Search NASA⌕ Search

SEARCH · Search NASA

Results for “clean water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Understanding the performance of a bisphosphonate Ru water oxidation catalyst

Water oxidation catalysts (WOCs) create electrons that allow generating H 2 from water and sunlight, a promising process for the production of clean energy. Here, the mechanism of water oxidation mediated by Ru(2,2'-bipyridine-6,6'-diphosphonato)(4-picoline) 2 has been studied computationally to comprehend the results obtained in the experiments performed by the Concepcion and Grotjahn groups. Our study was performed at pH = 8 and 1. At pH = 8, the phosphonates are fully deprotonated and the catalysis, which is shown to be more energetically costly than that of the dicarboxylato Ru catalyst counterpart, takes place through a mechanism that involves a bimolecular interaction between two metal-oxo units (I2M). At pH = 1, only one of the phosphonates of the catalyst can deprotonate. After testing all possible pathways and comparing with experimental data, we conclude that the catalysis proceeds neither through a water nucleophilic attack nor via I2M, but rather we hypothesize that the rate-determining step involves both the catalyst and the ceric ammonium nitrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2023 American Society for Mass Spectrometry (ASMS) 71st Annual Conference on Mass Spectrometry and Allied Topics

Title (20 words): The investigation of the mechanism for the water splitting by holmium oxide nitrate complex in gas-phase Introduction (120 words): The studies for hydrogen from water splitting is important for clean energy economy as molecular hydrogen is a potential energy carrier. Therefore, understanding the fundamental chemistry of water splitting is essential. The water splitting activated by [Ho(NO3)4]- was previously studied. The suggested mechanism was to first eliminate •NO2 from [Ho(NO3)4]- to make [HoO(NO3)3]-. Then, water was added to form [HoO(NO3)3(H2O)]-, followed by eliminating the •OH to form [HoOH(NO3)3]-. However, we proposed a new mechanism with the formation of [Ho(NO3)3]- prior to the water addition. Once water is added to this intermediate to make [Ho(NO3)3(H2O)]-, the •H is eliminated to form [HoOH(NO3)3]-. Here we have used a labeled experiments with 18-O nitrates. The results to support the new mechanism are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biofouling of filtration membranes in wastewater reuse: In situ visualization with confocal laser scanning microscopy

The filtration membranes utilized in advanced treatment of municipal wastewater are prone to biological fouling. Permeability loss and water recovery limitations due to fouling necessitate additional pretreatment and membrane cleaning, which raise the cost of water reuse. Better fouling mitigation calls for a deeper understanding of biofilm behavior on water reuse membranes. This study uses confocal microscopy to monitor biofouling under realistic conditions. To simulate water reuse, a miniature flow cell with microfiltration and ultrafiltration membranes was operated under typical filtration conditions using secondary effluent from California's East Bay Municipal Utility District. The growing biofilms were stained for extracellular polymeric substances and live and dead cells, and they were monitored in situ under filtration conditions with a confocal laser scanning microscope to produce 2-D and 3-D images. In situ image series revealed biofilm growth and removal processes including internal and external fouling, extracellular polymeric substance production, wrinkling, delamination, and film re-deposition. Additionally, changes in biofilm morphology between in situ and ex situ images highlighted limitations of ex situ imaging. Here, these results provide insight into the physical and biological mechanisms of biofouling in hopes of informing the development of improved techniques for biofouling mitigation.

ultrafiltration↗

Catalyst Layer Resistance and Utilization in PEM Electrolysis

Improving utilization, performance, and stability of low iridium (Ir)-loaded anodes is a key goal to enable widespread adoption of polymer electrolyte membrane water electrolysis (PEMWE) for clean hydrogen production. A potential limitation is high ionic or electronic resistance of the anode catalyst layer, which leads to poor catalyst utilization, increased voltage losses, and high local overpotentials that can accelerate degradation. While catalyst layer resistance is relatively well-understood in fuel cells and other porous electrode systems, characterization of these effects is not as well established in PEMWE research. Here we present in-situ methods for measuring catalyst layer resistance in electrolysis cells using a non-faradaic H 2 /H 2 O condition as well as methods for calculating the associated voltage losses. These methods are applied to anode catalyst layers based on IrO 2 nanoparticles as well as dispersed nano-structured thin film (NSTF) Ir catalysts. Trends with anode catalyst loading and interactions between the porous transport layer and catalyst layer are investigated for IrO 2 anodes. Post-mortem microscopic analysis of durability-tested anodes is also presented, showing uneven degradation of the catalyst layer caused by catalyst layer resistance.

