Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The center-to-limb

Center-to-limb measurements of the Ca I 6573 intercombination line and the Ca II 7324 forbidden line are compared with synthetic profiles based on a simple representation of the non-LTE Ca-Ca(+) ionization equilibrium. The effects of photoionizations from low lying excited states of neutral calcium are found to reduce the sensitivity of the 6573 center-to-limb behavior as a thermal structure diagnostic. The synthetic center-to-limb behavior is also sensitive to uncertainties in the nonthermal broadening. Nevertheless, the measured center-to-limb behavior of 6573 favors a 'cool' photospheric model over hotter models based on the Ca II K wings. The non-LTE calcium abundance obtained from the disk center equivalent widths of 6573 and 7324 using the best fit model is A(Ca) = 2.1 plus or minus 0.2 x 10 to the -6th (by number relative to hydrogen).

Source record↗

Next-Generation Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

The development of the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is currently underway at NASA Johnson Space Center. The AEMU PLSS features two new evaporative cooling systems, the Reduced Volume Prototype Spacesuit Water Membrane Evaporator (RVP SWME), and the Auxiliary Cooling Loop (ACL). The RVP SWME is the third generation of hollow fiber SWME hardware, and like its predecessors, RVP SWME provides nominal crewmember and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crewmember and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and more flight like back-pressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. In addition to the RVP SWME, the Auxiliary Cooling Loop (ACL), was developed for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feed-water assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the RVP SWME, but is only 25% of the size of RVP SWME, providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a SOV reduction in size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.↗

Reduced Volume Prototype Spacesuit Water Membrane Evaporator; A Next-Generation Evaporative Cooling System for the Advanced Extravehicular Mobility Unit Portable Life Support System

Development of the Advanced Extravehicular Mobility Unit (AEMU) portable life support subsystem (PLSS) is currently under way at NASA Johnson Space Center. The AEMU PLSS features a new evaporative cooling system, the reduced volume prototype (RVP) spacesuit water membrane evaporator (SWME). The RVP SWME is the third generation of hollow fiber SWME hardware. Like its predecessors, RVP SWME provides nominal crew member and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crew member and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and a more flight-like backpressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.↗

Spacesuit Water Membrane Evaporator; An Enhanced Evaporative Cooling System for the Advanced Extravehicular Mobility Unit Portable Life Support System

Development of the Advanced Extravehicular Mobility Unit (AEMU) portable life support subsystem (PLSS) is currently under way at NASA Johnson Space Center. The AEMU PLSS features a new evaporative cooling system, the Generation 4 Spacesuit Water Membrane Evaporator (Gen4 SWME). The SWME offers several advantages when compared with prior crewmember cooling technologies, including the ability to reject heat at increased atmospheric pressures, reduced loop infrastructure, and higher tolerance to fouling. Like its predecessors, Gen4 SWME provides nominal crew member and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crew member and PLSS electronics. Test results from the backup cooling system which is based on a similar design and the subject of a companion paper, suggested that further volume reductions could be achieved through fiber density optimization. Testing was performed with four fiber bundle configurations ranging from 35,850 fibers to 41,180 fibers. The optimal configuration reduced the Gen4 SWME envelope volume by 15% from that of Gen3 while dramatically increasing the performance margin of the system. A rectangular block design was chosen over the Gen3 cylindrical design, for packaging configurations within the AEMU PLSS envelope. Several important innovations were made in the redesign of the backpressure valve which is used to control evaporation. A twin-port pivot concept was selected from among three low profile valve designs for superior robustness, control and packaging. The backpressure valve motor, the thermal control valve, delta pressure sensors and temperature sensors were incorporated into the manifold endcaps, also for packaging considerations. Flight-like materials including a titanium housing were used for all components. Performance testing of the Gen4 SWME is underway.

Bue, Grant C.↗

Comparative assessment of out-of-core nuclear thermionic power systems

The hardware selections available for fabrication of a nuclear electric propulsion stage for planetary exploration were explored. The investigation was centered around a heat-pipe-cooled, fast-spectrum nuclear reactor for an out-of-core power conversion system with sufficient detail for comparison with the in-core system studies completed previously. A survey of competing power conversion systems still indicated that the modular reliability of thermionic converters makes them the desirable choice to provide the 240-kWe end-of-life power for at least 20,000 full power hours. The electrical energy will be used to operate a number of mercury ion bombardment thrusters with a specific impulse in the range of about 4,000-5,000 seconds.

