Single-Axis Tracker Control Optimization Potential for the Contiguous United States

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States: Preprint

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Refinements and Tests of an Advanced Controller to Mitigate Fatigue Loads in the Controls Advanced Research Turbine: Preprint

Wind turbines are complex, nonlinear, dynamic systems forced by aerodynamic, gravitational, centrifugal, and gyroscopic loads. The aerodynamics of wind turbines are nonlinear, unsteady, and complex. Turbine rotors are subjected to a complicated 3-D turbulent wind inflow field, with imbedded coherent vortices that drive fatigue loads and reduce lifetime. Design of control algorithms for windturbines must account for multiple control objectives. Future large multi-megawatt turbines must be designed with lighter weight structures, using active controls to mitigate fatigue loads, while maximizing energy capture. Active damping should be added to these dynamic structures to maintain stability for operation in a complex environment. At the National Renewable Energy Laboratory (NREL), wehave designed, implemented, and tested advanced controls to maximize energy extraction and reduce structural dynamic loads. These control designs are based on linear models of the turbine that are generated by specialized modeling software. In this paper, we present field test results of an advanced control algorithm to mitigate blade, tower, and drivetrain loads in Region 3.

17 WIND ENERGY↗

Development and Validation of a Simulation Testbed for the Intelligent Building Agents Laboratory (IBAL) Using TRNSYS

This paper documents the development and validation of a dynamic primary cooling and thermal storage system simulation testbed. The system simulation testbed, sIBAL, is based on the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), which is a research infrastructure and testbed for the development, evaluation, and demonstration of intelligent control algorithms. The sIBAL testbed developed in this project will serve as a virtual twin of the real facility for future control algorithm development. The details of the methodologies used to develop and validate the simulation testbed, which replicates the dynamic behaviors of the primary cooling and ice storage system in the IBAL facility, are presented. The simulation testbed was developed in TRNSYS using built-in component models and MATLAB functions to replicate the two water-cooled chillers, a thermal storage tank, pumps, valves and other components for four different operation modes. Experiments on IBAL components were designed and executed to generate experimental data for model development and verification of the simulation platform. The validation of the simulation results was carried out in two phases: 1) independent component simulations for the chillers and thermal storage tank, and 2) a combined testbed simulation of the entire hydronic system. Comparison of simulation results to the experimental data obtained from the IBAL facility showed errors within 1 °C for the temperatures outputs of both the chiller and the thermal storage model. The error is within an acceptable range for further intelligent control algorithms development. The findings from the study are summarized and presented along with areas where additional research is needed. In addition, data filtering procedures and model refinement measures utilized to improve the accuracy and accelerate the computation time of the simulation are presented.

cooling systems↗

Testing Controls to Mitigate Fatigue Loads in the Controls Advanced Research Turbine

Wind turbines are complex, nonlinear, dynamic systems forced by aerodynamic, gravitational, centrifugal, and gyroscopic loads. The aerodynamics of wind turbines is nonlinear, unsteady, and complex. Turbine rotors are subjected to a complicated three-dimensional (3D) turbulent wind inflow field with imbedded coherent vortices that drive fatigue loads and reduce lifetime. Design of control algorithms for wind turbines must account for multiple control objectives. Future large multi-megawatt turbines must be designed with lighter weight structures, using active controls to mitigate fatigue loads, maximize energy capture, and add active damping to maintain stability for these dynamically active structures operating in a complex environment. Researchers at the National Renewable Energy Laboratory are designing, implementing, and testing advanced controls to maximize energy extraction and reduce structural dynamic loads. These control designs are based on a linear model of the turbine that is generated by specialized modeling software. This paper describes testing of a control algorithm to mitigate blade, tower, and drivetrain loads using advanced state-space control methods. The controller uses independent blade pitch to regulate the turbine's speed in Region 3, mitigate the effects of shear across the rotor disk, and add active damping to the tower's first fore-aft bending mode. Additionally, a separate generator torque control loop is designed to add active damping to the tower's first side-side mode and the first drivetraintorsion mode. This paper discusses preliminary implementation and field tests of this controller in the Controls Advanced Research Turbine at the National Renewable Energy Laboratory. Also included are preliminary comparisons of the performance of this controller to results from a typical baseline Proportional-Integral-Derivative controller designed with just Region 3 speed regulation as the goal.

