Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

"Dry-column" chromatography of plant pigments

Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

Woeller, F. H.↗

Electrophoresis technology experiment MA-011

Experiment MA-011, electrophoresis technology, was designed to test electrophoresis hardware that would continue the development of technology for electrophoretic separation of materials in the near zero g environment of space. The experimental hardware generally functioned as planned. Frozen live cells were successfully transported into space, electrophoretic processing was performed, and viable cells were returned to earth. A separation of the three types of fixed red blood cells (rabbit, human, and horse) was demonstrated. The human lymphocytes, however, showed no apparent migration. The separation of human kidney cells produced the most exciting data. Analysis shows electrophoretic separation throughout the entire column with at least four bands of viable cells. The isotachophoresis experiment definitely demonstrated the isotachophoretic separation of biological cells in a near zero g environment.

Allen, R. E.↗

Sequential Separation of Linear, Mono–, and Di–Branched Hexane Isomers on a Robust Coordination Polymer with Nonbonding Flexibility

Efficient separation of hexane isomers is a crucial process for upgrading gasoline. Herein, the sequential separation of linear, mono-, and di-branched hexane isomers by a robust stacked 1D coordination polymer termed as Mn-dhbq ([Mn(dhbq)(H 2 O) 2 ], H 2 dhbq = 2,5-dihydroxy-1,4-benzoquinone) is reported. The interchain space of the activated polymer is of optimal aperture size (5.58 Å) that could exclude 2,3-dimethylbutane, while the chain structure can discriminate n-hexane with high capacity (1.53 mmol g –1 at 393 K, 6.67 kPa) by high-density open metal sites (5.18 mmol g –1 ). With the temperature- and adsorbate-dependent swelling of interchain spaces, the affinity between 3-methylpentane and Mn-dhbq can be deliberately controlled from sorption to exclusion, and thus a complete separation of ternary mixture can be achieved. Column breakthrough experiments confirm the excellent separation performance of Mn-dhbq. Furthermore, the ultrahigh stability and easy scalability further highlight the application prospect of Mn-dhbq for separation of hexane isomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A U.S. Scientific Community Vision for Sustained Earth Observations of Greenhouse Gases to Support Local to Global Action

Managing carbon stocks in the land, ocean, and atmosphere under changing climate requires a globally‐integrated view of carbon cycle processes at local and regional scales. The growing Earth Observation (EO) record is the backbone of this multi‐scale system, providing local information with discrete coverage from surface measurements and regional information at global scale from satellites. Carbon flux information, anchored by inverse estimates from spaceborne Greenhouse Gas (GHG) concentrations, provides an important top‐down view of carbon emissions and sinks, but currently lacks global continuity at assessment and management scales (<100 km). Partial‐column data can help separate signals in the boundary layer from the overlying atmosphere, providing an opportunity to enhance surface sensitivity and bring flux resolution down from that of column‐integrated data (100–500 km). Based on a workshop held in September 2024, the carbon cycle community envisions a carbon observation system leveraging GHG partial columns in the lower and upper troposphere to weave together information across scales from surface and satellite EO data, and integration of top‐down/bottom‐up analyses to link process understanding to global assessment.

Parazoo, Nicholas C. [California Institute of Tech↗

Nitric acid-organic mixtures surveyed for use in separation by anion exchange methods

Column elution-spectrographic analysis technique compares certain solvents directly to the methanol system, using inert rare earths instead of actinides. Distribution ratios for americium between 90 percent solvent, 10 percent 5 M nitric acid and Dowex 1 nitrate form resin for a large group of organics miscible in water was determined.

