel, and a DC arc discharge mode is established between a backplate tungsten cathode button and a downstream ringanode/ spin-coil assembly. The arc-heated propellant then enters a short mixing plenum and is accelerated through a converging-diverging graphite nozzle. This innovative design configuration differs substantially from conventional arcjet thrusters, in which the throat functions as constrictor and the expansion nozzle serves as the anode, and permits the attainment of an equilibrium sonic throat (EST) condition. During the test program, applied electrical input power was varied between 0.5-1 MW with hydrogen and simulated ammonia flow rates in the range of 4-12 g/s and 15-35 g/s, respectively. The ranges of investigated specific input energy therefore fell between 50-250 MJ/kg for hydrogen and 10-60 MJ/kg for ammonia. In both cases, observed arc efficiencies were between 40-60 percent as determined via a simple heat balance method based on electrical input power and coolant water calorimeter measurements. These experimental results were found to be in excellent agreement with theoretical chemical equilibrium predictions, thereby validating the EST assumption and enabling the utilization of standard TDK nozzle expansion analyses to reliably infer baseline thruster performance characteristics. Inferred specific impulse performance accounting for recombination kinetics during the expansion process implied nearly frozen flow in the nozzle and yielded performance ranges of 800-1100 sec for hydrogen and 400-600 sec for ammonia. Inferred thrust-to-power ratios were in the range of 30-10 lbf/MWe for hydrogen and 60-20 lbf/MWe for ammonia. Successful completion of this test series represents a fundamental milestone in the progression of high power arcjet technology, and it is hoped that the results may serve as a reliable touchstone for the future development of MW-class regeneratively-cooled flex-propellant plasma rockets.

Litchford, Ron J.↗

Closeout Report for the Refractory Metal Accelerated Heat Pipe Life Test Activity

With the selection of a gas-cooled reactor, this heat pipe accelerated life test activity was closed out and its resources redirected. The scope of this project was to establish the long-term aging effects on Mo-44.5%Re sodium heat pipes when subjected to space reactor temperature and mass fluences. To date, investigators have demonstrated heat pipe life tests of alkali metal systems up to .50,000 hours. Unfortunately, resources have not been available to examine the effect of temperature, mass fluence, or impurity level on corrosion or to conduct post-test forensic examination of heat pipes. The key objective of this effort was to establish a cost/time effective method to systematically test alkali metal heat pipes with both practical and theoretical benefits. During execution of the project, a heat pipe design was established, a majority of the laboratory test equipment systems specified, and operating and test procedures developed. Procurements for the heat pipe units and all major test components were underway at the time the stop work order was issued. An extremely important outcome was the successful fabrication of an annular wick from Mo-5%Re screen (the single, most difficult component to manufacture) using a hot isostatic pressing technique. This Technical Publication (TP) includes specifics regarding the heat pipe calorimeter water-cooling system, vendor design for the radio frequency heating system, possible alternative calorimeter designs, and progress on the vanadium equilibration technique. The methods provided in this TP and preceding project documentation would serve as a good starting point to rapidly implement an accelerated life test. Relevant test data can become available within months, not years, and destructive examination of the first life test heat pipe might begin within 6 months of test initiation. Final conclusions could be drawn in less than a quarter of the mission duration for a long-lived, fission-powered, deep space probe.

Martin, J.↗

X-ray film chamber with carbon target of Tien-Shan complex array

X-ray films were exposed inside the ionization calorimeter under 74g/sq cm of carbon and 5 cm of lead. The X-ray film chamber area is 35 sq. m. Moving X-ray films were used, 50% of the events, which succeeded to determine incidence time, were identified with corresponding extensive air showers (EAS). For such events the size spectrum of associated EAS was derived. Two methods of energy measurement using X-ray films and ionization calorimeter were compared. The energy transfer from selected hadron to electromagnetic component is illustrated. It is found that in cascades with high energy release into electromagnetic components the hadron component is practically absent.

