Search NASA⌕ Search

SEARCH · Search NASA

Results for “coordinated attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Numerical solution of the viscous hypersonic flow past blunted cones at angle of attack

Hypersonic viscous flow over spherically blunted cones of large half angle is computed at small angles of attack in the plane of symmetry of the flow field. Time-dependent viscous shock-layer equations in body-oriented coordinates are used to describe the flow field. The shock wave is treated as a discontinuity, across which the Rankine-Hugoniot relations are used to compute the flow conditions behind the shock. A time-marching second-order finite-difference method is used to solve the equations for a perfect gas. The local CFL (Courant-Friedrich-Lewy) time increment is used to advance the solution in time at each grid point. A fourth-order damping is used to damp the oscillations in the flow quantities. The numerical results of the present analysis for quantities such as shock standoff distance, surface-pressure distribution, and heating rates compare well with the existing theoretical and experimental results.

Kumar, A.↗

Research Strategy for Modeling the Complexities of Turbine Heat Transfer

The subject of this paper is a NASA research program, known as the Coolant Flow Management Program, which focuses on the interaction between the internal coolant channel and the external film cooling of a turbine blade and/or vane in an aircraft gas turbine engine. The turbine gas path is really a very complex flow field. The combination of strong pressure gradients, abrupt geometry changes and intersecting surfaces, viscous forces, rotation, and unsteady blade/vane interactions all combine to offer a formidable challenge. To this, in the high pressure turbine, we add the necessity of film cooling. The ultimate goal of the turbine designer is to maintain or increase the high level of turbine performance and at the same time reduce the amount of coolant flow needed to achieve this end. Simply stated, coolant flow is a penalty on the cycle and reduces engine thermal efficiency. Accordingly, understanding the flow field and heat transfer associated with the coolant flow is a priority goal. It is important to understand both the film cooling and the internal coolant flow, particularly their interaction. Thus, the motivation for the Coolant Flow Management Program. The paper will begin with a brief discussion of the management and research strategy, will then proceed to discuss the current attack from the internal coolant side, and will conclude by looking at the film cooling effort - at all times keeping sight of the primary goal the interaction between the two. One of the themes of this paper is that complex heat transfer problems of this nature cannot be attacked by single researchers or even groups of researchers, each working alone. It truly needs the combined efforts of a well-coordinated team to make an impact. It is important to note that this is a government/industry/university team effort.

Simoneau, Robert J.↗

The Blunt Plate In Hypersonic Flow

The sonic-wedge characteristics method has been used to obtain the shock shapes and surface pressure distributions on several blunt two-dimensional shapes in a hypersonic stream for several values of the ratio of specific heats. These shapes include the blunt slab at angle of attack and power profiles of the form yb = a)P, where 0 les than m less than 1, Yb and x are coordinates of the body surface, and a is a constant. These numerical results have been compared with the results of blast-wave theory, and methods of predicting the pressure distributions and shock shapes are proposed in each case. The effects of a free-stream conical-flow gradient on the pressure distribution on a blunt slab in hypersonic flow were investigated by the sonic-wedge characteristics method and were found to be sizable in many cases. Procedures which are satisfactory for reducing pressure data obtained in conical flows with small gradients are presented.

Baradell, Donald L.↗

Comparison of X-31 flight, wind-tunnel, and water-tunnel yawing moment asymmetries at high angles of attack

The X-31 aircraft are being used in the enhanced fighter maneuverability (EFM) research program, which is jointly funded by the (U.S.) Advanced Research Projects Agency (ARPA) and Germany's Federal Ministry of Defense (FMOD). The flight test portion of the program, which involves two aircraft, is being conducted by an International Test Organization (ITO) comprising the National Aeronautics and Space Administration (NASA), the U.S. Navy, the U.S. Air Force, Rockwell International, and Deutsche Aerospace (DASA). The goals of the flight program are to demonstrate EFM technologies, investigate close-in-combat exchange ratios, develop design requirements, build a database for application to future fighter aircraft, and develop and validate low-cost prototype concepts. For longitudinal control the X-31 uses canards, symmetrical movement of the trailing-edge flaps, and pitch deflection of the thrust vectoring system. The trim, inertial coupling, and engine gyroscopic coupling compensation tasks are performed primarily by the trailing-edge flaps. For lateral-directional control the aircraft uses differential deflection of the trailing-edge flaps for roll coordination and a conventional rudder combined with the thrust vectoring system to provide yaw control. The rudder is only effective up to about 40 deg angle of attack (alpha), after which the thrust vectoring becomes the primary yaw control effector. Both the leading-edge flaps and the inlet lip are scheduled with the angle of attack to provide best performance.

Brent R Cobleigh↗

Under Attack

Diversified High Technologies, Inc. (DHT) has supported the Avionics Software Development Environment Pathfinder (ASDEP) program throughout its phases. For the first two years, DHT operated as the technology facilitator providing technical coordination between vendors, contractors, and NASA. This evolved to hands-on technical support such as systems installation, upgrades, and integration. DHT has recently been providing support in secure technology migration path planning and the incorporation of new security technologies in response to evolving program requirements.

