Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Exploratory splitter bend system designs for FFA@CEBAF

An upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility (JLAB) is anticipated to provide an electron beam of over 20 GeV using the existing superconducting-RF linear accelerator and new fixed-field alternating (FFA) gradient recirculation arcs made up of Halbach-style permanent magnets. In the current design, the FFA arcs will carry six beams with energies of approximately 11, 13, 16, 18, 20, and 22 GeV which will require horizontal splitter lines to match the beam from the preceding linac. In this paper, we describe two alternative splitter beamline designs that are tuned to match the beam's Twiss parameters, R56, time-of-flight, bend-plane offset, and dispersion into the FFA cells.

Accelerator Physics↗

SINGLE BUNCH TRACKING ON THE TEN-PASS ER@CEBAF ENERGY RECOVERY BEAMLINE

The proposed ten-pass energy recovery linac (ERL) demonstration (five accelerating, five decelerating) at the CEBAF accelerator, ER@CEBAF, involves a multi-GeV en- ergy range of a continuous electron beam. New CEBAF transverse optics were designed for this ERL demonstration. This redesign incorporates additional components in Arc A, including a path length chicane and new quadrupoles to ensure proper dispersion localization. The new five energy recovery passes with a shared arc transport scheme chal- lenge the overall beamline optics design, including large beta functions in the CEBAF spreaders and recombiners. Here we discuss results of bunch tracking performed using the elegant tracking code for the full ER@CEBAF beamline

Neththikumara, I.↗

SRF CAVITY FAULT PREDICTION USING DEEP LEARNING AT JEFFERSON LAB

In this study, we present a deep learning-based pipeline for predicting superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelera-tor Facility (CEBAF) at Jefferson Lab. We leverage pre-fault RF signals from C100-type cavities and employ deep learning to predict faults in advance of their onset. We train a binary classifier model to distinguish between stable and impending fault signals. Test results show accuracies exceeding 99% for distinguishing between normal signals and pre-fault signals from a class of more slowly developing fault types, such as microphonics. We describe results from a proof-of-principle demonstration on a realistic, imbalanced data set and report performance metrics. Encouraging results suggest that future SRF systems could leverage this framework and implement measures to mitigate the onset in more slowly developing fault types.

Rahman, M.↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. A Principal Component Analysis (PCA) approach is being developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and PCA model, along with initial performance metrics. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Carpenter, A.↗

Current status of conceptual horizontal splitter design for FFA@CEBAF energy Upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations of the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. In order to control the beam parameters through these FFA arcs, horizontal splitters must be used. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics↗

Current status of permanent magnet radiation resiliency studies at CEBAF

One possible future for Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) lies in upgrading its maximum nominal energy using Fixed-Field Alternating-gradient (FFA) technology for its recirculating arcs. The current proposal aims to use permanent magnets to supply the fixed fields. One concern among reviewers is the degradation of these permanent magnets during operation due to the radiation environment in which they will be present. This work, funded by a Laboratory Directed R&D grant, aims to measure the magnet degradation in the CEBAF tunnel enclosure, and extrapolate to the energies expected from the upgrade. We present the latest results of this study, as well as plans moving forward.

Accelerator Physics↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator↗

Status Update of Permanent Magnet Radiation Resiliency Studies at CEBAF

The proposed energy upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) incorporates Fixed-Field Alternating-gradient (FFA) arcs utilizing permanent magnet technology. Given the radiation environment within the CEBAF tunnel enclosure, validating the long-term magnetic stability of these materials is a critical step for the project's technical feasibility. This contribution presents an overview of the ongoing permanent magnet radiation resiliency program at Jefferson Lab. We briefly review the experimental methodology used to monitor demagnetization in situ and summarize the operational experience from the initial data-taking campaign. Furthermore, we discuss the upgrades implemented for the second exposure campaign, currently underway, which aims to refine dose correlation and reduce systematic uncertainties. We report on the general status of the program and the roadmap for certifying permanent magnet optics for the proposed upgrade energies.

Bodenstein, R. [Thomas Jefferson National Accelera↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

Field Emission Mitigation in CEBAF SRF Cavities Using Deep Learning

The Continuous Electron Beam Accelerator Facility (CEBAF) operates hundreds of superconducting radio frequency (SRF) cavities in its two main linear accelerators. Field emission can occur when the cavities are set to high operating RF gradients and is an ongoing operational challenge. This is especially true in newer, higher gradient SRF cavities. Field emission results in damage to accelerator hardware, generates high levels of neutron and gamma radiation, and has deleterious effects on CEBAF operations. So, field emission reduction is imperative for the reliable, high gradient operation of CEBAF that is required by experimenters. Here we explore the use of deep learning architectures via multilayer perceptron to simultaneously model radiation measurements at multiple detectors in response to arbitrary gradient distributions. These models are trained on collected data and could be used to minimize the radiation production through gradient redistribution. This work builds on previous efforts in developing machine learning (ML) models, and is able to produce similar model performance as our previous ML model without requiring knowledge of the field emission onset for each cavity.

Ahammed, K.↗

Simulations of positron injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130‑370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The simulation results for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are presented, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, <1 mm bunch length and normalized emittance of <100 mm mrad). The impact of target thickness, drive electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated.

Accelerator Physics↗

Status of conceptual horizontal splitter design for FFA@CEBAF energy upgrade

Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) is currently investigating the feasibility of upgrading its maximum operating energy using Fixed-Field Alternating-gradient (FFA) recirculating arcs to increase the total number of recirculations the beam through the pair of LINACs. These FFA arcs will be composed of permanent magnets, with small Panofsky-style multipole correctors. Horizontal splitters are needed to control the beam parameters through these FFA arcs. The geometrical and physical constraints, as well as the beam matching requirements are very restrictive, complicating the design. This work will show the current status of the most mature design, which includes matching solutions, as well as options for extraction of the beam.

Accelerator Physics↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗

Graph Embeddings for CEBAF Operations: Progress and Future Plans

We describe research towards leveraging deep learning on graph representations of the injector beamline at the Continuous Electron Beam Accelerator Facility (CEBAF) in order to create a tool for improving the efficiency of beam tuning tasks. Specifically, we use graphs to represent the injector beamline at any arbitrary date and time and invoke a graph neural network to extract a low-dimensional, informative representation that can be visualized in two-dimensions. By analyzing years of operational data from the CEBAF archiver, good and bad regions of parameter space can be identified. The goal is to exercise this framework as a real-time tool to aid beam tuning, which represents the dominant source of machine downtime.

Tennant, C.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

Field Emission Mitigation in CEBAF SRF Cavities Using Deep Learning

The Continuous Electron Beam Accelerator Facility (CEBAF) operates hundreds of superconducting radio frequency (SRF) cavities in its two main linear accelerators. Field emission can occur when the cavities are set to high operating RF gradients and is an ongoing operational challenge. This is especially true in newer, higher gradient SRF cavities. Field emission results in damage to accelerator hardware, generates high levels of neutron and gamma radiation, and has deleterious effects on CEBAF operations. So, field emission reduction is imperative for the reliable, high gradient operation of CEBAF that is required by experimenters. Here we explore the use of deep learning architectures via multilayer perceptron to simultaneously model radiation measurements at multiple detectors in response to arbitrary gradient distributions. These models are trained on collected data and could be used to minimize the radiation production through gradient redistribution. This work builds on previous efforts in developing machine learning (ML) models, and is able to produce similar model performance as our previous ML model without requiring knowledge of the field emission onset for each cavity.

Ahammed, K.↗