Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Potential Pitfalls Related to Space-Based Lidar Remote Sensing of the Earth with an Emphasis on Wind Measurement

A collection of issues is discussed that are potential pitfalls, if handled incorrectly, for earth-orbiting lidar remote sensing instruments. These issues arise due to the long target ranges, high lidar-to-target relative velocities, low signal levels, use of laser scanners, and other unique aspects of using lasers in earth orbit. Consequences of misunderstanding these topics range from minor inconvenience to improper calibration to total failure. We will focus on wind measurement using coherent detection Doppler lidar, but many of the potential pitfalls apply also to noncoherent lidar wind measurement, and to measurement of parameters other than wind. Each area will be identified as to its applicability.

Kavaya, Michael J.↗

Potential Pitfalls Related to Space-Based Lidar Remote Sensing of the Earth With an Emphasis on Wind Measurement

A collection of issues is discussed that are potential pitfalls, if handled incorrectly, for earth-orbiting lidar remote sensing instruments. These issues arise due to the long target ranges, high lidar-to-target relative velocities, low signal levels, use of laser scanners, and other unique aspects of using lasers in earth orbit. Consequences of misunderstanding these topics range from minor inconvenience to improper calibration to total failure. We will focus on wind measurement using coherent detection Doppler lidar, but many of the potential pitfalls apply also to noncoherent lidar wind measurement, and to measurement of parameters other than wind.

Kavaya, Michael J.↗

Real Time In Situ Observations of Equiaxed Dendrite Coherency in Al-Cu Alloys Using High-Brilliance, 3rd Generation Synchrotron Sources

In the last decade synchrotron X-ray sources have fast become the tool of choice for performing in-situ high resolution imaging during alloy solidification. This paper presents the results of an experimental campaign carried out at the European Synchrotron Radiation Facility, using a Bridgman furnace, to monitor phenomena during solidification of Al-Cu alloys - specifically the onset of equiaxed dendrite coherency. Conventional experimental methods for determining coherency involve measuring the change in viscosity or measuring the change in thermal conductivity across the solidifying melt Conflicts arise when comparing the results of these experimental techniques to find a relationship between cooling rate and coherency fraction. It has been shown that the ratio of average velocity to the average grain diameter has an inversely proportional relationship to coherency fraction. In-situ observation therefore makes it possible to measure these values directly from acquired images sequences and make comparisons with published results.

Murphy, Andrew G.↗

Elliptic jets, part 2. Dynamics of coherent structures: Pairing

The dynamics of the jet column mode of vortex pairing in the near field of an elliptic jet was investigated. Hot-wire measurements and flow visualization were used to examine the details of the pairing mechanism of nonplanar vortical elliptic structures and its effect on such turbulence measures as coherent velocities, incoherent turbulence intensities, incoherent and coherent Reynolds, stresses, turbulence production, and mass entrainment. It was found that pairing of elliptic vortices in the jet column does not occur uniformly around the entire perimeter, unlike in a circular jet. Merger occurs only in the initial major-axis plane. In the initial minor-axis plane, the trailing vortex rushes through the leading vortex without pairing and then breaks down violently, producing considerably greater entrainment and mixing than in circular or plane jets.

Husain, Hyder S.↗

Elliptic jets. II - Dynamics of coherent structures: Pairing

The dynamics of the jet column mode of vortex pairing in the near field of an elliptic jet was investigated. Hot-wire measurements and flow visualization were used to examine the details of the pairing mechanism of nonplanar vortical elliptic structures and its effect on such turbulence measures as coherent velocities, incoherent turbulence intensities, incoherent and coherent Reynolds, stresses, turbulence production, and mass entrainment. It was found that pairing of elliptic vortices in the jet column does not occur uniformly around the entire perimeter, unlike in a circular jet. Merger occurs only in the initial major-axis plane. In the inital minor-axis plane, the trailing vortex rushes through the leading vortex without pairing and then breaks down violently, producing considerably greater entrainment and mixing than in circular or plane jets.