Source record↗

Developing a Regional Recovery Framework

Abstract A biological attack would present an unprecedented challenge for local, state, and federal agencies; the military; the private sector; and individuals on many fronts ranging from vaccination and treatment to prioritization of cleanup actions to waste disposal. To prepare the Seattle region to recover from a biological attack, the Seattle Urban Area Security Initiative (UASI) partners collaborated with military and federal agencies to develop a Regional Recovery Framework for a Biological Attack in the Seattle Urban Area. The goal was to reduce the time and resources required to recover and restore wide urban areas, military installations, and other critical infrastructure following a biological incident by providing a coordinated systems approach. Based on discussions in small workshops, tabletop exercises, and interviews with emergency response agency staff, the partners identified concepts of operation for various areas to address critical issues the region will face as recovery progresses. Key to this recovery is the recovery of the economy. Although the Framework is specific to a catastrophic, wide-area biological attack using anthrax, it was designed to be flexible and scalable so it could also serve as the recovery framework for an all-hazards approach. The Framework also served to coalesce policy questions that must be addressed for long-term recovery. These questions cover such areas as safety and health, security, financial management, waste management, legal issues, and economic development.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

An approximate method for calculating heating rates on three-dimensional vehicles

An approximate method for calculating heating rates on three-dimensional vehicles at angle of attack is presented. The method is based on the axisymmetric analog for three-dimensional boundary layers and uses a generalized body fitted coordinate system. Edge conditions for the boundary layer solution are obtained from an inviscid flowfield solution, and because of the coordinate system used the method is applicable to any blunt body geometry for which a inviscid flowfield solution can be obtained. It is validated by comparing with experimental heating data and with Navier-Stokes calculations on the Shuttle orbiter at both wind tunnel and flight conditions and with Navier-Stokes calculations on the HL-20 at wind tunnel conditions.

Hamilton, H. H., II↗

Differential Canard deflection for generation of yawing moment on the X-31 with and without the vertical tail

The feasibility of augmenting the available yaw control power on the X-31 through differential deflection of the canard surfaces was studied as well as the possibility of using differential canard control to stabilize the X-31 with its vertical tail removed. Wind-tunnel tests and the results of departure criteria and linear analysis showed the destabilizing effect of the reduction of the vertical tail on the X-31. Wind-tunnel testing also showed that differential canard deflection was capable of generating yawing moments of roughly the same magnitude as the thrust vectoring vanes currently in place on the X-31 in the post-stall regime. Analysis showed that the X-31 has sufficient aileron roll control power that with the addition of differential canard as a yaw controller, the wind-axis roll accelerations will remain limited by yaw control authority. It was demonstrated, however, that pitch authority may actually limit the maximum roll rate which can be sustained. A drop model flight test demonstrated that coordinated, wind axis rolls could be performed with roll rates as high as 50 deg/sec (full scale equivalent) at 50 deg angle of attack. Another drop model test was conducted to assess the effect of vertical tail reduction, and an analysis of using differential canard deflection to stabilize the tailless X-31 was performed. The results of six-degree-of-freedom, non-linear simulation tests were correlated with the drop model flights. Simulation studies then showed that the tailless X-31 could be controlled at angles of attack at or above 20 deg using differential canard as the only yaw controller.

Whiting, Matthew Robert↗

Approximate method for calculating heating rates on three-dimensional vehicles

An approximate method for calculating heating rates on three-dimensional vehicles at angle of attack is presented. The method is based on the axisymmetric analog for three-dimensional boundary layers and uses a generalized body-fitted coordinate system. Edge conditions for the boundary-layer solution are obtained from an inviscid flowfield solution, and because of the coordinate system used, the method is applicable to any blunt body geometry for which an inviscid flowfield solution can be obtained. The method is validated by comparing with experimental heating data and with thin-layer Navier-Stokes calculations on the shuttle orbiter at both wind-tunnel and flight conditions and with thin-layer Navier-Stokes calculations on the HL-20 at wind-tunnel conditions.

Hamilton, H. Harris↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determination of the Basic Parameters of Impact Interaction of Abrasive Particles Against the Blades of the Rotor Accelerator of a Centrifugal Mill

Ways to improve the efficiency with which materials are pulverized in impact centrifugal mills as well as ways of preventing wear of the blades are proposed. The problem is solved using equations that describe the motion of particles on the surface of the rotor in a polar coordinate system. It is discovered that the rate of impact of the particles against a blade increases linearly with increasing angular velocity. The angle of attack and radius of contact of a particle with the blade are independent of this velocity, though they are substantially affected by the initial position of the particles. The nature of the variation of the rate of impact and the angle of attack is determined, based on which possible wear of the blades may be predicted and measures taken to reduce wear.