Estabrook, W. C.↗

Application of CFD to aerothermal heating problems

Numerical solutions of the compressible Navier-Stokes equations by an Alternating Direction Implicit scheme, applied to two experimental investigations at NASA Langley Research Center are presented. The first is cooling by injection of a gas jet through the nose of an ogive-cone, and the second is the aerothermal environment in the gap formed by the wing and elevon section of a test model of the Space Shuttle. The simulations demonstrate that accurate pressure calculations are easily obtained on a coarse grid, witih convergence being obtained after the residual reduces by four orders of magnitude. However, accurate heating rates require a fine grid solution, with convergence requiring at least a reduction of six orders of magnitude in the residual. The effect of artificial dissipation on numerical results is also assessed.

Macaraeg, M. G.↗

A 25-LBF gaseous oxygen/gaseous hydrogen thruster for space station application

A prototype 25 lb sub f gaseous oxygen/gaseous hydrogen thruster for Space Station propulsion application was designed and fabricated by Rocketdyne and endurance tested at the NASA/Marshall space Flight Center. The thruster incorporates a regeneratively cooled thrust chamber with a nozzle exit area ratio of 30, a 12-element coaxial injector, a spark igniter, and close-coupled propellant valves. Test results indicate that all major technology issues for long-life gaseous oxygen/gaseous hydrogen thrusters for Space Station application have been resolved.

Heckert, B. J.↗

25-LBF GO2/GH2 space station thruster

Multiple 25-lbf oxygen/gaseous hydrogen thruster assemblies for the Space Station propulsion application were designed and fabricated by Rocketdyne and endurance tested at the NASA/Marshall Space Flight Center. The thrusters incorporate a regeneratively cooled thrust chamber with a nozzle area ratio of 30, a 12-element coaxial injector, an ignition system, and close-coupled propellant valves. The various thruster configurations comprised of mating different injectors and thrust chambers. Over 2 million lbf-sec of impulse was demonstrated at mixture ratios from 3 to 8.4 at vacuum conditions. A thruster was subjected to over 10,000 pulses during which minimum impulse bits of less than 0.5 lb/sec were repeatedly and reliably demonstrated. A total operating time of 25.6 hr was accumulated on the thruster assemblies with one 6.1-hr. continuous firing duration. The thrusters operated between a thrust range of 11.2 and 36.6 lbf. The test results indicate that all major technology issues for long-life gaseous oxygen/gaseous hydrogen thrusters for the Space Station application have been resolved.

Finden, L. E.↗

Optical, ultraviolet, and infrared observations of cooling flows in rich clusters

Many rich clusters are now known to possess centrally located optically emitting gas systems, which accompany large inflows of cooling cluster gas. Recent results of optical, UV, and IR studies on cooling flow clusters are reported which center on three topics: (1) spectroscopic studies of the velocity structure of the line-emitting gas systems, which are used to probe the dynamics of the central cluster regions; (2) filter imaging studies of cluster emission line systems, which have yielded line luminosities and characteristic angular scales; and (3) the results of combining this optical survey with similar surveys undertaken using ultraviolet and infrared satellite data. Carefully flux-calibrated data from this multiwavelength data base have been used to show that a small but significant component of dust extinction is associated with the environment of these clusters.

Hu, Esther M.↗

A monolithic Si bolometer array for the Caltech Submillimeter Observatory

We are developing a submillimeter continuum camera for the Caltech Submillimeter Observatory (CSO) located on Mauna Kea. The camera will employ a monolithic Si bolometer array which was developed by Moseley et al. at the NASA Goddard Space Flight Center (GSFC). The camera will be cooled to a temperature of about 300 mK in a He-3 cryostat, and will operate primarily at wavelengths of 350 and 450 micrometers. We plan to use a bolometer array with 1x24 directly illuminated pixels, each pixel of dimension 1x2 sq mm, which is about half of the F/4 beam size at these wavelengths. Each pixel is 10 to 12 micrometers thick and is supported only by four thin Si legs formed by wet chemical etch. The pixels are doped n-type by phosphorus implantation, compensated by boron implantation. Signals from the bolometer pixels are first amplified by cryogenically cooled FET's. The signals are further amplified by room-temperature amplifiers and then separately digitized by 16 bit A/D converters with differential inputs. The outputs of the A/D converters are fed into a digital signal processing board via fiber-optic cables. The electronics and data acquisition system were designed by the Goddard group. We will report the status of this effort.

Wang, Ning↗

ASCA observations of cooling flows in clusters of galaxies

ASCA spectra of the central regions of three cooling flows, in the Perseus, Centaurus, and A1795 clusters, together with the spectrum of the center of the Coma Cluster, are studied. Absorbed, cooler and/or cooling components are required for the cooling flow spectra but not for that of the Coma Cluster. Problems have been encountered with the basic plasma emission models in the energy range of the iron L complex, which preclude further detailed analysis at present. Our results show the potential of ASCA data for revealing the structure of cooling flows.

