Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design Study of a Superconducting Quadrupole Magnet System Sustainable Under Dark Current Heating in ILC Main Linac

The International Linear Collider (ILC) main linac comprises a series of 12 m-long cryomodules. The cryomodule contains eight 9-cell superconducting (SC) RF (SRF) cavities and an SC quadrupole magnet combined with dipole correctors to focus and steer electron and positron beams. The magnets are installed between the SRF cavity string and at the longitudinal center of a common cryomodule/cryostat. These magnets are conductively cooled by pure aluminum channels thermally connected to a 2 K two-phase helium pipe for cooling the SRF cavities. A recent study shows that field-emitted electrons, so-called “dark current” initiated in the SRF cavities, are transmitted through the SRF cavity string and reach the SC magnet. The energy is inevitably absorbed in the SC coil due to the magnetic field, resulting in risks of a quench caused by the coil heating. We are investigating alternate magnet designs by using Nb $_{3}$ Sn or $\text{MgB}_{2}$ SC and by adding the dark current absorber surrounding the beam-pipe to realize sustainable magnet operation under the dark current heating. We report the design study of the magnet system and interfaces to the cryomodule accommodating it with the SRF cavities.

43 PARTICLE ACCELERATORS↗

Verification of Reactor Activation Modelling with Physical Characterization Data and the Impact on Long Term Assessments - 20303

Whiteshell Laboratories, located in Manitoba, Canada, provided research facilities for the Canadian nuclear industry since the early 1960's. The facility was centered on Whiteshell Reactor 1 (WR-1), an organically cooled, heavy water moderated nuclear reactor. WR-1 was safely shut down in 1985, defueled and drained, and has been in a safe Storage with Surveillance (Deferred Decommissioning) state until present day. In support of an Environmental Assessment for proposed in-situ disposal of WR-1, detailed characterization information regarding the reactor core components (calandria, calandria tubes, and pressure tubes) was necessary to provide confidence that the long-term impacts of the facility can be assessed adequately. A simplified estimate of the total activation of core components was completed in 1992 using conservative assumptions, expected reactor configuration and computer models built with WIMS-CRNL, ONEDANT and ORIGEN-S. Due to the simplification, and age of the work, there was considerable doubt that the modelled inventory estimate of the core components was sufficient to support long-term performance modeling of the planned in-situ decommissioning. Additional data would be required to provide this confidence. Several options were considered for characterizing the WR-1 core components, but it was decided to collect only a limited number of samples in an effort to validate the 1992 simplified estimate as bounding. The limited number of samples reduced risks to workers, both radiological and non-radiological, and significantly reduced the costs required to confidently define and bound the radiological inventory of activation products in the core. The results of the sampling were compared to the simplified activation estimation. There was good agreement between the modelled and sampled results, with all major contributors to total activity showing similar relative quantities. The samples were generally lower than predicted by the models, with few exceptions. Notable exceptions included Nb-94, which were higher in the sample results than the model. This was determined to be caused by the use of Niobium containing steel alloys in the stainless steel pressure tube that were not accounted for in the models. The comparison of results provided confidence that the original inventory estimates produced through the simplified model are conservative and bounding, and therefore suitable for use in the long-term assessment of in situ disposal of the WR-1 reactor. This paper provides details of the simplified computer model results, their comparison to results of the sampling, and the changes adopted in the assessment of the in-situ decommissioning of WR-1 as a result. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Tale of Two Rapidly Intensifying Supertyphoons: Hagibis (2019) and Haiyan (2013)

Devastating Japan in October 2019, Supertyphoon (STY) Hagibis was an important typhoon in the history of the Pacific. A striking feature of Hagibis was its explosive rapid intensification (RI). In 24 h, Hagibis intensified by 100 knots (kt; 1 kt ≈ 0.51 m s –1 ), making it one of the fastest-intensifying typhoons ever observed. After RI, Hagibis’s intensification stalled. Using the current typhoon intensity record holder, i.e., STY Haiyan (2013), as a benchmark, this work explores the intensity evolution differences of these two high-impact STYs. We found that the extremely high prestorm sea surface temperature reaching 30.5°C, deep/warm prestorm ocean heat content reaching 160 kJ cm –2 , fast forward storm motion of ~8 m s –1 , small during-storm ocean cooling effect of ~0.5°C, significant thunderstorm activity at its center, and rapid eyewall contraction were all important contributors to Hagibis’s impressive intensification. There was 36% more air–sea flux for Hagibis’s RI than for Haiyan’s. After its spectacular RI, Hagibis’s intensification stopped, despite favorable environments. Haiyan, by contrast, continued to intensify, reaching its record-breaking intensity of 170 kt. A key finding here is the multiple pathways that storm size affected the intensity evolution for both typhoons. After RI, Hagibis experienced a major size expansion, becoming the largest typhoon on record in the Pacific. This size enlargement, combined with a reduction in storm translational speed, induced stronger ocean cooling that reduced ocean flux and hindered intensification. Furthermore, the large storm size also contributed to slower eyewall replacement cycles (ERCs), which prolonged the negative impact of the ERC on intensification.

