Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development and Experimental Evaluation of Passive Fuel Cell Thermal Control

To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.

Fuel Cells↗

High-Temperature, High-Flux Multifoil Shield Developed for Space Applications

Spacecraft employing solar dynamic power systems typically use parabolic, point focus concentrators to collect solar power and direct it to the aperture of a heat receiver. Solar fluxes several thousand times the intensity of one solar constant are typically produced in the focal plane of such concentrators. Under heat loading this severe, passively cooled surfaces constructed of most engineering materials would rapidly melt. Therefore, high-temperature shielding is required to protect heat receiver surfaces and other spacecraft surfaces that may be exposed to high flux. To meet this challenge for the joint U.S./Russian Solar Dynamic Flight Demonstration Program, AlliedSignal Aerospace and the NASA Lewis Research Center developed a high-temperature, high-flux multifoil shield tolerant of extreme heat loading conditions in a vacuum environment. The shield is passively cooled, obviating the need for pumped fluid loops and/or heat pipe cooling systems with their attendant cost, mass, complexity, and reliability issues.

Kerslake, Thomas W.↗

Reducing cold flow in elastomeric O-rings

Pretreatment technique accelerates compression set of O-rings: seal is pressure loaded; seal and pressure mechanisms are heated to 160 F; load is applied to heated seal, causing material to flow; parts are cooled to room temperature; and load is removed.

Henry, R. H.↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Control System Development for A Zero Boil-Off Hydrogen Storage Demonstration With Two-Stage Active Cooling

A NASA team is designing and building a test article to demonstrate the long duration storage of liquid hydrogen via active cooling (cryocoolers) while implementing a two-stage cooling approach. This activity is one of a large portfolio of NASA’s Space Technology Mission Directorate funded activities which focuses on the technology maturation needed for long duration storage of cryogenic liquid in-space. The current state-of-the-art for liquid hydrogen storage on-orbit is on the order of hours while NASA’s planned missions require storage for months, or even years. To enable such a long duration, Zero Boil-Off conditions must be achieved which requires passive technologies to minimize environmental heat loads, but also active cooling to intercept and reject the remaining heat to deep space. The implementation of active cooling results in a significant amount of dry mass added to the vehicle. Utilizing a Two-Stage Cooling approach, analysis and testing to date indicates the Zero Boil-Off of liquid hydrogen can be achieved with less mass and electrical power relative to a single-stage cooling approach where only one cryocooler is used. This activity will demonstrate the fully integrated suite of technologies needed to enable the Two-Stage Cooling approach which includes Multi-Layer Insulation blankets, Low Conductivity Structures, a Tube-On-Tank Heat Exchanger, Tube-On-Shield Heat Exchanger and a Two-Stage Cryogenerator (both 90 Kelvin and 20 Kelvin) with each stage having an independently controlled circulation loop. The bulk of the heat load is intercepted by the 90 Kelvin loop via a thin foil heat exchanger internal to the insulation blankets (also known as a Broad Area Cooling Shield), with the remainder removed at cryofluid temperature (20 Kelvin) by tubes directly welded to the outer tank surface. In this paper, we examine the challenges of controlling the system, and describe the development of control algorithms and software for future testing with liquid hydrogen. The interactions between the cryofans which control circulation loop mass flow rates, electrical heaters which vary the cryocooler lift to simulate the operation of variable-lift flight units, tank heaters which can vary the overall heat load, and the effects of changes in circulation loop pressure as temperatures change, can be complex and must be well understood to maintain steady-state propellant conditions and achieve Zero Boil-Off. Parallel PID loops and watchdog programs implemented on the user interface system will help bring the systems to steady state operation and keep them at selected operating points within acceptable error, while avoiding runaway feedback loops.

