Search NASA⌕ Search

SEARCH · Search NASA

Results for “computed radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

TRINIDI (Time-of-Flight Resonance Imaging with Neutrons for Isotopic Density Inference)

This software is an open-source Python library that provides tools for processing hyperspectral neutron time-of-flight radiography data. This type of data allows material decomposed reconstructions to be generated with the use of material characteristic spectral responses and the algorithms provided in this code library. The software library will contain tools for pre-processing the neutron measurement data, estimating measurement system parameters, reconstructing material decomposed radiographs, and computing material decomposed computed tomography (CT). Furthermore, it will have capability to generate and process simulated neutron time-of-flight data with the goal of benchmarking and demonstrating the tools that are provided. The software will include thorough documentation and application examples.

Balke, Thilo↗

In-situ X-ray and visual observation of foam morphology and behavior at the batch-melt interface during melting of simulated waste glass

We report to attain a basic understanding of the primary foam structure and behavior, which affects the heat and mass transfer and the efficiency of the glass melting process, we investigated the primary foam layer under the glass batch floating on molten glass. The primary foam affects mass transfer during batch melting, in turn affecting the melting process. The recently performed direct in-situ three-dimensional X-ray computed tomography of the batch melting in a laboratory-scale melter vessel allowed us to visualize the features of the reacting batch layer and the foam that develops at its bottom, though with an insufficient resolution of images. In this study, we obtained better temporal and spatial resolution using the two-dimensional X-ray radiography and visual observation of the structure and behavior of transient primary foam as it formed and decayed. As soon as the batch was charged onto the melt surface, foam bubbles began to evolve, grow, and coalesce, forming a primary foam layer, 5-10 mm thick, within tens of seconds. This foam layer was sustained by ongoing gas evolving reactions counterbalanced by bubble coalescence into cavities that moved sideways and escaped to the atmosphere. Eventually, the entire remaining batch turned into foam that gradually decayed at the melt surface. The decay rate agreed with literature observations of surface foam produced by secondary foaming.

36 MATERIALS SCIENCE↗

Experiment K-314: Fetal and neonatal rat bone and joint development following in Utero spaceflight

Infant rat limb specimens from Soviet and U.S. ground-based studies were examined by radiography, macrophotography, histologic sectioning and staining and scanning electron microscopy. A comparison was conducted between vivarium and flight-type diets suggesting that nutritional obesity may adversely affect pregnancy. Data were obtained on maturation of ossification centers, orientation of collagen fibers in bone, tendon and ligaments, joint surface texture and spatial relationships of bones of the hind limb. Computer reconstructions of the knee and hip show promise as a means of investigating the etiology of congenital hip dislocation.

Sabelman, E. E.↗

Mechanical behavior of a ceramic matrix composite material

Monolithic ceramic materials have been used in industry for hundreds of years. These materials have proven their usefulness in many applications, yet, their potential for critical structural applications is limited. The existence of an imperfection in a monolithic ceramic on the order of several microns in size may be critical, resulting in catastrophic failure. To overcome this extreme sensitivity to small material imperfections, reinforced ceramic materials were developed. A ceramic matrix which has been reinforced with continuous fibers is not only less sensitive to microscopic flaws, but is also able to sustain significant damage without suffering catastrophic failure. A borosilicate glass reinforced with several layers of plain weave silicon carbide cloth (Nicalon) was studied. The mechanical testing which was performed included both flexural and tensile loading configurations. This testing was done not only to determine the material properties, but also to initiate a controlled amount of damage within each specimen. Several nondestructive testing techniques, including acousto-ultrasonics (AU), were performed on the specimens periodically during testing. The AU signals were monitored through the use of an IBM compatible personal computer with a high speed data acquisition board. Software was written which manipulates the AU signals in both the time and frequency domains, resulting in quantitative measures of the mechanical response of the material. The measured AU parameters are compared to both the mechanical test results and data from other nondestructive methods including ultrasonic C-scans and penetrant enhanced x ray radiography.

Grosskopf, Paul P.↗

The APL image processing laboratory

The present and proposed capabilities of the Central Image Processing Laboratory, which provides a powerful resource for the advancement of programs in missile technology, space science, oceanography, and biomedical image analysis, are discussed. The use of image digitizing, digital image processing, and digital image output permits a variety of functional capabilities, including: enhancement, pseudocolor, convolution, computer output microfilm, presentation graphics, animations, transforms, geometric corrections, and feature extractions. The hardware and software of the Image Processing Laboratory, consisting of digitizing and processing equipment, software packages, and display equipment, is described. Attention is given to applications for imaging systems, map geometric correction, raster movie display of Seasat ocean data, Seasat and Skylab scenes of Nantucket Island, Space Shuttle imaging radar, differential radiography, and a computerized tomographic scan of the brain.

