Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Second law of thermodynamics and quantum feedback control: Maxwell's demon with weak measurements

Recently Sagawa and Ueda [Phys. Rev. Lett. 100, 080403 (2008)] derived a bound on the work that can be extracted from a quantum system with the use of feedback control. For many quantum measurements their bound was not tight. We show that a tight version of this bound follows straightforwardly from recent work on Maxwell's demon by Alicki et al. [Open Syst. Inf. Dyn. 11, 205 (2004)], for both discrete and continuous feedback control. Our analysis also shows that bare, efficient measurements always do non-negative work on a system in equilibrium, but do not add heat.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A modified Bitter-type electromagnet and control system for cold atom experiments

We present a modified Bitter-type electromagnet which features high magnetic field, fine electronic properties and efficient heat removal. The electromagnet is constructed from a stack of copper layers separated by mica layers that have the same shape. A distinctive design of cooling channels on the insulating layers and the parallel ducts between the layers ensures low resistance for cooling water to flow. A continuous current control system is also made to regulate the current through the electromagnet. In our experiment, versatile electromagnets are applied to generate magnetic field and gradient field. From our measurements, a peak magnetic field of 1000 G and a peak gradient field of 80 G/cm are generated in the center of the apparatuses which are 7 cm and 5 cm away from the edge of each electromagnet with a current of 230 A and 120 A, respectively. With the effective feedback design in the current control system and cooling water flow of 3.8 l/min, the stability of the current through the electromagnets can reach 10{sup −5}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Role of Timing in Industrial Control Systems: A Primer

Accurate and synchronized time is an important dependency within an industrial control system. Manipulation or degradation of timing can result in varying impacts based on the critical infrastructure sector. As control systems continue to be digitized and automated, they require more precise timing elements which increases the potential impact of a cyber-attack on timing elements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network Randomization and Dynamic Defense for Critical Infrastructure Systems

Critical Infrastructure control systems continue to foster predictable communication paths, static configurations, and unpatched systems that allow easy access to our nation's most critical assets. This makes them attractive targets for cyber intrusion. We seek to address these attack vectors by automatically randomizing network settings, randomizing applications on the end devices themselves, and dynamically defending these systems against active attacks. Applying these protective measures will convert control systems into moving targets that proactively defend themselves against attack. Sandia National Laboratories has led this effort by gathering operational and technical requirements from Tennessee Valley Authority (TVA) and performing research and development to create a proof-of-concept solution. Our proof-of-concept has been tested in a laboratory environment with over 300 nodes. The vision of this project is to enhance control system security by converting existing control systems into moving targets and building these security measures into future systems while meeting the unique constraints that control systems face.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

ADMINISTRATIVE AND ENGINEERING CONTROLS FOR THE OPERATION OF VENTILATION SYSTEMS FOR UNDERGROUND RADIOACTIVE WASTE STORAGE TANKS

Liquid radioactive wastes from the Savannah River Site are stored in large underground carbon steel tanks. The majority of the waste is confined in double shell tanks, which have a primary shell, where the waste is stored, and a secondary shell, which creates an annular region between the two shells, that provides secondary containment and leak detection capabilities should leakage from the primary shell occur. Each of the DST is equipped with a purge ventilation system for the interior of the primary shell and annulus ventilation system for the secondary containment. Administrative flammability controls require continuous ventilation to remove hydrogen gas and other vapors from the waste tanks while preventing the release of radionuclides to the atmosphere. Should a leak from the primary to the annulus occur, the annulus ventilation would also serve this purpose. The functionality of the annulus ventilation is necessary to preserve the structural integrity of the primary shell and the secondary. An administrative corrosion control program is in place to ensure integrity of the tank. Given the critical functions of the purge and annulus ventilation systems, engineering controls are also necessary to ensure that the systems remain robust. The system consists of components that are constructed of metal (e.g., steel, stainless steel, aluminum, copper, etc.) and/or polymeric (polypropylene, polyethylene, silicone, polyurethane, etc.) materials. The performance of these materials in anticipated service environments (e.g., normal waste storage, waste removal, etc.) was evaluated. The most aggressive vapor space environment occurs during chemical cleaning of the residual heels by utilizing oxalic acid. The presence of NO{sub x} and mercury in the vapors generated from the process could potentially accelerate the degradation of aluminum, carbon steel, and copper. Once identified, the most susceptible materials were either replaced and/or plans for discontinuing operations are executed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO2, PM2.5 and radon; and time-integrated NO2, NOX and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2-2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO2, and NO (NOX-NO2) when operated with WHMV; and also had faster PM2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19 vs. 3%) felt their IAQ could be improved and more reported dryness as a problem (58 vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

air quality↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient Energy Delivery and Control Systems (REDCS) (Final Technical Report)

