Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Conservation of model degraded pine wood with selected organosilicons studied by XFM and nanoindentation

Previous research found that some organosilicon treatments proved effective in stabilizing waterlogged wood dimensions during drying. The present research aimed to determine the mechanism of wood stabilization by these chemicals to understand their mode of action. Here, the study used chemically (ChP) and biologically degraded (BP) model Scots pine wood treated with Methyltrimethoxysilane (MTMS), (3-Mercaptopropyl) trimethoxysilane (MPTMS), or 1,3-Bis(diethylamino)-3-propoxypropanol)-1,1,3,3-tetramethyldisiloxane (DEAPTMDS). Synchrotron-based X-ray fluorescence microscopy (XFM) was used to investigate the penetration of organosilicons into the wood cellular structure and cell walls, and nanoindentation was used to study the mechanical properties of the treated wood cell walls. All treatments resulted in high volumetric anti-shrink efficiency (ASE V ) values of 74-82%, except for MTMS-treated ChP with an ASE V of 52%. The multiscale XFM results revealed that all applied organosilicons penetrated throughout the whole wooden blocks and deposited in both cell lumina and cell walls. The retention of all applied organosilicons was highest in BP wood, and so was the dimensional stabilization effect. MTMS-treated ChP had the lowest measured cell wall infiltration, which likely contributed to its lower ASE v . DEAPTMDS treatments plasticized the cell walls and resulted in lowered nanoindentation elastic modulus (E s NI ) and hardness (H) for all types of wood. MTMS and MPTMS had modest effects on cell wall mechanical properties, and the effect depended on the type of wood. The final effect of organosilicon treatment on the dimensional wood stabilization and mechanical properties of wood cell walls depended not only on the type of the applied organosilicon but also the type of wood degradation. This means that the treatment cannot be considered universal, and specific approaches are needed for the conservation of individual wooden objects. Although some mechanisms are now better understood, such as the need for organosilicons to infiltrate the cell walls and the plasticizing effect of DEAPTMDS, other aspects will benefit from a more detailed analysis of the molecular interactions between organosilicons and wood polymers.

59 BASIC BIOLOGICAL SCIENCES↗

Amplified spontaneous emission measurement of a line-narrowed, tunable, Ti:Al2O3 amplifier using rubidium absorption

Amplified spontaneous emission, ASE, generated by a Ti:Al2O3 laser amplifier has been measured as a function of pump energy, and thus gain, using the atomic absorption of rubidium, Rb, gas at 0.780 micron. By tuning the Ti:Al2O3 laser, the Rb cell could selectively absorb the narrow spectral bandwidth laser radiation while transmitting the wide spectral bandwidth ASE. Transmission of laser amplifier pulses through a Rb absorption cell, measured at various temperatures, thus allows the measurement of the weak ASE in the vicinity of the strong laser pulse. A model for the transmission of Rb as a function of temperature and wavelength has been developed. The measured transmissions are in good agreement with the transmission model predictions.

Barnes, James C.↗

Evaluation of Mobile Phone Interference With Aircraft GPS Navigation Systems

This report compiles and analyzes tests that were conducted to measure cell phone spurious emissions in the Global Positioning System (GPS) radio frequency band that could affect the navigation system of an aircraft. The cell phone in question had, as reported to the FAA (Federal Aviation Administration), caused interference to several GPS receivers on-board a small single engine aircraft despite being compliant with data filed at the time with the FCC by the manufacturer. NASA (National Aeronautics and Space Administration) and industry tests show that while there is an emission in the 1575 MHz GPS band due to a specific combination of amplifier output impedance and load impedance that induces instability in the power amplifier, these spurious emissions (i.e., not the intentional transmit signal) are similar to those measured on non-intentionally transmitting devices such as, for example, laptop computers. Additional testing on a wide sample of different commercial cell phones did not result in any emission in the 1575 MHz GPS Band above the noise floor of the measurement receiver.