Bloomquist, C. A. A.↗

Ion-Exclusion Chromatography for Analyzing Organics in Water

A liquid-chromatography technique has been developed for use in the quantitative analysis of urea (and of other nonvolatile organic compounds typically found with urea) dissolved in water. The technique involves the use of a column that contains an ion-exclusion resin; heretofore, this column has been sold for use in analyzing monosaccharides and food softeners, but not for analyzing water supplies. The prior technique commonly used to analyze water for urea content has been one of high-performance liquid chromatography (HPLC), with reliance on hydrophobic interactions between analytes in a water sample and long-chain alkyl groups bonded to an HPLC column. The prior technique has proven inadequate because of a strong tendency toward co-elution of urea with other compounds. Co-elution often causes the urea and other compounds to be crowded into a narrow region of the chromatogram (see left part of figure), thereby giving rise to low chromatographic resolution and misidentification of compounds. It is possible to quantitate urea or another analyte via ultraviolet- and visible-light absorbance measurements, but in order to perform such measurements, it is necessary to dilute the sample, causing a significant loss of sensitivity. The ion-exclusion resin used in the improved technique is sulfonated polystyrene in the calcium form. Whereas the alkyl-chain column used in the prior technique separates compounds on the basis of polarity only, the ion-exclusion-resin column used in the improved technique separates compounds on the basis of both molecular size and electric charge. As a result, the degree of separation is increased: instead of being crowded together into a single chromatographic peak only about 1 to 2 minutes wide as in the prior technique, the chromatographic peaks of different compounds are now separated from each other and spread out over a range about 33 minutes wide (see right part of figure), and the urea peak can readily be distinguished from the other peaks. Although the analysis takes more time in the improved technique, this disadvantage is offset by two important advantages: Sensitivity is increased. The minimum concentration of urea that can be measured is reduced (to between 1/5 and 1/3 of that of the prior technique) because it is not necessary to dilute the sample. The separation of peaks facilitates the identification and quantitation of the various compounds. The resolution of the compounds other than urea makes it possible to identify those compounds by use of mass spectrometry.

Sauer, Richard↗

Organics in water contamination analyzer, phase 1

The requirements which would result in identifying the components of an automatic analytical system for the analysis of specific organic compounds in the space station potable water supply are defined. The gas chromatographic system for such an analysis is limited to commercially available off-the-shelf hardware and includes the sample inlet, an ionization detector, capillary columns as well as computerized compound identification. The sampling system will be a special variation of the purge and trap Tenax mode using six-port valves and a 500 microliter water sample. Capillary columns used for the separating of contaminants will be bonded phase fused silica with a silicone stationary phase. Two detectors can be used: photoionization and far ultraviolet, since they are sensitive and compatible with capillary columns. A computer system evaluation and program with the principle of compound identification based on the retention index is presented.

Source record↗

High-resolution ultraviolet observations of interstellar lines toward Zeta Persei observed with the balloon-borne ultraviolet stellar spectrometer

The balloon-borne ultraviolet stellar spectrometer payload has been used to obtain high-resolution data on interstellar absorption lines toward Zeta Per. The only lines clearly present in the 2150-2450 region were several Fe II features, which show double structure. The two velocity components were sufficiently well separated that it was possible to construct separate curves of growth to derive the Fe II column densities for the individual components. These column densities and the component velocity separation were then used to compute a realistic two-component curve of growth for the line of sight to Zeta Per, which was then used to reanalyze existing ultraviolet data from Copernicus. The results were generally similar to an earlier two-component analysis of the Copernicus data, with the important exception that the silicon depletion increased from near zero to about 1 dex. This makes the Zeta Per depletion pattern quite similar to those derived for other reddened lines of sight, supporting the viewpoint that the general diffuse interstellar medium has a nearly constant pattern of depletions.

Snow, Theodore P.↗

Gas chromatographic separation of nitrogen, oxygen, argon, and carbon monoxide using custom-made porous polymers from high purity divinylbenzene

Existing porous polymers were surveyed for their ability to separate the subject gases. Certain products that showed more promise than others were synthesized and the existing synthetic procedures studied and modified to produce new polymers with enhanced ability to separate the subject gases. Evaluation of the porous polymers was carried out practically by gas chromatography at ambient temperature. The modified synthetic procedures were somewhat simpler than the originals. The new porous polymers made with high purity divinylbenzene enabled use of shorter columns to obtain the separations desired.

