Nasa’s Cold Atom Lab Turns 3 Years Cold: Ongoing Studies of Quantum Gases and Atom-Wave Interferometry in Low-Earth Orbit
No abstract provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract provided
Explore the source record for details and available documents.
Switchgrass low-land ecotypes have significantly higher biomass but lower cold tolerance compared to up-land ecotypes. Understanding the molecular mechanisms underlying cold response, including the ones at transcriptional level, can contribute to improving tolerance of high-yield switchgrass under chilling and freezing environmental conditions. Here, by analyzing an existing switchgrass transcriptome dataset, the temporal cis- regulatory basis of switchgrass transcriptional response to cold is dissected computationally. We found that the number of cold-responsive genes and enriched Gene Ontology terms increased as duration of cold treatment increased from 30 min to 24 hours, suggesting an amplified response/cascading effect in cold-responsive gene expression. To identify genomic sequences likely important for regulating cold response, machine learning models predictive of cold response were established using k -mer sequences enriched in the genic and flanking regions of cold-responsive genes but not non-responsive genes. These k -mers, referred to as putative cis -regulatory elements (pCREs) are likely regulatory sequences of cold response in switchgrass. There are in total 655 pCREs where 54 are important in all cold treatment time points. Consistent with this, eight of 35 known cold-responsive CREs were similar to top-ranked pCREs in the models and only these eight were important for predicting temporal cold response. More importantly, most of the top-ranked pCREs were novel sequences in cold regulation. Our findings suggest additional sequence elements important for cold-responsive regulation previously not known that warrant further studies.
Abstract The mechanisms by which sensible heat fluxes (SHFs) alter cold pool characteristics and dissipation rates are investigated in this study using idealized two‐dimensional numerical simulations and an environment representative of daytime, dry, continental conditions. Simulations are performed with no SHFs, SHFs calculated using a bulk formula, and constant SHFs for model resolutions with horizontal (vertical) grid spacings ranging from 50 m (25 m) to 400 m (200 m). In the highest resolution simulations, turbulent entrainment of environmental air into the cold pool is an important mechanism for dissipation in the absence of SHFs. Including SHFs enhances cold pool dissipation rates, but the processes responsible for the enhanced dissipation differ depending on the SHF formulation. The bulk SHFs increase the near‐surface cold pool temperatures, but their effects on the overall cold pool characteristics are small, while the constant SHFs influence the near‐surface environmental stability and the turbulent entrainment rates into the cold pool. The changes to the entrainment rates are found to be the most significant of the SHF effects on cold pool dissipation. SHFs may also influence the timing of cold pool‐induced convective initiation by altering the environmental stability and the cold pool intensity. As the model resolution is coarsened, cold pool dissipation is found to be less sensitive to SHFs. Furthermore, the coarser resolution simulations not only poorly but sometimes wrongly represent the SHF impacts on the cold pools. Recommendations are made regarding simulating the interaction of cold pools with convection and the land surface in cloud‐resolving models.
Abstract Cold pools produced by convective storms play an important role in Earth's climate system. However, a common framework does not exist for objectively identifying convective cold pools in observations and models. The present study investigates convective cold pools within a simulation of tropical continental convection that uses a cloud‐resolving model with a coupled land‐surface model. Multiple variables are assessed for their potential in identifying convective cold pool boundaries, and a novel technique is developed and tested for identifying and tracking cold pools in numerical model simulations. This algorithm is based on surface rainfall rates and radial gradients in the density potential temperature field. The algorithm successfully identifies near‐surface cold pool boundaries and is able to distinguish between connected cold pools. Once cold pools have been identified and tracked, composites of cold pool evolution are then constructed, and average cold pool properties are investigated. Wet patches are found to develop within the centers of cold pools where the ground has been soaked with rainwater. These wet patches help to maintain cool surface temperatures and reduce cold pool dissipation, which has implications for the development of subsequent convection.
