Search NASA⌕ Search

SEARCH · Search NASA

Results for “calorimeter simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Laboratory Measurements of X-ray Emission from Highly Charged Argon Ions

Uncertainties in atomic models will introduce noticeable additional systematics in calculating the flux of weak dielectronic recombination (DR) satellite lines, affecting the detection and flux measurements of other weak spectral lines. One important example is the Ar xvii Heβ DR, which is expected to be present in emission from the hot intracluster medium of galaxy clusters and could impact measurements of the flux of the 3.5 keV line that has been suggested as a secondary emission from a dark matter interaction. We perform a set of experiments using the Lawrence Livermore National Laboratory's electron beam ion trap (EBIT-I) and the X-ray Spectrometer quantum calorimeter (XRS/EBIT) to test the Ar xvii Heβ DR origin of the 3.5 keV line. We measured the X-ray emission following resonant DR onto helium-like and lithium-like Argon using EBIT-I's Maxwellian simulator mode at a simulated electron temperature of T(e) = 1.74 keV. The measured flux of the Ar xvii Heβ DR lined is too weak to account for the flux in the 3.5 keV line, assuming reasonable plasma parameters. We, therefore, rule out Ar xvii Heβ DR as a significant contributor to the 3.5 keV line. A comprehensive comparison between the atomic theory and the EBIT experiment results is also provided.

Esra Bulbul↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Signal Extraction and Simulations for n -> p^0 y y and n -> p+p-e+e- Decays at the Jefferson Lab Eta Factory

The Jefferson Lab eta Factory (JEF) began acquiring data in early 2025. The experiment aims to give insight into the connection between Dark Matter physics models and the Standard Model by investigating rare decay processes of n and n' mesons. Several other physics motivations are also a key factor in the experiment, such as probing C and/or P violation and aspects of chiral perturbation theory. For these purposes, the forward calorimeter of the GlueX experiment in Jefferson Lab was upgraded so that it provides greater positional and energy resolution. Understanding physics-motivated cuts and background removal methods is of great importance to achieving JEF goals. Several methods have been implemented to obtain invariant mass plots for the “golden” channel of interest ¿ ¿ p0¿¿, while channels such as ¿ ¿ p+p-e+e- open a promising window into CP-violating physics. This thesis work shows a sig nificant background reduction in rare decay channels of interest, asymmetry factors comparable to recent experimental measurements, an evaluation on which analysis cuts to use after data acquisition and the likelihood of probing specific rare ¿ decays. Despite background rejection from obstructing decay channels, much remains to do to extract the p0¿¿ final-state. The asymmetry between the pion and lepton planes looks promising for p+p-e+e-; simulations show that the asymmetry is consistent with zero (no instrumental asymmetry), and the next step should include generators that model the physics of the asymmetry. This thesis work may help in the effort of probing CP-violating physics or solving the mysteries between “beyond-Standard Model” and our current understanding of physics.

Oresic, Stjepan [Univ. of Regina, SK (Canada)]↗

A Geant Study of the Scintillating Optical Fiber (SOFCAL) Cosmic Ray Detector

Recent energy measurements by balloon-borne passive emulsion chambers indicate that the flux ratios of protons to helium nuclei and of protons to all heavy nuclei decrease as the primary cosmic ray energy per nucleon increases above approx. 200 GeV/n, and suggest a "break" in the proton spectrum between 200 GeV and 5 TeV. However, these passive emulsion chambers are limited to a lower energy threshold of approx. 5 TeV/n, and cannot fully explore this energy regime. Because cosmic ray flux and composition details may be significant to acceleration models, a hybrid detector system called the Scintillating Optical Fiber Calorimeter (SOFCAL) has been designed and flown. SOFCAL incorporates both conventional passive emulsion chambers and an active calorimeter utilizing scintillating plastic fibers as detectors. These complementary types of detectors allow the balloon-borne SOFCAL experiment to measure the proton and helium spectra from approx. 400 GeV/n to approx. 20 TeV. The fundamental purpose of this study is to use the GEANT simulation package to model the hadronic and electromagnetic shower evolution of cosmic rays incident on the SOFCAL detector. This allows the interpretation of SOFCAL data in terms of charges and primary energies of cosmic rays, thus allowing the determinations of cosmic ray flux and composition as functions of primary energy.

