A high-pressure, high-temperature combustor and turbine-cooling test facility

NASA-Lewis Research Center is presently constructing a new test facility for developing turbine-cooling and combustor technology for future generation aircraft gas turbine engines. Prototype engine hardware will be investigated in this new facility at gas stream conditions up to 2480 K average turbine inlet temperature and 4,140,000 N per sq m turbine inlet pressure. The facility will have the unique feature of fully-automated control and data acquisition through the use of an integrated system of minicomputers and programmable controllers, which will result in more effective use of operating time, will limit the number of operators required, and will provide a built-in self-protection safety system. The paper describes the facility and the planning and design considerations involved.

Cochran, R. P.↗

Problems encountered in solar heating and cooling systems

Report discussing various experiences of workers at Marshall Space Flight Center in developing solar heating and cooling systems is presented. Presents compilation of problems and their resolutions which can assist designers of solar-energy systems and prevent repetition of errors.

Cash, M.↗

Cooling flows in clusters of galaxies

Cooling gas in the center of many clusters of galaxies is compressed and pushed inward by the thermal pressure of the hot, uncooled outer gas. Gravity acts as a focusing agent until the gas has cooled to galactic temperatures. The cooling process is thermally unstable, giving rise to optical filamentation. Once the gas cools below 10.000 K it presumably forms stars which add to the mass of a central galaxy. Accretion rates of up to 400 solar masses/yr are inferred from X-ray measurements so that the mass of such central galaxies may be due to cooling flows. Their optical and UV appearance emphasize that the gas predominantly turns into low-mass stars with an initial mass function unlike that of the solar neighborhood. Optical and X-ray observations of cooling flows can be used to investigate the continuing formation of the largest known galaxies.

Fabian, A. C.↗

The Application of Remote Sensing using NASA Earth Observations paired with Sociodemographic Indicators to Identify Communities Most Susceptible to Urban Heat Exposure in Austin, Texas

In recent years, Austin, Texas has experienced an increase in population and urban development. Additionally, the City’s climate—already characterized by periods of extreme heat and drought—continues to change. As temperatures and demand for utilities and cooling resources rise, the number of heat-related deaths and illnesses in socially vulnerable populations (e.g., older, lower-income populations) is expected to increase. The City of Austin, The University of Texas at Austin (UT Austin), and The University of Texas Health Science Center at Houston (UT Health) partnered with NASA DEVELOP to examine the distribution of urban heat throughout the City. This project used land surface temperature, greenness, plant water content, and urban surface material analysis parameters derived from NASA Earth observations from Landsat 8 Operational Land Imager (OLI), Landsat 8 Thermal Infrared Sensor (TIRS), and Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS). The project team produced three different indices to create a spatial analysis for the study area including a social vulnerability index (SoVI), heat exposure index (HEI), and an overall heat priority index (HPI) score. This overall score was determined with a weighted analysis of heat-related environmental variables from NASA Earth observations and socioeconomic data from the 2019 American Community Survey. Based on the HPI score, the project team identified 121 census block groups out of 605 total that are designated as being most at risk of adverse impacts from extreme heat events. To test the sensitivity of the HPI, the team used a Monte Carlo analysis using different approaches for geographic scale, variable inclusion, census uncertainty, and index aggregation. Based on the sensitivity analysis, the resulting HPI score showed the metric was consistent with the baseline HPI. This provided increased confidence the score can be used as a tool to make informed infrastructure improvement plans in targeted areas (e.g., siting of cooling centers) and ensure equitable sustainable development.

Ryan Hammock↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

The NASA-Lewis/ERDA Solar Heating and Cooling Technology Program

The NASA Lewis Research Center plans to carry out a major role in the ERDA Solar Heating and Cooling Program. This role would be to create and test the enabling technology for future solar heating, cooling, and combined heating/cooling systems. The major objectives of the project are to achieve reduction in solar energy system costs, while maintaining adequate performance, reliability, life, and maintenance characteristics. The project approach is to move progressively through component, subsystem, and then system technology advancement phases in parallel with continuing manufacturing cost assessment studies. This approach will be accomplished principally by contract with industry to develop advanced components and subsystems. This advanced hardware will be tested to establish 'technology readiness' both under controlled laboratory conditions and under real sun conditions.