Pace, Scott↗

Computer vision models and advanced TEM imaging for microstructures of irradiated AM316 stainless steels

Advancements were made in automating microscopy-based material characterization, particularly in studying irradiation effects on additively manufactured (AM) materials using machine learning (ML) and computer vision (CV). These automation efforts address the challenges of analyzing complex microstructures, accelerating the detection of irradiation-induced defects. Two CV models were developed at Argonne National Laboratory (ANL) to enhance transmission electron microscopy (TEM) analysis of irradiated AM 316 stainless steel. The first model focused on the detection of irradiation-induced dislocation loops, which contribute to material hardening and embrittlement. These loops, categorized as faulted or perfect, were automatically detected and classified using a Mask R-CNN model trained on TEM images from both in-situ and ex-situ ion irradiation experiments. The model achieved high accuracy, with precision, recall, and F1 scores of 0.839, 0.734, and 0.776, respectively, demonstrating its effectiveness in analyzing dislocation loops in irradiated AM materials. The second CV model was developed to analyze the size and wall thickness of dislocation cells in laser powder bed fusion (LPBF) 316 stainless steel. Using a U-Net++ architecture with EfficientNet as the encoder, the model was trained on TEM images to segment and measure cell size and wall thickness.

36 MATERIALS SCIENCE↗

Lunar and Planetary Science XXXV: Meteorites: Experiments and Spectroscopy

The session "Meteorites: Experiments and Spectroscopy" included the following reports:The Suitability of Laser Induced Breakdown Spectroscopy for Determining the Compositions of Extraterrestrial Material; Deconvolving Terrestrial Alteration Mineral Spectral Signatures from Meteorite Reflectance Measurements; Impacts of Ions and Micrometeorites on Mineral Surfaces: Reflectance and Chemical Changes Found in Ordinary Chondrites; FT-IR Micro-spectroscopy of Fine-grained Planetary Materials: Further Results; Effusion Cell Measurements of the Vapor Pressure of Cobalt at Temperatures up to 2000K: Comparisons with Iron and Nickel; Kinetics of Fe2+-Mg Order-Disorder in P21/c Pigeonite: Implications for Cooling Rates Calculations; Compressional and Shear Wave Velocities in Meteorites; Chemical and Mineralogical Size Segregation in the Impact Disruption of Anhydrous Stone Meteorites; and Shock Pressures of Impacts vs. Crystallization Pressures of Shock-induced Melt Veins of the chondrites.

Source record↗

Insulation bonding test system

A method and a system for testing the bonding of foam insulation attached to metal is described. The system involves the use of an impacter which has a calibrated load cell mounted on a plunger and a hammer head mounted on the end of the plunger. When the impacter strikes the insulation at a point to be tested, the load cell measures the force of the impact and the precise time interval during which the hammer head is in contact with the insulation. This information is transmitted as an electrical signal to a load cell amplifier where the signal is conditioned and then transmitted to a fast Fourier transform (FFT) analyzer. The FFT analyzer produces energy spectral density curves which are displayed on a video screen. The termination frequency of the energy spectral density curve may be compared with a predetermined empirical scale to determine whether a igh quality bond, good bond, or debond is present at the point of impact.