US critical infrastructure is increasingly the target of cyberattacks, where disturbances could cause considerable damage and disruption. To help provide a new layer of cyber-physical protection for one key energy delivery system, natural gas pipelines, GE Vernova Advanced Research along with partners Florida State University and Intel Corporation created an innovative technology called "Resilient Energy Delivery and Control Systems" (REDCS). This cybersecurity package helps detect anomalies caused by cyberattacks, isolate the subsystem being impacted by the attack, and provide functions that can allow for resiliency – giving better situational awareness to the operators and cybersecurity specialists or in the future perform closed loop control for continued operation while compromised.

03 NATURAL GAS↗

New operator assistance features in the CMS Run Control System

During Run-1 of the LHC, many operational procedures have been automated in the run control system of the Compact Muon Solenoid (CMS) experiment. When detector high voltages are ramped up or down or upon certain beam mode changes of the LHC, the DAQ system is automatically partially reconfigured with new parameters. Certain types of errors such as errors caused by single-event upsets may trigger an automatic recovery procedure. Furthermore, the top-level control node continuously performs cross-checks to detect sub-system actions becoming necessary because of changes in configuration keys, changes in the set of included front-end drivers or because of potential clock instabilities. The operator is guided to perform the necessary actions through graphical indicators displayed next to the relevant command buttons in the user interface. Through these indicators, consistent configuration of CMS is ensured. However, manually following the indicators can still be inefficient at times. A new assistant to the operator has therefore been developed that can automatically perform all the necessary actions in a streamlined order. If additional problems arise, the new assistant tries to automatically recover from these. With the new assistant, a run can be started from any state of the sub-systems with a single click. An ongoing run may be recovered with a single click, once the appropriate recovery action has been selected. We review the automation features of CMS Run Control and discuss the new assistant in detail including first operational experience.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clarification of Institutional Controls at the Rocky Flats Site Central Operable Unit and Implementation of the Soil Disturbance Review Plan - 13053

Cleanup and closure of DOE's Rocky Flats Site in Colorado, which was placed on the CERCLA National Priority List in 1989, was accomplished under CERCLA, RCRA, and the Colorado Hazardous Waste Act (CHWA). The physical cleanup work was completed in late 2005 and all buildings and other structures that composed the Rocky Flats industrial complex were removed from the surface, but remnants remain in the subsurface. Other remaining features include two landfills closed in place with covers, four groundwater treatment systems, and surface water and groundwater monitoring systems. Under the 2006 Corrective Action Decision/Record of Decision for Rocky Flats Plant (US DOE) Peripheral Operable Unit and the Central Operable Unit (CAD/ROD), the response actions selected for the Central Operable Unit (OU) are institutional controls (ICs), physical controls, and continued monitoring and maintenance. The objectives of these ICs were to prevent unacceptable exposure to remaining subsurface contamination and to prevent contaminants from mobilizing to surface water and to prevent interfering with the proper functioning of the engineered components of the remedy. An amendment in 2011 of the 2006 CAD/ROD clarified the ICs to prevent misinterpretation that would prohibit work to manage and maintain the Central OU property. The 2011 amendment incorporated a protocol for a Soil Disturbance Review Plan for work subject to ICs that requires approval from the State and public notification by DOE prior to conducting approved soil-disturbing work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Inspection NDE Results for Fiscal Year 2014, Waste Tanks 26, 27, 28 and 33