cryogenics↗

Summary of LO2/Ethanol OMS/RCS Technology and Advanced Development 99-2744

NASA is pursuing non-toxic propellant technologies applicable to RLV and Space Shuttle orbital maneuvering system (OMS) and reaction control system (RCS). The primary objectives of making advancements in an OMS/RCS system are improved safety, reliability, and reduced operations and maintenance cost, while meeting basic operational and performance requirements. An OMS/RCS has a high degree of direct interaction with the vehicle and crew and requires subsystem and components that are compatible with integration into the vehicle with regard to external mold-line, power, and thermal control. In July 1997, a Phase I effort for the technology and advanced development of an upgrade of the space shuttle was conducted to define the system architecture, propellant tank, feed system, RCS thrusters, and OMS engine. Phase I of the project ran from July 1997 to October 1998. Phase II is currently being planned for the development and test of full-scale prototype of the system in 1999 and 2000. The choice of pressure-fed liquid oxygen (LO2) and ethanol is the result of numerous trade studies conducted from 1980 to 1996. Liquid oxygen and ethanol are clean burning, high-density propellants that provide a high degree of commonality with other spacecraft subsystems including life support, power, and thermal control, and with future human exploration and development of space missions. The key to this pressure-fed system is the use of subcooled liquid oxygen at 350 psia. In this approach, there is 80 degrees R of subcooling, which means that boil-off will not occur until the temperature has risen 80 R. The sub-cooling results naturally from loading propellants at 163 R, which is the saturation temperature at 14.7 psia, and then pressurizing to 350 psia on the launch pad. Thermal insulation and conditioning techniques are then used to limit the LO2 temperature to 185 R maximum, and maintain the sub-cooling. The other key is the wide temperature range of ethanol, -173 F to +300 F, which can provide heat to gasify liquid oxygen or provide a good coolant.

Curtis, Leslie A.↗

NASA Blazes a Different Path to Energy-Efficient Supercomputing

For years, NASA had a very straightforward process for replacing high-performance computing hardware: over a three-year period, when it became more expensive to operate an older suite of hardware than it did to replace it with new products that could accomplish the same work, we simply replaced the old hardware. For NASA’s High-End Computing Capability (HECC) Project, that process changed when we reached the limits of our facility’s power, cooling, and floor-loading capacity, becoming a strategy of decommissioning the least productive hardware and replacing it with more capable counterparts. The impact was that we provided our users with less supercomputing capability than we would have without the limitations. Additionally, with 25% of our total power consumption going to cool our systems and 50,000 gallons of water per day being evaporated, we wanted a solution that would expand our compute facility while being sensitive to the impact on our environment.

Thigpen, William↗

Analysis and Design of the NASA Langley Cryogenic Pressure Box

A cryogenic pressure box was designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 72 in. x 60 in. curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20K) with 54 psig maximum pressure on the concave side, and elevated temperatures and atmospheric pressure on the convex surface. The internal surface of the panel is cooled by high pressure helium as that is cooled to -423 F by liquid helium heat exchangers. An array of twelve independently controlled fans circulate the high pressure gaseous helium to provide uniform cooling on the panel surface. The load introduction structure, consisting of four stainless steel load plates and numerous fingers attaching the load plates to the test panel, is designed to introduce loads into the test panel that represent stresses that will he observed in the actual tank structure. The load plates are trace cooled with liquid nitrogen to reduce thermal gradients that may result in bending the load plates, and thus additional stresses in the test panel. The design of the cryogenic systems, load introduction structure, and control system are discussed in this report.

