Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller test bed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Wireless Temperature Sensing Using Permanent Magnets for Nonlinear Feedback Control of Exothermic Polymers

Epoxies and resins can require careful temperature sensing and control in order to monitor and prevent degradation. To sense the temperature inside a mold, it is desirable to utilize a small, wireless sensing element. In this paper, we describe a new architecture for wireless temperature sensing and closed-loop temperature control of exothermic polymers. This architecture is the first to utilize magnetic field estimates of the temperature of permanent magnets within a temperature feedback control loop. We further improve performance and applicability by demonstrating sensing performance at relevant temperatures, incorporating a cure estimator, and implementing a nonlinear temperature controller. This novel architecture enables unique experimental results featuring closed-loop control of an exothermic resin without any physical connection to the inside of the mold. In this paper we describe each of the unique features of this approach including magnetic field-based temperature sensing, Extended Kalman Filtering (EKF) for cure state estimation, and nonlinear feedback control over time-varying temperature trajectories. We use experimental results to demonstrate how low-cost permanent magnets can provide wireless temperature sensing up to ~90°C. In addition, we use a polymer curecontrol test-bed to illustrate how internal temperature sensing can provide improved temperature control over both short and long time-scales. In conclusion, this wireless temperature sensing and control architecture holds value for a range of manufacturing applications.

47 OTHER INSTRUMENTATION↗

Physical Security Model Development of an Electrochemical Facility.

Nuclear facilities in the U.S. and around the world face increasing challenges in meeting evolving physical security requirements while keeping costs reasonable. The addition of security features after a facility has been designed and without attention to optimization (the approach of the past) can easily lead to cost overruns. Instead, security should be considered at the beginning of the design process in order to provide robust, yet efficient physical security designs. The purpose of this work is to demonstrate how modeling and simulation can be used to optimize the design of physical protection systems. A suite of tools, including Scribe3D and Blender, were used to model up a generic electrochemical reprocessing facility. Physical protection elements such as sensors, portal monitors, barriers, and guard forces were added to the model based on best practices for physical security. One outsider theft scenario was examined with 4-8 adversaries to determine security metrics. This work fits into a larger Virtual Test Bed 2020 Milestone in the Material Protection, Accounting, and Control Technologies (MPACT) program through the Department of Energy (DOE). The purpose of the milestone is to demonstrate how a series of experimental and modeling capabilities across the DOE complex provide the capabilities to demonstrate complete Safeguards and Security by Design (SSBD) for nuclear facilities. ACKNOWLEDGEMENTS This work was funded by the Materials Protection, Accounting, and Control Technologies (MPACT) working group as part of the Nuclear Technology Research and Development Program under the U.S. Department of Energy, Office of Nuclear Energy.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Physical Security Model Development of an Electrochemical Facility

Nuclear facilities in the U.S. and around the world face increasing challenges in meeting evolving physical security requirements while keeping costs reasonable. The addition of security features after a facility has been designed and without attention to optimization (the approach of the past) can easily lead to cost overruns. Instead, security should be considered at the beginning of the design process in order to provide robust, yet efficient physical security designs. The purpose of this work is to demonstrate how modeling and simulation can be used to optimize the design of physical protection systems. A suite of tools, including Scribe3D and Blender, were used to model a generic electrochemical reprocessing facility. Physical protection elements such as sensors, portal monitors, barriers, and guard forces were added to the model based on best practices for physical security. Two theft scenarios (an outsider attack and insider diversion) as well as a sabotage scenario were examined in order to optimize the security design. Security metrics are presented. This work fits into a larger Virtual Facility Distributed Test Bed 2020 Milestone in the Material Protection, Accounting, and Control Technologies (MPACT) program through the Department of Energy (DOE). The purpose of the milestone is to demonstrate how a series of experimental and modeling capabilities across the DOE complex provide the capabilities to demonstrate complete Safeguards and Security by Design (SSBD) for nuclear facilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Geomechanical in situ testing of fault reactivation in argillite repositories