17 WIND ENERGY↗

Lab-Scale, Closed-Loop Experimental Characterization, Model Refinement, and Validation of a Hydrokinetic Energy-Harvesting Ocean Kite

This paper presents a study wherein we experimentally characterize the dynamics and control system of a lab-scale ocean kite, and then refine, validate, and extrapolate this model for use in a full-scale system. Ocean kite systems, which harvest tidal and ocean current resources through high-efficiency cross-current motion, enable energy extraction with an order of magnitude less material (and cost) than stationary systems with the same rated power output. However, an ocean kite represents a nascent technology that is characterized by relatively complex dynamics and requires sophisticated control algorithms. In order to characterize the dynamics and control of ocean kite systems rapidly, at a relatively low cost, the authors have developed a lab-scale, closed-loop prototyping environment for characterizing tethered systems, whereby 3D printed systems are tethered and flown in a water channel environment. While this system has been shown to be capable of yielding similar dynamic characteristics to some full-scale systems, there are also fundamental limitations to the geometric scales and flow speeds within the water channel environment, making many other real-world scenarios impossible to replicate from the standpoint of dynamic similarity. Here, to address these scenarios, we show how the lab-scale framework is used to refine and validate a scalable dynamic model of a tethered system, which can then be extrapolated to full-scale operation. In this work, we present an extensive case study of this model refinement, validation, and extrapolation on an ocean kite system intended for operation in the Gulf Stream or similar current environments.

42 ENGINEERING↗

Testing and Expertise for Marine Energy (TEAMER) Program Support - Numerical Modeling Assistance for iProTech's "PIP" WEC Device: Cooperative Research and Development Final Report, CRADA Number CRD-20-17303

Develop a time-domain, 3 degree of freedom numerical model of IProTech's PIP device, including power take-off (PTO), that can be used to develop control algorithms and establish a baseline technology performance level (TPL). This is important to IProTech because having a good numerical model allows IProTech to optimize design and control algorithms on an ongoing basis. A baseline TPL enables the PIP technology to be benchmarked against other wave energy converter (WEC) concepts, providing (i) justification (or not) for investment in wave tank model testing, (ii) identifying optimum design parameters and control algorithms for the test model, (iii) specifying test conditions and (iv) interpreting wave tank test results. An accredited WEC-Sim model of the PIP device is an essential tool for further development of the technology. 1) The development of numerical models of the PIP concept will enable iProTech to evaluate the potential performance of this concept, and to investigate how sensitive the device is to different variables within the system (e.g. hydraulic components, geometry dimensions, etc.) 2) The numerical models were developed with WEC-Sim and PTO-Sim -- the de-facto industry standard WEC numerical modeling tools. A detailed model of the system's hydraulic circuit was developed with PTO-Sim. However, WEC-Sim is based on linear hydrodynamics and has several limitations; validation against high fidelity models/physical scale models would help to build confidence in the results.

16 TIDAL AND WAVE POWER↗

Model Predictive Control of GTAW Weld Pool Penetration

Weld pool penetration is a major implication of weld integrity but it is not directly measurable. The key to solving this issue is to find or create observable phenomena that can be used to derive the penetration. An innovative method has recently been proposed/developed to derive the penetration from the reflection of projected laser from an oscillating weld pool surface. Yet, in addition to the penetration, the oscillation, thus the reflection determined by it, also depends on the pulse amplitude of the current, which needs to be adjusted as the control variable to feedback control the penetration as the output. This dependence imposes a constraint on the control algorithm such that the adjustment of the control variable must be relatively slow to minimize additional sources that affect the oscillation/sensor. This restriction on the control variable adjustment also brings challenges to the identification of the dynamic model of the weld process to be controlled, which has to apply a varying control signal to stimulate the dynamics. To solve these issues, this letter proposes using a low order model to catch the dominant dynamics such that a high speed variation in the control signal can be avoided when choosing the model predictive control algorithm. This allows use of relatively poor models to determine the adjustment on the pulsing amplitude, and still achieves relatively accurate control. Experimental results verified the effectiveness of the resultant penetration control system despite the restrictions imposed by the penetration sensor, which affect the identification of high order dynamics and free adjustments of control variables.

