Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ordovician-Cambrian Units: Hierarchical Evaluation of Geologic Carbon Storage Resource Estimates

The Indiana Geological and Water Survey (IGWS) led subtask 1.1 to assess the regional distribution and estimate the storage capacity of Ordovician-Cambrian stratigraphic units located within the partnership region. A comprehensive data set of wireline logs and petrophysical information was used to generate these interpretations. These data include core analysis for porosity and permeability, mercury injection capillary pressure (MICP), and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for three potential storage reservoirs(limestone and dolostone from the Upper Ordovician Trenton Limestone/Black River Group and equivalent units, the Middle Ordovician St. Peter Sandstone, and primary target reservoir rocks of the Lower Ordovician and Upper Cambrian Knox Supergroup and equivalent units) calculated using six methodologies: (1) a fixed value of porosity of 10 percent in all units evaluated; (2) a unique average porosity (per well) from wireline-derived porosity (neutron, sonic, and/or density porosity for each unit); (3) porosity values from core analysis; (4) a depth-dependent porosity model (Knox Supergroup only); (5) porosity based on a model based on petrophysical facies; and (6) SREs using National Energy Technology Laboratory’s CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN beta V2). All methods used the same values for thickness for each unit. However, the areal extent of each assessment was limited by the data available for each method. Estimated volumes were calculated in 1-by-1 kilometer grid cells and summarized as county and total stratigraphic unit volumes. The resultant SREs mass are displayed using boxplots, which allow for comparing data statistics (mean values and variability) between methods. Differences observed in SRE results from the six methods are mainly attributable to differences in the data and conceptual models used to interpret or estimate porosity in each method. Based on this systematic variability between methods, it is inferred that methods 1, 4, and 6 are best used for regional-scale reconnaissance estimates of storage capacity while methods 2, 3, and 5 are more appropriate for local scales where more data is required. All estimates are data-density dependent and different methods require different amounts of data for reasonable assessments. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Water separation device for engine exhaust gas

A system includes an engine and an exhaust conduit in communication with the engine. A water separation device has exhaust gas passageways in communication with the exhaust conduit. The water separation device has a substrate and a membrane on the substrate. The substrate has inner walls surrounding the exhaust gas passageways with at least one of the inner walls being common to at least two of the exhaust gas passageways. The membrane is between the exhaust gas passageways and the substrate and has capillary condensation pores extending from the exhaust gas passageways to the substrate.

33 ADVANCED PROPULSION SYSTEMS↗

Non-dimensional performance and safety parameters for heat pipes

The use of heat pipes in safety-critical systems such as nuclear microreactors dictates the development of generalized, practical, scalable performance and safety parameters. Traditional dimensional metrics, while informative, lack the universality required for comparative analysis across varying designs and operating regimes. Here, this work introduces a comprehensive set of non-dimensional parameters to characterize heat pipe performance and safety, including capillary performance, effective thermal conductivity, response time, exergetic efficiency, allowable temperature gradients, allowable rate of temperature change, priming coefficients, and factor of safety. A reference heat pipe design representative of microreactor applications was analyzed via the developed parameters using both traditional analytical models and Sockeye simulations under transient and steady-state conditions. Sodium, potassium, and water were evaluated as working fluids to demonstrate the applicability of the framework across a broad temperature range. The proposed non-dimensional parameters effectively captured key thermal-hydraulic behaviors and safety concerns, as was demonstrated via Sockeye simulations. This framework supports the development of design optimization strategies, operational protocols, and safety assurance practices for advanced reactor systems and other high-reliability applications.