Munroe, Ray B., Jr.↗

An Earth-Based Equivalent Low Stretch Apparatus to Assess Material Flammability for Microgravity & Extraterrestrial Fire-Safety Applications

One of the performance goals for NASA's enterprise of Human Exploration and Development of Space (HEDS) is to develop methods, data bases, and validating tests for material flammability characterization, hazard reduction, and fire detection/suppression strategies for spacecraft and extraterrestrial habitats. This work addresses these needs by applying the fundamental knowledge gained from low stretch experiments to the development of a normal gravity low stretch material flammability test method. The concept of the apparatus being developed uses the low stretch geometry to simulate the conditions of the extraterrestrial environment through proper scaling of the sample dimensions to reduce the buoyant stretch in normal gravity. The apparatus uses controlled forced-air flow to augment the low stretch to levels which simulate Lunar or Martian gravity levels. In addition, the effect of imposed radiant heat flux on material flammability can be studied with the cone heater. After breadboard testing, the apparatus will be integrated into NASA's White Sands Test Facility's Atmosphere-Controlled Cone Calorimeter for evaluation as a new materials screening test method.

Olson, S. L.↗

Beam Dynamics of the Muon $g\textrm{-}2$ Experiment

The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab aims to measure the muon anomalous magnetic moment $a_{\mu}$ with unprecedented precision, potentially uncovering physics beyond the Standard Model of particle physics. The result based on Runs 1-3, released in 2023, achieved a precision of 0.20 ppm. The experiment circulates muons in a storage ring, measuring $a_{\mu}$ from decay positron time and energy measurements collected with calorimeters. To achieve the required accuracy, it is crucial to measure and control the magnetic field in the ring with high precision. Beam dynamics corrections are necessary for muons not orbiting exactly in the midplane, for their oscillations, and for electric field effects. Highly accurate beam dynamics simulations are instrumental for quantifying and validating the beam dynamics corrections, ultimately improving the precision of the $a_{\mu}$ measurement and facilitating the achievement of the ambitious $70\:\mathrm{ppb}$ systematic uncertainty goal. The measured field data was incorporated into models for simulations using three codes: \texttt{gm2ringsim} (an internal Geant4-based code), \textit{COSY INFINITY}, and \textit{BMAD}. The advantages of \texttt{gm2ringsim} include using CAD-based geometry and modelling the detector effects. \textit{COSY INFINITY} is a highly accurate and efficient code that uses high-order differential-algebraic transfer maps, precise fringe field calculations, and advanced symplectification methods. Symplectification is important for maintaining the physical correctness of the muon beam behaviour with high precision over the storage time, ensuring conservation of phase space volume and preventing artificial damping or excitation of particle motion. The experiment completed its final Run 6 in July 2023, collecting 21 times more data than the previous BNL experiment. Analyses of data from Runs 4-6 are ongoing, with results planned for release in 2025, potentially resolving the current tension between experiment and theory.

43 PARTICLE ACCELERATORS↗

Analysis of SOFCAL calibration data

Ionization calorimeters determine the total energy of a particle by absorbing, within the mass of the calorimeter, the entire energy of the particle or a significant (and determinable) fraction of it. The JACEE group has used passive ionization calorimetery, which employs photographic emulsions as the detector medium, to measure the charge composition and energy spectrum of cosmic rays up to, and exceeding, 10(exp 14)eV. The SOFIC approach depends similarly on the use of three-dimensional nuclear-electromagnetic shower theory to relate the ionization deposits obtained during a shower to the energy of the particle causing the shower. Bundles of thousands of scintillating optical fibers are read out using image-intensified CCD's. Such an event may be triggered by a fast shower detector placed under the instrument or if only heavy particles are of interest, from a fast primary Cerention detector placed above the calorimeter. In the first study, fast Hammatsu photomultiplier tubes were purchased and tested for possible application for a triggering purpose. In the second study, some refinements have been made to the theoretical treatment of hadronic interactions in the central collision region. These will be helpful in improving the simulations necessary for observations of high energy cosmic ray nuclei with a SOFIC.