54 ENVIRONMENTAL SCIENCES↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two Cycling Centers in One Molecule: Communication by Through-Bond Interactions and Entanglement of the Unpaired Electrons

Many applications in quantum information science (QIS) rely on the ability to laser- cool molecules. The scope of applications can be expanded if laser-coolable molecules possess two or more cycling centers, i.e., moieties capable of scattering photons via multiple absorption-emission events. Here in this paper we employ equation-of-motion coupled-cluster method for double electron attachment (EOM-DEA-CCSD) to study the electronic structure of hypermetallic molecules with two alkaline earth metals connected by an acetylene linker. The electronic structure of the molecules is similar to that of two separated alkali metals; however, the interaction between the two electrons is weak and largely dominated by through-bond interactions. The communication between the two cycling centers is quantified by the extent of the entanglement of the two unpaired electrons associated with each center. This contribution highlights the rich electronic structure of hypermetallic molecules that may advance various applications in QIS and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RELAP5-3D Solutions to Exercise 1 of the OECD-NEA HTTF Benchmark

Discussion of RELAP5-3D solutions to Exercise 1 of the OECD-NEA High Temperature Test Facility (HTTF) Benchmark. Results from ongoing benchmark activities supported by the Advanced Reactor Technologies - Gas-Cooled Reactor Program with use of the High Performance Computing Center at Idaho National Laboratory. Also discussion of Ultra Safe Nuclear Corporation and BWXT plans for the decade, and issues of modern thermal hydraulic tools for prismatic HTGR modeling. Open discussion of verification and validation and ART-GCR campaign to spearhead the development of an HTGR thermal hydraulics benchmark based on the HTTF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Reduced photothermal heating in diamonds enriched with H3 point defects

Solid-state laser refrigeration of semiconductors remains an outstanding experimental challenge. In this work, we show that, following excitation with a laser wavelength of 532 nm, bulk diamond crystals doped with H3 centers both emit efficient up-conversion (anti-Stokes) photoluminescence and also show significantly reduced photothermal heating relative to crystals doped with nitrogen–vacancy (NV) centers. The H3 center in diamond is a highly photostable defect that avoids bleaching at high laser irradiances of 10–70 MW/cm 2 and has been shown to exhibit laser action, tunable over the visible band of 500–600 nm. Here, the observed reduction of photothermal heating arises due to a decrease in the concentration of absorbing point defects, including NV-centers. These results encourage future exploration of techniques for H3 enrichment in diamonds under high-pressure, high-temperature conditions for the simultaneous anti-Stokes fluorescence cooling and radiation balanced lasing in semiconductor materials. Reducing photothermal heating in diamond through the formation of H3 centers also opens up new possibilities in quantum sensing via optically detected magnetic resonance spectroscopy at ambient conditions.

42 ENGINEERING↗

BVR{sub c}I{sub c} Observations, Third-body Orbital Study, and Analysis of the UV Leo-type, Pre-W UMA Binary V642 Virginis