This paper describes a technology review of non-destructive examination (NDE) methods that can be applied to cold spray coatings. Cold spray is a process for depositing metal powder at high velocity so that it bonds to the substrate metal without significant heating that would be likely to cause additional residual tensile stresses. Coatings in the range from millimeters to centimeters are possible at relatively high deposition rates. Cold spray coatings that may be used for hydroelectric components that are subject to erosion, corrosion, wear, and cavitation damage are of interest. The topic of cold spray NDE is treated generally however and may be considered applicable to virtually any cold spray application except where there are constraints of the hydroelectric component application that bear special consideration. Hydroelectric turbine components are primarily made from low carbon and austenitic stainless steels. They are typically very large components that are partially assembled on-site. Transport of these components within the hydroelectric facility and away from the hydroelectric facility is challenging due to the component’s size and weight, high cost of disassembly, and the confined space of the dam. One method for prolonging component life is application of cold spray and thermal powder metal coatings to the components most susceptible to erosion, corrosion, cracking, and mechanical wear. Process controls and visual inspections have historically been applied to cold spray application; however, quantitative NDE could detect anomalies not readily apparent from such a visual examination. Optical profilometry, Eddy current, ultrasound, and hardness tests are shown for one set of good, fair, and poor Nickle-Chrome (NiCr) on 304 stainless steel (304SS) cold spray samples to demonstrate inspection possibilities. The primary indicator of cold spray quality is the cold spray porosity that is most directly measured with witness-sample destructive examinations (DE) – mostly photo-micrographs. These DE generated porosity values are correlated with optical profilometry, eddy current, ultrasound, and hardness test NDE methods to infer the porosity and other Information of interest. These parameters of interest primarily include: • Porosity primarily caused by improper process conditions (temperature, gas velocity, spray standoff, spray angle, powder size, condition, surface cleanliness, surface oxide, etc.). • Presence/absence of the cold spray coating including possible over-sprayed voids • Coating thickness Optical profilometry measurements of surface roughness trended with porosity plus if compared with a reference measurement or reference drawing would provide information on the coating thickness. Ultrasound could provide similar surface profile information plus attenuation measurements trended with porosity. The ultrasound measurements however may be limited to geometries where the substrate back-wall is normal to the cold spray surface and not too thick. Eddy current showed a strong correlation with porosity. Eddy currents can also be sensitive to cracks and do not need fluid coupling to make measurements. Eddy currents however are not sensitive to coating thicknesses in most cases. Vickers hardness measurements also tracked well with porosity. These types of hardness measurements however are also not sensitive to coating thickness. An NDE program may include multiple measurements. Acknowledgement: This work is sponsored by Bonneville Power Administration (BPA) under their technology innovation project program. Such support does not constitute BPA endorsement of views expressed in this work.
High level waste melter feed is converted into glass in a joule heated melter, where it forms a floating layer of reacting feed, called the cold cap. After the glass-forming phase becomes connected, evolving gases produce bubbles that form a foam layer under the cold cap. The bubbles coalesce into cavities that escape around the edges of the cold cap. The foam layer insulates the cold cap from the heat transferred from the molten glass below. More information is needed about the formation and behavior of the foam layer to control, limit and possibly avoid foaming, thus allowing for a higher rate of melting. The cold cap behavior was investigated in a laboratory scale assembly with a sealed silica-glass crucible. A high alumina waste simulant was fed into the crucible and the feed charging rate was varied from 3 to 7 mL min-1. After a fixed amount of time (35 min), feed charging was stopped and the crucible was removed from the furnace and quenched on a copper block to preserve the structure of the cold cap and foam during cooling. During the rapid quenching, thermal cracking of the glass and cold cap allowed it to be broken up into sections for analysis. The effect of the charging rate on the height, area and volume of the cold cap was determined. The size of the bubbles collected in the foam layer under the cold cap increased as the cold cap expanded. Under the cold cap, the bubbles coalesced into oblong cavities. These cavities allowed the evolved gases to escape around the edges of the cold cap through the molten glass into the melter plenum.
