Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Inexpensive Meter for Total Solar Radiation

Pyranometer containing solar cells measures combined intensity of direct light from Sun and diffuse light from sky. Instrument includes polyethylene dome that diffuses entering light so output of light detectors does not vary significantly with changing angle of Sun during day. Not to be calibrated for response of each detector to Sun angle, and sensor outputs not corrected separately before summed and integrated. Aids in deciding on proper time to harvest crops.

Laue, E. G.↗

Effects on motor unit potentiation and ground reaction force from treadmill exercise

This study was conducted to analyze the characteristics of motor unit potentiation (MUP) and ground reaction force (GRF) in treadmill exercise at the inclines of 0, 5.5 and 11 percent with conjuctive speeds of 7.5, 6, and 5 mph respectively. These speeds and corresponding inclines were set to provide equivalent physiological workloads at 12.5 METS. EMG recordings were taken from the rectus femoris and gastrocnemius of the right leg from 5 subjects. Simultaneous GRF recordings were obtained from a Delmar Avionic treadmill rigged with load cells. Measures for MUP and GRF were taken over a period containing 10 strides at steady pace. It was concluded that the gastrocnemius was more evident in EMG activity in all speed/incline settings over the rectus femoris, and that inclines from 5.5 to 11 percent produced greater GRF's over 0 percent. Recommendations for future studies was made.

Elam, Reid P.↗

Modelling and design of high performance indium phosphide solar cells

A first principles pn junction device model has predicted new designs for high voltage, high efficiency InP solar cells. Measured InP material properties were applied and device parameters (thicknesses and doping) were adjusted to obtain optimal performance designs. Results indicate that p/n InP designs will provide higher voltages and higher energy conversion efficiencies than n/p structures. Improvements to n/p structures for increased efficiency are predicted. These new designs exploit the high absorption capabilities, relatively long diffusion lengths, and modest surface recombination velocities characteristic of InP. Predictions of performance indicate achievable open-circuit voltage values as high as 943 mV for InP and a practical maximum AM0 efficiency of 22.5 percent at 1 sun and 27 C. The details of the model, the optimal InP structure and the effect of individual parameter variations on device performance are presented.

Rhoads, Sandra L.↗

Diagnosis Of A Pressure-Modulator-Radiometer Cell

Spectral response of pressure-modulator-radiometer cell measured with help of lead-salt tunable diode laser. Laser chosen because of narrow bandwidths {2 x 10 to negative 4th power (cm) to negative 1st power} and relatively high powers (up to 1 mW continuous) of such lasers and because available for wavelengths from 3 to 30 micrometers. Direct measurement of spectral response enables formulation of more-precise atmospheric-transmission functions, enabling extraction of better information from readings taken with instrument.

May, Randy D.↗

Metabolic alterations induced in cultured skeletal muscle by stretch-relaxation activity

Muscle cells differentiated in vitro are repetitively stretched and relaxed in order to determine the presence of short- and long-term alterations occurring in glucose uptake and lactate efflux that are similar to the metabolic alterations occurring in stimulated organ-cultured muscle and in vivo skeletal muscle during the active state. It is observed that whereas mechanical stimulation increases these metabolic parameters within 4-6 h of starting activity, unstimulated basal rates in control cultures also increase during this period of time, and by 8 h, their rates have reached or exceeded the rates in continuously stimulated cells. Measurements of these parameters in media of different compositions show that activity-induced long-term alterations in the parameters occur independently of growth factors in serium and embryo extracts.