Couch, J. P.↗

Optical emission from cooling flows in distant x ray clusters of galaxies

Although the Einstein satellite detected cooling flows in the x ray emission from clusters of galaxies 10 years ago, the understanding of these flows remains incomplete. The x ray emitting gas in the centers of these clusters is so dense that its cooling time is shorter than a Hubble time. Thus gas may cool and flow into the center of the cluster. This cooling gas is thermally unstable and should quickly become inhomogeneous. Optical filamentation (1-100 kpc scales) often appears near the centers of nearby clusters containing cooling flows, usually within the central galaxies accreting the gas. Indeed, only clusters with well-developed cooling flows seem to possess highly luminous, emission-line nebulae. Researchers present here some results of preliminary observational and theoretical studies of this class of emission-line objects. Researchers observed a complete, x ray selected sample of 25 distant clusters of galaxies extracted from the Einstein Extended Medium Sensitivity Survey. They discovered luminous extended H alpha emission in 10 of these clusters. Thus at least 40 percent of the clusters in the sample contain cool gas. If we crudely compare the sample to that of Arnaud (1988), in which approx. 40 percent of his 104 x ray clusters have cooling flows, the result implies that cooling flows may actually be a more common phenomenon in the past than in the present. The connection between the cooling flow and the H alpha emission is a mystery. The straightforward calculation of 1 (photoionization) to 3 (shocks) recombinations per H atom in the cooling flow gives mass infall rates 3 to 100 times greater than M derived from x ray observations. Researchers have made some preliminary theoretical calculations in an attempt to resolve this problem.

Donahue, Megan↗

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

Michael Lewandowski↗

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

The Effect of the Wall Contact and Post-Growth Cool-Down on Defects in CdTe Crystals Grown by 'Contactless' Physical Vapour Transport

A series of cadmium telluride crystals grown by physical vapor transport without contact with the ampoule walls and cooled at different rates were characterized using synchrotron X-ray topography, photoluminescence, and chemical etching. Strain from sticking to silica glass and its effect on the dislocation density is shown. It was found that very fast cool-down increases dislocation density by at least one order of magnitude. None of the samples had random dislocation distributions but coarse clumping of dislocations on the scale of more than 100 microns was more prevalent in slowly cooled crystals. Photoluminescence revealed that slow cooling favored the donor-acceptor luminescence involving complex A centers. This was diminished in fast cooled material; and effect presumed to be due to dislocation gettering. Fast cooling also enhanced the formation of shallow acceptors. Implications for Bridgman growth of CdTe and the vapor growth of CdZnTe are discussed briefly.

Palosz, W.↗

X-Ray Spectroscopy of the Cluster of Galaxies Abell 1795 with XMM-Newton

The initial results from XMM-Newton observations of the rich cluster of galaxies Abell 1795 are presented. The spatially-resolved X-ray spectra taken by the European Photon Imaging Cameras (EPIC) show a temperature drop at a radius of - 200 kpc from the cluster center, indicating that the ICM is cooling. Both the EPIC and the Reflection Grating Spectrometers (RGS) spectra extracted from the cluster center can be described by an isothermal model with a temperature of approx. 4 keV. The volume emission measure of any cool component (less than 1 keV) is less than a few % of the hot component at the cluster center. A strong O VIII Lyman alpha line was detected with the RGS from the cluster core. The O abundance of the ICM is 0.2-0.5 times the solar value. The O to Fe ratio at the cluster center is 0.5 - 1.5 times the solar ratio.

Tamura, T.↗

A Numerical Study of Anti-Vortex Film Cooling Designs at High Blowing Ratio

A concept for mitigating the adverse effects of jet vorticity and liftoff at high blowing ratios for turbine film cooling flows has been developed and studied at NASA Glenn Research Center. This "anti-vortex" film cooling concept proposes the addition of two branched holes from each primary hole in order to produce a vorticity counter to the detrimental kidney vortices from the main jet. These vortices typically entrain hot freestream gas and are associated with jet separation from the turbine blade surface. The anti-vortex design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The anti-vortex film cooling hole concept has been modeled computationally for a single row of 30deg angled holes on a flat surface using the 3D Navier-Stokes solver Glenn-HT. A modification of the anti-vortex concept whereby the branched holes exit adjacent to the main hole has been studied computationally for blowing ratios of 1.0 and 2.0 and at density ratios of 1.0 and 2.0. This modified concept was selected because it has shown the most promise in recent experimental studies. The computational results show that the modified design improves the film cooling effectiveness relative to the round hole baseline and previous anti-vortex cases, in confirmation of the experimental studies.