Husain, Hyder S.↗

Determining the coherence of micropulses

A technique based on analysis of the cross spectra of single-use data from pulsars is described which can be used to measure the coherence properties of, and search for coherent periodicities in, pulsar signals. Several simulated pulsar models are constructed and analyzed to test the technique. From an analysis of 2000 consecutive pulses from PSR 2016 + 28 it is concluded that the micropulse coherence time of 430 MHz is less than the spin period for this object. This could could be consistent with a coherent model if the random phase jitter in such a model is 35 percent or more of the micropulse quasi-periodicity. The subpulse separation of roughly 10 ms is coherent across 4-5 pulse periods and is reasonably consistent with a model of subpulse drift that allows for variation about some mean drift rate. A two-component shot-noise model can reproduce much of the structure seen in the individual pulses as well as the spectra of PSR 2016 + 28.

Strohmayer, T. E.↗

Coherent Lidar Design and Performance Verification

This final report summarizes the investigative results from the 3 complete years of funding and corresponding publications are listed. The first year saw the verification of beam alignment for coherent Doppler lidar in space by using the surface return. The second year saw the analysis and computerized simulation of using heterodyne efficiency as an absolute measure of performance of coherent Doppler lidar. A new method was proposed to determine the estimation error for Doppler lidar wind measurements without the need for an independent wind measurement. Coherent Doppler lidar signal covariance, including wind shear and turbulence, was derived and calculated for typical atmospheric conditions. The effects of wind turbulence defined by Kolmogorov spatial statistics were investigated theoretically and with simulations. The third year saw the performance of coherent Doppler lidar in the weak signal regime determined by computer simulations using the best velocity estimators. Improved algorithms for extracting the performance of velocity estimators with wind turbulence included were also produced.

Frehlich, Rod↗

Spectral analysis, digital integration, and measurement of low backscatter in coherent laser radar

A method of surface acoustic wave (SAW) spectral analysis and digital integration that has been used previously in coherent CW laser work with CO2 lasers at 10.6 microns is described. Expressions are derived for the signal to noise ratio in the measured voltage spectrum with an approximation for the general case and rigorous treatment for the low signal case. The atmospheric backscatter data accumulated by the airborne LATAS (laser true airspeed) coherent laser radar system are analyzed.

Vaughan, J. M.↗

Airborne Doppler lidar measurements

This paper describes recent measurements using coherent Doppler lidars operating at a wavelength of 10.6 microns aboard the NASA Ames Convair 990. The purpose of the measurements was to obtain data on the atmospheric wind fields and the distribution of the backscatter coefficient at 10.6 microns. A decription of the instruments is provided detailing the modifications incorporated following the 1981 test flights of the systems. The measurement program is outlined, and preliminary results are discussed.

Bilbro, James W.↗

On the theory of quantum measurement

Many so called paradoxes of quantum mechanics are clarified when the measurement equipment is treated as a quantized system. Every measurement involves nonlinear processes. Self consistent formulations of nonlinear quantum optics are relatively simple. Hence optical measurements, such as the quantum nondemolition (QND) measurement of photon number, are particularly well suited for such a treatment. It shows that the so called 'collapse of the wave function' is not needed for the interpretation of the measurement process. Coherence of the density matrix of the signal is progressively reduced with increasing accuracy of the photon number determination. If the QND measurement is incorporated into the double slit experiment, the contrast ratio of the fringes is found to decrease with increasing information on the photon number in one of the two paths.

Haus, Hermann A.↗

Analysis and measurement of electromagnetic scattering by pyramidal and wedge absorbers

By modifying the reflection coefficients in the Uniform Geometrical Theory of Diffraction a solution that approximates the scattering from a dielectric wedge is found. This solution agrees closely with the exact solution of Rawlins which is only valid for a few minor cases. This modification is then applied to the corner diffraction coefficient and combined with an equivalent current and geometrical optics solutions to model scattering from pyramid and wedge absorbers. Measured results from 12 inch pyramid absorbers from 2 to 18 GHz are compared to calculations assuming the returns add incoherently and assuming the returns add coherently. The measured results tend to be between the two curves. Measured results from the 8 inch wedge absorber are also compared to calculations with the return being dominated by the wedge diffraction. The procedures for measuring and specifying absorber performance are discussed and calibration equations are derived to calculate a reflection coefficient or a reflectivity using a reference sphere. Shaping changes to the present absorber designs are introduced to improve performance based on both high and low frequency analysis. Some prototypes were built and tested.