42 - ENGINEERING↗

Extending the capillary wave model to include the effect of bending rigidity: X-ray reflectivity and diffuse scattering

The surface roughness of a thin film at a liquid interface exhibits contributions of thermally excited fluctuations. This thermal roughness depends on temperature (𝑇), surface tension (𝛾), and elastic material properties, specifically the bending modulus (𝜅) of the film. A nonzero 𝜅 suppresses the thermal roughness at small length scales compared to an interface with zero 𝜅, as expressed by the power spectral density of the thermal roughness. The description of the x-ray scattering of the standard capillary wave model (CWM), which is valid for zero 𝜅, is extended to include the effect of 𝜅. The extended CWM (eCWM) provides a single analytical form for both the specular x-ray reflectivity (XRR) and the diffuse scattering around the specular reflection, and recovers the expression of the CWM at its zero 𝜅 limit. This theoretical approach enables the use of single-shot grazing incidence x-ray off-specular scattering (GIXOS) measurements for characterizing the structure of thin films on a liquid surface. The eCWM analysis approach decouples the thermal roughness factor from the surface scattering signal, providing direct access to the intrinsic surface-normal structure of the film and its bending modulus. Moreover, the eCWM facilitates the calculation of reflectivity at any desired resolution (pseudo-XRR approach). The transformation into pseudo-XRR provides the benefit of using widely available XRR software to perform GIXOS analysis. The extended range of the vertical scattering vector (𝑄 𝑧 ) available with the GIXOS pseudo-XRR approach allows for a higher spatial resolution than with conventional XRR. Experimental results are presented for various lipid systems, showing strong agreement between conventional specular XRR and pseudo-XRR methods. This agreement validates the proposed approach and highlights its utility for analyzing soft, thin films.

36 MATERIALS SCIENCE↗

Porous mesh manifold for enhanced boiling performance

High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the Feasibility of Measuring and Analyzing Strain Caused by Changes in Barometric Pressure in the Vadose Zone

Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.

54 ENVIRONMENTAL SCIENCES↗

CO 2 -Soluble Nonionic Surfactants for Enhanced CO 2 Storage via In Situ Foam Generation

Geologic carbon storage (GCS) is a rapidly evolving technology with the potential to reduce the environmental impact of fos-sil fuels. Saline aquifers, which comprise a sandstone matrix with brine in the pores, make up much of the pore space availa-ble for CO 2 storage in the United States. When CO 2 is injected in saline aquifers, however, capillary fingering occurs and only a small percentage of the pore space is filled with CO 2 . This is due to the low viscosity of CO 2 , which is roughly ten times less viscous than brine. To address this problem, we tested the ability of inexpensive, commercially available nonionic surfactants to be dissolved in the injected CO 2 and increase the apparent viscosity of CO 2 by generating CO 2 -in-water foams in situ.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing the Fabrication of Electrospun Nanofibrous Membrane Using Fractional Factorial Design

Electrospinning, a simple and easily tunable technique that utilizes the force balance between the electrostatic force and the solution surface tension to fabricate membranes out of 1D nanostructured fibers, has garnered much interest especially from the nanotechnology community. Depending on the morphology of the fibers, electrospun membrane has found its way in a wide range of applications, such as oil-water separation, desalination, tissue engineering, and batteries. During an electrospinning process, many factors can affect the morphology of the products, such as viscosity of the solution, voltage supply, discharge distance, feed rate of the solution, and electrospinning time. In this work, we investigated the impacts of the most important parameters on the morphology of electrospun fibrous membrane based on the fractional factorial design. We evaluated the electrospun fibrous membrane morphology using scanning electron microscopy (SEM) and capillary flow porometry. Poly (vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) was chosen for the current study due to its interesting and versatile functionalities including superior hydrophobicity, high free volume, and piezoelectricity. This work provides valuable insight for the fabrication of electrospun membranes, especially for tailoring membrane properties in accordance with any targeted applications.