Heidmann, James D.↗

Characterizing Performance of Additively Manufacturing Regenerative Cooled Combustion Chambers Through Hot Fire Testing

NASA Marshall Space Flight Center (MSFC) has developed several additive manufactured regenerative cooled combustion chambers from 2014 to present. Chambers have been constructed using the Selective Laser Melting (SLM) powder bed additive manufacturing (AM) technique. The materials used for the chambers has varied from Inconel 718, Inconel 625, GRCop-84, and C18150 metal alloys. The surface finish and build techniques used to successfully manufacture combustion chambers using the SLM AM result in as built surface finish and off nominal geometric features. This paper discusses and reviews the effects of surface roughness, flow area, and hydraulic performance of regenerative cooled combustion chambers. The thrust chambers designs tested ranged from 200 to 1,400 psia producing 1,000 to 35,000 lbf thrust. Empirical data from four test campaigns will be reviewed and related to design modeling parameters such as pressure drop, surface roughness, and actual fluid flow geometry. Correlation results with simple 2-D CFD modeling will also be presented. The goal of the work is to better understand how the finished additive manufactured component characteristics inside internal features can effect regenerative cooling chamber design. Adjustments to design methodology will be discussed and recommended based on the above results.

Garcia, C. P.↗

Cooling flows and the formation of massive halos in cD galaxies

X-ray brightness profiles of galaxy clusters frequently indicate the presence of a hot gaseous envelope, and theoretical models predict that numerous low-mass stars will be formed as these gaseous halos cool and contract toward the center of the cluster potential. In this Letter, the optical surface brightness profiles of the halos seen in six cooling flow galaxies are modeled, and it is concluded that the optical profiles and mass-to-light ratios are consistent with the cooling flow accretion hypothesis.

Prestwich, Andrea H.↗

Synthesis of Gold Hydride at High Pressure and High Temperature

Gold is an unreactive metal and its chemical interactions with hydrogen have only recently been explored. Here, in this study, we report the formation of gold hydride above 40 GPa and 2200 K in X-ray free electron laser heated diamond anvil cells using various hydrocarbons as hydrogen sources. Above 40 GPa, a hexagonal phase emerges close to the gold melting point, corresponding to a hydride with stoichiometry Au 2 H x , with x increasing from 0 to near 1 with pressure from 40 to 80 GPa. This is a high-temperature phase which reverts to face centered cubic gold on cooling to 295 K. Accompanying DFT-MD simulations are in excellent agreement with experiment and reveal the structure to consist of an hexagonal close packed gold lattice with atomic hydrogen disordered in the interstices. The hydrogen is superionic and exhibits high diffusivity through the crystalline gold lattice. Our results present the first solid-state binary compound of gold and hydrogen.

Ab initio calculations↗

Mo-100 Disk Structural Integrity Tests I

The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in beam during production. The beam preferentially heats the disk center, while the aggressive cooling by the helium keeps areas outside the beam spot relatively cool. The result is a temperature gradient of up to 900°C over the radial distance of 14.5 mm. To test the disk integrity with this high temperature gradient, a special holder for a single disk was made such that proper cooling can be applied as in the design target and the disk heating can be replicated with induction heating. NorthStar press and sintered disks were used for these tests.

36 MATERIALS SCIENCE↗

Development of a 200 W CW High Efficiency Traveling Wave Tube at 12 GHz

The design, development, and test results are reported for an experimental PPM focused, traveling-wave tube that produces 235 watts of CW RF power over 85 MHz centered at 12.080 GHz. The tube uses a coupled cavity RF circuit with a velocity taper for greater than 30 percent basic efficiency. Overall efficiency of 51 percent is achieved by means of a nine stage depressed collector designed at NASA Lewis Research Center. This collector is cooled by direct radiation to deep space.

Christensen, J. A.↗