Dewitt, B. T.↗

Coherent anti-Stokes Raman spectroscopy temperature measurements in a hydrogen-fueled supersonic combustor

Coherent anti-Stokes Raman spectroscopy (CARS) thermometry has been used to obtain static temperature cross sections in a three-dimensional supersonic combustor flowfield. Data were obtained in three spanwise planes downstream of a single normal fuel injector which was located downstream of a rearward-facing step. The freestream flow was nominally Mach 2 and was combustion heated to a total temperature of 1440 K (yielding a static temperature of about 800 K in the freestream) to simulate the inflow to a combustor operating at a flight Mach number of about 5.4. Since a broadband probe laser was used an instantaneous temperature sample was obtained with each laser shot at a repetition rate of 10 Hz. Thus root-mean-square (rms) temperatures and temperature probability density functions (pdf's) were obtained in addition to mean temperatures.

Smith, Michael W.↗

Multibaseline TanDEM-X Mangrove Height Estimation: The Selection of the Vertical Wavenumber

We generated a large-scale mangrove forest height map using multiple TanDEM-X (TDX) interferometric synthetic aperture radar (InSAR) acquisitions with various spatial baselines in order to improve the height estimation accuracy across a wide range of forest heights. The forest height inversion using InSAR data is strongly dependent upon the vertical wavenumber (i.e., perpendicular baseline). First, we investigated the role of the vertical wavenumber in forest height inversion from InSAR data using the sensitivity of the interferometric (volume) coherence to forest height. We used corrected but lower resolution and accuracy Shuttle Radar Topography Mission (SRTM) mangrove height maps as a priori information over Akanda and Pongara National Parks in Gabon to estimate lower and upper boundaries of the vertical wavenumber over test sites from the measured coherence-to-height sensitivity. Only TDX acquisitions within the boundaries of the vertical wavenumber were selected and combined for multibaseline mangrove height inversion. Mangrove forest height was obtained with multibaseline TDX acquisitions and was validated against the reference height derived from field measurement data providing improvements in multibaseline inversion over existing height estimates (i.e., SRTM height) and single-baseline inversions (multibaseline inversion: r(exp 2) = 0.98, root mean square error (RMSE) of 2.73 m; SRTM height: r(exp 2) = 0.86, RMSE = 7.21 m; single-baseline inversions: r(exp 2) = 0.08-0.97, RMSE = 3.86-11.10 m). As a result, to accurately estimate forest heights over a wide range (3-60 m), multibaseline InSAR acquisitions (at least three different baselines) are needed to exclude biases associated with the vertical wavenumber in forest height inversion.

vertical wavenumber.↗

Tunable Single-Frequency Near IR Lasers for DIAL Applications

Tunable single-frequency sources in the 2-4 micron wavelength region are useful for remote DIAL measurements of chemicals and pollutants. We are developing tunable single-frequency transmitters and receivers for both direct and coherent detection lidar measurement applications. We have demonstrated a direct-diode-pumped PPLN-based OPO that operates single frequency, produces greater than 10 mW cw and is tunable over the 2.5 - 3.9 micron wavelength region. This laser has been used to injection seed a pulsed PPLN OPO, pumped by a 1.064 micron Nd:YAG laser, producing 50-100 microJoule single-frequency pulses at 100 Hz PRF near 3.6 micron wavelength. In addition, we have demonstrated a cw Cr:ZnSe laser that is tunable over the 2.1 - 2.8 micron wavelength region. This laser is pumped by a cw diode-pumped Tm:YALO laser and has produced over 1.8 W cw. Tm- and Tm, Ho-doped single-frequency solid-state lasers that produce over 50 mW cw and are tunable over approximately 10 nm in the 2 -2.1 micron band with fast PZT tuning have also been demonstrated. A fast PZT-tunable Tm, Ho:YLF laser was used for a direct-detection column content DIAL measurement of atmospheric CO2. Modeling shows that that all these cw and pulsed sources are useful for column-content coherent DIAL measurements at several km range using topographic targets.