Beggs, J. M.↗

A Heritage BioSensor for Lunar Biology Experiments

Introduction: Automated biological experiments on small spacecraft missions have gained prominence over the past decade due to their simplicity, accessibility, and small mass, volume, and power needs. Most recently, the BioSensor microfluidic CubeSat payload aboard BioSentinel used an automated microfluidic cell culture system to study the effects of environmental stressors like deep space radiation and microgravity on yeast growth and metabolism. BioSentinel’s successor, the Lunar Explorer Instrument for space biology Applications (LEIA), will study the effects of lunar gravity and radiation using an improved version of the BioSensor microfluidic platform. The BioSensor payload has great adaptability to host a diverse range of biological experiments with single- and multi-celled organisms in both crewed and uncrewed missions, making it a compelling candidate for future space biology studies in a lunar surface environment. BioSensor Instrumentation on BioSentinel: The first spaceflight mission with the BioSensor, BioSentinel’s biology experiments occurred at three locations -- deep space, ISS and ground. The payload contained 18 microfluidic cards, each featuring 16 growth wells (a total of 288 growth wells). Each well was loaded before launch with desiccated yeast. In space, liquid culture medium (nutrients) was automatically introduced to batches of wells at a time to initiate a series of biology experiments. Temperature was maintained by thin film heaters on both sides of each card. Each well was equipped with three LEDs emitting at 570 nm, 630 nm, and 850 nm, paired with photodetectors to measure cell concentration and the alamarBlue (metabolic indicator dye) color transition from blue to pink. Phenotypic parameters like cell viability, metabolic rate, and generation time can be derived from these measurements. The sequence and timing of fluid fills, optical measurements, and thermal control were stored onboard, but could be updated asynchronously via ground communication. LEIA: LEIA is slated for launch no earlier than 2026 on a CLPS lander. BioSentinel’s BioSensor has been modified for use in LEIA. These improvements include: (a) storage for multiple culture medium types, (b) additional LED color (465 nm) for a new biological assay for antioxidant (carotenoid) production, (c) housing modifications for later biology load before launch, (d) improved isolation between electronic and fluidic components, and (e) improved humidity control for prolonged organism viability in case of post-load launch delay. Future Prospects: The consistent and successful demonstration of complex fluidics platforms alongside reliable instrument operations in a space environment is poised to create strong momentum for BioSensor-based biological experiment payloads. Planned future developments with the BioSensor include extending compatibility to a broader range of organisms and assays. Preliminary work has already demonstrated successful growth of Arabidopsis seedlings in fluidic cards. With a few modifications to the optical assembly, the setup could easily measure photosynthetic traits in plants and cyanobacteria. The addition of fluorescence measurements and generation of novel luminescent assays will elevate BioSensor’s functionality further. Beyond the BioSensor’s potential uses on free-flyer missions, ISS and Gateway, and CLPS landers, deploying the BioSensor to the lunar surface or in an artificial habitat on crewed missions could enable pioneering research on both how life responds to lunar conditions and future bioproduction capabilities making the BioSensor an indispensable tool for future space biology research.

Chinmayee Govinda Raj↗

Evaluation of an LED Simulator for Single- and Multi-Junction PV Cell Performance Testing

We present the evaluation of a solar simulator comprising a Light Emitting Diode (LED) array as its light source. While multiple applications can be envisioned for such a light source, here we focus on its use for performance testing of solar cells at Standard Test Conditions. With this in mind, we present characterization of the spatial uniformity of the irradiance and its temporal stability as well as the spectral range and spectral class. For a multisource simulator, the spectral uniformity across the test plane should also be evaluated and we discuss a method for performing this evaluation that is well suited to a solar cell performance testing application. One major advantage of this simulator is the ability to easily adjust the spectral output as needed in multijunction PV cell measurements and we also discuss this application here.

LED↗

Radiation damage annealing kinetics

Various spectral response studies are reported that assess lithium doping effects on the recovery process of electron damaged silicon solar cells. Measurements of both the minority carrier lifetimes and the energy level spectrum of the defects are used to predict lifetime damage constants and carrier removal rates relevant to the operation of the solar lithium-doped cell and its annealing kinetics.

Dresselhaus, M. S.↗

The dual role of iron in alkaline water electrolysis: A friend or a foe?

Trace iron (Fe) impurities pose a challenge in alkaline water electrolysis (AWE) and can significantly impact long-term performance, yet their comprehensive system-level effects remain poorly understood. Here, we present the mechanistic roles of Fe in AWE, using combined rotation disk electrode studies, zero-gap cell measurements, and durability tests up to 1,000 h. Fundamental electrochemistry shows that Fe deposition proceeds through a solution-mediated pathway, with dendritic growth triggered under specific mass-transport and potential conditions. In single-cell operation, Fe incorporation substantially enhances nickel (Ni)-based anode activity by forming highly active Ni-Fe oxyhydroxides, while cathodic Fe forms either thin films or dendrites, depending on potential, surface morphology, and electrolyte distribution. Although dendrites do not degrade hydrogen evolution performance up to 1,000 h, they reveal partial intrusion into the separator, indicating a potential durability risk. We identify five governing factors controlling Fe dendrite formation and provide design principles for impurity-resilient AWE systems.