Hatfaludy, Sophia↗

Study of a cesium plasma as a selective emitter for thermophotovoltaic applications

This experimental study evaluates the potential of a cesium plasma as an emitter for a thermophotovoltaic (TPV) energy conversion system. A cesium plasma, as a result of the ground-state transitions of its single outer-shell electron, produces large amounts of radiation in the 850-890-nm wavelength region. This would provide excellent coupling to silicon, gallium arsenide, and indium phosphide photovoltaic cells. Measurements of the radiative efficiency, the sum of the power at the 852 and 894 nm wavelengths relative to the total emitted power, were made and correlated to the plasma operating variables. It was determined that, for atomic density in the range (3-6) x 10 exp 21/cu cm and electron temperature in the range 2000-3000 K, radiative efficiencies in excess of 70 percent are attainable. This would indicate that a cesium plasma with its selective emission characteristics and low electron operating temperatures of 2000-3000 K would be an excellent candidate as an emitter in a TPV system.

Lowe, R.↗

Thrust stand evaluation of engine performance improvement algorithms in an F-15 airplane

Results are presented from the evaluation of the performance seeking control (PSC) optimization algorithm developed by Smith et al. (1990) for F-15 aircraft, which optimizes the quasi-steady-state performance of an F100 derivative turbofan engine for several modes of operation. The PSC algorithm uses onboard software engine model that calculates thrust, stall margin, and other unmeasured variables for use in the optimization. Comparisons are presented between the load cell measurements, PSC onboard model thrust calculations, and posttest state variable model computations. Actual performance improvements using the PSC algorithm are presented for its various modes. The results of using PSC algorithm are compared with similar test case results using the HIDEC algorithm.

Conners, Timothy R.↗

Force reflecting hand controller for manipulator teleoperation

A force reflecting hand controller based upon a six degree of freedom fully parallel mechanism, often termed a Stewart Platform, has been designed, constructed, and tested as an integrated system with a slave robot manipulator test bed. A force reflecting hand controller comprises a kinesthetic device capable of transmitting position and orientation commands to a slave robot manipulator while simultaneously representing the environmental interaction forces of the slave manipulator back to the operator through actuators driving the hand controller mechanism. The Stewart Platform was chosen as a novel approach to improve force reflecting teleoperation because of its inherently high ratio of load generation capability to system mass content and the correspondingly high dynamic bandwidth. An additional novelty of the program was to implement closed loop force and torque control about the hand controller mechanism by equipping the handgrip with a six degree of freedom force and torque measuring cell. The mechanical, electrical, computer, and control systems are discussed and system tests are presented.

Bryfogle, Mark D.↗

Application of Ni-63 photo and corona discharge ionization for the analysis of chemical warfare agents and toxic wastes

Over the past decade, advances in instrumental design and refinements in the understanding of ion molecule reactions at atmospheric pressure enabled the application of Ion Mobility Spectrometry (IMS) as a simple inexpensive and sensitive analytical method for the detection of organic trace compounds. Positive and negative gas-phase ions for ion mobility spectrometry have been produced by a variety of methods, including photo-ionization, laser multi photon ionization, surface ionization, corona discharge ionization. The most common ion source used in ion mobility spectrometry is a radioactive Ni-63 foil which is favored due to simplicity, stability, convenience, and high selectivity. If reactant ions like (H2O(n)H)(+) or (H2O(n)O2)(-) dominate in the reaction region, nearly all kinds of compounds with a given proton or electron affinity; are ionized. However, the radioactivity of the Ni-63 foil is one disadvantage of this ion source that stimulates the development and application of other ionization techniques. In this paper, we report analyses of old chemical warfare agents and toxic wastes using Bruker RAID ion mobility spectrometers. Due to the modular construction of the measuring cell, the spectrometers can be equipped with different ion sources. The combined use of Ni-63, photo- and corona discharge ionization allows the identification of different classes of chemical compounds and yields in most cases comparable results.

Stach, J.↗

Flight data from the PASP-Plus experiment

The photovoltaic array space power (PASP)-Plus solar cell flight experiment is described, and the observed performances of different solar cell types during the first six months of their operation, are summarized. The solar cell types include single crystal and amorphous silicon, GaAs, several multijunction cell types, indium phosphide and GaAs/GaSb concentrator cells. The radiation degradation experienced by some of the solar cell types agrees with theoretical predictions. Other samples, including silicon, are degraded less than predicted. Effects, including the increase in temperature of all the experiments and the effect of sun glint on cell measurement, are discussed.