Zhao, Yajing↗

A new capability for investigating the structure and dynamics of liquids at high pressures

Water and aqueous solutions are critical to many areas of science and technology. As a result, tremendous effort has been devoted to understanding them in detail. Despite over a century of research, fundamental questions about water and aqueous solutions remain unanswered. However, an intriguing possibility – that liquid water can exist in two thermodynamically distinct states – has emerged as the most likely explanation. The problem is that experimental confirmation of this hypothesis requires experiments on water at high pressures and low temperatures, conditions in which liquid water only exists briefly before turning into crystalline ice. This project investigated the feasibility of developing a new capability for study water and aqueous solutions under these challenging conditions. The physical constraints, such as the timescales for crystallization and thermal diffusion in supercooled water, were evaluated along with their impact on the design criteria for the instrument. Several basic design options were considered that could meet the technical requirements. The options were also evaluated with respect to their use of commercially available equipment versus the need for custom designs or in-house development. The project identified two viable options to pursue. The first option would use a high-pressure syringe pump in conjunction with fused silica (or sapphire) capillaries. The second option would use a diamond anvil cell. These options can both be used with optical spectroscopies, such as Raman or Infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Relative Permeability Model for Gas and Water Flow in Hydrate-Bearing Sediments With Laboratory and Field-Scale Application

In a producing gas hydrate reservoir the effective porosity available for fluid flow constantly changes with dissociation of gas hydrate. Therefore, accurate prediction of relative permeability using legacy models (e.g. Brooks-Corey (B-C), van Genuchten, etc.) that were developed for conventional oil and gas reservoirs would require empirical parameters to be calibrated at various S h over its range of variation, but such calibrations are precluded because of lack of experimental relative permeability data. This study proposes a new relative permeability model for gas hydrate-bearing media that is a function of maximum capillary pressure, capillary entry pressure, pore size distribution index, residual saturations, hydrate saturation, and four other constants. The three novel features of the proposed model are: (i) requires fitting its six empirical parameters only once using experimental data from any single S h , and the same set of empirical parameters predict relative permeability at all S h , (ii) includes the effect of capillarity, and (iii) includes the effect of pore-size distribution. From practical standpoint, the model can be used to simulate multiphase flow in gas hydrate-bearing sediments where the proposed relative permeability can account for the evolving hydrate saturation. The proposed model is implemented in a numerical simulator and the wall time required to perform simulations using the proposed model is shown to be similar to the time it takes to run same simulations with the B-C model. The proposed model is a step forward towards achieving the goal of physically accurate modeling of multiphase flow for gas hydrate-bearing sediments that accounts for the effect of gas hydrate saturation change on relative permeability.

54 ENVIRONMENTAL SCIENCES↗

A microfluidic platform for the synthesis of polymer and polymer-protein-based protocells

In this study, we demonstrate the fabrication of polymersomes, protein-blended polymersomes, and polymeric microcapsules using droplet microfluidics. Polymersomes with uniform, single bilayers and controlled diameters are assembled from water-in-oil-in-water double-emulsion droplets. This technique relies on adjusting the interfacial energies of the droplet to completely separate the polymer-stabilized inner core from the oil shell. Protein-blended polymersomes are prepared by dissolving protein in the inner and outer phases of polymer-stabilized droplets. Cell-sized polymeric microcapsules are assembled by size reduction in the inner core through osmosis followed by evaporation of the middle phase. All methods are developed and validated using the same glass-capillary microfluidic apparatus. This integrative approach not only demonstrates the versatility of our setup, but also holds significant promise for standardizing and customizing the production of polymer-based artificial cells.

36 MATERIALS SCIENCE↗

Comparative study between experimental measurements and model predictions of bubble rise velocity in molten LiCl-KCl

This research investigated the shape and rise velocities of gas bubbles (helium, nitrogen, argon, and krypton) in molten LiCl-KCl at 500 °C using a specialized optical visualization apparatus. The apparatus features a custom quartz rectangular prism cell housed in a furnace, enabling the application of the shadowgraph measurement technique. Bubbles with diameters between 0.45 and 3.2 mm were produced via a capillary, and their equivalent diameters and rise velocities were analyzed using high-resolution imaging and centroid tracking algorithms. Important non-dimensional parameters were calculated to characterize behavior. Bubbles with 0.03 < Eo < 1.32, 17 < Re < 718, and Mo order of 10 -11 were generated in the molten LiCl-KCl, revealing that bubbles with diameters less than 1.46 mm remain spherical, whereas those with larger diameters are ellipsoidal. The transition and oscillation onset for bubble shape occurred at larger diameters than those previously observed in air–water systems. Comparative analysis of the gas-molten salt data against existing air–water bubble rise velocity correlations highlighted inaccuracies in predictions, particularly across the different bubble regimes. An existing correlation was calibrated to the molten salt data to improve the bubble velocity predictions. In conclusion, this study contributes essential experimental data for the design and safety evaluation of molten salt reactors and offers insights for the optimization of sparge systems for fission product removal.

