Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Distribution and Abundance of Bird Species: Towards a Satellite, Data Driven Avian Energetics and Species Richness Model

This paper addresses the fundamental question of why birds occur where and when they do, i.e., what are the causative factors that determine the spatio-temporal distributions, abundance, or richness of bird species? In this paper we outline the first steps toward building a satellite, data-driven model of avian energetics and species richness based on individual bird physiology, morphology, and interaction with the spatio-temporal habitat. To evaluate our model, we will use the North American Breeding Bird Survey and Christmas Bird Count data for species richness, wintering and breeding range. Long term and current satellite data series include AVHRR, Landsat, and MODIS.

Smith, James A.↗

Estimation of uncertainties for subcritical benchmark measurements - 14387

Subcritical measurements are used for many applications including nonproliferation, treaty verification, in-situ monitoring for criticality, and reactor subcriticality monitoring. Most analysis methods involve correlated neutron detection, based upon the property that fission events can create multiple neutrons that are born at nearly the same time (on a scale of 10{sup -13} or 10{sup -14} seconds). Many different time-correlated methods have been used since the 1950's and are still widely utilized today. This particular work describes an uncertainty analysis of measured data using the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. The Feynman Variance-to-Mean method was introduced by Feynman et al. in 1956 and is based upon the differences between the detector count data and the data that would be expected from measurements taken from a Poissonian source. The Hage-Cifarelli formalism relates moments of the Feynman histograms to several parameters of a system: leakage multiplication (M{sub L}), spontaneous fission rate (F{sub S}), (α,n) neutron emission rate (S{sub α}), detector efficiency (ε), and the moments of the number of neutrons emitted per fission (ν). The first part of the uncertainty method described in this work will show how to determine uncertainties of the first (R{sub 1}) and second (R{sub 2}) reduced factorial moments of the Feynman histograms. The second part of the method will describe how to determine the uncertainties in the other parameters given uncertainties in the reduced factorial moments; in particular, this work will focus on determining the uncertainties in M{sub L} and F{sub S}. This work will utilize measured data from a recent benchmark evaluation with a 4.5 kg sphere of α-phase plutonium to validate the uncertainty analysis. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Generalized Canonical Polyadic Tensor Decomposition

Tensor decomposition is a fundamental unsupervised machine learning method in data science, with applications including network analysis and sensor data processing. This work develops a generalized canonical polyadic (GCP) low-rank tensor decomposition that allows other loss functions besides squared error. For instance, we can use logistic loss or Kullback--Leibler divergence, enabling tensor decomposition for binary or count data. We present a variety of statistically motivated loss functions for various scenarios. We provide a generalized framework for computing gradients and handling missing data that enables the use of standard optimization methods for fitting the model. Furthermore, we demonstrate the flexibility of the GCP decomposition on several real-world examples including interactions in a social network, neural activity in a mouse, and monthly rainfall measurements in India.

97 MATHEMATICS AND COMPUTING↗

Geochemical Mapping of 4 Vesta Begins

By December, the NASA Dawn spacecraft will have descended to a low altitude mapping orbit (LAMO), where the Gamma Ray and Neutron Detector (GRaND) will acquire global mapping data for up to four months. Measurements by GRaND will help answer elusive questions about how Vesta differentiated and the nature of processes that shaped Vesta s surface. The data will be analyzed to determine the abundances of Mg, Si, Fe, K, Th, and H at a spatial resolution of roughly 300 km full-width-at-half-maximum from a 465 km radius orbit. Thermal and fast neutron counting data will be analyzed to determine the neutron macroscopic absorption cross section and average atomic mass, providing constraints on additional elements, such as Ca and Al. GRaND will quantify the elemental composition of coarse spatial units identified by Dawn s Framing Camera (FC) and the Visible & Infrared Spectrometer (VIR). In addition, GRaND will map the mixing ratio of compositional end members selected from the howardite, eucrite and diogenite (HED) meteorites, determine the relative proportions of plagioclase and mafic minerals, and search for compositions that are absent or under-represented in the meteorite collection. While it is generally thought that Vesta s crust on a regional scale should be well-represented by linear mixing of HED whole-rock compositions, there are hints that Vesta may be more diverse than implied by this model. For example, the discovery of K-rich impact glasses in howardites suggests that K-rich rocks may be present on a portion of Vesta s surface, and the analysis of diogenites indicates considerable variability in the magmatic processes that formed them. The chemical composition of materials within Vesta s south polar structure may provide further clues to how it formed. An impact might have exposed mantle and lower crustal materials, which should have a distinctive compositional signature. We present the analysis of data acquired by GRaND from cruise through the descent to LAMO, including GRaND s sensitivity to different elements and geochemical processes.