Jenkins, J. O.↗

Isotopic gamma lines for identification of shielding materials

Identifying the constituting materials of concealed objects is crucial in a wide range of sectors, such as medical imaging, geophysics, nonproliferation, national security investigations, and so on. Existing methods face limitations, particularly when multiple materials are involved or when there are challenges posed by scattered radiation and large areal mass. Here we introduce a novel brute-force statistical approach for material identification using high spectral resolution detectors, such as HPGe. The method relies upon updated semianalytic formulae for computing uncollided flux from source of gamma radiation, shielded by a sequence of nested spherical or cylindrical materials. These semianalytical formulae make possible rapid flux estimation for material characterization via combinatorial search through all possible combinations of materials, using a high-resolution HPGe counting detector. An important prerequisite for the method is that the geometry of the objects is known (for example, from X-ray radiography). We demonstrate the viability of this material characterization technique in several use cases with both simulated and experimental data in spherical geometry.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

A single-scan radiography system has been interfaced to a minicomputer, and the combined system has been used with a variety of fluoroscopic systems and image intensifiers available in clinical facilities. The system's response range is analyzed, and several applications are described. These include determination of the gray scale for typical X-ray-fluoroscopic-television chains, measurement of gallstone volume in patients, localization of markers or other small anatomical features, determinations of organ areas and volumes, computer reconstruction of tomographic sections of organs in motion, and computer reconstruction of transverse axial body sections from fluoroscopic images. It is concluded that this type of system combined with a minimum of statistical processing shows excellent capabilities for delineating small changes in differential X-ray attenuation.

Baily, N. A.↗

CpRad User's Manual

This is the reference manual for users of the C programming language based proton Radiography simulation package CpRad, pronounced "see p-rad." These simulations are developed and maintained by Los Alamos National Laboratory personnel. Currently there are threaded versions, versions written for MPI, as well as versions that use GPUs. The fundamentals of our proton radiography model are well described in a review. The ray tracing in CpRad also includes the incident angle of the protons based on position in the field of view due to the matching conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Uncovering acoustic signatures of pore formation in laser powder bed fusion

Abstract We present a machine learning workflow to discover signatures in acoustic measurements that can be utilized to create a low-dimensional model to accurately predict the location of keyhole pores formed during additive manufacturing processes. Acoustic measurements were sampled at 100 kHz during single-layer laser powder bed fusion (LPBF) experiments, and spatio-temporal registration of pore locations was obtained from post-build radiography. Power spectral density (PSD) estimates of the acoustic data were then decomposed using non-negative matrix factorization with custom $$\varvec{k}$$ k -means clustering (NMF $$\varvec{k}$$ k ) to learn the underlying spectral patterns associated with pore formation. NMF $$\varvec{k}$$ k returned a library of basis signals and matching coefficients to blindly construct a feature space based on the PSD estimates in an optimized fashion. Moreover, the NMF $$\varvec{k}$$ k decomposition led to the development of computationally inexpensive machine learning models which are capable of quickly and accurately identifying pore formation with classification accuracy of supervised and unsupervised label learning greater than 95% and 90%, respectively. The intrinsic data compression of NMF k , the relatively light computational cost of the machine learning workflow, and the high classification accuracy makes the proposed workflow an attractive candidate for edge computing toward in-situ keyhole pore prediction in LPBF.

36 MATERIALS SCIENCE↗

Irradiation of an enriched uranium (NaCl-UCl 3 ) fuel salt capsule, summary of nondestructive post-irradiation examinations, and solidification modeling

Molten salt reactors (MSRs) are gaining attention due to their potential for safe, carbon-free nuclear energy with reduced waste. However, licensing these reactors is hindered by limited experimental data on fueled salts, both pre- and post-irradiation. Here, the novel Molten-salt Research Temperature-controlled Irradiation (MRTI) vehicle was designed to address knowledge gaps in irradiating enriched‑uranium-bearing salts. The MRTI experiment irradiated 13 cm 3 of UCl₃-NaCl (93 % U-235) salt in the Neutron Radiography (NRAD) Reactor, achieving a burnup of 0.196 GWd/MTU over 390 h. Despite a heater failure, the thermocouple data suggested fission heat kept the salt molten. The MRTI assembly was remotely disassembled for nondestructive post-irradiation examination (PIE), which included precision gamma-ray scanning (PGS) and neutron radiography. Radiograph images showed the location of the salt and the solidification pattern. PGS results provided an early indication that activated materials of construction did not increase in relative intensity in the region of the capsule where the salt was in contact with the material of construction. Additionally, PGS data showed the presence of several gamma emitting fission products, such as Nb-95, Zr-95, Ru-103, Ce-141, and La-140, where Ru-103 had the highest counts at the bottom of the capsule. Computational fluid dynamics modeling supported observations of salt solidification patterns and proved to be a valuable tool to inform PIE activities. The MRTI experiment has thus far provided critical data and lessons learned for fuel salt PIE activities, essential for advancing the technical readiness of MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A comprehensive numerical investigation on spray models for Direct-Injection Spark-Ignition engines