Under the sponsorship of the US Department of Energy National Nuclear Security Administration, staff members at the Oak Ridge National Laboratory have been conducting studies to determine whether the High Flux Isotope Reactor (HFIR) can be converted from high enriched uranium (HEU) fuel to low enriched uranium (LEU) fuel. As part of these ongoing studies, an assessment of the impact that the HEU to LEU fuel conversion has on the nuclear heat generation rates in regions of the HFIR cold source system and its moderator vessel was performed and is documented in this report. Silicon production rates in the cold source aluminum regions and few-group neutron fluxes in the cold source moderator were also estimated. Neutronics calculations were performed with the Monte Carlo N-Particle code to determine the nuclear heat generation rates in regions of the HFIR cold source and its vessel for the HEU core operating at a full reactor power (FP) of 85 MW(t) and the reference LEU core operating at an FP of 100 MW(t). Calculations were performed with beginning-of-cycle (BOC) and end-of-cycle (EOC) conditions to bound typical irradiation conditions. Average specific BOC heat generation rates of 12.76 and 12.92 W/g, respectively, were calculated for the hemispherical region of the cold source liquid hydrogen (LH2) for the HEU and LEU cores, and EOC heat generation rates of 13.25 and 12.86 W/g, respectively, were calculated for the HEU and LEU cores. Thus, the greatest heat generation rates were calculated for the EOC HEU core, and it is concluded that the conversion from HEU to LEU fuel and the resulting increase of FP from 85 MW to 100 MW will not impact the ability of the heat removal equipment to remove the heat deposited in the cold source system. Silicon production rates in the cold source aluminum regions are estimated to be about 12.0% greater at BOC and 2.7% greater at EOC for the LEU core in comparison to the HEU core. Silicon is aluminum s major transmutation product and affects mechanical properties of aluminum including density, neutron irradiation hardening, swelling, and loss of ductility. Because slightly greater quantities of silicon will be produced in the cold source moderator vessel for the LEU core, these effects will be slightly greater for the LEU core than for the HEU core. Three-group (thermal, epithermal, and fast) neutron flux results tallied in the cold source LH2 hemisphere show greater values for the LEU core under both BOC and EOC conditions. The thermal neutron flux in the LH2 hemisphere for the LEU core is about 12.4% greater at BOC and 2.7% greater at EOC than for the HEU core. Therefore, cold neutron scattering will not be adversely affected and the 4 12 neutrons conveyed to the cold neutron guide hall for research applications will be enhanced.
Highlights: • AtGLR1.2 and 1.3 positively enhance cold tolerance in Arabidopsis. • AtGLR1.2 and 1.3 promote jasmonate accumulation in response to cold stress. • AtGLR1.2 and 1.3 increase cold resistance by affecting the CBF/DREB1 pathway. • AtGLR1.2 and 1.3 drove similar functions without directly interacting. Plant glutamate-like receptors (GLRs), which are homologs of mammalian ionotropic glutamate receptors (iGluRs), are thought to be involved in plant growth, development, and environmental stress responses. In this study, we demonstrated that two members of Arabidopsis glutamate-like receptors, AtGLR1.2 and AtGLR1.3, play positive roles in the plant response to cold stress. Genetic and biochemical experiments revealed that exogenous jasmonate could attenuate the cold sensitivity of glr1.2 and glr1.3 mutants, and the overexpression of GLR1.2 or GLR1.3 enhanced cold tolerance by increasing endogenous jasmonate levels under cold stress. In addition, the expression of genes in the CBF/DREB1 signaling pathway was decreased in the glr1.2 and glr1.3 mutants, but was promoted in GLR1.2-OE and GLR1.3-OE transgenic plants compared with the wild-type during cold treatment. Further investigation revealed that AtGLR1.2 and AtGLR1.3 independently drove similar functions without directly interacting. Together, our findings suggest that AtGLR1.2 and 1.3 positively enhance cold tolerance in Arabidopsis by activating endogenous jasmonate accumulation and subsequently promoting the downstream CBF/DREB1 cold response pathway during cold stress.
