Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cryo-Cooled Sapphire Oscillator for the Cassini Ka-Band Experiment

We present features for an ultra-stable sapphire cryogenic oscillator which has been designed to support the Cassini Ka-band Radio Science experiment. The design of this standard is new in several respects. It is cooled by a commercial cryocooler instead of liquid cryogens to increase operating time, and it uses a technology to adjust the temperature turn-over point to extend the upper operating temperature limit and to enable construction of multiple units with uniform operating characteristics. Objectives are 3 x 10(exp -15) stability for measuring times 1 second less than or equal to (tau) less than or equal to 100 seconds, phase noise of -85 dBc/Hz from offset frequencies of 1 Hz to 1000 Hz at 10 GHz carrier frequency, and a one year continuous operating period.

Wang, Rabi T.↗

Cryo-Trapping the Distorted Octahedral Reaction Intermediate of Manganese Superoxide Dismutase

Superoxide dismutase protects organisms from potentially damaging oxygen radicals by catalyzing the disproportion of superoxide to oxygen and hydrogen peroxide. We report the use of cryogenic temperatures to kinetically trap the 6th ligand bound to the active site of manganese superoxide dismutase. Using cryocrystallography and synchrotron radiation, we describe at 1.55A resolution the six-coordinate, distorted octahedral geometry assumed by the active site during catalysis and compare it to the room temperature, five-coordinate trigonal-bipyramidal active site. Gateway residues Tyr34, His30 and a tightly bound water molecule are implicated in closing off the active site and blocking the escape route of superoxide during dismutation.

Borgstahl, Gloria↗

Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.

Dick, G. John↗

Cryo-Transmittance and -Reflectance of Filters and Beamsplitters for the SIRTF Infrared Array Camera

The Space Infrared Telescope Facility (SIRTF) Infrared Array Camera (IRAC) uses two dichroic beamsplitters, four bandpass filters, and four detector arrays to acquire images in four channels at wavelengths between 3 and 10 micron. Accurate knowledge of the pass bands is necessary because, in order to meet the science objectives, IRAC is required to do 2% relative photometry in each band relative to the other bands. We report the in-band and out-of-band polarized transmittance and reflectance of these optical elements measured near the instrument operating temperature of 1.4 K. Details of the experimental apparatus, which include a continuous flow liquid helium optical cryostat and a Fourier transform infrared (FTIR) spectrometer are discussed.

Stewart, Kenneth P.↗

Cryo-Trapping the Distorted Octahedral Reaction Intermediate of Manganese Superoxide Dismutase

Superoxide dismutase protects organisms from potentially damaging oxygen radicals by catalyzing the disproportion of superoxide to oxygen and hydrogen peroxide. We report the use of cryogenic temperatures to kinetically trap the 6th ligand bound to the active site of manganese superoxide dismutase. Using cryocrystallography and synchrotron radiation, we describe at 1.55A resolution the six-coordinate, distorted octahedral geometry assumed by the active site during catalysis and compare it to the room temperature, five-coordinate trigonal-bipyramidal active site. Gateway residues Tyr34, His30 and a tightly bound water molecule are implicated in closing off the active site and blocking the escape route of superoxide during dismutation.

Borgstahl, Gloria↗

AMSD Cryo Actuator Testing

The actuator technology required for AMSD and subsequently NGST are critical in the successful development for future cryogenic systems. Kodak has undertaken an extensive test plan to determine the performance of the force actuators developed under the AMSD program. These actuators are currently in testing at MSFC and are expected to finish this test cycle in early June 2002.

Mullette, Mark↗

Relocation of the Cryo-Test Facility to NASA-MSFC

The Environmental Test Facility (ETF), located at NASA-Marshall Space Flight Center, Huntsville, Alabama, has provided thermal vacuum testing for several major programs since the 1960's. The ETF consists of over 13 thermal vacuum chambers sized and configured to handle the majority of test payloads. Testing is performed around the clock with multiple tests being conducted simultaneously. Chamber selection to achieve the best match with test articles and juggling program schedules, at times, can be a challenge. The ETF's Sunspot chamber has had tests scheduled and operated back-to-back for several years and provides the majority of schedule conflicts. Future test programs have been identified which surpass the current Sunspot availability. This paper describes a very low cost alternate to reduce schedule conflicts by utilizing government excess equipment

Sisco, Jimmy D.↗

Instrument for Measuring Cryo CTE

Coefficient of thermal expansion is an integral part of the performance of optical systems, especially for those, which operate at cryogenic temperatures. The measurement of the coefficient of relevant materials has been of continuous interest. Besides commercial measurement sources, development of one-of-a-kind tools have always been of interest due to local needs. This paper describes one such development at the University of Alabama in Huntsville (UAH). The approach involves two vertical rods (one sample and one reference) on a flat platform. A probe bar is held horizontally atop the two samples. A temperature change will generally cause rotation of the probe bar. A mirrored surface on one end of the probe bar is used to measure the rotation using the reflection of an incident laser beam upon it. A position-sensing detector measures the change of the reflected beam spot position. Using other known quantities, the change determines the coefficient of thermal expansion of the sample material as a function of temperature. A parallel measurement of the rotation of the sample support platform is also performed to account for any unwanted background effects. This system has been demonstrated in a cryogenic chamber at the NASA Marshall Space Flight Center X-ray Calibration Facility (XRCF). We present the system details, achievable sensitivity, and up-to-date experimental performance.

Vikram, Chandra S.↗

Cryo-Infrared Optical Characterization at NASA GSFC

The development of large space infrared optical systems, such as the Next Generation Space Telescope (NGST), has increased requirements for measurement accuracy in the optical properties of materials. Many materials used as optical components in infrared optical systems, have strong temperature dependence in their optical properties. Unfortunately, data on the temperature dependence of most of these materials is sparse. In this paper, we provide a description of the capabilities existing in the Optics Branch at the Goddard Space Flight Center that enable the characterization of the refractive index and absorption coefficient changes and other optical properties in infrared materials at cryogenic temperatures. Details of the experimental apparatus, which include continuous flow liquid helium optical cryostat, and a Fourier Transform Infrared (FTIR) spectrometer are discussed.

Boucarut, Ray↗

Cryo Testing of tbe James Webb Space Telescope's Integrated Science Instrument Module

The Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope will be integrated and tested at the Environmental Test Facilities at Goddard Space Flight Center (GSFC). The cryogenic thermal vacuum testing of the ISIM will be the most difficult and problematic portion of the GSFC Integration and Test flow. The test is to validate the coupled interface of the science instruments and the ISIM structure and to sufficiently stress that interface while validating image quality of the science instruments. The instruments and the structure are not made from the same materials and have different CTE. Test objectives and verification rationale are currently being evaluated in Phase B of the project plan. The test program will encounter engineering challenges and limitations, which are derived by cost and technology many of which can be mitigated by facility upgrades, creative GSE, and thorough forethought. The cryogenic testing of the ISIM will involve a number of risks such as the implementation of unique metrology techniques, mechanical, electrical and optical simulators housed within the cryogenic vacuum environment. These potential risks are investigated and possible solutions are proposed.

VanCampen, Julie↗