Prettyman, Thomas H.↗

Mid-Latitude Composition of Mars from Thermal and Epithermal Neutrons

Epithermal neutron data acquired by Mars Odyssey have been analyzed to determine global maps of water-equivalent hydrogen abundance. By assuming that hydrogen was distributed uniformly with depth within the surface, a map of minimum water abundance was obtained. The addition of thermal neutrons to this analysis could provide information needed to determine water stratigraphy. For example, thermal and epithermal neutrons have been used together to determine the depth and abundance of water-equivalent hydrogen of a buried layer in the south polar region. Because the emission of thermal neutrons from the Martian surface is sensitive to absorption by elements other than hydrogen, analysis of stratigraphy requires that the abundance of these elements be known. For example, recently published studies of the south polar region assumed that the Mars Pathfinder mean soil composition is representative of the regional soil composition. This assumption is partially motivated by the fact that Mars appears to have a well-mixed global dust cover and that the Pathfinder soil composition is representative of the mean composition of the Martian surface. In this study, we have analyzed thermal and epithermal neutron data measured by the neutron spectrometer subsystem of the gamma ray spectrometer to determine the spatial distribution of the composition of elements other than hydrogen. We have restricted our analysis to mid-latitude regions for which we have corrected the neutron counting data for variations in atmospheric thickness.

T H Prettyman↗

A Prescription for List-Mode Data Processing Conventions

There are a variety of algorithmic approaches available to process list-mode pulse streams to produce multiplicity histograms for subsequent analysis. In the development of the INCC v6.0 code to include the processing of this data format, we have noted inconsistencies in the “processed time” between the various approaches. The processed time, tp, is the time interval over which the recorded pulses are analyzed to construct multiplicity histograms. This is the time interval that is used to convert measured counts into count rates. The observed inconsistencies in tp impact the reported count rate information and the determination of the error-values associated with the derived singles, doubles, and triples counting rates. This issue is particularly important in low count-rate environments. In this report we will present a prescription for the processing of list-mode counting data that produces values that are both correct and consistent with traditional shift-register technologies. It is our objective to define conventions for list mode data processing to ensure that the results are physically valid and numerically aligned with the results from shift-register electronics.

List mode↗

Forecasting the 2013–2014 influenza season using Wikipedia

Infectious diseases are one of the leading causes of morbidity and mortality around the world; thus, forecasting their impact is crucial for planning an effective response strategy. According to the Centers for Disease Control and Prevention (CDC), seasonal influenza affects 5% to 20% of the U.S. population and causes major economic impacts resulting from hospitalization and absenteeism. Understanding influenza dynamics and forecasting its impact is fundamental for developing prevention and mitigation strategies. We combine modern data assimilation methods with Wikipedia access logs and CDC influenza-like illness (ILI) reports to create a weekly forecast for seasonal influenza. The methods are applied to the 2013-2014 influenza season but are sufficiently general to forecast any disease outbreak, given incidence or case count data. We adjust the initialization and parametrization of a disease model and show that this allows us to determine systematic model bias. In addition, we provide a way to determine where the model diverges from observation and evaluate forecast accuracy. Wikipedia article access logs are shown to be highly correlated with historical ILI records and allow for accurate prediction of ILI data several weeks before it becomes available. The results show that prior to the peak of the flu season, our forecasting method produced 50% and 95% credible intervals for the 2013-2014 ILI observations that contained the actual observations for most weeks in the forecast. However, since our model does not account for re-infection or multiple strains of influenza, the tail of the epidemic is not predicted well after the peak of flu season has passed.