42 ENGINEERING↗

Internship Work Report

I worked on two projects during my summer internship at Sandia. My official title was “Intern - Mission Tech Electrical Eng./Computer Eng.- R&D Undergraduate Summer.” I worked at the central location, which is Albuquerque, New Mexico. The department you are placed in at Sandia doesn’t always correspond to the people you will be working with. For example, I only directly worked with one person from my department this summer. On one of my projects, I worked with a diverse team of engineers from many different departments. On my other project, I mainly worked with two departments, as the project had two distinct parts. As mentioned earlier, I worked on two projects during my summer at Sandia. The first project focused on a lightweight embedded controller in an advanced FPGA System-on-Chip for radar signal processing applications. The term “controller” refers to a hardware device that directs the flow of data between two entities. An FPGA is a reprogrammable integrated circuit (as opposed to an integrated circuit with one purpose). An FPGA was used on this project so in order to protype various ideas for our System-on-Chip. My role on the project was to implement designs on the fabric of the FPGA and design a state machine (written in C) for the processor. My second project was also heavily involved with embedded systems but had a different application. It focused on using a Newton-Raphson control algorithm to stabilize an inverted pendulum using a novel microcontroller. The pendulum dynamics were derived, and it was successfully simulated in MATLAB. I worked on integrating the microcontroller with the inverted pendulum machinery, and converting the Newton-Raphson control algorithm from MATLAB into C. The inverted pendulum was successfully stabilized using a simple PID controller and industry-standard microcontroller. The project is still ongoing, and the team is gearing up for more tests using the novel Newton-Raphson control algorithm and novel microcontroller

42 ENGINEERING↗

Extremum Seeking Control of Smart Inverters for VAR Compensation

Reactive power compensation is used by utilities to ensure customer voltages are within pre-defined tolerances and reduce system resistive losses. While much attention has been paid to model-based control algorithms for reactive power support and Volt Var Optimization (VVO), these strategies typically require relatively large communications capabilities and accurate models. In this work, a non-model-based control strategy for smart inverters is considered for VAR compensation. An Extremum Seeking control algorithm is applied to modulate the reactive power output of inverters based on real power information from the feeder substation, without an explicit feeder model. Simulation results using utility demand information confirm the ability of the control algorithm to inject VARs to minimize feeder head real power consumption. In addition, we show that the algorithm is capable of improving feeder voltage profiles and reducing reactive power supplied by the distribution substation.

Arnold, Daniel↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EKF-Based Enhanced Performance Controller Design for Nonlinear Stochastic Systems

In this paper, a novel control algorithm is presented to enhance the performance of tracking property for a class of non-linear dynamic stochastic systems with unmeasurable variables. To minimize the entropy of tracking errors without changing the existing closed loop with PI controller, the enhanced performance loop is constructed based on the state estimation by extended Kalman Filter and the new controller is designed by full state feedback following this presented control algorithm. Besides, the conditions are obtained for the stability analysis in the mean square sense. In the end, the comparative simulation results are given to illustrate the effectiveness of proposed control algorithm.

Complex industrial process↗

Transactive Control of Commercial Building HVAC Systems

This document details the development and testing of market-based transactive controls for building heating, ventilating and air conditioning (HVAC) systems. These controls are intended to serve the purposes of reducing electricity use through conservation, reducing peak building electric demand, and providing demand flexibility to assist with power system operations. This report is the summary of the first year of work conducted under Phase 1 of the Clean Energy and Transactive Campus Project. The methods and techniques described here were first investigated in simulation, and then subsequently deployed to a physical testbed on the Pacific Northwest National Laboratory (PNNL) campus for validation. In this report, we describe the models and control algorithms we have developed, testing of the control algorithms in simulation, and deployment to a physical testbed. Results from physical experiments support previous simulation findings, and provide insights for further improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear Thermal Rocket Emulator for a Hardware-in-the-Loop Test Bed