Marvin, D. C.↗

[Measurement of Speed and Direction of Ocean Surface Winds Using Quik Scat Scatterometer]

The SeaWinds on QuikSCAT scatterometer was developed by NASA JPL to measure the speed and direction of ocean surface winds. Simulations performed to estimate the performance of the instrument prior to its launch have indicated that the mid-swath accuracy is worse than that of the rest of the swath. This behavior is a general characteristic of scanning pencil beam scatterometers. For SeaWinds, the accuracy of the rest of the swath, and the size of the swath are such that the instrument meets its science requirements despite mid-swath shortcomings. However, by understanding the problem at mid-swath, we can improve the performance there as well. We discuss the underlying causes of the problem in detail and propose a new wind retrieval algorithm which improves mid-swath performance. The directional discrimination ability of the instrument varies with cross track distance wind speed, and direction. By estimating the range of likely wind directions for each measurement cell, one can optimally apply information from neighboring cells where necessary in order to reduce random wind direction errors without significantly degrading the resolution of the resultant wind field. In this manner we are able to achieve mid-swath RMS wind direction errors as low as 15 degrees for low winds and 10 degrees for moderate to high winds, while at the same time preserving high resolution structures such as cyclones and fronts.

Stiles, Bryan↗

A Probabilistic Technique for Improving the Mid-Swath Wind Direction Accuracy of Scanning Pencil Beam Scatterometers

The SeaWinds on QuikSCAT scatterometer is a device developed by NASA JPL to measure the speed and direction of ocean surface winds. Simulations performed in order to determine the expected performance of the instrument prior to its launch have indicated that the accuracy of the retrieved wind vectors varies across the swath. In particular the mid-swath accuracy is worse than that of the rest of the swath. This behavior is a general characteristic of scanning pencil beam scatterometers. For SeaWinds, the accuracy of the rest of the swath, and the size of the swath are such that the instrument meets its science requirements despite mid-swath shortcomings. However, by understanding the problem at mid-swath, we can improve the performance there as well, yielding even better coverage and accuracy than was originally intended. The mid-swath performance degradation is due to suboptimal viewing geometry. In particular mid-swath measurements contains measurements from two azimuths, roughly 180 degrees apart. With the standard wind retrieval technique, mid-swath root mean square (RMS) wind direction errors are approximately 30 degrees for low wind speeds (3 - 5.5 m/s) and 20 degrees for moderate to high wind speeds (5.5 - 30 m/s). We discuss the underlying causes of this phenomenon in detail and propose a modification to the wind retrieval technique in order to improve mid-swath performance. By estimating the range of likely wind directions for each measurement cell, one can optimally apply information from neighboring cells in order to reduce random wind direction errors without significantly degrading the resolution of the resultant wind field. In this manner we are able to achieve mid-swath RMS wind direction errors as low as 15 degrees for low winds and 10 degrees for moderate to high winds, while at the same time preserving high resolution structures such as cyclones and fronts. Since our results are based on simulated data, we also outline a procedure for making use of real data to optimize the technique after launch.

Stiles, Bryan↗

Learnability of Red-Green Opponency

Lennie, Haake, and Williams found that in the lateral geniculate nucleus (LGN), parvocellular unit responses are consistent with the hypothesis that their input connectivity is blind to the difference between middle-wavelength-sensitive (MWS) and long-wavelength-sensitive (LWS) cones. Most of their cells have a total MWS input weight opposite in sign and similar in magnitude to their total LWS input weight. If these weights are exactly balanced, the construction of a red-green opponent system from such units is simple: such units need only be aligned so the signs of their outputs agree. Ahumada and Mulligan described an associative learning process which can accomplish this alignment. If the units are not balanced (carry some luminance information), the strong overlap between the MWS and LWS spectral responses can cause units to agree more on the basis of luminance, and the associative process fails to produce red-green opponency. The learning theory requires that the LGN units be nearly balanced (more strongly encode chromaticity than luminance) and quantitatively expresses the requirement: the principal component of the LGN outputs must be in the red-green rather than the luminance direction. We show that the cone weights of the monkey LGN cells measured by Derrington, Krauskopf, and Lennie can satisfy this learnability criterion even if the MWS spectral response is close to the LWS spectral response, simulating anomalous trichromacy. The learnability theory provides a source of visual system variation for explaining why different anomalous trichromats may make the same average anomaloscope match (same pigments), but have either narrow (good opponent learning) or wide (poor learning) ranges of acceptable matches.