59 BASIC BIOLOGICAL SCIENCES↗

Mobile platform for radiological characterization of sites under or after decommissioning - 15139

Nowadays, nuclear industry is facing a crucial need in establishing radiological characterization for the assessment and the monitoring of any remediation work. Regarding its experience in this domain, the French Commission for Atomic Energy and Alternative Energies (CEA) of Fontenay-aux-Roses, established an important feedback and developed a sound methodology for radiological characterization. A clean-up project is managed from the initial surface characterization to the final one, once volumes of contaminated soil have been removed. Samples are collected via recognized methods and data is gathered by real-time acquisition with different conveyance such as all-in-vehicles, cart, walking, helicopter or drone. Accurate radiological analyses are performed on site thanks to the mobile laboratories cluster, called SMaRT. It enables to realize long-time gamma spectroscopy, chemical preparation for alpha spectroscopy or beta liquid scintillation counting. Data is processed with geo-statistics via the software Kartotrak, 2D or 3D mapping are created with the associated uncertainty and probability map. Drilling profiles with geological data (layers composition, particles size, etc.) are studied in order to understand the behavior of the contamination in depth. Source term, contaminated volumes and sanitary impact are calculated in order to determine the optimum excavation depth. Finally, data is stored in an online site that insures the traceability of the whole process. This just-in-time production model allows a fast response and control of costs and avoids the disadvantages of radioactive material transport. This whole innovative process, developed inside the mobile platform, requires all these tools that have been used in France and continuously evolving for more than 10 years thanks to a learning organization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shot-noise-induced lower temperature limit of the nonneutral plasma parallel temperature diagnostic

Abstract We develop a new algorithm to estimate the temperature of a nonneutral plasma in a Penning-Malmberg trap. The algorithm analyzes data obtained by slowly lowering a voltage that confines one end of the plasma and collecting escaping charges, and is a maximum likelihood estimator based on a physically-motivated model of the escape protocol presented in (Beck in Measurement of the magnetic and temperature dependence of the electron-electron anisotropic temperature relaxation rate. PhD thesis, 1990). Significantly, our algorithm may be used on single-count data, allowing for improved fits with low numbers of escaping electrons. This is important for low-temperature plasmas such as those used in antihydrogen trapping. We perform a Monte Carlo simulation of our algorithm, and assess its robustness to intrinsic shot noise and external noise. The assumptions in this paper allow for a lower bound for measurable plasma temperatures of approximately $3\,\mathrm{K}$ 3 K for plasmas of length $1\,\mathrm{cm}$ 1 cm , with approximately 100 particle counts needed for an accuracy of $\pm 10 \%$ ± 10 % .