Abstract. Pressurization of natural faults as a result of repository-induced effects can lead to their reactivation and permeability generation in case such features are present near disposal tunnels. Potential driving forces for such pressurization are the temperature increase caused by heat-producing high-level radioactive waste and the generation of hydrogen and other gases due to corrosion of engineered materials. We are primarily concerned about pressurization and fault activation in host rocks and faults that have very low natural permeability for pore pressure increases to dissipate, such as the argillite rocks currently investigated in Switzerland, France and other countries. This presentation discusses a series of in situ experiments of fault activation by fluid injection conducted in the argillite rock (Opalinus clay) at the Mont Terri underground research laboratory in Switzerland. A multi-model monitoring test bed was installed at Mont Terri that includes distributed fiber optics for strain, temperature, and acoustics; local fault pore pressure and three-dimensional displacement sensors; active seismic imaging; and passive seismic monitoring. The fault experiments (and their subsequent analysis via hydromechanical modeling) provide a new fundamental understanding of the coupling between pore pressure, fault deformation and permeability generation as a function of time and allow exploring how seismic and aseismic events may impact the integrity of faulted argillite host rock. Our experimental observations demonstrate that significant flow (and transport) can occur along the initially impermeable argillite fault when rupture is activated. However, the fault permeability decreases to almost its pre-activation value when fluid injection ceases and fluid pressure drops. Dilatant slip on the fault plane alone does not explain the observed increase in fault permeability; pressure-induced fault opening also plays a role, favored by the softness of the shale along with the fact that the structure of the fault zone prevents fluids from diffusing into the adjacent damage zone. Rupture initiation and permeability generation is initially aseismic, associated only with an increase in noise level and emerging tremors. Micro-earthquakes are initiated later in the experiments and typically occur away from the fluid-pressurized area. Hydromechanical models show that stress transferred from the initial aseismic deformation can build up to stress criticality and later induce seismic rupture. After presenting the experimental results, we will close the presentation with an outlook to future experimental campaigns using the fault test bed at Mont Terri. We are currently planning a controlled thermal stimulation of the fault, where instead of fluid injection as a trigger mechanism we will heat up the nearby rock volume and measure potential effects on fault stability. Lessons learned from our past and future experiments will help inform the safety assessment of geologic disposal in argillite host rock.

Birkholzer, Jens T.↗

The Fermilab CMTF cryogenic distribution remote control system

The Cryomodule Test Facility (CMTF) is able to provide the necessary test bed for measuring the performance of Superconducting Radio Frequency (SRF) cavities in a cryomodule (CM). The CMTF have seven 300 KW screw compressors, two liquid helium refrigerators, and two Cryomodule Test Stands (CMTS). CMTS1 is designed for 1.3 GHz cryomodule operating in a pulsed mode (PM) and CMTS2 is for cryomodule operating in Half-Wave (HW) and Continuous Wave (CW) mode. Based on the design requirement, each subsystem has to be far away from each other and be placed in distant locations. Therefore choosing Siemens Process Control System 7-400, DL205 PLC, Synoptic and Fermilab ACNET are the ideal choices for CMTF cryogenic distribution real-time remote control system. This paper presents a method which has been successfully used by many Fermilab distribution cryogenic real-time remote control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

To Dim or Not to Dim: Why Is That Still a Difficult Question?

LED lighting is becoming widely adopted and is displacing most traditional lighting technologies. However, the traditional methods used to control light sources have not been similarly displaced. In an effort to address some of the long-standing weaknesses of one of the most popular control methods, the National Electrical Manufacturers Association (NEMA) recently released the ANSI C137.1-2019 standard for 0-10V control of LED drivers and fluorescent ballasts. The new standard builds upon previous specifications by providing requirements for some aspects of dimming-curve shape and endpoints. In order to characterize the performance variation found in market-available LED drivers, and to explore the potential impact of ANSI C137.1, Pacific Northwest National Laboratory’s Connected Lighting Test Bed was used to evaluate the response to 0-10V controls signals of 21 different LED outdoor cobrahead luminaires (typically used for street-lighting applications) that claimed dimmability via a 0-10V interface. The results provide insights about how ANSI C137.1 will affect the performance variation currently found among such products.