Henderson, Sammy W.↗

Prospects of Measuring Atmospheric Winds with a 2-Micron Coherent Doppler Lidar from the International Space Station

The measurement of global winds in the troposphere is often cited as the most important single missing element of our present weather and climate observing system. The most promising technique for filling this gap is with space-based coherent Doppler lidar. A Space Shuttle mission (SPAce Readiness Coherent Lidar Experiment, SPARCLE) is being developed at NASA/MSFC (Huntsville, AL) that will provide the first space-based test of the technique, validating the ability to maintain the severe requirements on optical alignments during launch and space operations, and removing the Doppler shift of the spacecraft velocity and Earth's rotation. Continued development will include a scientific research mission in the mid-2000's, and an operational instrument around 2010. It is anticipated that the International Space Station will be a good candidate as a platform for the scientific research mission (as an attached payload). The need for and value of wind observations, the status and objectives of the SPARCLE mission, and detailed plans for the follow-on missions, including technology development, will be discussed.

Miller, Timothy L.↗

Sound Sources Identified in High-Speed Jets by Correlating Flow Density Fluctuations With Far-Field Noise

Noise sources in high-speed jets were identified by directly correlating flow density fluctuation (cause) to far-field sound pressure fluctuation (effect). The experimental study was performed in a nozzle facility at the NASA Glenn Research Center in support of NASA s initiative to reduce the noise emitted by commercial airplanes. Previous efforts to use this correlation method have failed because the tools for measuring jet turbulence were intrusive. In the present experiment, a molecular Rayleigh-scattering technique was used that depended on laser light scattering by gas molecules in air. The technique allowed accurate measurement of air density fluctuations from different points in the plume. The study was conducted in shock-free, unheated jets of Mach numbers 0.95, 1.4, and 1.8. The turbulent motion, as evident from density fluctuation spectra was remarkably similar in all three jets, whereas the noise sources were significantly different. The correlation study was conducted by keeping a microphone at a fixed location (at the peak noise emission angle of 30 to the jet axis and 50 nozzle diameters away) while moving the laser probe volume from point to point in the flow. The following figure shows maps of the nondimensional coherence value measured at different Strouhal frequencies ([frequency diameter]/jet speed) in the supersonic Mach 1.8 and subsonic Mach 0.95 jets. The higher the coherence, the stronger the source was.

Panda, Jayanta↗

A comparison between using incoherent or coherent sources to align and test an adaptive optical telescope

The concept in the initial alignment of the segmented mirror adaptive optics telescope called the phased array mirror extendable large aperture telescope (Pamela) is to produce an optical transfer function (OTF) which closely approximates the diffraction limited value which would correspond to a system pupil function that is unity over the aperture and zero outside. There are differences in the theory of intensity measurements between coherent and incoherent radiation. As a result, some of the classical quantities which describe the performance of an optical system for incoherent radiation can not be defined for a coherent field. The most important quantity describing the quality of an optical system is the OTF and for a coherent source the OTF is not defined. Instead a coherent transfer function (CTF) is defined. The main conclusion of the paper is that an incoherent collimated source and not a collimated laser source is preferred to calibrate the Hartmann wavefront sensor (WFS) of an aligned adaptive optical system. A distant laser source can be used with minimum problems to correct the system for atmospheric turbulence. The collimation of the HeNe laser alignment source can be improved by using a very small pin hole in the spatial filter so only the central portion of the beam is transmitted and the beam from the filter is nearly constant in amplitude. The size of this pin hole will be limited by the sensitivity of the lateral effect diode (LEDD) elements.

Anderson, Richard↗