Search NASA⌕ Search

SEARCH · Search NASA

Results for “conjunction analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of linear systems metrics such as robustness, sensitivity across the full spatial frequency range of interest, and normalization to imaging conditions (magnification, system gain settings, and exposure), with the simplicity, ease, and speed of traditional phantom imaging. The algorithm was analyzed for accuracy and sensitivity by comparing with a commercial portal imaging QA method (PIPSPRO, Standard Imaging, Middleton, WI) on both first-generation lens-coupled and modern a-Si flat-panel based clinical EPID systems. The bar-pattern based QA measurements were found to be far more sensitive to even small levels of degradation in spatial resolution and noise. The bar-pattern based QA methodology offers a comprehensive image quality assessment tool suitable for both commissioning and routine EPID QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced vector borne disease surveillance of California Culex mosquito populations reveals spatial and species-specific barriers of infection

Monitoring infections in vectors such as mosquitoes,sand flies, tsetse flies, and ticks to identify human pathogens may serve as an early warning detection system to direct local government disease preventive measures. One major hurdle in detection is the ability to screen large numbers of vectors for human pathogens without the use of genotype-specific molecular techniques. Next generation sequencing (NGS) provides an unbiased platform capable of identifying known and unknown pathogens circulating within a vector population, but utilizing this technology is time-consuming and costly for vector-borne disease surveillance programs. To address this we developed cost-effective Ilumina® RNA-Seq library preparation methodologiesin conjunction with an automated computational analysis pipeline to characterize the microbial populations circulating in Culex mosquitoes (Culex quinquefasciatus, Culex quinquefasciatus/pipiens complex hybrids, and Culex tarsalis) throughout California. We assembled 20 novel and well-documented arboviruses representing members of Bunyaviridae, Flaviviridae, Ifaviridae, Mesoniviridae, Nidoviridae, Orthomyxoviridae, Parvoviridae, Reoviridae, Rhabdoviridae, Tymoviridae, as well as several unassigned viruses. In addition, we mapped mRNA species to divergent species of trypanosoma and plasmodium eukaryotic parasites and characterized the prokaryotic microbial composition to identify bacterial transcripts derived from wolbachia, clostridium, mycoplasma, fusobacterium and campylobacter bacterial species. We utilized these microbial transcriptomes present in geographically defined Culex populations to define spatial and mosquito species-specific barriers of infection. The virome and microbiome composition identified in each mosquito pool provided sufficient resolution to determine both the mosquito species and the geographic region in California where the mosquito pool originated. This data provides insight into the complexity of microbial species circulating in medically important Culex mosquitoes and their potential impact on the transmission of vector-borne human/veterinary pathogens in California.

Langevin, Stanley↗

Modeling thin film, buckle-driven delamination along a metal/polymer interface in a stressed overlayer test.

Interfacial delamination is often the critical failure mode limiting the performance of polymer/metal interfaces. Consequently methods that measure the toughness of such interfaces are of considerable interest. One approach for measuring the toughness of a polymer/metal interface is to use the stressed-overlayer test. In this test a metal substrate is coated with a sub-micron thick polymer film to create the interface of interest. An overlayer, typically a few tenths of a micron of sputtered tungsten, is then deposited on top of the polymer in such a way as to generate a very high residual compressive stress within the sputtered layer ({approx} 1-2 GPa). This highly stressed overlayer induces delamination and blister formation. The measured buckle heights and widths are then used in conjunction with a fracture mechanics analysis to infer interfacial toughness. Here we use a finite element, cohesive-zone-based, fracture analysis to perform the required interfacial crack growth simulation. This analysis shows that calculated crack growth is sensitive to the polymer layer thickness even when the layer is only 10's of nanometers thick. The inward displacement of the overlayer at the buckle edge, which is enabled by the relatively low polymer compliance, is the primary cause of differences from a rigid substrate idealization.

36 MATERIALS SCIENCE↗

Composites Manufacturing Education and Technology Facility Expedites Manufacturing Innovation

The Composites Manufacturing Education and Technology facility (CoMET) at the National Wind Technology Center at the National Renewable Energy Laboratory (NREL) paves the way for innovative wind turbine components and accelerated manufacturing. Available for use by industry partners and university researchers, the 10,000-square-foot facility expands NREL's composite manufacturing research capabilities by enabling researchers to design, prototype, and test composite wind turbine blades and other components -- and then manufacture them onsite. Designed to work in conjunction with NREL's design, analysis, and structural testing capabilities, the CoMET facility expedites manufacturing innovation.