0-10V, LED dimming, interoperability↗

Grid Forming Inverter: Laboratory-Scale Hardware Test Bed Setup and Weak Grid Operation

In recent times, the concept of grid forming inverters has gained popularity. Grid forming inverters have proven to be a promising alternative to the grid following inverters. In this paper, we present the hardware test bed implementation of grid forming inverter in islanding mode as well as in grid connected mode. The control structure includes inverter-level inner current control and outer voltage control, and plant-level P - f and Q - V droop control. The Q - V droop provides the voltage command, whereas P - f droop provides the frequency command and is also key for the synchronization process. While it is straightforward to set up the test bed for the islanded operation, it is a challenging process to set up the grid-forming inverter in the grid-connected mode. We present the key technologies and demonstrate the start-up process and weak grid operation using the hardware experiment results. Results from EMT model developed in MATLAB/SimPowerSystems are also presented for side-by-side comparison.

Mittal, Ratik↗

CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Renewable Energy Systems

Pacific Northwest National Laboratory (PNNL) operates the Department of Energy’s (DOE) only dedicated marine laboratory at the PNNL-Sequim campus. PNNL is leading research in the blue economy and marine energy applications and building collaboration between DOE and multiple partners in the state of Washington and beyond. With Washington State support, the Integrated Renewable Energy System (IRES) demonstration testbed proposed here will advance research by developing and testing renewable energy production, management, and use for multiple marine applications (e.g., ocean observations, underwater vehicles, aquaculture). It will also advance energy resiliency for coastal communities by developing an integrated renewable energy test platform that will model how multiple renewable energy resources could power shoreline businesses or communities (Figure 1). The test bed will demonstrate how different renewable systems can be integrated to reduce carbon emissions and contribute to a net zero emissions site and provide lessons, controls, and protocols that will help to expand energy options for shoreline and maritime businesses. The integrated system is expected to serve as a test bed for shoreline power and ocean energy technologies for years to come.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The distribution, orientation, and characteristics of natural fractures for Experiment 1 of the EGS Collab Project, Sanford Underground Research Facility

The EGS Collab project is focused on understanding and predicting permeability enhancement and evolution in crystalline rocks. To accomplish this, the project is creating a suite of intermediate-scale (~10-20 m) field test beds coupled with stimulation and interwell flow tests that will provide a basis to better understand the fracture geometries and processes that control heat transfer between rock and stimulated fractures. As part of the site characterization effort for the first experimental test bed, our team has worked on mapping the distribution, orientation, and nature of open and healed fractures exposed along the drift wall and within the eight bore holes drilled for this test bed. The fractures have been characterized through detailed description of continuous cores obtained from these boreholes, evaluation of televiewer logs, and mapping of fractures and seeps exposed along the drift wall. The fracture data are being compiled and interpreted for slip and dilation tendencies, and will be incorporated into coupled-process geomechanical flow and transport models to better constrain the planned flow and tracer tests.

15 GEOTHERMAL ENERGY↗

Final report : impacts analysis for cyber attack on electric power systems (national SCADA test bed FY09).