Ahumada, Albert J., Jr.↗

Phytochrome-mediated germination and early development in spores of Dryopteris filix-mas L.: phase-specific and non phase-specific inhibition by staurosporine

The alkaloid staurosporine, currently known as the most potent inhibitor of protein kinase C, PKC, was tested for its ability to inhibit phytochrome-mediated spore germination in Dryopteris filix-mas L., evaluated by the induction of chlorophyll synthesis. Approximately half-maximal inhibition was obtained at a concentration of 10(-5) M. This effect of staurosporine was phase-specific and was found during the same period in which the presence of extracellular calcium is necessary for realization of the light signal. Furthermore, the ability of staurosporine to prevent progression of a germinated spore into early gametophyte development, evaluated by the accumulation of chlorophyll, was examined. Again, staurosporine (10(-5) M) significantly diminished chlorophyll accumulation, determined quantitatively in vivo by single-cell measurements, in a non-phase specific way. The fact that the phase-specific inhibitory effect of staurosporine in preventing germination was coincident with the phase-specific requirement of Ca2+ suggests that both Ca2+ and staurosporine affect the same step in the signal-transduction chain. A phosphorylation event catalysed by PKC or any Ca2+ -dependent protein kinase is proposed as the target of staurosporine and Ca2+.

Non-NASA Center↗

Exploring PV on the Red Planet: Mars Array Technology Experiment and Dust Accumulation and Removal Technology

The environment on the surface of Mars is different in several critical ways from the orbital environment in which space solar arrays normally operate. Some important differences are: 1) Low intensity, low temperature operation; 2) Spectrum modified by atmospheric dust, varies with time; 3) Indirect sunlight; 4) Possibility of dust atoms at some times of year; 5) Deposited dust; 6) Wind; 7) Peroxide-rich reactive soil. We are developing two experiments to test operation of solar arrays on the surface of Mars, to be flown on the 2001 Surveyor Lander mission. The Mars Array Technology Experiment (MATE) will test the operation of several types of solar cells under Mars conditions, and determine the direct and scattered solar spectrum at the surface. The Dust Accumulation and Removal Technology (DART) experiment will monitor the amount of dust deposition on a target solar cell, measure the characteristics of the dust, and test the feasibility of dust removal.

Landis, Geoffrey A.↗

On-orbit Calibration of the Seawinds Scatterometer Antennas

Measurements of ocean, sea-ice and terrain geophysical parameters can be remotely sensed using an active microwave sensor known as the microwave scatterometer. Satellite scatterometers are spaceborne radars that measure the absolute backscattered power from the earth's surface; and from this measurement, the normalized radar cross-section (sigma(sup 0)) of that surface is determined. Scatterometers calculate sigma(sup 0) of a measurement cell by inverting the radar equation [1]: where: R is range to the cell center, P(sub t) is transmitted power, lambda is transmitted wavelength, L is total path loss, G(sub A) is peak antenna gain, A(sub c) is cell area, and c is a pre-computed factor due to the approximation of the radar equation for extended area targets.