08 HYDROGEN↗

Ru-CoO heterostructured nanoparticles supported on nitrogen and sulfur codoped graphene nanosheets as effective electrocatalysts for hydrogen evolution reaction in alkaline media

Production of clean hydrogen energy from water splitting is vital for the future fuel industry, and nanocomposites have emerged as effective catalysts for the hydrogen evolution reaction (HER). In this study, Ru-CoO@SNG nanocomposites are prepared by controlled pyrolysis where Ru-CoO heterostructured nanoparticles are supported on nitrogen and sulfur codoped graphene oxide nanosheets. With a large surface area, the obtained composites exhibit a remarkable electrocatalytic activity toward HER in 1.0M KOH with an overpotential of only -90mV to reach the current density of 10 mA cm -2 , in comparison to -60mV for commercial Pt/C benchmark, along with high stability. Mechanistically, codoping of sulfur and nitrogen facilitates the dispersion of the nanoparticles, and the formation of Ru-CoO heterostructures increases the active site density, reduces the electron-transfer kinetics and boosts the catalytic performance. Further, results from this study highlight the unique potential of structural engineering in enhancing the electrocatalytic performance of heterostructured nanocomposites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Interface Band Alignment in Epitaxial SrTiO 3 /GaAs Heterojunctions

Recent concerns surrounding climate change and the contribution of fossil fuels to greenhouse gas (GHG) emissions have sparked interest and advancements in renewable energy sources including wind, solar, and hydroelectricity. These energy sources, often referred to as “clean energy”, generate no operational onsite GHG emissions. They also offer the potential for clean hydrogen production through water electrolysis, presenting a viable solution to create an environmentally friendly alternative energy carrier with the potential to decarbonize industrial processes reliant on hydrogen. To conduct a full life cycle analysis, it is crucial to account for the embodied emissions associated with renewable and nuclear power generation plants as they can significantly impact the GHG emissions linked to hydrogen production and its derived products. In this work, we conducted a comprehensive analysis of the embodied emissions associated with solar photovoltaic (PV), wind, hydro, and nuclear electricity. We investigated the implications of including plant-embodied emissions in the overall emission estimates of electrolysis hydrogen production and subsequently on the production of synthetic ammonia, methanol, and Fischer– Tropsch (FT) fuels. Results show that average embodied GHG emissions of solar PV, wind, hydro, and nuclear electricity generation in the United States (U.S.) were estimated to be 37, 9.8, 7.2, and 0.3 g CO 2 e/kWh, respectively. Life cycle GHG emissions of electrolytic hydrogen produced from solar PV, wind, and hydroelectricity were estimated as 2.1, 0.6, and 0.4 kg of CO 2 e/kg of H 2 , respectively, in contrast to the zero-emissions often used when the embodied emissions in their construction were excluded. Average life cycle emission estimates (CO 2 e/kg) of synthetic ammonia, methanol, and FT-fuel from solar PV electricity are increased by 5.5, 16, and 49 times, respectively, compared to the case when embodied emissions are excluded. This change also depends on the local irradiance for solar power, which can result in a further increase of GHG emissions by 35–41% in areas of low irradiance or reduce GHG emissions by 21–25% in areas with higher irradiance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stem psychrometer and flux data from US-CdM

Cleaned midday and predawn water potential data from 14 stem psychrometers installed within the footprint of the US-CdM flux tower, from May-October 2021. These data were collected in order to link environmental drivers, vegetation responses to seasonal water stress, and ecosystem fluxes of carbon and water at a pinyon-juniper woodland in southeastern Utah.Data include a comma separated values file containing all water potential data used in the published paper. Data were first published in Kannenberg et al. 2023 Agricultural and Forest Meteorology (doi: 10.1016/j.agrformet.2022.109269). Flux data are publicly available from the AmeriFlux portal (doi: 10.17190/AMF/1865477). This data file and the AmeriFlux data are all that is necessary to replicate the analyses in Kannenberg et al. 2023 Agricultural and Forest Meteorology.

54 ENVIRONMENTAL SCIENCES↗

Corrosion of 316H Stainless Steel in Flowing FLiBe (LiF-BeF 2 )

This milestone was originally envisioned for completion in FY21 and was delayed due to the COVID-19 response and difficulties in fabricating/obtaining fluoride salts. A monometallic type 316H stainless steel thermal convection loop (TCL) was operated for 1000 h with flowing LiFBeF 2 (i.e. FLiBe) salt and a peak temperature of 650°C. In general, the attack was minimal. However, classic mass transfer was not clearly observed with mass losses in both the hot and cold legs. There was an issue with cleaning the loop with water and specimens may have oxidized, which was not an issue with the previous FLiNaK TCL.