Pollock, G. E.↗

A silicone column for GC analysis of polar and nonpolar chemicals

The investigation of the Saturnian System is being proposed jointly by NASA and the European Space Agency (ESA). The mission is scheduled for a launch in 1996. The mission provides an opportunity for close observation and exploration of Saturn's atmosphere, the complex Saturnian System of satellites and rings, Titan (Saturn's planet-sized moon), and Saturn's magnetosphere. The mission gives special attention to Titan which is blanketed by a thick, opaque atmosphere. An atmospheric probe will be deposited into the Titan Atmosphere for in situ measurement during a slow, three hour descent to the surface. The results from this analysis may provide the information which is important to the research of chemical evolution, and the origin of life. An analytical system was developed as a part of the Titan Aerosol Gas Experiment (TAGEX), a proposed experiment for the Cassini Mission. This system will use two highly sensitive detectors, the Metastable Ionization Detector (MID) and the Ion Mobility Spectrometer (IMS). Unfortunately, when commercial columns are utilized with these highly sensitive detectors, volatile components continuously bleed from the column and interfere with the detector. In addition, light columns must be able to separate polar and nonpolar organic chemicals within 10-15 minutes under isothermal conditions for the Titan Mission. Therefore, a highly crosslinked silicone polymeric packed column was developed which is able to efficiently separate amines, alcohols, and hydrocarbons with retention times less that 15 minutes at 100 C isothermal condition.

Shen, T. C.↗

Sources of Variability in the Stratospheric Column of Nitrogen Dioxide

Instruments such as the Global Ozone Monitoring Experiment (GOME, on the European Remote Sensing Satellite (ERS-2), launched 1995), the Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY, on ENVISAT, to be launched July 2001) and the Ozone Monitoring Instrument (OMI on EOS Aura, to be launched 2003) make measurements of the total column of NO2. There is interest in separating the stratospheric and tropospheric contributions to the column, as the tropospheric column provides a measure of pollution. We are using a 3D chemistry and transport model driven by winds from the Goddard Space Flight Center Data Assimilation System to examine variability in the stratospheric NO2 column. Model results for NOx = NO + NO2 + 2N2O5 will be shown to compare well with sunset observations from the Halogen Occultation Experiment on the Upper Atmosphere Research Satellite, and to exhibit similar temporal and spatial dependence. Partitioning between NO, NO2, and N2O5 is also shown to compare well with observations. This good agreement supports the use of simulated fields in the stratosphere to derive the tropospheric column from the total column. Preliminary comparisons of the tropospheric column with model simulations for the troposphere will also be shown.

Douglass, Anne↗

Separation of 'Uncharged' Oligodeoxynucleotide Analogs by Anion-Exchange Chromatography at High pH

Ion-exchange chromatography is a well-established method for the analysis and purification of phosphodiester-linked oligonucleotides. If elution is carried out under alkaline conditions, the secondary structure of G- and C-rich oligomers is disrupted. Furthermore, elution times become more sensitive to the G and T content of the oligomer, because G and T are deprotonated at pH 10. In recent work on peptide-nucleic acids (PNAs) we noted that mixtures of PNA oligomers G(sub 4), G(sub 6), G(sub 8), and G9(sub 10) are readily separated by elution at pH 12 on an RPC-5 column. Here we show that this separation method is more generally applicable.

Schmidt, Jurgen G.↗

Separation of Uncharged Oligodeoxynucleotide Analogs by Anion-Exchange Chromatography at High pH

Ion-exchange chromatography is a well-established method for the analysis and purification of phosphodiester-linked oligonucleotides. If elution is carried out under alkaline conditions, the secondary structure of G- and C-rich oligomers is disrupted. Furthermore, elution times become more sensitive to the G and T content of the oligomer, because G and T are deprotonated at pH 10. In recent work on peptide-nucleic acids (PNAs) we noted that mixtures of PNA oligomers G(sub 4), G(Sub 6), G(sub 8), and G(sub 10) are readily separated by elution at pH 12 on an RPC-5 column. Here we show that this separation method is more generally applicable.