Gregory, John C.↗

NASA Tech Briefs, July 2011

Topics covered include: 1) Collaborative Clustering for Sensor Networks; 2) Teleoperated Marsupial Mobile Sensor Platform Pair for Telepresence Insertion Into Challenging Structures; 3) Automated Verification of Spatial Resolution in Remotely Sensed Imagery; 4) Electrical Connector Mechanical Seating Sensor; 5) In Situ Aerosol Detector; 6) Multi-Parameter Aerosol Scattering Sensor; 7) MOSFET Switching Circuit Protects Shape Memory Alloy Actuators; 8) Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition; 9) Circuit for Communication Over Power Lines; 10) High-Efficiency Ka-Band Waveguide Two-Way Asymmetric Power Combiner; 11) 10-100 Gbps Offload NIC for WAN, NLR, and Grid Computing; 12) Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices; 13) Flight Planning in the Cloud; 14) MPS Editor; 15) Object-Oriented Multi Disciplinary Design, Analysis, and Optimization Tool; 16) Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes; 17) Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy; 18) Planar Rotary Piezoelectric Motor Using Ultrasonic Horns; 19) Self-Rupturing Hermetic Valve; 20) Explosive Bolt Dual-Initiated from One Side; 21) Dampers for Stationary Labyrinth Seals; 22) Two-Arm Flexible Thermal Strap; 23) Carbon Dioxide Removal via Passive Thermal Approaches; 24) Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring; 25) Pressure Shell Approach to Integrated Environmental Protection; 26) Image Quality Indicator for Infrared Inspections; 27) Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging; 28) Scatterometer-Calibrated Stability Verification Method; 29) Test Port for Fiber-Optic-Coupled Laser Altimeter; 30) Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects; 31) Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror; 32) Generic, Extensible, Configurable Push-Pull Framework for Large-Scale Science Missions; 33) Dynamic Loads Generation for Multi-Point Vibration Excitation Problems; 34) Optimal Control via Self-Generated Stochasticity; 35) Space-Time Localization of Plasma Turbulence Using Multiple Spacecraft Radio Links; 36) Surface Contact Model for Comets and Asteroids; 37) Dust Mitigation Vehicle; 38) Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component; 39) SpaceCube Demonstration Platform; 40) Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers; 41) Spaceflight Ka-Band High-Rate Radiation-Hard Modulator; 42) Enabling Disabled Persons to Gain Access to Digital Media; 43) Cytometer on a Chip; 44) Principles, Techniques, and Applications of Tissue Microfluidics; and 45) Two-Stage Winch for Kites and Tethered Balloons or Blimps.

Source record↗

Accelerator Test of an Imaging Calorimeter

The Imaging Calorimeter for ACCESS (ICA) utilizes a thin sampling calorimeter concept for direct measurements of high-energy cosmic rays. The ICA design uses arrays of small scintillating fibers to measure the energy and trajectory of the produced cascades. A test instrument has been developed to study the performance of this concept at accelerator energies and for comparison with simulations. Two test exposures have been completed using a CERN test beam. Some results from the accelerator tests are presented.

Christl, Mark J.↗

Searching for Neutrino Tridents in the NOvA Near Detector

This dissertation presents a search for neutrino trident production in the NOvA near detector through the coherent ``dimuon" channel: $\nu_\mu +\hspace{1pt}\text{X} \rightarrow \nu_\mu + \mu^- + \mu^+ +\hspace{1pt}\text{X}$. Trident production is a rare, purely electroweak process with sensitivity to physics beyond the Standard Model. The theoretical background, motivation for studying the process, and previous experimental measurements are reviewed. The analysis uses data collected by the NOvA near detector (ND) from Fermilab's Neutrinos at the Main Injector (NuMI) beam between November 2014 and February 2024, corresponding to an exposure of $25.5\times 10^{20}$ protons on target. The ND is a segmented tracking calorimeter located 800~m from the beam target, receiving neutrinos with a mean energy of 2~GeV. A multi-pass background reduction strategy is implemented, including the development of a novel dimuon-specific tracking technique. Trident candidates are identified using a boost ed decision tree classifier trained on simulated signal and background events. Limited background Monte Carlo statistics necessitate the use of functional fits to sideband data, which are extrapolated to estimate backgrounds in the signal region. The unblinded data contain 9 trident-like events, with an estimated background of 5.66 $\pm$ 5.15 events. This yields a best fit estimate of 3.34 tridents compared to the Standard Model prediction of 4.66. A profiled Feldman-Cousins method is used to determine a 90\% confidence interval of [0,9.1] on the number of signal events, corresponding to an upper limit of 1.95$\times$ the Standard Model prediction. This result represents the lowest energy search for trident events to date, and the first experimental contribution to the process in 27 years.

Bowles, Reed Scott [Indiana U.]↗

Cosmic ray studies with a gas Cerenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cerenkov counter (threshold 16.5 GeV/nuc) and an ionization spectrometer are presented. The gas Cerenkov counter provides an absolute energy calibration for the response of the calorimeter for the Z range of 5-26 nuclei of cosmic rays. The contribution of scintillation to the gas Cerenkov pulse height has been obtained by independently selecting particles below the gas Cerenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi-squared between a Monte Carlo simulated data and flight data. Best fit power laws were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E exp-2.7, are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer.