Glass, David E.↗

Effects of Volcanic Eruptions on Stratospheric Ozone Recovery

The effects of the stratospheric sulfate aerosol layer associated with the Mt. Pinatubo volcano and future volcanic eruptions on the recovery of the ozone layer is studied with an interactive two-dimensional photochemical model. The time varying chlorine loading and the stratospheric cooling due to increasing carbon dioxide have been taken into account. The computed ozone and temperature changes associated with the Mt. Pinatubo eruption in 1991 agree well with observations. Long model runs out to the year 2050 have been carried out, in which volcanoes having the characteristics of the Mount Pinatubo volcano were erupted in the model at 10-year intervals starting in the year 2010. Compared to a non-volcanic run using background aerosol loading, transient reductions of globally averaged column ozone of 2-3 percent were computed as a result of each of these eruptions, with the ozone recovering to that computed for the non-volcanic case in about 5 years after the eruption. Computed springtime Arctic column ozone losses of from 10 to 18 percent also recovered to the non-volcanic case within 5 years. These results suggest that the long-term recovery of ozone would not be strongly affected by infrequent volcanic eruptions with a sulfur loading approximating Mt. Pinatubo. Sensitivity studies in which the Arctic lower stratosphere was forced to be 4 K and 10 K colder resulted in transient ozone losses of which also recovered to the non-volcanic case in 5 years. A case in which a volcano five times Mt. Pinatubo was erupted in the year 2010 led to maximum springtime column ozone losses of 45 percent which took 10 years to recover to the background case. Finally, in order to simulate a situation in which frequent smaller volcanic eruptions result in increasing the background sulfate loading, a simulation was made in which the background aerosol was increased by 10 percent per year. This resulted in a delay of the recovery of column ozone to 1980 values of more than 10 years.

Rosenfield, Joan E.↗

The Liquid Nitrogen System for Chamber A: A Change from Original Forced Flow Design to a Natural Flow (Thermo Siphon) System

NASA Johnson Space Center (JSC) in Houston is currently supplementing its 20K helium refrigeration system to meet the new requirements for testing the James Web Space Telescope in the environmental control Chamber-A (65 dia x 120 high) in Building 32. The new system is required to meet the various operating modes which include a high 20K heat load, a required temperature stability at the load, rapid (but controlled) cool down and warm up and bake out of the chamber. This paper will present the proposed modifications to the existing helium system(s) to incorporate the new requirements and the integration of the new helium refrigerator with the existing two 3.5KW 20K helium refrigerators. In addition, the floating pressure process control philosophy to achieve high efficiency over the operating range (40% to 100% of the refrigeration system capacity), and the required temperature stability of +/- 0.25 K at the load will be discussed. The refrigeration systems ability to naturally seek the operating conditions under various loads and thus minimizing operator involvement and the over all improvements to the system operability and the reliability will be explained.

Homan, Jonathan↗

Lunar Portable Life Support System Heat Rejection Study

Performing extravehicular activity (EVA) at various locations of the lunar surface presents thermal challenges that exceed those experienced in space flight to date. The lunar Portable Life Support System (PLSS) cooling unit must maintain thermal conditions within the space suit and reject heat loads generated by the crewmember and the PLSS equipment. The amount of cooling required varies based on the lunar location and terrain due to the heat transferred between the suit and its surroundings. A study has been completed which investigated the resources required to provide cooling under various lunar conditions, assuming three different thermal technology categories: 1. Spacesuit Water Membrane Evaporator (SWME) 2. Subcooled Phase Change Material (SPCM) 3. Radiators with and without heat pumps Results from the study are presented that show mass and power impacts on the cooling system as a function of the location and terrain on the lunar surface. Resources (cooling equipment mass and consumables) are greater at the equator and inside sunlit craters due to the additional heat loads on the cooling system. While radiator and SPCM technologies require minimal consumables, they come with carry-weight penalties and have limitations. A wider investigation is recommended to determine if these penalties and limitations are offset by the savings in consumables.

Conger, Bruce↗

Studies of shock/shock interaction on smooth and transpiration-cooled hemispherical nosetips in hypersonic flow

Experimental studies are conducted to examine the utilization of transpiration cooling to reduce the peak-heating loads in areas of shock/shock interaction. Smooth and transpiration-cooled nosetip models, 12 inches in diameter, were employed in these studies, which focused on defining the pressure distributions and heat transfer in type III and IV interaction areas. Transpiration cooling was determined to significantly increase the size of the shock layer and to move the peak-heating point around the body. A transpiration-cooling rate of more than 30 percent of the freestream maximum flux did not lower the peak-heating level more than 10 percent, but the integrated heating loads were reduced.