Cherdyntseva, K. V.↗

Water-equivalent path length calibration of a prototype proton CT scanner

Purpose: The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. Methods: A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the calorimeter response for protons of 200 and 100 MeV initial energies undergoing degradation in polystyrene plates of known thickness and relative stopping power (RSP) with respect to water. Calibration curves for the two proton energies were obtained by fitting a second-degree polynomial to the water-equivalent path length versus calorimeter response data. Using the 100 MeV calibration curve, the RSP values for a variety of tissue-equivalent materials were measured and compared to values obtained from a standard depth-dose range shift measurement using a water-tank. A cylindrical water phantom was scanned with 200 MeV protons and its RSP distribution was reconstructed using the 200 MeV calibration. Results: It is shown that this calibration method produces measured RSP values of various tissue-equivalent materials that agree to within 0.5% of values obtained using an established water-tank method. The mean RSP value of the water phantom reconstruction was found to be 0.995 {+-} 0.006. Conclusions: The method presented provides a simple and reliable procedure for calibration of a pCT scanner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Dissipative Losses in AC-Biased Mo/Au Bilayer Transition-Edge Sensors

We are developing kilo-pixel arrays of transition-edge sensors (TESs) for the X-ray Integral Field Unit on ESA’s Athena observatory. Previous measurements of AC-biased Mo/Au TESs have highlighted a frequency-dependent loss mechanism that results in broader transitions and worse spectral performance compared to the same devices measured under DC bias. In order to better understand the nature of this loss, we are now studying TES pixels in different geometric configurations. We present measurements on devices of different sizes and with different metal features used for noise mitigation and X-ray absorption. Our results show how the loss mechanism is strongly dependent upon the amount of metal in close proximity to the sensor and can be attributed to induced eddy current coupling to these features. We present a finite element model that successfully reproduces the magnitude and geometry dependence of the losses. Using this model, we present mitigation strategies that should reduce the losses to an acceptable level.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Model on Heat Signal of Crystal Detector at Low Temperature

We present a model to calculate heat signal shapes from low-temperature bolometer attached to a crystal. This model is based on the elementary acoustic wave theory at low temperature and has been developed using modern Monte Carlo techniques. Physical processes in phonon propagation, such as transmission, scattering and reflection are considered. Using our model, the calculated time dependence of signal agrees with real experimental data. This model has applications in low-temperature rare event particle detectors for dark matter and neutrinos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Detection Based on Machine Learning for the CMS Electromagnetic Calorimeter Online Data Quality Monitoring

Using a semi-supervised machine learning approach we present a real-time anomaly detection system based on an autoencoder used for online data quality monitoring of the CMS electromagnetic calorimeter operating at the CERN LHC. We introduce a novel method that maximizes the anomaly detection performance making use of the time-dependence of anomalies and the spatial variations in the detector response. The autoencoder-based system efficiently detects anomalies in real time and maintains a very low false discovery rate. We validate the performance of this novel system with anomalies from LHC collision data taken in 2018 and 2022. In addition, results are presented after deploying the autoencoder-based system in the CMS online Data Quality Monitoring workflow at the beginning of LHC Run 3 resulting in the system to detect issues that were missed by the existing system.

Harilal, Abhirami [Carnegie Mellon University, Pit↗

New methodology for simultaneous volumetric and calorimetric measurements: Direct determination of {alpha}{sub p} and C{sub p} for liquids under pressure

A new batch cell has been developed to measure simultaneously both isobaric thermal expansion and isobaric heat capacity from calorimetric measurements. The isobaric thermal expansion is directly proportional to the linear displacement of an inner flexible below and the heat capacity is calculated from the calorimetric signal. The apparatus used was a commercial Setaram C-80 calorimeter and together with this type of vessels can be operated up to 20 MPa and in the temperature range of 303.15-523.15 K, In this work, calibration was carried out using 1-hexanol and subsequently both thermophysical properties were determined for 3-pentanol, 3-ethyl-3-pentanol, and 1-octanol at atmospheric pressure, 5 and 10 MPa, and from 303.15 to 423.15 K in temperature. Finally experimental values were compared with the literature in order to validate this new methodology, which allows a very accurate determination of isobaric thermal expansion and isobaric heat capacity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light collection and pulse-shape discrimination in elongated scintillator cells for the PROSPECT reactor antineutrino experiment