17 WIND ENERGY↗

Statistical Analysis in Support of Control Fuel Temperature for the Advanced Gas Reactor Experiments

There are four completed tests among a series of Advanced Gas Reactor (AGR) irradiation experiments that are being conducted within the Advanced Reactor Technologies (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaigns are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and hypothetical accident conditions, and support development and validation of fuel performance and fission product transport models and codes.1 Since this tristructural isotropic fuel is qualified to be used in high temperature gas-cooled reactors (HTGRs), it is essential that the testing conditions of fuel irradiations are designed to mimic those in the conceptual gas reactors. As a result, temperatures of the AGR test fuel have to be maintained within a specified range that is typical of the HTGRs. In each AGR capsule, the test fuel temperature is controlled independently using a variable fraction neon and helium gas mixture that fills the gap volume for each capsule. The temperature as measured by a thermocouple (TC) terminated in the graphite holder (which houses fuel compacts) is used as a feedback for the gas flow controllers. Direct temperature measurement for fuel compacts is not possible because contact between a TC head and fuel particle could lead to undesirable failures. Therefore, an ABAQUS based finite element thermal model was created to predict the daily average fuel temperatures during the entire irradiation period.2,3 It is well-known that extended exposure to neutron irradiation and high temperatures leads to changes in geometries of fuel compacts and graphite holder, which result in changes of the gas gap leading to a change in the relationship between TC and fuel temperatures. In addition, TCs are also expected to drift and sometimes fail under irradiation conditions. These facts make maintaining test fuel temperature within a specified range challenging. This paper describes how the regression analysis methods are used in conjunction of calculated fuel temperatures from early irradiation periods (when irradiation effect is relatively small) to effectively control fuel temperature for the remaining irradiation, when irradiation effect became profound. This is particularly important in the event of all TCs in a capsule fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Indigenous Organic Molecular Biosignatures are Detectable via ToF-SIMS of a Kerogen-rich Jurassic Clay

Time of Flight - Secondary Ion Mass Spectrometry (ToF-SIMS) is a Mass Spectrometry (MS) imaging technique that can be used in conjunction with traditional organic geochemical analysis (organics extracted from a crushed sample) in order to determine how molecules observed in the organic extracts were incorporated into a particular rock sample. This type of analysis may be used on samples collected as part of Mars Sample Return (MSR) in order to determine if potential organic compounds were indigenous to Mars or whether they are contaminants.Here we show that Organic Molecular Biosignatures (OMBs including steranes and derivatives of a carotenoid) are detectable via ToF-SIMS within a Jurassic mudstone. The OMBs are only detectable in areas with high organic carbon, likely kerogen, indicating that they are indigenous to the rock. We conclude that: I) Indigenous OMBs are detectable via ToF-SIMS in ancient, kerogen-rich samples; II) the presence of a molecular ion strengthens the interpretation of ToF-SIMS spectra of complex natural material, and III) the spatial co-occurrence of kerogen and potentially indigenous OMBs in ancient sediments is a valid test of their character. These conclusions are directly relevant to MSR sample selection as well as the analysis of MSR samples upon return.

Pasterski, Michael↗

Design Approach and Performance Analysis of a Small Integrated Heat Pump (IHP) for Net Zero Energy Homes (ZEH)

This paper describes the design and performance analysis of a variable-capacity heat pump system developed for a small [1800ft2 (167 m2)] prototype net ZEH with an average design cooling load of 1.25 tons (4.4 kW) in five selected US climates. The heat pump integrates space heating and cooling, water heating, ventilation, and humidity control (humidification and dehumidification) functions into a single integrated heat pump (IHP) unit. The design approach uses one small variable-capacity compressor to meet all the above functions in an energy efficient manner. Modal performance comparisons to an earlier IHP product are shown relative to the proposed new design for net ZEH application. The annual performance analysis approach using TRNSYS in conjunction with the ORNL Heat Pump Design Model is discussed. Annual performance projections for a range of locations are compared to those of a base system consisting of separate pieces of equipment to perform the same functions. The ZEH IHP is projected to reduce energy use for space heating & cooling, water heating, dehumidification, and ventilation for a net ZEH by about 50% compared to that of the base system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geometry Optimization for Structural Reliability and Performance of a Thermoelectric Generator