Schmidt, Jurgen G.↗

Scaling Trivalent Actinide and Lanthanide Recovery by Diglycolamide Resin from Savannah River Site’s Mark-18A Targets

The Savannah River National Laboratory is implementing a separation flowsheet to recover rare isotopes and transplutonium elements from irradiated 242 Pu targets known as Mark-18A targets. The Mark-18A targets contain the United States’ supply of nonseparated 244 Pu, which has a wide range of applications from nuclear forensics to production of superheavy elements such as flerovium. The targets also contain hundreds of grams of heavy curium ( 246–248 Cm), which is used as a target material for 252 Cf production. This work investigates the use of diglycolomide resin (DGA Resin) to recover valuable trivalent actinides from the Mark-18A targets. Batch contact experiments were performed on a representative simulant to determine mass loadings. Furthermore, the resin showed an overall capacity of 11 mg/mL for a mixed metal matrix (Zr and La–Gd). Column experiments showed chromatographic separation with transition-metal breakthroughs occurring first followed by the lanthanide series La–Gd. The experiments showed that lanthanide breakthrough occurred after 11 mg/mL mass loading was reached on the column with the mixed metal matrix. A radiological column experiment with an in-line UV/vis cell was able to detect Nd breakthrough just prior to 241 Am breakthrough. Implementing an in-line UV/vis cell into full-scale Mark-18A target processing will be used to limit breakthrough of trivalent actinides recovered from the targets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear effects for the Taylor column for a hemisphere

When a flow is forced past an obstacle in a rapidly rotating fluid, a Taylor column forms. This is defined by a set of vertical detached shear layers circumscribing the obstacle which provide the smooth transition from an external inviscid potential flow to a stagnant core above the obstacle. For a hemispherical object, the main adjustment takes place in an external E to the 1/4 power layer and an internal E to the 2/7 power layer; here, the nonlinear flow in these layers is investigated. The problem in the E to the 1/4 power layer is identical to a problem occurring in magnetohydrodynamic flow; in addition, some features of the magnetohydrodynamic problem have been resolved. Numerical solutions are obtained for the steady nonlinear external E to the 1/4 power layer flow up to the point where unsteady flow separation from the Taylor column is imminent. The response of the internal E to the 2/7 power layer to the flow in the E to the 1/4 power layer is calculated, and the results suggest that the internal shear layer is unlikely to play any significant role in the separation process

Crisalli, A. J.↗

Tritium cleanup system and method

Work area cleanup systems and methods are described for removing tritium from the atmosphere of a work area such as inert gas gloveboxes. Systems utilize a multi-column approach with parallel processing. Tritium of a tritium-contaminated stream is converted into tritiated water and adsorbed onto the separation phase of a first column as a second, parallel column can be simultaneously regenerated. The gaseous stream that exits the column during the regeneration phase can carry a high tritium concentration. The system can also include and a separation stage during which the tritium of the gaseous regeneration stream can be separated from the remainder of the regeneration product.

Xiao, Xin↗

Cation exchange separation of radium and actinium using lactic acid DTPA buffer

The separation of actinium ( 228 Ac) from radium ( 223,228 Ra) on cation exchange resin with a diethylenetriaminpentaacetic acid-lactate buffer solution is demonstrated with series of columns. High yield, high radiopurity (~ 100%) separations of Ac from Ra are feasible with small columns in biologically compatible conditions and pHs. As Ac is eluted before Ra on these columns, further studies were performed to determine if this separation system could be applied to Ra/Ac isotope generators, but these were not successful. In conclusion, the separations presented in this work may be relevant for radiopharmaceutical purifications of 225 Ac which is typically obtained from its 225 Ra parent isotope.

and nuclear chemistry↗