Ultrasonic nondestructive examinations (NDE) were performed on waste storage tanks 26, 27, 28 and 33 at the Savannah River Site as a part of the “In-Service Inspection (ISI) Program for High Level Waste Tanks.” No reportable conditions were identified during these inspections. The results indicate that the implemented corrosion control program continues to effectively mitigate corrosion in the SRS waste tanks. Ultrasonic inspection (UT) is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of an 8.5 inch wide strip extending over the accessible height of the primary tank wall and accessible knuckle regions. Welds were also inspected in tanks 27, 28 and 33 with no reportable indications. In a Type III/IIIA primary tank, a complete vertical strip includes scans of five plates (including knuckles) so five “plate/strips” would be completed at each vertical strip location. In FY 2014, a combined total of 79 plate/strips were examined for thickness mapping and crack detection, equating to over 45,000 square inches of area inspected on the primary tank wall. Of the 79 plate/strips examined in FY 2014 all but three have average thicknesses that remain at or above the construction minimum thickness which is nominal thickness minus 0.010 inches. There were no service induced reportable thicknesses or cracking encountered. A total of 2 pits were documented in 2014 with the deepest being 0.032 inches deep. One pit was detected in Tank 27 and one in Tank 33. No pitting was identified in Tanks 26 or 28. The maximum depth of any pit encountered in FY 2014 is 5% of nominal thickness, which is less than the minimum reportable criteria of 25% through-wall for pitting. In Tank 26 two vertical strips were inspected, as required by the ISI Program, due to tank conditions being outside normal chemistry controls for more than 3 months. Tank 28 had an area of localized thinning on the exterior wall of the secondary tank noted during the initial inspections in 2005. That area was inspected again in 2014 and found to be larger and slightly deeper. The deepest area of thinning in the secondary wall is less than 20% wall loss. The maximum length of thinning is less than 24 inches and does not impact structural or leak integrity per WSRC-TR-2002-00063. Inspection results were presented to the In-service Inspection Review Committee (ISIRC) where it was determined that no additional data was required to complete these inspections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Digital Multiphase Composites via Additive Manufacturing

Abstract Mechanical properties of traditional engineering materials are typically coupled to each other, presenting a challenge to practitioners with multi‐dimensional material property requirements. In this work, continuous, independent control over multiple mechanical properties is demonstrated in composite materials realized using additive manufacturing. For the first time, composites additively manufactured from rigid plastic, soft elastomer, and liquid constituents are experimentally characterized, demonstrating materials which span four orders of magnitude in modulus and two orders of magnitude in toughness. By forming analytical mappings between relative concentrations of constituents at the microscale and resulting macroscale material properties, inverse material design is enabled; the method is showcased by printing artifacts with prescribed toughness and elasticity distributions. The properties of these composites are placed in the context of biological tissues, showing they have promise as mechanically plausible tissue mimics.

Smith, Lawrence T.↗

On the challenges facing the handling of solid biomass feedstocks: On the Challenges Facing the Handling of Solid Biomass Feedstocks

With a major global emphasis on the management of waste, alternative resources and a shift to environmentally sustainable technologies, demand for large volumes of heterogeneous solid biomass feedstocks for energy or chemical use is expected to rise significantly. In transforming a sporadic supply of a low-value, highly variable product, to continuous and controlled high throughput systems, a thorough understanding of the feedstock properties will increase in importance. Appropriate characterisation tests are necessary to define technical specification and selection criteria for handling equipment and to appraise the requirement and location for additional processes or pre-treatment to be integrated into the handling chain. Such tests may also influence the material characteristics to be used in the conversion process. In this paper, we discuss the main feedstock attributes associated with a number of handling chain phases and the approach to obtain them. Lastly, the framework for a holistic approach to the characterisation and design of biomass feedstock handling systems for further development and practical implementation is also proposed.

09 BIOMASS FUELS↗

Maternal exposures in the National Birth Defects Prevention Study: Time trends of selected exposures