42 ENGINEERING↗

Coordination and Convening of the 2016 Arctic Science Summit Week

The Arctic Science Summit Week, Arctic Observing Summit, Arctic Council Senior Arctic Officials, Model Arctic Council, and International Arctic Assembly were convened on the campus of the University of Alaska Fairbanks with great productivity and satisfaction of the participants. We were pleased to welcome over 1000 participants from 30 different nations and over 130 different institutions. The organization and execution of these meetings was extensive and complex involving more than 250 coordinators, volunteers and contributors from across Alaska. The participants were enthusiastic in their praise of the content and accomplishments of the meeting, but they were equally happy about the genuine welcome offered to our guests by the people of Alaska. Hosting a complex event such as this summit required an army of supporting services and we were blessed to have volunteers from Fairbanks, North Pole, Anchorage and other communities throughout Alaska helping us meet these needs. This truly was an event hosted by the people of Alaska. The significance of these events cannot be overstated. The US and global communities are finally coming to the realization of the important role that the Arctic plays in international politics, economics, and science. The Arctic has experienced tremendous changes in recent years, offering new opportunities that may be addressed through international collaborations, and serious challenges that must be addressed through active investment, adaptation and national and international coordination. Over 10% of the meeting participants were indigenous peoples, from indigenous organizations or hailed from small remote communities. This is still lower than we had hoped, but it is greater participation than similar meetings have experienced in the past. It is through such engagement that we can attack problems related to the changing environment, stagnant economies, and social ills.

42 ENGINEERING↗

A high Reynolds number numerical solution of the Navier-Stokes equations in stream function-vorticity form

Problems encoutered in investigations of high Reynolds number, incompressible flow are reviewed. A numerical solution computer program was modified to solve the stream function-vorticity form of the Navier-Stokes equations. Using a body fitted coordinate system with a U-shaped outer boundary, a simulation of incompressible flow at a Reynolds number of one million and a body angle of attack of zero was achieved.

Bearden, J. H.↗

Rhodium Bis(quinolinyl)benzene Complexes for Methane Activation and Functionalization

A series of rhodium (III) bis(quinolinyl)benzene (bisq x ) complexes was researched as candidates for the homogeneous partial oxidation of methane. Density functional theory (DFT) (M06 with Poisson continuum solvation) was used to investigate a variety of (bisq x ) ligand candidates involving different functional groups to determine the impact on RhIII(bisq x ) catalyzed methane functionalization. The free energy activation barriers for methane C–H activation and Rh–methyl functionalization at 298 K and 498 K were determined. DFT studies predict that the best candidate for catalytic methane functionalization is Rh III coordinated to unsubstituted bis(quinolinyl)benzene (bisq). Support is also found for the prediction that the η 2 -benzene coordination mode of (bisq x ) ligands on Rh encourages methyl group functionalization by serving as an effective leaving group for S N 2 and S R 2 attack.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Convair 990 transonic flow-field simulation about the forward fuselage

A three-dimensional, viscous flow code was used to calculate the transonic flow about the forebody of the Convair CV-990 (Galileo II) research aircraft stationed at NASA Ames Research Center. The computations were used to determine the location for a differential pressure system. In addition, attitude sensor placements were verified. These instruments comprise a meteorological measurement system, which will be used for global determination of three-dimensional wind data. The code solves the thin layer form of the Reynolds-averaged Navier-Stokes equations using an implicit numerical procedure. The governing equations are written in a generalized, nonorthogonal coordinate system, and are cast in a strong conservation law form. Laminar boundary layer results are presented for free stream Mach number of 0.8 and angles of attack of zero and 2 deg. Use of this computational tool reduced the development time for the location of the sensors and aided in the optimal placement on the aircraft of these devices.

Chaussee, D. S.↗

A technique for the prediction of airfoil flutter characteristics in separated flow

A solution procedure is described for determining the two-dimensional, one- or two-degree-of-freedom flutter characteristics of arbitrary airfoils at large angles of attack. The same procedure is used to predict stall flutter. This procedure requires a simultaneous integration in time of the solid and fluid equations of motion. The fluid equations of motion are the unsteady compressible Navier-Stokes equations, solved in a body-fitted moving coordinate system using an approximate factorization scheme. The solid equations of motion are integrated in time using an Euler implicit scheme. Flutter is said to occur if small disturbances imposed on the airfoil attitude lead to divergent oscillatory motions at subsequent times. Results for a number of special cases are presented to demonstrate the suitability of this scheme to predict flutter at large mean angles of attack. Some stall flutter applications are also presented.

Wu, Jiunn-Chi↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical observations on the aerodynamics of a delta wing with leading edge flaps

The effect of a leading edge flap on the aerodynamics of a low aspect ratio delta wing is studied analytically. The separated flow field about the wing is represented by a simple vortex model composed of a conical straight vortex sheet and a concentrated vortex. The analysis is carried out in the cross flow plane by mapping the wing trace, by means of the Schwarz-Christoffel transformation into the real axis of the transformed plane. Particular attention is given to the influence of the angle of attack and flap deflection angle on lift and drag forces. Both lift and drag decrease with flap deflection, while the lift-to-drag ratioe increases. A simple coordinate transformation is used to obtain a closed form expression for the lift-to-drag ratio as a function of flap deflection. The main effect of leading edge flap deflection is a partial suppression of the separated flow on the leeside of the wing. Qualitative comparison with experiments is presented, showing agreement in the general trends.

Oh, S.↗