Holden, M. S.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 1: Summary

Numerous candidate APU concepts are considered, each meeting the space shuttle APU problem statement. Evaluation of these concepts indicates that the optimum concept is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads. A preliminary design of the selected APU concept is presented, placing primary emphasis on the cycle thermal management and the controls. Results for both steady state and transient APU performance are also included, based on digital computer programs developed during the study. The selected APU provides up to 400 hp out of the gearbox, has a fixed weight of about 277 lb, and requires about 2 lb/shp-hr of propellants.

Hamilton, M. L.↗

Thermal testing techniques for space shuttle thermal protection system panels

An experimental system was developed for evaluation of the effects of aerodynamic heating and cooling, vacuum, and pressure loading on candidate insulation packages proposed for use on the space shuttle. The system includes a number of design features which facilitate rapid recycle times. This is necessary to efficiently conduct extensive thermal cycling tests on these insulation packages to determine their reuse capabilities. The heart of the system is a 26-inch graphite element radiant heater. A susceptor plate functions as a uniform-temperature intermediate radiating surface. The susceptor also forms the lid of an inert atmosphere enclosure which separates the heater from the oxidizing test atmosphere. In some tests the plate properly simulates the heating from an actual flight heat-shield panel. Although other materials were used at lower required test temperatures, 2500 F was routinely achieved using a coated columbium susceptor plate.

Cox, B. G.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 5: Selected system cycle performance data

Detailed cycle steady-state performance data are presented for the final auxiliary power unit (APU) system configuration. The selection configuration is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads. The data are given in the form of computer printouts and provide the following: (1) verification of the adequacy of the design to meet the problem statement for steady-state performance; (2) overall system performance data for the vehicle system analyst to determine propellant consumption and hydraulic fluid temperature as a function for varying mission profiles, propellant inlet conditions, etc.; and (3) detailed component performance and cycle state point data to show what is happening in the cycle as a function of the external forcing functions.

Hamilton, M. L.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 3: Details of system analysis, engineering, and design for selected system

Numerous candidate APU concepts, each meeting the space shuttle APU problem statement are considered. Evaluation of these concepts indicates that the optimum concept is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads.

Hamilton, M. L.↗

Critical research and advanced technology (CRT) support project

A critical technology base for utility and industrial gas turbines by planning the use of coal-derived fuels was studied. Development tasks were included in the following areas: (1) Combustion - investigate the combustion of coal-derived fuels and methods to minimize the conversion of fuel-bound nitrogen to NOx; (2) materials - understand and minimize hot corrosion; (3) system studies - integrate and focus the technological efforts. A literature survey of coal-derived fuels was completed and a NOx emissions model was developed. Flametube tests of a two-stage (rich-lean) combustor defined optimum equivalence ratios for minimizing NOx emissions. Sector combustor tests demonstrated variable air control to optimize equivalence ratios over a wide load range and steam cooling of the primary zone liner. The catalytic combustion of coal-derived fuels was demonstrated. The combustion of coal-derived gases is very promising. A hot-corrosion life prediction model was formulated and verified with laboratory testing of doped fuels. Fuel additives to control sulfur corrosion were studied. The intermittent application of barium proved effective. Advanced thermal barrier coatings were developed and tested. Coating failure modes were identified and new material formulations and fabrication parameters were specified. System studies in support of the thermal barrier coating development were accomplished.

Furman, E. R.↗

The revolutionary impact of evolving aeronautical technologies

Recent advances in aeronautical technologies which could produce revolutionary changes in transport aircraft if fully implemented are delineated. Laminar flow control offers a L/D improvement from the current 18 to 22 if used with a 767 configuration. Higher aspect and thickness/chord ratios could yield more efficient structural designs and further drag reduction. High-strength, fiber-reinforced composite structures can reduce structural weight by 10-30 percent. Improved engine cooling methods, higher stage loadings and exhaust temperatures can lower the SFC by 15 percent, engine weight by 15 percent, and the parts count by 50 percent. Aft-mounted counterrotating propellers can potentially decrease the SFC an additional 15-20 percent. Supersonic transport aircraft with L/D ratios of 18 and 70 seat miles/gal fuel efficiency can now be built that weigh half as much as the Concorde and carry the same load. The new SST would have superplastic-molded Al alloy structures.

Kayten, G. G.↗