Fabian, A. C.↗

Bike Racing Helmet

In 1985, the U.S. Cycling Federation ruled that all racing bikers must wear helmets that meet American National Safety Institute Standards. Existing helmets were hot and heavy. Jim Gentes, president of Giro Sport Design, Inc. turned to Raymond Hicks an aerodynamicist at Ames Research Center for a design for a cool, lightweight helmet. Hicks created an aerodynamic helmet shape using technology from a NACA airfoil section. Air vents make the air flow laminar and reduce drag. Since 1986, Giro helmets have evolved and expanded. One was worn by the 1989 Tour de France winner.

Source record↗

Continuous Lidar Monitoring of Polar Stratospheric Clouds at the South Pole

Polar stratospheric clouds (PSC) play a primary role in the formation of annual ozone holes over Antarctica during the austral sunrise. Meridional temperature gradients in the lower stratosphere and upper troposphere, caused by strong radiative cooling, induce a broad dynamic vortex centered near the South Pole that decouples and insulates the winter polar airmass. PSC nucleate and grow as vortex temperatures gradually fall below equilibrium saturation and frost points for ambient sulfate, nitrate, and water vapor concentrations (generally below 197 K). Cloud surfaces promote heterogeneous reactions that convert stable chlorine and bromine-based molecules into photochemically active ones. As spring nears, and the sun reappears and rises, photolysis decomposes these partitioned compounds into individual halogen atoms that react with and catalytically destroy thousands of ozone molecules before they are stochastically neutralized. Despite a generic understanding of the ozone hole paradigm, many key components of the system, such as cloud occurrence, phase, and composition; particle growth mechanisms; and denitrification of the lower stratosphere have yet to be fully resolved. Satellite-based observations have dramatically improved the ability to detect PSC and quantify seasonal polar chemical partitioning. However, coverage directly over the Antarctic plateau is limited by polar-orbiting tracks that rarely exceed 80 degrees S. In December 1999, a NASA Micropulse Lidar Network instrument (MPLNET) was first deployed to the NOAA Earth Systems Research Laboratory (ESRL) Atmospheric Research Observatory at the Amundsen-Scott South Pole Station for continuous cloud and aerosol profiling. MPLNET instruments are eye-safe, capable of full-time autonomous operation, and suitably rugged and compact to withstand long-term remote deployment. With only brief interruptions during the winters of 2001 and 2002, a nearly continuous data archive exists to the present.

OZONE DESTRUCTION↗

Infrared Spectral Observations While Drilling into a Frozen Lunar Simulant

Past and continuing observations indicate an enrichment of volatile materials in lunar polar regions. While these volatiles may be located near the surface, access to them will likely require subsurface sampling, during which it is desirable to monitor the volatile content. In a simulation of such activities, a multilayer lunar simulant was prepared with differing water content, and placed inside a thermal vacuum chamber at Glenn Research Center (GRC). The soil profile was cooled using liquid nitrogen. In addition to the soil, a drill and infrared (IR) spectrometer (~1600-3400 nm) were also located in the GRC chamber. We report the spectral observations obtained during a sequence where the drill was repeatedly inserted and extracted, to different depths, at the same location. We observe an overall increase in the spectral signature of water ice over the duration of the test. Additionally, we observe variations in the water ice spectral signature as the drill encounters different layers.

volatile content↗

Temperature Mapping of Air Film-Cooled Thermal Barrier Coated Surfaces Using Phosphor Thermometry

While the effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness for jet engine components are usually studied separately, their contributions to combined cooling effectiveness are interdependent and are not simply additive. Therefore, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. Phosphor thermometry offers several advantages for mapping temperatures of air film cooled surfaces. While infrared thermography has been typically applied to study air film cooling effectiveness, temperature accuracy depends on knowing surface emissivity (which may change) and correcting for effects of reflected radiation. Because decay time-based full-field phosphor thermometry is relatively immune to these effects, it can be applied advantageously to temperature mapping of air film-cooled TBC-coated surfaces. In this presentation, an overview will be given of efforts at NASA Glenn Research Center to perform temperature mapping of air film-cooled TBC-coated surfaces in a burner rig test environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and the strengths and limitations of this method for studying air film cooling effectiveness are discussed.

air film cooling↗

High-Aspect-Ratio Cooling Channel Concept Tested in Lewis' Rocket Engine Test Facility

Rocket combustion chamber walls are exposed to the high-temperature environment caused by the combustion of propellants. Even with the walls actively cooled by the fuel, the hot gases can deteriorate the walls severely and limit any possibility for reusing the combustion chamber. For many years, the NASA Lewis Research Center has performed subscale investigations of potential improved cooling concepts to extend the life and reliability of the combustion chamber. Results from previous subscale tests have shown that, by increasing the coolant channel height-to-width aspect ratio, the rocket combustion chamber hot gas side wall temperature can be reduced by as much as 28 percent, without an increase in the coolant pressure drop. Recently, a series of experiments were completed in Lewis' Rocket Engine Test Facility (RETF) to validate the benefits of high aspect ratio cooling channels with a high-pressure, contoured rocket combustion chamber.