The opposing requirements for the performance and reliability of a thermoelectric generator (TEG) are investigated with numerical finite element analysis simulations. The parameters that significantly influence the operational performance and structural reliability of a TEG are considered for simultaneous optimization. The design of experiments (DOE) based response surface optimization methodology in conjunction with results from finite element analysis was employed to identify optimal parameters from the structural reliability and performance (power output and efficiency) perspectives. A high temperature bismuth telluride based TEG couple was used in the studies to demonstrate the general applicability of the methodology. The response surface methodology is found to be a robust technique that can expedite the process of geometry optimization of a TE device during the research and development phase of TEG devices fabricated from new thermoelectric materials.

Karri, Naveen K.↗

Verification of Reduced Order Modeling Based Uncertainty/Sensitivity Estimator (ROMUSE)

This article presents a number of verification case studies for a recently developed sensitivity/uncertainty code package. The code package, ROMUSE (Reduced Order Modeling based Uncertainty/Sensitivity Estimator) is an effort to provide an analysis tool to be used in conjunction with reactor core simulators, in particular the Virtual Environment for Reactor Applications (VERA) core simulator. ROMUSE has been written in C++ and is currently capable of performing various types of parameter perturbations and associated sensitivity analysis, uncertainty quantification, surrogate model construction and subspace analysis. The current version 2.0 has the capability to interface with the Design Analysis Kit for Optimization and Terascale Applications (DAKOTA) code, which gives ROMUSE access to the various algorithms implemented within DAKOTA, most importantly model calibration. The verification study is performed via two basic problems and two reactor physics models. The first problem is used to verify the ROMUSE single physics gradient-based range finding algorithm capability using an abstract quadratic model. The second problem is the Brusselator problem, which is a coupled problem representative of multi-physics problems. This problem is used to test the capability of constructing surrogates via ROMUSE-DAKOTA. Finally, light water reactor pin cell and sodium-cooled fast reactor fuel assembly problems are simulated via SCALE 6.1 to test ROMUSE capability for uncertainty quantification and sensitivity analysis purposes.

97 MATHEMATICS AND COMPUTING↗

ROMUSE 2.0 User Manual

ROMUSE (Reduced Order Modeling Based Uncertainty/Sensitivity Estimator) is an effort within the Consortium for Advanced Simulation of Light water reactors (CASL) to provide an analysis tool to be used in conjunction with reactor core simulators, especially the Virtual Environment for Reactor Applications (VERA). ROMUSE is written in C++ and is currently capable of performing various types of parameters perturbations, uncertainty quantification, surrogate models construction and subspace analysis. Version 2.0 has the capability to interface with DAKOTA which gives ROMUSE access to the various algorithms implemented within DAKOTA. ROMUSE is mainly designed to interface with VERA and the Comprehensive Modeling and Simulation Suite for Nuclear Safety Analysis and Design (SCALE) [1,2,3], however, ROMUSE can interface with any general model (e.g. python and matlab) with Input/Output (I/O) format that follows the Hierarchical Data Format 5 (HDF5). In this brief user manual, the use of ROMUSE will be overviewed and example problems will be presented and briefly discussed. The algorithms provided here range from algorithms inspired by those discussed in Ref.[4] to nuclear-specific algorithms discussed in Ref. [3].

97 MATHEMATICS AND COMPUTING↗

Theoretical investigation of the interaction of CH{sub 4} with Al{sub 2} and Al{sub 3} neutral and charged clusters

We have studied the interaction of CH{sub 4} with Al{sub 2} and Al{sub 3} neutral and charged clusters in the two lowest lying spin states using density functional theory. These calculations, via extended search, are used to determine the stable positions of H and CH{sub 3} near the cluster, and the transition state to break the H-CH{sub 3} bond. In all cases, stable methyl-aluminum-hydrides are possible. The H desorption is studied by means of vibration analysis and application of transition state theory. A common observed trend is that, in breaking the H-CH{sub 3} bond, the interacting H atom is attached to the 'surface' of the clusters attracting some negative charge of {approx_equal}0.2e. The charge transfer is illustrated using the corresponding orbitals near the transition state in conjunction with the computed Mulliken population analysis. Thermal vibrations, generally, do not enhance the reaction. In all exothermic cases, the binding energy toward CH{sub 3}+HAl{sub n}{sup charge} increases with increasing charge of the original Al{sub n}{sup (q=-1,0,1)} cluster. Although Al lacks occupied d-orbitals, the small Al clusters reduce the (free methane) CH{sub 3}-H dissociation barrier except for Al{sub 3}{sup (q=-1,0)}. The relevant reactions in desorption require {approx}400-700 deg. C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Offshore Wind ENergy Simulation Toolkit