V642 Vir is a polar spotted, well-detached, UV Leo-type, low-mass, pre-WUMa (T1 ~ 4250K, ~K6V) eclipsing binary. It was observed in 2020 April, May, and June at the Dark Sky Observatory in North Carolina, USA with the 0.81 m reflector of Appalachian State University. A total of 88 timings were used in our 22-year period study which included 12 Transiting Exoplanet Survey Satellite (TESS) timings. The O - C plots show a low-amplitude oscillation of residuals that points to the existence of an orbiting third body, a dwarf of minimum mass, 0.15 M {sub ⊙} in an eccentric orbit (e = 0.41), with an orbital period of 20.07 yr. The odd light curves of V642 Virginis indicate that it has polar spots similar to UV Leo and the recently published V1023 Per. Its present large polar spot region indicates that it must have a strong magnetic field and that it is synchronously rotating. The BVR{sub c}I{sub c} simultaneous Wilson–Devinney Program solution gives a detached binary (primary and secondary components are underfilling their respective Roche Lobes, with 76% and 78% fill outs respectively). The cool spot region models near the pole of the primary component (centered at 10° colatitude) and is angled toward the secondary component. Its large radius (68°) and T-fact (T{sub spot}/T{sub surface} = 0.69) also attest to the conclusion of the strength of the magnetic field. The small ΔT in the components (~318 K) and mass ratio near unity (0.9542 ± 0.0005) show that the stars are similar in spectral type (secondary ~K9V). The inclination is high, ~86.87 ± 0.04°, yet there is no time of constant light due to the two stars’ essentially equal radii.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Free-Piston Expander for Hydrogen Cooling

This final report details work done by GTI Energy, in partnership with University of Texas at Austin – Center for Electromechanics (UTCEM), Argonne National Laboratory (ANL), and Quantum Fuel Solutions (Quantum) to successfully design, fabricate, and test a linear free-piston hydrogen expander controlled by linear motors which also generates electrical power during the process.

03 NATURAL GAS↗

Atmospheric River Lifecycle Responses to the Madden‐Julian Oscillation

Abstract We investigate how the Madden‐Julian Oscillation (MJO), the dominant mode of tropical subseasonal variability, modulates the lifecycle of cool‐season North Pacific atmospheric rivers (ARs). When the enhanced (suppressed) convection center is located over the Indian Ocean (western Pacific), more AR events originate over eastern Asia and with fewer over the subtropical northern Pacific. When the enhanced (suppressed) convection is over the western Pacific (Indian Ocean), the opposite changes occur, with more AR events originate over the subtropical northern Pacific and fewer over eastern Asia. Dynamical processes involving anomalous MJO wind and seasonal mean moisture are found to be the dominant factors impacting these variations in AR origins. The MJO‐related anomalous geopotential height patterns are also shown to modulate the propagation of the AR events. These MJO–AR lifecycle relationships are further supported by model simulations.

Zhou, Yang↗

Comparative Structural Rigidity Analysis of the NBSR DDE and the NBSR LEU Fuel Element

The National Bureau of Standards Reactor (NBSR) is a 20-MW heavy-water moderated and cooled, enriched-fuel, tank-type reactor located in the NIST Center for Neutron Research laboratory complex. NBSR is one of six U.S. high performance research reactors (USHPRR), including one critical facility, that actively collaborates with the National Nuclear Security Administration (NNSA) Material Management and Minimization (M3) Reactor Conversion Program to convert from the use of highly enriched uranium fuel to the use of low-enriched uranium (LEU, < 20 wt% U-235) fuel. On the LEU U-10Mo fuel qualification side, mini-plate and large-plate irradiations have been successfully performed, and more experiments are either ongoing or planned. As an additional experimental campaign to support licensing of the LEU fuel for the use in the NBSR, the NBSR Design Demonstration Element (DDE) will be a full-sized test element similar to the NBSR LEU fuel element and irradiated in a test reactor under conditions as prototypic of the NBSR LEU fuel element operating conditions as possible.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing the Heisenberg Vortex Tube for Hydrogen Cooling (Final Technical Report)