Zhong, Adrianne (ORCID:0000000162618736)↗

Limited-angle effect compensation for respiratory binned cardiac SPECT

Purpose: In cardiac single photon emission computed tomography (SPECT), respiratory-binned study is used to combat the motion blur associated with respiratory motion. However, owing to the variability in respiratory patterns during data acquisition, the acquired data counts can vary significantly both among respiratory bins and among projection angles within individual bins. If not properly accounted for, such variation could lead to artifacts similar to limited-angle effect in image reconstruction. In this work, the authors aim to investigate several reconstruction strategies for compensating the limited-angle effect in respiratory binned data for the purpose of reducing the image artifacts. Methods: The authors first consider a model based correction approach, in which the variation in acquisition time is directly incorporated into the imaging model, such that the data statistics are accurately described among both the projection angles and respiratory bins. Afterward, the authors consider an approximation approach, in which the acquired data are rescaled to accommodate the variation in acquisition time among different projection angles while the imaging model is kept unchanged. In addition, the authors also consider the use of a smoothing prior in reconstruction for suppressing the artifacts associated with limited-angle effect. In our evaluation study, the authors first used Monte Carlo simulated imaging with 4D NCAT phantom wherein the ground truth is known for quantitative comparison. The authors evaluated the accuracy of the reconstructed myocardium using a number of metrics, including regional and overall accuracy of the myocardium, uniformity and spatial resolution of the left ventricle (LV) wall, and detectability of perfusion defect using a channelized Hotelling observer. As a preliminary demonstration, the authors also tested the different approaches on five sets of clinical acquisitions. Results: The quantitative evaluation results show that the three compensation methods could all, but to different extents, reduce the reconstruction artifacts over no compensation. In particular, the model based approach reduced the mean-squared-error of the reconstructed myocardium by as much as 40%. Compared to the approach of data rescaling, the model based approach further improved both the overall and regional accuracy of the myocardium; it also further improved the lesion detectability and the uniformity of the LV wall. When ML reconstruction was used, the model based approach was notably more effective for improving the LV wall; when MAP reconstruction was used, the smoothing prior could reduce the noise level and artifacts with little or no increase in bias, but at the cost of a slight resolution loss of the LV wall. The improvements in image quality by the different compensation methods were also observed in the clinical acquisitions. Conclusions: Compensating for the uneven distribution of acquisition time among both projection angles and respiratory bins can effectively reduce the limited-angle artifacts in respiratory-binned cardiac SPECT reconstruction. Direct incorporation of the time variation into the imaging model together with a smoothing prior in reconstruction can lead to the most improvement in the accuracy of the reconstructed myocardium.

60 APPLIED LIFE SCIENCES↗

Analyzing task-based user study data to determine colormap efficiency

Domain scientists need colormaps to visualize their data and are especially useful for identifying areas of interest, like in ocean data to identify eddies or characterize currents. However, traditional Rainbow colormap performs poorly for understanding details, because of the small perceptual range. In order to assist domain scientists in recognizing and identifying important details in their data, different colormaps need to be applied to allow higher perceptual definition. Visual artist Francesca Samsel used her understanding of color theory to create new colormaps to improve perception. While domain scientists find the new colormaps to be useful, we implemented a rigorous and quantitative study to determine whether or not the new colormaps have perceptually more colors. Color count data from one of these studies will be analyzed in depth in order to determine whether or not the new colormaps have more perceivable colors and what affects the number of perceivable colors.

97 MATHEMATICS AND COMPUTING↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The number-intensity distribution for extragalactic X-ray sources

It is shown that a self-consistent assessment of source count data can be made, if many of the deep survey sources are QSOs which are known to be evolving strongly at fluxes comparable to the survey limits. The QSO contribution would in this case become significant at X-ray fluxes below 10 to the -12th erg/sq cm per sec, and dominates at fluxes below 10 to the -13th erg/sq cm per sec. The X-ray background intensity places a limit on total source counts and requires a turnover in the evolution of X-ray emitting sources. Sources detected in the Einstein survey account for over 35% of the 1-3 keV background flux, suggesting that most of the background is due to discrete sources.

Murray, S. S.↗

Practical guide to understanding goodness-of-fit metrics used in chemical state modeling of x-ray photoelectron spectroscopy data by synthetic line shapes using nylon as an example

Chemical state analysis of a sample surface through fitting bell-shaped curves to x-ray photoelectron spectroscopic polymer data is reviewed using nylon to introduce and discuss aspects of data analysis. Different strategies for modeling chemistry in nylon spectra are presented and in so doing, a case is made to include in published science the design logic and implementation in terms of line shapes and optimization parameter constraints between components in a peak model. Imperfections in line shape relative to the true shape for photoemission lines, when compensated for using constraints to optimization parameters, are shown to provide chemical state information about a sample that justify, for peak models constructed with these limitations, metrics for goodness-of-fit different from those expected for pulse-counted data.