Gasoline direct-injection spark-ignition (DISI) engines generate a large portion of their unburned hydrocarbon (UHC) and soot emissions during the cold-start phase. A predictive computational fluid dynamics (CFD) modeling framework can be used to understand the physical processes that characterize fuel spray evolution and fuel-film formation at cold start conditions, which can help to reduce engine-out particulate emissions. This study systematically evaluated spray submodels and developed a set of simulation best practices for physical-numerical submodels with the goal of enabling accurate simulations of liquid spray behavior in a DISI engine. Three comprehensive experimental datasets containing free-spray projected liquid volume (PLV), liquid volume fraction (LVF), and near-field X-ray radiography data were used to validate the simulation results and evaluate the spray submodels. Systematic analysis delved into injected parcel distribution, droplet collision, spray breakup, and evaporation via a detailed assessment of the relevant spray submodels. Moreover, the effects of turbulence models and the initial turbulent flow properties on the liquid spray evolution were examined. Based on extensive calibration efforts, a set of simulation best practices for the free spray was developed and validated against the PLV/LVF data. Simulation results indicated that the uniform distribution for parcel initialization, coupled with appropriate droplet collision submodels, provides an improved spray morphology compared to the cluster distribution. The findings also underscored the importance of calibrating the Kelvin-Helmholtz Rayleigh-Taylor (KH-RT) breakup model constants and droplet heat transfer coefficient scaling factor to achieve favorable agreement regarding measured liquid penetration and spray widths. In conclusion, this study marks a substantial stride towards accurately predicting fuel film evolution and soot formation within DISI engine performance.

ECN Spray G↗

Spot Size Optimization of the Scorpius Accelerator

The Scorpius Linear Induction Accelerator (LIA) is being developed by the Advanced Sources and Diagnostics (ASD) Project and will complement other U1a capabilities by providing a multi-pulse, DARHT-class, flash-radiography capability. Commissioning activities are expected to end in Spring of 2026. All of the diagnostics discussed in this chapter are relevant to LIAs that generate high-current relativistic electron beams, and some diagnostics will also be relevant to other accelerators. The Scorpius Accelerator will be the world’s most advance LIA. Although significant technological advancements have been incorporated throughout the machine, many performance aspects of Scorpius will be similar to those of FXR and DARHT Axis-I and -II. These LIAs offer the same challenges, whether it is suppressing beam instabilities, improving diagnostic accuracy, validating computer simulations and beam tunes, or reducing beam-target interaction effects. However, the ultimate figure of merit is consistent between these LIAs, which is spot size and dose.

43 PARTICLE ACCELERATORS↗

SRM Internal Flow Tests and Computational Fluid Dynamic Analysis: RSRM Full Scale Motor Analyses - Volume 2

The purpose of the RSRM Nozzle Slag Ejection Precursor Test is to investigate the effect that slag ejection from the RSRM nozzle has on the chamber pressure and trust of the SRB's. In past firings of the Reusable Solid Rocket Motor (RSRM) both static test and flight motors have shown small pressure perturbations occurring primarily between 65 and 80 seconds. A joint NASA/Thiokol team investigation concluded that the cause of the pressure perturbations was the periodic ingestion and ejection of molten aluminum oxide slag from the cavity around the submerged nozzle nose which tends to trap and collect individual aluminum oxide droplets from the approach flow. The conclusions of the team were supported by numerous data and observations from special tests including high speed photographic films, real time radiography, plume calorimeters, accelerometers, strain gauges, nozzle TVC system force gauges, and motor pressure and thrust data. A simplistic slag ballistics model was formulated to relate a given pressure perturbation to a required slag quantity. Also, a cold flow model using air and water was developed to provide data on the relationship between the slag flow rate and the chamber pressure increase. Both the motor and the cold flow model exhibited low frequency oscillations in conjunction with periods of slag ejection. Motor and model frequencies were related to scaling parameters. The data indicate that there is a periodicity to the slag entrainment and ejection phenomena which is possibly related to organized oscillations from instabilities in the dividing streamline shear layer which impinges on the underneath surface of the nozzle.