Balasubrahmanyan, V. K.↗

Expanding the Measurement Capabilities of the mARC II Arc-Jet to Map the Operating Envelope for High-Enthalpy Air Flows

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center developed to produce high-enthalpy flows for low-cost technology development purposes. In this work, we introduce new measurement capabilities following the latest facility upgrades and begin characterizing the operating envelope for the two-disk arc-heater configuration with air as the working gas. The lower bound of the envelope corresponds to the lowest set current and the farthest sensor distance from the nozzle (𝐼set = 40 A, 𝑧 = 69 mm), while the upper bound corresponds to the highest current and closest sensor distance (𝐼set = 200 A, 𝑧 = 2 mm). Stagnation point heat flux was measured using a water-cooled Gardon gauge (⌀4.76 mm, 3/16" hemispherical), with values ranging from 15 ≤ q̇₀ ≤ 900 W/cm 2 . Stagnation pressure was measured using a water-cooled Pitot probe (⌀4.76 mm, 3/16" hemispherical), with values ranging from 18 ≤ p₀ ≤ 1100 Pa. The upgraded vacuum system is demonstrated to significantly extend the lower end of the operating envelope of the mARC II. Additionally, measurements of bulk enthalpy (3 ≤ h ≤ 13 MJ/kg) and stagnation enthalpy (4 ≤ h₀ ≤ 34 MJ/kg) demonstrate the mARC II facility's high-enthalpy capabilities. Completion of the operating envelope characterization is ongoing in tandem with the development of complementary diagnostic capabilities and numerical simulations.

instrumentation↗

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Mu2e experiment

The Mu2e experiment at Fermilab searches for the coherent, neutrino-less conversion of a μ − to e − in the Coulomb field of Al nuclei, that represents one of the cleanest Charged Lepton Flavor Violating (CLFV) processes for exploring Beyond the Standard Model (BSM) physics. Mu2e aims to improve previous sensitivity by four orders of magnitude, with a distinctive signature provided by identifying mono-energetic electrons with energy slightly below the muon rest mass. To reach this goal, the experiment will use the highest intensity pulsed muon beam in the world, with up to 6 × 1 0 9 stopped muons/sec. This is achieved using the Fermilab proton beam and the design and realization of a unique 25 m long superconducting solenoidal system. The high beam intensity relies upon minimizing beam losses in the slow extraction region, indicating an opportunity of using bent crystals for shadowing. A high-resolution straw tracker and a fast CsI crystal calorimeter identify the conversion electron. Both detectors are inserted behind the Stopping Target in the last solenoid section. A Cosmic Ray Veto covers a large part of the solenoids to suppress background produced by cosmic rays. In this paper, we report the details of the experimental layout, the construction status of the magnetic system and detectors, and a short description of the simulation and realization of the bent crystals. Performing crystal channeling in front of the first slow extraction septa will allow beam shadowing and largely reduce beam losses. •Charge Lepton Flavor Violation processes: μ − → e − conversion.•Large Superconducting Solenoid system.•High-Intensity beams•High precision detectors.•Crystal channeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and Computational Studies of Crystal Nucleation in Composition Gradients (Final Report)

The major goals of this project were to develop and validate a predictive nucleation model that incorporates composition gradients and is applicable to a large range of metallic systems which form both stochiometric and non-stochiometric compounds. Computationally we planned to expand the extent of thermodynamics-based theories and lay the groundwork to improve the general understanding and predictive capabilities of the role that gradients play in phase formation, glass formability and stability, and nucleation and growth events. To address these goals, we used Molecular Dynamics (MD) simulations and both isothermal and isochronal nanocalorimetric experiments on amorphous phases with a controlled composition gradient with the hopes of validating and improving the classical nucleation model and its use in solid solutions. While the computations were successful and identified ways to improve the classical nucleation model, the in situ nanocalorimetry studies proved very challenging due to unexpected difficulties in fabricating effective calorimeters and samples. Thus, we could not experimentally validate our predicted influence of composition gradients on nucleation. Nonetheless, important insights were gained and modifications to the classical nucleation theory were suggested.

36 MATERIALS SCIENCE↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Characterizing water/rock interaction in simulated comet nuclei via calorimetry: Tool for in-situ science, laboratory analysis, and sample preservation

Although results from the Giotto and Vega spacecraft flybys of comet P/Halley indicate a complex chemistry for both the ices and dust in the nucleus, carbonaceous chondrite meteorites are still regarded as useful analogs for the rocky components. Carbonaceous chondrites mixed with water enable simulation of water/rock interactions which may occur in cometary nuclei. Three general types of interactions can be expected between water and minerals at sub-freezing temperatures: heterogeneous nucleation of ice by insoluble minerals; adsorption of water vapor by hygroscopic phases; and freezing and melting point depression of liquid water sustained by soluble minerals. Two series of experiments were performed in a differential scanning calorimeter (DSC) with homogenized powders of the following whole-rock meteorites and comparison samples: Allende (CV3), Murchison (CM2), Orgueil (CI), Holbrook (L6), and Pasamonte (eucrite) meteorites as well as on peridotite (PCC-1, USGS), saponite (Sap-Ca-1, CMS), montmorillonite (STx-1, CMS), and serpentine (Franciscan Formation, California). Results are briefly discussed.

Allton, Judith H.↗