Materials Science↗

eDNAjoint: An R package for interpreting paired or semi‐paired environmental DNA and traditional survey data in a Bayesian framework

Abstract Environmental DNA (eDNA) sampling is increasingly used in surveys of species distribution as a potentially sensitive and efficient monitoring method. Yet access to modelling tools designed specifically for interpreting this new data type lags behind its ubiquity. While occupancy modelling software has dominated the analytical landscape for eDNA data analysis of single species, this type of model may not always be the most appropriate. The rate of eDNA detection often corresponds to species density, rather than just occupancy, and researchers often have access to observations from non‐genetic sampling methods at the same sites. To provide users access to a modelling framework designed to maximize the use of all available data, we developed an R package, eDNAjoint . The package provides an easy‐to‐use interface for fitting a ‘joint’ model that integrates data from paired or semi‐paired eDNA and traditional surveys in a Bayesian framework. The model can be used to estimate parameters like the probability of a false positive eDNA detection and mean catch rate at a site, and the package allows access to multiple model variations and Bayesian prior customization. Additional functionality can be used for model selection, summarising posteriors and comparing the relative sensitivities of the two survey methods. We demonstrate the use of eDNAjoint by fitting a variation of the model with site‐level covariates that scale the sensitivity of eDNA sampling relative to traditional sampling. The example workflow uses binary eDNA and seine count data for the endangered tidewater goby ( Eucyclogobius newberryi ) from a study by Schmelzle and Kinziger (2016). This use case includes a prior sensitivity analysis and an evaluation of the relationship between detection rates and environmental variables. eDNAjoint has the potential to greatly increase the range of users who will be able to rigorously analyse eDNA and traditional survey data in a Bayesian framework, understand if and how eDNA can improve monitoring practices, and gain confidence in the interpretability of eDNA data.

Keller, Abigail G. [Department of Environment Scie↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutrophil to Lymphocyte Ratio: A Prognostic Indicator for Astronaut Health

Short-term and long-term spaceflight missions can cause immune system dysfunction in astronauts. Recent studies indicate elevated white blood cells (WBC) and polymorphonuclear neutrophils (PMN) in astronaut blood, along with unchanged or reduced lymphocyte counts, and reduced T cell function, during short-(days) and long-(months) term spaceflight. A high PMN to lymphocyte ratio (NLR) can acts as a strong predictor of poor prognosis in cancer, and as a biomarker for subclinical inflammation in humans and chronic stress in mouse models, however, the NLR has not yet been identified as a predictor of astronaut health during spaceflight. For this, complete blood cell count data collected from astronauts and rodents that have flown for short- and long-term missions on board the International Space Station (ISS) was repurposed to determine the NLR pre-, in-, and post-flight. The results displayed that the NLR progressively increased during spaceflight in both human and mice, while a spike in the NLR was observed at post-flight landing, suggesting stress-induced factors may be involved. In addition, the ground-based chronic microgravity analog, hindlimb unloading in mice, indicated an increased NLR, along with induced myeloperoxidase expression, as measured by quantitative (q)PCR. The mechanism for increased NLR was further assessed in vitro using the NASA-developed rotating wall vessel (RWV) cell culture suspension system with human WBCs. The results indicated that simulated microgravity led to increased mature PMN counts, NLR profiles, and production of reactive oxygen species (ROS). Collectively, these studies show that an increased NLR is observed in spaceflight missions, and in chronic microgravity-analog simulation in mice, and that this effect may be potentiated by the oxidative stress response in blood cells under microgravity conditions. Furthermore, these results suggest that a disrupted NLR profile in spaceflight may further disrupt immune homeostasis, potentially causing chronic immune-mediated inflammatory diseases. Thus, we propose that the health status of astronauts during short- and long-term space missions can be monitored by their NLR profile, in addition to utilizing this measurement as a tool for interventions and countermeasure development to restore homeostatic immunity.

biomarker↗