Lyu, Xiang [ORNL] (ORCID:0000000208673248)↗

A Summary of the International Workshops on Space Solar Cell Calibration and Measurement Techniques

The first two of a planned series of international workshops concerning space solar cell calibration and measurement techniques have been held within the past year. The need for these workshops arose from the increasing complexity of space solar cells coupled with the growing international nature of the market for space cells and arrays. The workshops, jointly sponsored by NASDA, ESA and NASA, have the objective of obtaining international agreement on standardized values for the AM0 spectrum and constant, recommendations for laboratory measurement practices and the establishment of a set of protocols for making interlaboratory comparison measurements. The results of the first two workshops, held in Waikiki, Hawaii, USA in 1994 and Madrid, Spain in 1995, are presented.

Brinker, D. J.↗

The advancing wave front on a sloping channel covered by a rod canopy following an instantaneous dam break

The drag coefficient Cd for a rigid and uniformly distributed rod canopy covering a sloping channel following the instantaneous collapse of a dam was examined using flume experiments. The measurements included space x and time t high resolution images of the water surface h(x, t) for multiple channel bed slopes So and water depths behind the dam Ho along with drag estimates provided by sequential load cells. Using these data, an analysis of the Saint-Venant equation (SVE) for the front speed was conducted using the diffusive wave approximation. An inferred Cd=0.4 from the h(x, t) data near the advancing front region, also confirmed by load cell measurements, is much reduced relative to its independently measured steady-uniform flow case. This finding suggests that drag reduction mechanisms associated with transients and flow disturbances are more likely to play a dominant role when compared to conventional sheltering or blocking effects on Cd examined in uniform flow. The increased air volume entrained into the advancing wave front region as determined from an inflow–outflow volume balance partly explains the Cd reduction from unity.

Mechanics↗

BioSentinel: An Adaptable Platform for Studying the Biological Effects of Deep Space Radiation

NASA's BioSentinel mission is a 6U nanosatellite with autonomous life support that will utilize the budding yeast Saccharomyces cerevisiae to study the DNA damage response to the deep space radiation environment. BioSentinel is planned to launch in 2019 as a secondary payload on the Space Launch System's first Exploration Mission (EM-1), and will undergo a lunar fly-by and enter heliocentric orbit after deployment. As the first biological mission beyond Low Earth Orbit (LEO) in nearly half a century, this mission will help fill critical gaps in knowledge about the effects of uniquely composed, chronic, low-flux deep space radiation on biological systems. Yeast is well-suited for this mission due to its desiccation tolerance and space-flight heritage. As a eukaryotic model organism, it also serves as a robust analog for human cells. Data gathered on this mission will thus inform us of the hazards involved in long-duration human exploration in deep space, and the protections necessary to mitigate them. Due to its low-cost, flexible and advanced technology, the 4U BioSensor payload contained within the nanosatellite is adaptable to other model microorganisms, exploration platforms and environments relevant to human exploration, such as the ISS, the Lunar Orbital Platform - Gateway and future lunar landers. In order to query the DNA damage response to deep space radiation, BioSentinel contains a wild type yeast strain as a positive control, and a radiation sensitive rad51 mutant strain that is defective for DNA repair. Yeast cells are desiccated in microfluidic cards, and rehydrated with growth medium and metabolic indicator dye at the desired time points during the mission. A thermal control system supports these stasis and growth states, and an optical system continuously measures cell growth and metabolism. An onboard radiation spectrometer and dosimeter allows us to correlate the dose, energy and particle-type of deep space radiation to the biological response. Data received from the deep space biosensor will be compared to control payloads on Earth and the ISS. Ongoing science testing for the BioSentinel project includes optimization for cell viability, desiccation tolerance, and long-term biocompatibility, as well as radiation experiments to understand the sensitivity and responsiveness of cells to varying radiation doses and particle types.

BioSentinel↗

Operando detection of Li plating during fast charging of Li-ion batteries using incremental capacity analysis

A major challenge that limits fast charging of Li-ion batteries is lithium (Li) plating on the graphite electrode. Furthermore, it remains challenging to detect and diagnose Li plating in operando during charging. In this work, incremental capacity (IC) analysis is applied while charging graphite-NMC pouch cells over a range of rates from C/2 to 4C. Three-electrode pouch cell measurements and post-mortem SEM imaging was performed to demonstrate that the onset of Li plating is correlated with a specific IC peak. IC analysis was also applied to study the fast-charge performance of multi-layer pouch cells with 3-D anode architectures. The results demonstrate that: 1) IC curves have a characteristic peak that is an indicator of Li plating during fast charging, which grows in magnitude as charging rate increases; 2) the plating IC peak correlates with the voltage minimum of the graphite anode, indicating a transition from intercalation to plating; 3) the plating IC peak is sensitive to small amounts of Li plating; 4) IC analysis can be applied to study Li plating in novel cell architectures; 5) the plating IC peak evolves during extended fast-charge cycling, which is a result of reduced Li plating as the Li inventory decreases.