A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The magnitude and uniformity of light collection and neutron-gamma discrimination power in the energy range of antineutrino inverse beta decay products have been studied using gamma and spontaneous fission calibration sources deployed along the cell axis. We also study neutron-gamma discrimination and light collection abilities for differing PMT and reflector configurations. As a result, key design features for optimizing MeV-scale response and background rejection capabilities are identified.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The laser-based gain monitoring system of the calorimeters in the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

‘Flux+Mutability’: a conditional generative approach to one-class classification and anomaly detection

Abstract Anomaly Detection is becoming increasingly popular within the experimental physics community. At experiments such as the Large Hadron Collider, anomaly detection is growing in interest for finding new physics beyond the Standard Model. This paper details the implementation of a novel Machine Learning architecture, called Flux+Mutability, which combines cutting-edge conditional generative models with clustering algorithms. In the ‘flux’ stage we learn the distribution of a reference class. The ‘mutability’ stage at inference addresses if data significantly deviates from the reference class. We demonstrate the validity of our approach and its connection to multiple problems spanning from one-class classification to anomaly detection. In particular, we apply our method to the isolation of neutral showers in an electromagnetic calorimeter and show its performance in detecting anomalous dijets events from standard QCD background. This approach limits assumptions on the reference sample and remains agnostic to the complementary class of objects of a given problem. We describe the possibility of dynamically generating a reference population and defining selection criteria via quantile cuts. Remarkably this flexible architecture can be deployed for a wide range of problems, and applications like multi-class classification or data quality control are left for further exploration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy weighting for the upgrade of the CMS HCAL

In these simulation studies an energy weighting method is applied to the signals of the CMS hadronic calorimeter readout with a longitudinal segmentation for a possible future upgrade. Tabulated weighting factors are used to compensate for the different response of hadronic and electromagnetic energy depositions of simulated pion showers in the hadronic calorimeter. The weighting improves the relative energy resolution: ( Greek-Small-Letter-Sigma {sub E}/E){sup 2} = [((92.2 {+-} 0.6)%/{radical}E){sup 2} + ((6.5 {+-} 01)%{sup 2}] (before weighting), (( Greek-Small-Letter-Sigma {sub E,weight}/E){sup 2} = [((85.4 {+-} 0.5)%/{radical}E){sup 2} + ((4.4 {+-} 0.1)%{sup 2}] (after weighting), where E in the square root has units of GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Machine Learning landscape of top taggers

Based on the established task of identifying boosted, hadronically decaying top quarks, we compare a wide range of modern machine learning approaches. Unlike most established methods they rely on low-level input, for instance calorimeter output. While their network architectures are vastly different, their performance is comparatively similar. In general, we find that these new approaches are extremely powerful and great fun.

97 MATHEMATICS AND COMPUTING↗

Evaluation and certification of heater assemblies developed for thermal vacuum acceptance testing

Preparation of Rockwell International's Thermal Vacuum Chamber for acceptance testing of a mass produced satellite required the development of unique quartz lamp and hot wire heater assemblies. Testing performed on the basic elements of these heaters is described, as is the final testing done to certify that the heater assemblies meet the thermal requirements for acceptance testing. The methods and procedures of thermal mapping used during the development and final certification of these heater assemblies are presented. The absence of a definitive standard for determining flux distribution and heating boundaries for heaters of this type required the development of a test plan incorporating several thermal mapping techniques. These techniques include the development of heat flux using a multiple calorimeter array for both vacuum and ambient test conditions, and a photographic method for detecting heating boundaries. The test plan and thermal mapping techniques are discussed.

Allen, J. E.↗