The development continues for Finite State Abstraction (FSA) methods to enable Impacts Analysis (IA) for cyber attack against power grid control systems. Building upon previous work, we successfully demonstrated the addition of Bounded Model Checking (BMC) to the FSA method, which constrains grid conditions to reasonable behavior. The new FSA feature was successfully implemented and tested. FSA is an important part of IA for the power grid, complementing steady-state approaches. It enables the simultaneous evaluation of myriad dynamic trajectories for the system, which in turn facilitates IA for whole ranges of system conditions simultaneously. Given the potentially wide range and subtle nature of potential control system attacks, this is a promising research approach. In this report, we will explain the addition of BMC to the previous FSA work and some testing/simulation upon the implemented code using a two-bus test system. The current FSA approach and code allow the calculation of the acceptability of power grid conditions post-cyber attack (over a given time horizon and for a specific grid topology). Future work will enable analysis spanning various topologies (to account for switching events), as well as an understanding of the cyber attack stimuli that can lead to undesirable grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DCDM1: Lessons Learned from the World's Most Energy Efficient Data Center

This presentation discusses the holistic approach to design the world's most energy-efficient data center, which is located at the U.S. Department of Energy National Renewable Energy Laboratory (NREL). This high-performance computing (HPC) data center has achieved a trailing twelve-month average power usage effectiveness (PUE) of 1.04 and features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. We provide details of the demonstrated PUE and energy reuse effectiveness (ERE) and lessons learned during four years of production operation. Recent efforts to dramatically reduce the water footprint will also be discussed. Johnson Controls partnered with NREL and Sandia National Laboratories to deploy a thermosyphon cooler (TSC) as a test bed at NREL's HPC data center that resulted in a 50% reduction in water usage during the first year of operation. The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device with an open cooling tower.

97 MATHEMATICS AND COMPUTING↗

Potential-Controlled Deposition of Multilayer CO 2 Reduction Catalyst Films onto Silicon Photoelectrodes Demonstrates Thickness-Dependent Catalytic Rates

Covalently attaching molecular catalysts to semiconductor surfaces yields promising hybrid photoelectrode architectures for reducing CO 2 to higher-value carbon products. Polymeric molecular catalyst films have higher loading densities than their monolayer counterparts, promising greater rates of solar fuel production. Using photoassisted diazonium electrografting, multilayered films of a Re(apbpy)(CO) 3 Cl CO 2 -reduction catalyst were attached to low-doped p-type Si (pSi). Parallel characterization of the newly formed films with ellipsometry, XPS, and ICP-MS revealed that catalyst loading increased with increasingly negative applied grafting potentials (Vgraft), providing us an experimental test bed to study the effects of film thickness on photocatalytic performance. Controlled-potential electrolysis experiments showed enhanced CO evolution rates on all photoelectrodes with increasingly negative applied potentials (V app ), with thicker films exhibiting the greatest rates of enhancement. Competitive proton reduction reactions at the Si surface were not strongly linked to V app but dependent on film thickness, with thicker films showing increased CO-to-H 2 production ratios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CERTS Microgrid Laboratory Test Bed

The objective of the CERTS Microgrid Test Bed project was to enhance the ease of integrating energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of generating sources less than 100kW. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation, islanding the microgrid's load from a disturbance, thereby maintaining a higher level of service, without impacting the integrity of the utility's electrical power grid; 2) an approach to electrical protection within a limited source microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications between sources. These techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations,and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers Standard 1547 and power quality requirements. The electrical protection system was able to distinguish between normal and faulted operation. The controls were found to be robust under all conditions, including difficult motor starts and high impedance faults. The results from these tests are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or more of the CERTS Microgrid concepts. Future planned microgrid work involves unattended continuous operation of the microgrid for 30 to 60 days to determine how utility faults impact the operation of the microgrid and to gage the power quality and reliability improvements offered by microgrids.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adsorption of selected pharmaceuticals and an endocrine disrupting compound by granular activated carbon. 1. Adsorption capacity and kinetics