Hydrogen utilization at Plug Power sites ranges between 70-93% with the remainder vented and lost to the atmosphere. The goal of this project was to improve hydrogen utilization at Plug Power fulfillment centers via the patented Heisenberg vortex tube (HVT). The HVT combines conventional counterflow vortex tubes with para-orthohydrogen conversion catalyst to allow the cooling of hydrogen flows with no moving parts or external energy inputs. In year 1 of this project the HVT was evaluated to improve hydrogen utilization via the following concepts: 1) increasing liquid hydrogen pump volumetric efficiency by 20% through vapor separation and subcooling of the liquid, 2) reducing liquid hydrogen storage tank boil-off losses by 20% through thermal vapor shielding (TVS), and 3) increase isentropic efficiency of supercritical hydrogen expansion at 40-50 K, from 31% to over 40%. The TVS concept was selected as the most favorable application for further development. While the conceptual analysis was underway, the cryocatalysis hydrogen experiment facility (CHEF) was retrofitted with a new cryocooler, higher pressure condenser tanks, and in-situ fiber-optic Raman probes for ortho-parahydrogen composition analysis at the inlets and outlets of the HVT. To our knowledge this is the first in-situ implementation of cryogenic Raman probes for ortho-parahydrogen analysis. Subsequent testing of catalyzed and non-catalyzed HVT identified a low flow rate, high-conversion efficacy regime well suited for TVS development. Computational fluid dynamics (CFD), Reduced order modeling (ROM), and quantum Monte Carlo atomistic simulations were applied to optimize the design of the HVT implemented for TVS. The simulations and analysis identified a ruthenium-based catalyst as the most optimal for high conversion with little pressure losses and was matched to experimental measurements. These results indicated the design could achieve the 20% boil-off reduction target. An HVT field-trial was designed and constructed by Plug Power and implemented at a customer site. However, budget limitations reduced the amount of catalyst that could be applied to the HVT. With the reduced amount of catalyst, CFD analysis estimated about 3% reduction in boil-off. A similar amount of boil-off reduction was observed during preliminary measurements during tank commissioning. However, the results have a large margin for error and were operated at relatively low tank temperatures when the HVT has the lowest potential for improvement. This project demonstrated the use of para-orthohydrogen catalysis for reducing liquid hydrogen tank boil-off losses. The field trial system is anticipated to provide long-term experimental measurements on tank operational performance that will allow Plug Power to instrument additional tanks in the future. Recommendations for future work include the development of higher activity, lower cost para-orthohydrogen conversion catalyst for use in the HVT. Tank process optimizations could maximize the efficacy of the HVT and further improve hydrogen utilization.

08 HYDROGEN↗

Two-tone Doppler cooling of radial two-dimensional crystals in a radio-frequency ion trap

We study the Doppler-cooling of radial two-dimensional (2D) Coulomb crystals of trapped barium ions in a radiofrequency trap. Ions in radial 2D crystals experience micromotion of an amplitude that increases linearly with the distance from the trap center, leading to a position-dependent frequency modulation of laser light in each ion's rest frame. We use two tones of Doppler-cooling laser light separated by approximately 100 MHz to efficiently cool distinct regions in the crystals with differing amplitudes of micromotion. This technique allows us to trap and cool more than 50 ions populating 4 shells in a radial two-dimensional crystal, where with a single tone of Doppler cooling light we are limited to 30 ions in 3 shells. Here, we also individually characterize the micromotion of all ions within the crystals, and use this information to locate the center of the trap and to determine the Matthieu parameters q x and q y .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of Atmosphere and Ocean Horizontal Model Resolution on Tropical Cyclone and Upper-Ocean Response Forecasts in Four Major Hurricanes

A coupled atmosphere–ocean model is necessary for tropical cyclone (TC) prediction to accurately characterize ocean feedback on atmospheric processes within the TC environment. Here, the ECMWF coupled global model is run at horizontal resolutions from 9 to 1.4 km in the atmosphere, as well as 25 and 8 km in the ocean, to identify how resolution impacts forecast accuracy of four observed major TCs in the Atlantic: Irma, Florence, Teddy, and Ida. Most of the resolutions used here are unprecedented for global models. GOES-16 and synthetic aperture radar (SAR) satellite images and best track data are used for atmospheric validation. Salinity and temperature observations from Air-Launched Autonomous Micro-Observer (ALAMO) floats are used to validate modeled upper-ocean response, including mixed layer deepening, sea surface cooling, and near-inertial waves in the wakes of TCs. Increasing atmospheric resolution leads to more realistic TC structure and stronger winds, significantly improving TC intensity forecasts and modestly improving track errors. Ocean resolution impacts the upper-ocean response but does not influence atmospheric forecasts for the fast-moving TCs considered here. Stronger mixing, sea surface cooling, and near-inertial oscillations are found for both higher atmosphere and ocean resolutions, provided the initial upper-ocean state is the same for the two ocean resolutions. Whether this agrees better with the ALAMO observations also depends on the realism of the initial upper-ocean state in the model, emphasizing the importance of ocean initialization for the accurate upper-ocean response. Overall, the model at all resolutions correctly predicts stronger mixing, surface cooling, and near-inertial oscillation amplitudes to the right of a TC center, as observed by ALAMO floats.

Atmosphere-ocean interaction↗

Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector

This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).

15 GEOTHERMAL ENERGY↗