This structural dynamics finite element analysis tool is intended to be used for the analysis of vertical-axis wind turbine (VAWT) and is used in conjunction with the VAWTGen mesh generator. The core of the analysis software is a finite element formulation consisting of the beam element with rotational and stress stiffening effects. Arbitrary VAWT configurations may be constructed by an assembly of beam elements. The software has been designed with a modular approach to facilities interfacing aerodynamics and hydrodynamics software modules in future versions. The software allows for modal and transient analysis capabilities for a rotating VAWT configuration with arbitrary boundary conditions, initial condition, and loads.

Owens, Brian Christopher↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

CASMO5/TSUNAMI-3D spent nuclear fuel reactivity uncertainty analysis

The CASMO5 lattice physics code is used in conjunction with the TSUNAMI-3D sequence in ORNL's SCALE 6 code system to estimate the uncertainties in hot-to-cold reactivity changes due to cross-section uncertainty for PWR assemblies at various burnup points. The goal of the analysis is to establish the multiplication factor uncertainty similarity between various fuel assemblies at different conditions in a quantifiable manner and to obtain a bound on the hot-to-cold reactivity uncertainty over the various assembly types and burnup attributed to fundamental cross-section data uncertainty. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method and Apparatus for Concentrating Vapors for Analysis

An apparatus and method are disclosed for pre-concentrating gaseous vapors for analysis. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable. Vapors sorbed and concentrated within the bed of the apparatus can be thermally desorbed achieving at least partial separation of vapor mixtures. The apparatus is suitable, e.g., for preconcentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than for direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications.

Grate, Jay W↗

Subsurface Characteristics of Metal-Halide Perovskites Polished by an Argon Ion Beam

Focused ion beam (FIB) techniques have been frequently used to section metal-halide perovskites for microstructural investigations. However, the ion beams directly irradiating the sample surface may alter its properties far different from those of pristine, potentially leading to modified deterioration mechanisms under aging stressors. Here, we combine complementary approaches to measure the subsurface characteristics of polished perovskites and identify the chemical species responsible for the measured properties. Analysis of the experimental results in conjunction with Monte Carlo simulations indicates that atomic displacements and local heating occur in the first ≈15 nm of the subsurface of methylammonium lead iodide (MAPbI 3 ) by glancing-angle Ar + beam irradiation (4 kV at 3°). The lead-rich, iodine-deficient surface promotes rapid phase segregation under thermal aging conditions. On the other hand, despite the subsurface modification, our experiments confirm that the rest of the MAPbI 3 bulk retains the material integrity. Our observation supports that polished perovskites could serve in studying the properties of bulk or buried junctions far away from the altered subsurface with care.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interfacial Restructuring of Ionic Liquids Determined by Sum-Frequency Generation Spectroscopy and X-ray Reflectivity

Surface sum-frequency generation spectroscopy and X-ray reflectivity were used to study the surface of [BMIM][X] ionic liquids (BMIM = 1-butyl-3-methylimidazolium cation, X = BF{sub 4}{sup -}, PF{sub 6}{sup -}, and I{sup -}). Sum-frequency signal strength from the terminal methyl groups of the cation at the surface indicates that the topmost surface of these ionic liquids is occupied by polar-oriented hydrophobic butyl chains having approximately 1/3 of the in-plane density of fully packed alkyl chains as observed by the same method for the hexadecanol Langmuir monolayer. X-ray reflectivity data reveal a layer with density larger than that of bulk. However, the reflectivity is not sufficiently sensitive to the exact location of this layer either at the vacuum interface or sandwiched between the bulk and the low-density alkyl chain, as observed in the sum-frequency measurements. Analysis of the reflectivity data in conjunction with the sum-frequency spectra strongly suggests the molecules forming the topmost layer are on average polar-oriented with their (loosely packed) butyl chains toward the gas/liquid interface, while the (densely packed) imidazolium cores/anions are in contact with the bulk liquid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