Bubble rise velocity↗

FY2022 Progress on Imbibition Testing in Containment Science

Estimation of two-phase fluid flow properties is important to understand and predict water and gas movement through the vadose zone for agricultural, hydrogeological, and engineering applications, such as for vapor-phase contaminant transport and/or containment of noble gases in the subsurface. In this second progress report of FY22, we present two ongoing activities related to imbibition testing on volcanic rock samples. We present the development of a new analytical solution predicting the temperature response observed during imbibition into dry samples, as discussed in our previous first progress report for FY22. We also illustrate the use of a multi-modal capillary pressure distribution to simulate both early- and late-time imbibition data collected on tuff core that can exhibit multiple pore types. These FY22 imbibition tests were conducted for an extended period (i.e., far beyond the time required for the wetting front to reach the top of the sample), which is necessary for parameter estimation and characterization of two different pore types within the samples.

42 ENGINEERING↗

Reconstructing the reflectivity of liquid surfaces from grazing incidence X-ray off-specular scattering data

The capillary wave model of a liquid surface predicts both the X-ray specular reflection and the diffuse scattering around it. A quantitative method is presented to obtain the X-ray reflectivity (XRR) from a liquid surface through the diffuse scattering data around the specular reflection measured using a grazing incidence X-ray off-specular scattering (GIXOS) geometry at a fixed horizontal offset angle with respect to the plane of incidence. With this approach the entire Q z -dependent reflectivity profile can be obtained at a single, fixed incident angle. This permits a much faster acquisition of the profile than with conventional reflectometry, where the incident angle must be scanned point by point to obtain a Q z -dependent profile. The XRR derived from the GIXOS-measured diffuse scattering, referred to in this paper as pseudo-reflectivity, provides a larger Q z range compared with the reflectivity measured by conventional reflectometry. Transforming the GIXOS-measured diffuse scattering profile to pseudo-XRR opens up the GIXOS method to widely available specular XRR analysis software tools. Here the GIXOS-derived pseudo-XRR is compared with the XRR measured by specular reflectometry from two simple vapor–liquid interfaces at different surface tension, and from a hexadecyltrimethylammonium bromide monolayer on a water surface. For the simple liquids, excellent agreement (beyond 11 orders of magnitude in signal) is found between the two methods, supporting the approach of using GIXOS-measured diffuse scattering to derive reflectivities. Pseudo-XRR obtained at different horizontal offset angles with respect to the plane of incidence yields indistinguishable results, and this supports the robustness of the GIXOS-XRR approach. The pseudo-XRR method can be extended to soft thin films on a liquid surface, and criteria are established for the applicability of the approach.