The dynamic strain rate ahead of a crack tip formed during stress corrosion cracking (SCC) under a static load is assumed to arise from the crack propagation. The strain surrounding the crack tip would be redistributed as the crack grows, thereby having the effect of dynamic strain. Recently, several studies have shown cold work to cause accelerated crack growth rates during SCC, and the slip-dissolution mechanism has been widely applied to account for this via a supposedly increased crack-tip strain rate in cold worked material. While these interpretations consider cold work as a homogeneous effect, dislocations are generated inhomogeneously within the microstructure during cold work. The presence of grain boundaries results in dislocation pile-ups that cause local strain concentrations. The local strains generated from cold working α-brass by tensile elongation were characterized using electron backscatter diffraction (EBSD). The role of these local strains in SCC was studied by measuring the strain distributions from the same regions of the sample before cold work, after cold work, and after SCC. Though, the cracks did not always initiate or propagate along boundaries with pre-existing local strains from the applied cold work, the local strains surrounding the cracked boundaries had contributions from both the crack propagation and the prior cold work. - Highlights: • Plastic strain localization has a complex relationship with SCC susceptibility. • Surface relief created by cold work creates its own granular strain localization. • Cold work promotes crack growth but several other factors are involved.
Highlights: • Effect of strain on Texture formation is reported in HfZrTiTaNb for the first time. • Cold-rolled microstructure shows high density of deformation heterogeneities. • Weak texture compared to other BCC phases in HEAs • Imposed strain does not affect texture significantly unlike other BCC materials. - Abstract: The effect of cold-rolling strain on the evolution of deformation and grain growth textures in an equiatomic HfZrTiTaNb refractory high entropy alloy (RHEA) was investigated. For this purpose, the development of microstructure and texture was compared in 50% and 90% cold-rolled materials. The development of deformation microstructure was accompanied by the formation of extensive deformation heterogeneities. The 90% cold-rolled material showed ultrafine lamellar regions as well as regions severely fragmented by the fine scale deformation heterogeneities. The 50% cold-rolled material showed dominant ND-fiber (ND//), while the 90% cold-rolled material showed presence of both RD (RD//) and ND-fiber components. Profuse deformation heterogeneities presumably weakened the deformation texture considerably. The annealing texture of the 50% and 90% cold-rolled material showed stronger {111} component. Comparison of the annealing texture of the 50% and 90% cold-rolled materials with other BCC HEA phases indicated much weaker texture. The annealing texture of the RHEA was not significantly strengthened by increasing cold-rolling strain, presumably due to the high density of deformation heterogeneities in the cold-rolled microstructure. Thus, deformation heterogeneities significantly influenced the formation of cold-rolling and annealing textures of the equiatomic HfZrTiTaNb RHEA.
Highlights: • Sn microalloying contributes to the enhancement in cold rolling texture intensity and the acceleration in cold rolling texture transformation. • Sn microalloying promotes the recrystallization process, and recrystallization occurs preferentially in steel with Sn compared with Sn-free steel. • Sn microalloying inhibits the growth of recrystallized grains, and the finer grains are obtained in steel with Sn. - Abstract: We investigated the effects of Sn microalloying on cold rolling and recrystallization textures and microstructure of a ferritic stainless steel. The as-received hot rolled sheets were cold rolled at 10%–90% reductions; the sheets cold rolled up to an 80% reduction were annealed at 740–880 °C for 5 min. For comparison, the cold rolling and recrystallization textures of the steel sheets with and without Sn were determined with the conventional X-ray diffraction method. The cold rolling and recrystallization metallographic microstructures were measured by scanning electron microscope and optical microscope, and the crystal orientation maps of the cold rolled and annealed samples were observed by electron backscattered diffraction. The micro-hardness was determined using a digital micro-hardness tester. Our results show that Sn microalloying in a medium chromium ferritic stainless steel plays multiple roles in the cold rolling and recrystallization processes. Sn micrcoalloying contributes to the enhancement in cold rolling texture intensity and the acceleration in cold rolling texture transformation. Sn microalloying is beneficial in promoting the recrystallization process. Recrystallization occurs preferentially in the ferritic stainless steel with Sn. Sn microalloying plays an important role in inhibiting the growth of recrystallized grains. The finer grains are obtained in ferritic stainless steel with Sn when annealing at high temperatures.