Background Our objective was to describe time trends in selected pregnancy exposures in the National Birth Defects Prevention Study (NBDPS). Methods We analyzed data from the NBDPS, a multi‐site case–control study of major birth defects, for mothers of live‐born infants without birth defects (controls), with an expected date of delivery (EDD) from 1998 to 2011. Mothers from the 10 participating centers across the United States were interviewed by phone between 6 weeks and 2 years after the EDD. We focused on maternal race/ethnicity and five maternal risk factors: obesity, use of folic acid‐containing multivitamins, opioid analgesics, selective serotonin reuptake inhibitors, and loratadine because of their prevalence of use and some reports of associations with major birth defects. Prevalence time trends were examined using the Kendall's τ β test statistic. Results The exposure trend analysis included 11,724 control mothers with EDDs from 1998 to 2011. We observed a significant increase in obesity prevalence among control mothers, as well as use of selective serotonin reuptake inhibitors and loratadine. We also observed an increase in periconceptional use of folic acid‐containing multivitamins. Some of the time trends varied by race/ethnicity. No remarkable trend in the overall use of opioid analgesics was observed. The racial/ethnic distribution of mothers changed slightly during the study period. Conclusion Long‐term, population‐based case–control studies continue to be an effective way to assess exposure‐birth defects associations and provide guidance to health care providers. However, investigators examining rare outcomes covering many years of data collection need to be cognizant of time trends in exposures. Birth Defects Research (Part A) 103:703–712, 2015. © 2015 Wiley Periodicals, Inc.

Dawson, April L.↗

A framework for understanding efficient diurnal CO 2 reduction using Si and GaAs photocathodes

Integrated solar fuels and photoelectrochemical (PEC) CO 2 reduction (CO 2 R) are promising pathways toward producing value-added chemicals from CO 2 . However, improvements are needed in activity and selectivity as well as in fundamental understanding of device behavior to engender wide deployment. Here, we report two single-junction, integrated photocathodes for PEC CO 2 R based on TOPCon Si and GaAs substrates, which achieve -10 mA cm -2 at -0.33 V vs. RHE with 41% selectivity to C 2+ products and at -0.03 V vs. RHE with 27% selectivity to C 2+ products, respectively. We investigated the viability of a light-mediated strategy to direct selectivity in buried-junction PEC devices and confirmed that these devices could be optimized independently and described by the physics-based models of the individual components. Finally, we designed a framework to assess operational modes for PEC CO 2 R devices and demonstrated this framework under continuous galvanostatic control and variable illumination conditions.

14 SOLAR ENERGY↗

The effect of moisture on hydrocarbon-based solvent liquefaction of pine, cellulose and lignin

In this report we examined the effect of moisture on the solvent liquefaction of loblolly pine, cellulose, and lignin in tetralin at 280 °C and pressures ranging from 15 to 70 bar. Solvent liquefaction experiments were conducted in a quasi-batch reactor capable of continuous pressure control and external vapor condensation. Moisture was varied by the controlled addition of de-ionized water. Control over the system pressure subsequently impacted the removal of water vapor from the reactor. Liquid yield decreased by 25, 21, and 35 wt%, for pine, cellulose, and lignin, respectively, when moisture content was increased from 1 to 50 wt% at 42 bar. Humins were observed in the solid residue from liquefaction of wet cellulose. Wet lignin yielded a substantial amount of solid residue compared to dry lignin with a corresponding decrease in total phenolic monomer production. It was concluded that the ionic dissociation of water was an important factor in loss of liquid yield in the presence of water. Although water was less than 20 wt% of the solvent loading in these experiments, it strongly influenced the liquefaction of biomass and biomass components.

09 BIOMASS FUELS↗

Gas Transport Selectivity of Ultrathin, Nanoporous, Inorganic Membranes Made from Block Copolymer Templates

Here, we report the fabrication of ultrathin, nanoporous silicon nitride membranes made from templates of regular, nanoscale features in self-assembled block copolymer thin films. The inorganic membranes feature thicknesses less than 50 nm and volume porosities over 30%, with straight-through pores that offer high throughout for gas transport and separation applications. As fabricated, the pores are uniformly around 20 nm in diameter, but they can be controllably and continuously tuned to single-digit nanometer dimensions by atomic layer deposition of conformal coatings. A deviation from expected Knudsen diffusion is revealed for transport characteristics of saturated vapors of organic solvents across the membrane, which becomes more significant for membranes of smaller pores. We attribute this to capillary condensation of saturated vapors within membrane pores, which reduces membrane throughput by over 1 order of magnitude but significantly improves the membrane’s selectivity. Between vapors of acetone and ethyl acetate, we measure selectivities as high as 7:1 at ambient pressure and temperature, 4 times more than the Knudsen selectivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