36 MATERIALS SCIENCE↗

High accuracy in-situ direct gas analysis of Li-ion batteries

Cycling of lithium-ion batteries containing Ni-rich NMC cathodes at high voltage involves intense gas generation. From the safety standpoint, it is critical to understand how different gas species respond to changes of upper cut-off voltages. In this manuscript, we introduce a novel experimental set up for real-time analysis of gas generation in prismatic pouch cells. In a typical experiment, a lithium-ion pouch cell is directly connected to a quadruple mass spectrometer by glass capillary. Pressure difference helps move the generated gases to the mass spectrometer column for full analysis. The gaseous species are probed during both formation cycle and aging cycles in Li-ion pouch cells comprising NMC811 cathode and graphite anode. The gases are generated upon the creation of the solid electrolyte interphase on graphite during the first formation charge. Besides ethylene gas, C 2 H 4 , whose occurrence is related to the decomposition of ethylene carbonate, a minor solvent decomposition happened at a lower voltage is demonstrated to be associated with residue water on the electrode. For aging cycles, three upper cut-off voltages have been selected to investigate the gas evolution behavior upon charging to 4.2, 4.4 and 4.6 V. Higher upper cut-off voltages do not affect the amount of O 2 measured as a part of the generated oxygen could have reacted with electrolytes. Quite similar and low amounts of O 2 remain in the cells upon charging to the selected cut-off voltages. On the other hand, the generation of CO 2 has been found to be very sensitive to upper cut-off voltage. During similar aging cycles, 6167 nmol $g_{NMC}^{-1}$ of CO 2 is generated at 4.6 V, versus 1650 nmol $g_{NMC}^{-1}$ of CO 2 at 4.4 V, versus 91 nmol $g_{NMC}^{-1}$ of CO 2 at 4.2 V.

25 ENERGY STORAGE↗

Preparation of illite coated geomaterial microfluidic surfaces: Effect of salinity and heat treatment

Unique characteristics of clay (e.g., high surface area, deficiency in positive charges) make any clay abundant shales a good source of adsorbed gas. However, the presence of clay in porous media can also affect shale rock's producibility. The clay-water interaction can cause significant swelling and fines migration in the formation and impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surfaces with geomaterials (e.g., calcite, Quartz, clay), can represent the physicochemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. Here, this study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C), and the results are compared with an untreated coated surface. Flooding tests were carried out with brines of different salinities on the coated surface to evaluate the stability of the coating. The experimental results indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗

Droplet formation simulation using mixed finite elements

Droplet formation happens in finite time due to the surface tension force. The linear stability analysis is useful to estimate the size of a droplet but fails to approximate the shape of the droplet. This is due to a highly nonlinear flow description near the point where the first pinch-off happens. A one-dimensional axisymmetric mathematical model was first developed by Eggers and Dupont [“Drop formation in a one-dimensional approximation of the Navier–Stokes equation,” J. Fluid Mech. 262, 205–221 (1994)] using asymptotic analysis. This asymptotic approach to the Navier–Stokes equations leads to a universal scaling explaining the self-similar nature of the solution. Numerical models for the one-dimensional model were developed using the finite difference [Eggers and Dupont, “Drop formation in a one-dimensional approximation of the Navier–Stokes equation,” J. Fluid Mech. 262, 205–221 (1994)] and finite element method [Ambravaneswaran et al., “Drop formation from a capillary tube: Comparison of one-dimensional and two-dimensional analyses and occurrence of satellite drops,” Phys. Fluids 14, 2606–2621 (2002)]. The focus of this study is to provide a robust computational model for one-dimensional axisymmetric droplet formation using the Portable, Extensible Toolkit for Scientific Computation. The code is verified using the Method of Manufactured Solutions and validated using previous experimental studies done by Zhang and Basaran [“An experimental study of dynamics of drop formation,” Phys. Fluids 7, 1184–1203 (1995)]. The present model is used for simulating pendant drops of water, glycerol, and paraffin wax, with an aspiration of extending the application to simulate more complex pinch-off phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PREPARATION OF CLAY-COATED GLASS SURFACES FOR MICROFLUIDICS-BASED STUDY ON CLAY-FLUID INTERACTIONS

Unique characteristics of clay, even though make any clay abundant shales a good source of adsorbed gas, make them equally difficult to produce. The clay-water interaction can cause significant swelling and fines migration in the shale formation, both of which can significantly impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surface with geomaterials (e.g., calcite, quartz, clay) can represent the physico-chemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. This study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay minerals to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt.% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C). Dynamic flooding tests were carried out with brines on the coated surface to evaluate the stability of the coating. The experiments' outcome indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