Source record↗

Hubble Systems Optimize Hospital Schedules

Don Rosenthal, a former Ames Research Center computer scientist who helped design the Hubble Space Telescope's scheduling software, co-founded Allocade Inc. of Menlo Park, California, in 2004. Allocade's OnCue software helps hospitals reclaim unused capacity and optimize constantly changing schedules for imaging procedures. After starting to use the software, one medical center soon reported noticeable improvements in efficiency, including a 12 percent increase in procedure volume, 35 percent reduction in staff overtime, and significant reductions in backlog and technician phone time. Allocade now offers versions for outpatient and inpatient magnetic resonance imaging (MRI), ultrasound, interventional radiology, nuclear medicine, Positron Emission Tomography (PET), radiography, radiography-fluoroscopy, and mammography.

Source record↗

Recent Developments in X-Ray Diagnostics for Cryogenic and Optically Dense Coaxial Rocket Sprays

The mixing and atomization of propellants is often characterized by optically dense flow fields and complex breakup dynamics. In the development of propulsion systems, the complexity of relevant physics and the range of spatio-temporal scales often makes computational simulation impractical for full scale injector elements; consequently, continued research into improved systems for experimental flow diagnostics is ongoing. One area of non-invasive flow diagnostics which has seen widespread growth is using synchrotron based x-ray diagostics. Over the past 3 years, a series of water and cryogenic based experiments were performed at the Advanced Photon Source, Argonne National Lab, on a NASA in-house designed swirl co-axial rocket injector, designed for operation using liquid oxygen and liquid methane in support of Project Morpheus. A range of techniques, such as x-ray fluorescence and time-averaged radiography were performed providing qualitative and quantitative mass and phase distributions, and were complemented by investigations using time-resolved radiography and white beam imaging, which provided information on breakup and mixing dynamics. Results of these investigations are presented, and conclusions regarding the viability of x-ray based diagnostics are discussed.

Radke, Christopher D.↗

Automatic information extraction from neutron radiography imaging to estimate axial fuel expansion in $\mathrm{EBR-II}$

Approximately 130,000 metal fuel pins were irradiated in the Experimental Breeder Reactor II (EBR-II) during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed to characterize fuel behavior, like fuel swelling. However, due to the lack of technology or resources, many of the images have not been processed or were processed manually through visual examination. This paper represents first-attempt to develop an image processing algorithm capable of automatically extracting information regarding the degree of fuel swelling from neutron radiography imaging. The algorithm was applied to 120 images of three different metallic fuel pin compositions—U-10Zr, U-8Pu-10Zr, and U-19Pu-10Zr. The algorithm performs operations of image intensity adjustment, image binarization, region finding, and labeling to extract information about fuel swelling. The average growth for U-10Zr was found to be 8.49% with 95% Confidence Interval (CI) [8.33 –8.66%], for U-8Pu-10Zr — 7.50% with 95% CI [7.23 – 7.78%], and for U-19Pu-10Zr — 3.15%, with 95% CI [2.40 – 3.91%]. The results obtained by applying this automatic image processing algorithm are consistent with previously reported studies of the same types of fuels. The automatic image processing algorithm will be expanded to include thousands of available neutron radiography images and different types of fuels to investigate empirical dependencies of fuel swelling, which can be subsequently applied to advanced fuel modeling. Results from this study can later be compared to BISON simulations to further benchmark modeling efforts and develop assessment cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neural network for 3D inertial confinement fusion shell reconstruction from single radiographs

In inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired. To improve the imaging quality as a result of this limitation, convolutional neural networks (CNNs) have recently been shown to be capable of producing 3D models from visible light images or medical x-ray images rendered by volumetric computed tomography. Here, we propose a CNN to reconstruct 3D ICF spherical shells from single radiographs. We also examine the sensitivity of the 3D reconstruction to different illumination models using preprocessing techniques such as pseudo-flatfielding. To resolve the issue of the lack of 3D supervision, we show that training the CNN utilizing synthetic radiographs produced by known simulation methods allows for reconstruction of experimental data as long as the experimental data are similar to the synthetic data. We also show that the CNN allows for 3D reconstruction of shells that possess low mode asymmetries. Further comparisons of the 3D reconstructions with direct multiple LOS measurements are justified.

3D Reconstruction↗