An ensemble seasonal hindcast approach is used to investigate the development of the equatorial Pacific Ocean cold sea surface temperature (SST) bias and its characteristic annual cycle in the Community Earth System Model, version 1 (CESM1). In observations, eastern equatorial Pacific SSTs exhibit a warm phase during boreal spring and a cold phase during late boreal summer–autumn. The CESM1 climatology shows a cold bias during both warm and cold phases. In our hindcasts, the cold bias during the cold phase develops in less than 6 months, whereas the cold bias during the warm phase takes longer to emerge. The fast-developing cold-phase cold bias is associated with too-strong vertical advection and easterly wind stress over the eastern equatorial region. The antecedent boreal summer easterly wind anomalies also appear in atmosphere-only simulations, indicating that the errors are intrinsic to the atmosphere component. For the slower-developing warm-phase cold bias, we find that the too-cold SSTs over the equatorial region are associated with a slowly evolving upward displacement of subsurface ocean zonal currents and isotherms that can be traced to the ocean component.
Five improvements are reported in cold-plate fabrication. This cold plate is part of a thermal control system designed to serve on space missions. The first improvement is the merging of the end sheets of the cold plate with the face sheets of the structural honeycomb panel. The cold plate, which can be a brazed assembly, uses the honeycomb face sheet as its end sheet. Thus, when the honeycomb panel is fabricated, the face sheet that is used is already part of the cold plate. In addition to reducing weight, costs, and steps, the main benefit of this invention is that it creates a more structurally sound assembly. The second improvement involves incorporation of the header into the closure bar to pass the fluid to a lower layer. Conventional designs have used a separate header, which increases the geometry of the system. The improvement reduces the geometry, thus allowing the cold plate to fit into smaller area. The third improvement eliminates the need of hose, tube, or manifold to supply the cooling fluid externally. The external arrangement can be easily damaged and is vulnerable to leakage. The new arrangement incorporates an internal fluid transfer tube. This allows the fluid to pass from one cold plate to the other without any exposed external features. The fourth improvement eliminates separate fabrication of cold plate(s) and structural members followed by a process of attaching them to each other. Here, the structural member is made of material that can be brazed just as that of the cold plate. Now the structural member and the cold plate can be brazed at the same time, creating a monolithic unit, and thus a more structurally sound assembly. Finally, the fifth improvement is the elimination of an additional welding step that can damage the braze joints. A tube section, which is usually welded on after the braze process, is replaced with a more structurally sound configuration that can be brazed at the same time as the rest of the cold plate.
Abstract Convectively generated cold pools are important to the Earth system as they exert strong controls on deep convective-storm initiation, intensity, and life cycle. Despite their importance, efforts to introduce such cold pool controls into weather and climate models lack guidance and/or physical constraints from cold pool observations. This work presents a detailed, purely observational analysis of a cold pool event that took place on 23–24 May 2011 in north-central Oklahoma. The characteristics of the cold pool, and the spatiotemporal evolution of the hydrometeors and dynamics in the proximity of the cold pool, are studied with high-resolution observations. The unprecedented dataset used in this work to study cold pool characteristics includes an enhanced network of surface weather stations, a high-temporal-frequency sounding array, and the NEXRAD and Atmospheric Radiation Measurement (ARM) Southern Great Plains radar networks. The potential use of NEXRAD surveillance scans to estimate height and propagation speed of the leading edge of the cold pool (LECP) is presented in this work. Manual identification and tracking of the LECP from NEXRAD imagery shows a spatial and temporal heterogeneity of the LECP properties. Surprisingly, over its detected life cycle, the LECP speed remains almost constant, even though the strength of the cold pool diminishes in time and its height varies. Radar analysis shows that pulses of graupel and hail within downdrafts in the convective system generating the cold pool appeared to be related to temporary increases in the LECP height.