Source record↗

Thermal Stability of RP-2 for Hydrocarbon Boost Regenerative Cooling

A series of tests were performed in the NASA Glenn Research Centers Heated Tube Facility to study the heat transfer and thermal stability behavior of RP-2 under conditions similar to those found in rocket engine cooling channels. It has long been known that hydrocarbon fuels, such as RP-2, can decompose at high temperature to form deposits (coke) which can adversely impact rocket engine cooling channel performance. The heated tube facility provides a simple means to study these effects. Using resistively heated copper tubes in a vacuum chamber, flowing RP-2 was heated to explore thermal effects at a range of test conditions. Wall temperature (850-1050F) and bulk fluid temperature (300-500F) were varied to define thermal decomposition and stability at each condition. Flow velocity and pressure were fixed at 75 fts and 1000 psia, respectively. Additionally, five different batches of RP-2 were tested at identical conditions to examine any thermal stability differences resulting from batch to batch compositional variation. Among these tests was one with a potential coke reducing additive known as 1,2,3,4-Tetrahydroquinoline (THQ). While copper tubes were used for the majority of tests, two exploratory tests were performed with a copper alloy known as GRCop-42. Each tube was instrumented with 15 thermocouples to examine the temperature profile, and carbon deposition at each thermocouple location was determined post-test in an oxidation furnace. In many tests, intermittent local temperature increases were observed visually and in the thermocouple data. These hot spots did not appear to correspond with a higher carbon deposition.

Kleinhenz, Julie E.↗

Mapping the dark matter in the NGC 5044 group with ROSAT: Evidence for a nearly homogeneous cooling flow with a cooling wake

The NGC 5044 group of galaxies was observed by the ROSAT Position Sensitive Proportional Counter (PSPC) for 30 ks during its reduced pointed phase (1991 July). Due to the relatively cool gas temperature in the group (kT = 0.98 +/- 0.02 keV) and the excellent photon statistics (65,000 net counts), we are able to determine precisely a number of fundamental properties of the group within 250 kpc of the central galaxy. In particular, we present model-independent measurements of the total gravitating mass, the temperature and abundance profiles of the gas, and the mass accretion rate. Between 60 and 250 kpc, the gas is nearly isothermal with T varies as r(exp (-0.13 +/- 0.03)). The total gravitating mass of the group can be unambiguously determined from the observed density and temperature profiles of the gas using the equation of hydrostatic equilibrium. Within 250 kpc, the gravitating mass is 1.6 x 10(exp 13) solar mass, yielding a mass-to-light ratio of 130 solar mass/solar luminosity. The baryons (gas and stars) comprise 12% of the total mass within this radius. At small radii, the temperature clearly increases outward and attains a maximum value at 60 kpc. The positive temperature gradient in the center of the group confirms the existence of a cooling flow. The cooling flow region extends well beyond the temperature maximum with a cooling radius between 100 and 150 kpc. There are two distinct regions in the cooling flow separated by the temperature maximum. In the outer region, the gas is nearly isothermal with a unifor m Fe abundance of approximately 80% solar, the flow is nearly homogeneous with dot-M= 20 to 25 solar mass/year, the X-ray contours are spherically symmetric, and rho(sub gas) varies as r(exp -1.6). In the inner region, the temperature profile has a positive gradient, the mass accretion rate decreases rapidly inward, the gas density profile is steeper, and the X-ray image shows some substrucutre. NGC 5044 is offset from the centroid of the outer X-ray contours indicating that the central galaxy may have a residual velocity with respect to the center of the group potential. There is also a linear X-ray feature with an extent of approximately 30 kpc with one end coincident with NGC 5044. The X-ray emission from this feature is softer than the ambient gas. We interpret this feature as a 'cooling wake' formed by the accreting gas as it is gravitationally focused into the wake of NGC 5044. One of the most surprising results of our PSPC observation is the discovery of a nearly homogeneous cooling flow. Prior results concerning the mass accretion profile in cooling flows indicate that dot-M varies as r. This relation implies that significant mass deposition occurs at large radii which generates an inhomogeneous flow. The mass accretion rate in the NGC 5044 group is essentially a constant beyond 40 kpc (well within the cooling radius). Significant mass deposition (a declining dot-M) does not commence until the gas accretes to within 40 kpc of the group center where the radiative cooling time is approximately equals 10(exp 9) year. Th is radius also corresponds to the temperature maximum, the break in gas density profile, and the onset of structure in the X-ray image. A Hubble constant of H(sub 0) = 50 km/sec/Mpc is used throughout the paper.

David, Laurence P.↗