25 ENERGY STORAGE↗

PV Reference Cells for Outdoor Use: Comparison of First-Year Field Measurements

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as low-cost alternatives to thermopile pyranometers. But reference cell characteristics, such as directional and spectral response, fundamentally differ from pyranometers, and measurements made by the former cannot be substituted for or directly compared with the latter. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of multiple products from different manufacturers that are mounted at a fixed tilt, on a single-axis tracker, and on a dual-axis tracker. This report provides an analysis of the data collected during the first year of operation at the NREL location. An overall assessment is made by comparing the total energy measured by each instrument to the other instruments having the same orientation. These totals are calculated for three different scenarios: (1) using the factory calibration factors, (2) using the previously determined NREL Cell Lab calibration factors, and (3) using the newly determined field calibration factors derived from the recorded measurements. Because the true or correct measurement values are unknown, pair-wise comparisons are made. The results show that the difference between the highest and lowest measured energy can exceed 3% when using the factory calibration factors. Consistency among instruments improves when Cell Lab calibrations are used, and it further improves when using field calibration factors.

14 SOLAR ENERGY↗

Large Area Near‐Field Thermophotovoltaics for Low Temperature Applications

Abstract Thermophotovoltaics, devices that convert thermal infrared photons to electricity, offer a key pathway for a variety of critical renewable energy technologies including thermal energy storage, waste heat recovery, and direct solar‐thermal power generation. However, conventional far‐field devices struggle to generate reasonable powers at lower temperatures. Near‐field thermophotovoltaics provide a pathway to substantially higher powers by leveraging photon tunneling effects. Here a large area near‐field thermophotovoltaic device is presented, created with an epitaxial co‐fabrication approach, that consists of a self‐supported 0.28 cm 2 emitter‐cell pair with a 150 nm gap. The device generates 1.22 mW at 460 °C, a 25‐fold increase over the same cell measured in a far‐field configuration. Furthermore, the near‐field device demonstrates short circuit current densities greater than the far‐field photocurrent limit at all the temperatures tested, confirming the role of photon tunneling effects in the performance enhancement. Modeling suggests several practical directions for cell improvements and further increases in power density. These results highlight the promise of near‐field thermophotovoltaics, especially for low temperature applications.

36 MATERIALS SCIENCE↗

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

Fuel Cell Power Plant Initiative: Solid Oxide Fuel Cell/Logistics Fuel Processor 27 kWe Power System Demonstration for ARPA - Volume 1

This report describes the successful testing of a 27 kWe Solid Oxide Fuel Cell (SOFC) generator fueled by natural gas and/or a fuel gas produced by a brassboard logistics fuel preprocessor (LFP). The test period began on May 24, 1995 and ended on February 26, 1996 with the successful completion of all program requirements and objectives. During this time period, this power system produced 118.2 MWh of electric power. No degradation of the generator's performance was measured after 5582 accumulated hours of operation on these fuels: local natural gas - 3261 hours, jet fuel reformate gas - 766 hours, and diesel fuel reformate gas - 1555 hours. This SOFC generator was thermally cycled from full operating temperature to room temperature and back to operating temperature six times, because of failures of support system components and the occasional loss of test site power, without measurable cell degradation. Numerous outages of the LFP did not interrupt the generator's operation because the fuel control system quickly switched to local natural gas when an alarm indicated that the LFP reformate fuel supply had been interrupted. The report presents the measured electrical performance of the generator on all three fuel types and notes the small differences due to fuel type. Operational difficulties due to component failures are well documented even though they did not affect the overall excellent performance of this SOFC power generator. The final two appendices describe in detail the LFP design and the operating history of the tested brassboard LFP.

Veyo, S.E.↗