The adsorption of two representative PhACs (naproxen and carbamazepine) and one EDC (nonylphenol) were evaluated on two granular activated carbons (GAC) namely coal-based Calgon Filtrasorb 400 and coconut shell-based PICA CTIF TE. The primary objective was to investigate preloading effects by natural organic matter (NOM) on adsorption capacity and kinetics under conditions and concentrations (i.e., ng/L) relevant for drinking water treatment. Isotherms demonstrated that all compounds were significantly negatively impacted by NOM fouling. Adsorption capacity reduction was most severe for the acidic naproxen, followed by the neutral carbamazepine and then the more hydrophobic nonylphenol. The GAC with the wider pore size distribution had considerably greater NOM loading, resulting in lower adsorption capacity. Different patterns for the change in Freundlich KF and 1/n with time revealed different competitive mechanisms for the different compounds. Mass transport coefficients determined by short fixed-bed (SFB) tests with virgin and preloaded GAC demonstrated that film diffusion primarily controls mass transfer on virgin and preloaded carbon. Naproxen suffered the greatest deteriorative effect on kinetic parameters due to preloading, followed by carbamazepine, and then nonylphenol. A type of surface NOM/biofilm, which appeared to add an additional mass transfer resistance layer and thus reduce film diffusion, was observed. In addition, electrostatic interactions between NOM/biofilm and the investigated compounds are proposed to contribute to the reduction of film diffusion. A companion paper building on this work describes treatability studies in pilot-scale GAC adsorbers and the effectiveness of a selected fixed-bed model. 32 refs., 3 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Cool GTL - A New Biogas Conversion Process from GTI

GTI is currently developing the Cool GTL process, to convert biogas into jet fuel. Cool GTL can be used to convert any biogas stream or high CO2 content natural gas to high quality liquid fuels. In Cool GTL we convert high CO2 feeds to synthesis gas at a 2-2.4/1 H2/CO ratio using a novel CO2/steam reforming catalyst which has high stability. The 2.0-2.4/1 H2/CO synthesis gas ratio is always achieved, for a variety of levels of feed CO2 content, by adjusting the amount of water added according to the amount of CO2 in the feed. The reformer catalyst has been tested for 500 hours and shows no deactivation. The product from the reformer then goes directly to a low temperature bubbling fluid bed Fischer Tropsch reactor with an integrated finishing hydroisomerization reactor which makes hydrocarbon liquids from the synthesis gas, With this configuration no wax is produced. The fluid bed allows excellent temperature control. Cool GTL is under development but still requires longer integrated testing. Currently Cool GTL is being developed at GTI through DOE funding in the project “Cool GTL for the Production of Jet Fuel from Biogas”. In this DOE project, our goal is to make 100 gallons of high quality jet fuel. This project will also demonstrate Cool GTL catalyst and process stability through long term, 24 hour operation. Once the DOE project is complete, we believe the Cool GTL process will be ready for larger scale commercial deployment in multiple applications.

09 BIOMASS FUELS↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

High-speed X-ray imaging of droplet-powder interaction in binder jet additive manufacturing

Binder jetting (BJ) is an additive manufacturing process that uses a powder feedstock in a layer wise process to print parts by selectively depositing a liquid binder into the powder bed using inkjet technology. This study presents findings from high-speed synchrotron imaging of binder droplet-interaction during the BJ printing process. A custom laboratory-scale BJ test platform was used for testing which enabled control of relevant process parameters including powder material, print geometry, spacing between droplets, powder bed density, and powder moisture content. Powder ejection was observed above the powder bed surface and powder relocation due to droplet impact was observed below the powder bed surface. Powder relocation was observed to be sensitive to powder material, powder bed density, powder bed moisture, droplet spacing, and print geometry. Increasing powder bed density was found to increase particle ejection velocity but reduce the total number of particles ejected. Process parameters that increase binder / moisture content in the powder bed were found to reduce powder ejection. The number of ejected powder particles was reduced for lower droplet spacings. Both powder ejection and powder relocation below the powder bed were reduced by treating the surface of the powder bed with a water/triethylene glycol (TEG) mixture before printing. In conclusion, results from this study help to build understanding of the physical mechanisms in the BJ printing process that may contribute to formation of defects observed in final parts.

36 MATERIALS SCIENCE↗