Cold neutrons have kinetic energies less than 5 meV and wavelengths greater than 4 Α. They can be transported over tens of meters through super-reflecting neutron guides with minimal losses. Cold neutrons are used to investigate the structure of larger molecular systems such as biological materials, polymers and aggregates, due to their preferential interaction with light elements and general ignorance towards heavy ones. Intense beams of cold neutrons are obtained from slowing down a source of thermal energy neutrons - which may be from either a research reactor or spallation neutron source - through some cryogenic moderator such as liquid hydrogen or deuterium. The present reactor at the NIST Center for Neutron Research (NCNR) - NBSR - is such a cold neutron source (CNS) facility which provides cold neutron beams for over 2,000 scientists performing various experiments annually. Feasibility studies on a replacement reactor for the NBSR are underway at NCNR with the primary purpose of optimized cold neutron production. Low enriched uranium (LEU) fuel is required for the new reactor to conform to nuclear non-proliferation agreements. The low thermal power rate of 20 MW is taken as a priority with a fuel cycle length designated as 30 days. A horizontal split compact core with a large D{sub 2}O reflector tank is currently proposed and studied, with the expectation of achieving much better cold neutron performance than the present NIST reactor (NBSR). A preliminary core design has been completed using MCNP6 modeling and simulation. The physics performance characteristics of the proposed new core indicate that the new design is competitive with the most notable existing advanced cold neutron sources. In previous studies, only rectangular shaped fuel elements were considered because they have similar external dimensions as the NBSR fuel elements. However, from a compact core standpoint, a square lattice is not the most effective geometry for a tight configuration. Moreover, the previous studies also showed that the square lattice of the fuel elements left little room to accommodate vertical insertion blade-type control elements. As a result, all control blades had to reside in the D{sub 2}O reflector, which made the design cumbersome (in that case the control blades must penetrate the reflector tank) and neutronically uneconomical. In this summary, a preliminary feasibility study on a hexagonal core lattice is performed to render an alternative geometry for the new reactor (HEX core) to provide sufficient space for the control elements. The identical LEU fuel (U{sub 3}Si{sub 2}/Al) with U-235 enrichment 19.75% is used in the new design. The maximum thermal power and fuel management scheme remain the same as the previous investigations (three 30-day cycled batches for each batch of three fuel elements). The horizontal split compact core concept is also applied in the hexagonal lattice core design, with the objective of creating maximum thermal flux traps between the split core halves. A detailed description of the model for the hexagonal lattice core is presented in the following section. The HEX core design achieves a number of successes over the previous split-core design. Given that much of the motivation of this work was based on implementation of control blades into a concept which lacked them, it is notable that neutron economy was well-preserved in the process of achieving conservatively effective reactivity control; start-up k{sub eff} was in fact increased by 0.23% and peak thermal flux increased by ∼25%. A useful metric in determining the efficacy of resources towards creating an environment for the production of cold neutrons - dubbed the 'quality factor' (QF) - is the ratio of peak thermal neutron flux in a system to the total thermal power produced. Because HEX core's objectives are very focused in comparison to existing research reactors, it is fitting to pursue a design which out-performs all others in terms of some specific performance metric, namely this QF term. While HFIR remains the greatest cold neutron source in the world, it does so through use of HEU fuel (which will be replaced with LEU in the near future), and suffers a greater level of fast neutron contamination that is expected from the HEX design. The new core design achieves these successes due to the hexagonal lattice fuel arrangement, a 13.5% reduction in cladding mass, and a 13.1% reduction in fuel element volume. In spite of a 5.5% reduction in fuel mass, no compromises in reactor performance were noted. Provided the favorable characteristics shown of the control blade design, refueling intervals longer than the prescribed 30 days may be considered. It can be speculated that with these quantitative benefits, the overall capital and continuous costs of the HEX core design will be less than the previously proposed split-core concept.