To support NASA’s mission to use nuclear thermal rockets for future Mars missions, an instrumentation and control test bed has been built at Oak Ridge National Laboratory. The system is designed as a hardware-in-the-loop test bed for testing control elements and autonomous control algorithms for nuclear thermal propulsion rockets. The mock reactor system consists of a modular and scalable framework, using inexpensive components and open-source software. The hardware system consists of a two-phase flow loop and a mock reactor with six control drums. A single-board computer (NVIDIA Jetson) handles reactor core emulation and hosts a message queuing telemetry transport broker that allows user-deployed control algorithms to interact with the system hardware. The reactor emulator receives sensor data from the hardware and provides the simulated performance of the reactor under steady-state, transient, and fault conditions. The emulator uses a reactivity lookup table and the point kinetics equations to solve for the reactor dynamics in real time. Emulated reactor dynamics and sensor input inform the autonomous control algorithm’s decision-making in a closed-loop manner. The current system is capable of operating at 10 Hz, but faster cycle rates are an area of ongoing research. This test bed will enable NASA and other space vendors to rigorously test their autonomous control systems for NTP rockets under transient (reactor startup and shutdown), steady-state, and fault conditions to reduce development time and risk for autonomous control systems in future missions.

autonomous control↗

Coordinative Real-time Sub-Transmission Volt-VAr Control for Reactive Power Regulation between Transmission and Distribution Systems

This paper introduces an integrated voltage regulation approach to coordinate the Volt-VAr control between transmission and distribution systems. Distributed photovoltaic (PV) systems are aggregated as a virtual power plant (VPP). At the sub-transmission level, a Coordinated Real-time Sub-Transmission Volt-VAr Control Tool (CReST-VCT) is introduced to coordinate the operation of the shunt devices and the reactive power provided by the VPPs. The CReST-VCT uses an enhanced Volt-VAr control algorithm with weighted voltage control objects that include minimizing losses, maintaining the voltage within desirable levels, and minimizing the number of mechanical switching of shunt elements. The algorithm runs every 5 minutes and is solved using AC optimal power flow (OPF) solution technique. The outputs include the settings for each sub-transmission-level Volt-VAr control devices and the reactive power generation requirements for each VPP. Then, each VPP will run a distribution Volt-VAr control algorithm to select the PV inverters that provide the Volt-VAr control services considering the distribution network topology. The goal of the VPP reactive power control is to meet the transmission level service requirements while maintaining the voltage and line flow in the distribution system within limits. Each VPP will update its voltage regulation capacity every 5 minutes to allow the CReST-VCT to formulate the optimization problem for the next dispatch interval. The proposed tool is simulated on Duke Energy Carolina system to demonstrate the capability of providing voltage support service by dispatching of reactive power of distributed PV as VPP.

Ke, Xinda↗

Envisioning the Future Renewable and Resilient Energy Grids—A Power Grid Revolution Enabled by Renewables, Energy Storage, and Energy Electronics

Today’s power grids are facing tremendous challenges because of the ever-increasing power demand, system complexity, infrastructure cost, knowledge base, and policy and regulatory issues to achieve supply–demand power balance and resiliency with respect to more frequent extreme weather events and cyberattacks. It is particularly challenging when the transition toward 100% intermittent renewable energy sources is considered. Many countries are calling for building up more transmission and distribution lines to increase power delivery capacities. This article is an attempt to answer two urgent questions: Is more transmission and distribution infrastructure really needed to meet the increasing power demand? What kind of future grid infrastructure should we envision and build? This article attempts to answer these questions and proposes the concept of community-centric asynchronous renewable and resilient energy grids. By clearly differentiating the concepts of grid resilience and reliability, the importance of building resilient power electronics’ devices and robust system-level control algorithms to achieve 100% renewable energy integrated resilient grids is presented. To identify the shortcomings and propose advancements, power electronics’ technologies are categorized using the proposed concepts of natural source frequencies (NSf), energy storage, direct energy conversion/control and fault protection (DeCaFp), and high-efficiency energy consumption and buffering (heECaB) technology. The ability of networked microgrids to greatly reduce power outages and power system restoration time is demonstrated by leveraging robust decentralized and centralized control algorithms, identified through a comprehensive literature review. Future research areas are proposed to further enhance grid stability, controllability, cybersecurity, and protection against faults in the presence of 100% renewable sources by leveraging the advanced capabilities of NSf, DeCaFp, and heECaB devices and system-level control algorithms.