36 MATERIALS SCIENCE↗

VA EDH Data Curation Documentation (FY24-Q1)

The U.S. Department of Veterans Affairs (VA) places the health and well-being of our nation’s veterans as its top priority. VA is dedicated to offering timely access to high-quality, evidence-based mental health care that meets the needs of veterans and supports their reintegration into society. One of our core missions is to prevent suicide among veterans through innovative approaches and resources. Health outcomes, including suicide, are typically influenced by both genetics and environmental factors, such as air quality, transportation access, food availability, homelessness, and more. Mental health outcomes are associated with various stressors across socioeconomic, economic, and physical environments. Analyzing the connections between these stressors, covariates, and health outcomes relies on standardized data, which can be integrated into models like the VA’s Recovery Engagement and Coordination for Health, Veterans Enhanced Treatment (REACH VET). The World Health Organization (WHO) defines Environmental Determinants of Health (EDH) as factors like clean air, stable climate, water and sanitation, chemical safety, radiation protection, safe workplaces, sustainable agriculture, healthy urban environments, and nature preservation, all of which are crucial for good health.

54 ENVIRONMENTAL SCIENCES↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

VA EDH Data Curation Documentation (FY24-Q2)

The U.S. Department of Veterans Affairs (VA) places the health and well-being of our nation’s veterans as its top priority. VA is dedicated to offering timely access to high-quality, evidence-based mental health care that meets the needs of veterans and supports their reintegration into society. One of our core missions is to prevent suicide among veterans through innovative approaches and resources. Health outcomes, including suicide, are typically influenced by both genetics and environmental factors, such as air quality, transportation access, food availability, homelessness, and more. Mental health outcomes are associated with various stressors across socioeconomic, economic, and physical environments. Analyzing the connections between these stressors, covariates, and health outcomes relies on standardized data, which can be integrated into models like the VA’s Recovery Engagement and Coordination for Health, Veterans Enhanced Treatment (REACH VET). The World Health Organization (WHO) defines Environmental Determinants of Health (EDH) as factors like clean air, stable climate, water and sanitation, chemical safety, radiation protection, safe workplaces, sustainable agriculture, healthy urban environments, and nature preservation, all of which are crucial for good health.

99 GENERAL AND MISCELLANEOUS↗

VA EDH Data Curation Documentation (FY24-Q3)

The U.S. Department of Veterans Affairs (VA) places the health and well-being of our nation’s veterans as its top priority. VA is dedicated to offering timely access to high-quality, evidence-based mental health care that meets the needs of veterans and supports their reintegration into society. One of our core missions is to prevent suicide among veterans through innovative approaches and resources. Health outcomes, including suicide, are typically influenced by both genetics and environmental factors, such as air quality, transportation access, food availability, homelessness, and more. Mental health outcomes are associated with various stressors across socioeconomic, economic, and physical environments. Analyzing the connections between these stressors, covariates, and health outcomes relies on standardized data, which can be integrated into models like the VA’s Recovery Engagement and Coordination for Health, Veterans Enhanced Treatment (REACH VET). The World Health Organization (WHO) defines Environmental Determinants of Health (EDH) as factors like clean air, stable climate, water and sanitation, chemical safety, radiation protection, safe workplaces, sustainable agriculture, healthy urban environments, and nature preservation, all of which are crucial for good health.

54 ENVIRONMENTAL SCIENCES↗

VA EDH Data Curation Documentation FY24-Q4

The U.S. Department of Veterans Affairs (VA) places the health and well-being of our nation’s veterans as its top priority. VA is dedicated to offering timely access to high-quality, evidence-based mental health care that meets the needs of veterans and supports their reintegration into society. One of our core missions is to prevent suicide among veterans through innovative approaches and resources. Health outcomes, including suicide, are typically influenced by both genetics and environmental factors, such as air quality, transportation access, food availability, homelessness, and more. Mental health outcomes are associated with various stressors across socioeconomic, economic, and physical environments. Analyzing the connections between these stressors, covariates, and health outcomes relies on standardized data, which can be integrated into models like the VA’s Recovery Engagement and Coordination for Health, Veterans Enhanced Treatment (REACH VET). The World Health Organization (WHO) defines Environmental Determinants of Health (EDH) as factors like clean air, stable climate, water and sanitation, chemical safety, radiation protection, safe workplaces, sustainable agriculture, healthy urban environments, and nature preservation, all of which are crucial for good health.

99 GENERAL AND MISCELLANEOUS↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Innovative Accident Tolerant Fuel Materials May Help Extending the Life of Light Water Reactors: A Perspective

One of the main sources of clean electricity in the civilian power grid comes from light water reactors (LWRs). Some of these LWRs are being decommissioned prematurely because they may not be economically sustainable. It is proposed that the use of accident-tolerant fuel concepts may enable for LWR plant operation extension by making them safer and more economically competitive to operate. For example, the use of iron-chromium-aluminum (FeCrAl) alloys for the cladding of the fuel would not only reduce the risk of catastrophic reaction between the cladding and its environment in the case of a loss of coolant accident situation but also, for example, allow for higher fuel burnup during normal plant operation.

Materials Science↗