Zec, Josko↗

Integrated Power and Attitude Control System Demonstrated With Flywheels G2 and D1

On September 14, 2004, NASA Glenn Research Center's Flywheel Development Team experimentally demonstrated a full-power, high-speed, two-flywheel system, simultaneously regulating a power bus and providing a commanded output torque. Operation- and power-mode transitions were demonstrated up to 2000 W in charge and 1100 W in discharge, while the output torque was simultaneously regulated between plus or minus 0.8 N-m. The G2 and D1 flywheels--magnetically levitated carbon-fiber wheels with permanent magnet motors--were used for the experiment. The units were mounted on an air bearing table in Glenn's High Energy Flywheel Facility. The operational speed range for these tests was between 20,000 and 60,000 rpm. The bus voltage was regulated at 125 V during charge and discharge, and charge-discharge and discharge-charge transitions were demonstrated by changing the amount of power that the power supply provided between 300 and 0 W. In a satellite system, this would be the equivalent of changing the amount of energy that the solar array provides to the spacecraft. In addition to regulating the bus voltage, we simultaneously controlled the net torque produced by the two flywheel modules. Both modules were mounted on an air table that was restrained by a load cell. The load cell measured the force on the table, and the torque produced by the two flywheels on the table could be calculated from that measurement. This method was used to measure the torque produced by the modules, yielding net torques from -0.8 to 0.8 N-m. This was the first Glenn demonstration of the Integrated Power and Attitude Control System (IPACS) at high power levels and speeds.

Jansen, Ralph H.↗

NASA Tech Briefs, June 2008

Topics covered include: Charge-Control Unit for Testing Lithium-Ion Cells; Measuring Positions of Objects Using Two or More Cameras; Lidar System for Airborne Measurement of Clouds and Aerosols; Radiation-Insensitive Inverse Majority Gates; Reduced-Order Kalman Filtering for Processing Relative Measurements; Spaceborne Processor Array; Instrumentation System Diagnoses a Thermocouple; Chromatic Modulator for a High-Resolution CCD or APS; Commercial Product Activation Using RFID; Cup Cylindrical Waveguide Antenna; Aerobraking Maneuver (ABM) Report Generator; ABM Drag_Pass Report Generator; Transformation of OODT CAS to Perform Larger Tasks; Visualization Component of Vehicle Health Decision Support System; Mars Reconnaissance Orbiter Uplink Analysis Tool; Problem Reporting System; G-Guidance Interface Design for Small Body Mission Simulation; DSN Scheduling Engine; Replacement Sequence of Events Generator; Force-Control Algorithm for Surface Sampling; Tool for Merging Proposals Into DSN Schedules; Micromachined Slits for Imaging Spectrometers; Fabricating Nanodots Using Lift-Off of a Nanopore Template; Making Complex Electrically Conductive Patterns on Cloth; Special Polymer/Carbon Composite Films for Detecting SO2; Nickel-Based Superalloy Resists Embrittlement by Hydrogen; Chemical Passivation of Li+-Conducting Solid Electrolytes; Organic/Inorganic Polymeric Composites for Heat-Transfer Reduction; Composite Cathodes for Dual-Rate Li-Ion Batteries; Improved Descent-Rate Limiting Mechanism; Alignment-Insensitive Lower-Cost Telescope Architecture; Micro-Resistojet for Small Satellites; Using Piezoelectric Devices to Transmit Power through Walls; Miniature Latching Valve; Apparatus for Sampling Surface Contamination; Novel Species of Non-Spore-Forming Bacteria; Chamber for Aerosol Deposition of Bioparticles; Hyperspectral Sun Photometer for Atmospheric Characterization and Vicarious Calibrations; Dynamic Stability and Gravitational Balancing of Multiple Extended Bodies; Simulation of Stochastic Processes by Coupled ODE-PDE; Cluster Inter-Spacecraft Communications; Genetic Algorithm Optimizes Q-LAW Control Parameters; Low-Impact Mating System for Docking Spacecraft; Non-Destructive Evaluation of Materials via Ultraviolet Spectroscopy; Gold-on-Polymer-Based Sensing Films for Detection of Organic and Inorganic Analytes in the Air; and Quantum-Inspired Maximizer.

Source record↗