Using high-resolution 3D and 2D (axisymmetric) hydrodynamic simulations in spherical geometry, we study the evolution of cool cluster cores heated by feedback-driven bipolar active galactic nuclei (AGNs) jets. Condensation of cold gas, and the consequent enhanced accretion, is required for AGN feedback to balance radiative cooling with reasonable efficiencies, and to match the observed cool core properties. A feedback efficiency (mechanical luminosity ≈ ϵ M-dot {sub acc}c{sup 2}; where M-dot {sub acc} is the mass accretion rate at 1 kpc) as small as 6 × 10{sup −5} is sufficient to reduce the cooling/accretion rate by ∼10 compared to a pure cooling flow in clusters (with M{sub 200}≲7×10{sup 14} M{sub ⊙}). This value is much smaller compared to the ones considered earlier, and is consistent with the jet efficiency and the fact that only a small fraction of gas at 1 kpc is accreted onto the supermassive black hole (SMBH). The feedback efficiency in earlier works was so high that the cluster core reached equilibrium in a hot state without much precipitation, unlike what is observed in cool-core clusters. We find hysteresis cycles in all our simulations with cold mode feedback: condensation of cold gas when the ratio of the cooling-time to the free-fall time (t{sub cool}/t{sub ff}) is ≲10 leads to a sudden enhancement in the accretion rate; a large accretion rate causes strong jets and overheating of the hot intracluster medium such that t{sub cool}/t{sub ff}>10; further condensation of cold gas is suppressed and the accretion rate falls, leading to slow cooling of the core and condensation of cold gas, restarting the cycle. Therefore, there is a spread in core properties, such as the jet power, accretion rate, for the same value of core entropy or t{sub cool}/t{sub ff}. A smaller number of cycles is observed for higher efficiencies and for lower mass halos because the core is overheated to a longer cooling time. The 3D simulations show the formation of a few-kpc scale, rotationally supported, massive (∼10{sup 11} M{sub ⊙}) cold gas torus. Since the torus gas is not accreted onto the SMBH, it is largely decoupled from the feedback cycle. The radially dominant cold gas (T < 5 × 10{sup 4} K; |v{sub r}|>|v{sub ϕ}|) consists of fast cold gas uplifted by AGN jets and freely infalling cold gas condensing out of the core. The radially dominant cold gas extends out to 25 kpc for the fiducial run (halo mass 7×10{sup 14} M{sub ⊙} and feedback efficiency 6 × 10{sup −5}), with the average mass inflow rate dominating the outflow rate by a factor of ≈2. We compare our simulation results with recent observations.
Various particle physics models suggest that, besides the (nearly) cold dark matter that accounts for current observations, additional but sub-dominant dark relics might exist. These could be warm, hot, or even contribute as dark radiation. We present here a comprehensive study of two-component dark matter scenarios, where the first component is assumed to be cold, and the second is a non-cold thermal relic. Considering the cases where the non-cold dark matter species could be either a fermion or a boson, we derive consistent upper limits on the non-cold dark relic energy density for a very large range of velocity dispersions, covering the entire range from dark radiation to cold dark matter. To this end, we employ the latest Planck Cosmic Microwave Background data, the recent BOSS DR11 and other Baryon Acoustic Oscillation measurements, and also constraints on the number of Milky Way satellites, the latter of which provides a measure of the suppression of the matter power spectrum at the smallest scales due to the free-streaming of the non-cold dark matter component. We present the results on the fraction f {sub ncdm} of non-cold dark matter with respect to the total dark matter for different ranges of the non-cold dark matter masses. We find that the 2σ limits for non-cold dark matter particles with masses in the range 1–10 keV are f {sub ncdm}≤0.29 (0.23) for fermions (bosons), and for masses in the 10–100 keV range they are f {sub ncdm}≤0.43 (0.45), respectively.