Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Throttling Cryogen Boiloff To Control Cryostat Temperature

An improved design has been proposed for a cryostat of a type that maintains a desired low temperature mainly through boiloff of a liquid cryogen (e.g., liquid nitrogen) at atmospheric pressure. (A cryostat that maintains a low temperature mainly through boiloff of a cryogen at atmospheric pressure is said to be of the pour/fill Dewar-flask type because its main component is a Dewar flask, the top of which is kept open to the atmosphere so that the liquid cryogen can boil at atmospheric pressure and cryogenic liquid can be added by simply pouring it in.) The major distinguishing feature of the proposed design is control of temperature and cooling rate through control of the flow of cryogen vapor from a heat exchanger. At a cost of a modest increase in complexity, a cryostat according to the proposal would retain most of the compactness of prior, simpler pour/fill Dewar-flask cryostats, but would utilize cryogen more efficiently (intervals between cryogen refills could be longer).

Cunningham, Thomas↗

Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks

Large cryogenic liquid hydrogen tanks are composed of inner and outer shells. The outer shell is exposed to the ambient environment while the inner shell holds the liquid hydrogen. The region between these two shells is evacuated and typically filled with a powderlike insulation to minimize radiative coupling between the two shells. A technique was developed for detecting the presence of an air leak from the outside environment into this evacuated region. These tanks are roughly 70 ft (approx. equal 21 m) in diameter (outer shell) and the inner shell is roughly 62 ft (approx. equal 19 m) in diameter, so the evacuated region is about 4 ft (approx. equal 1 m) wide. A small leak's primary effect is to increase the boil-off of the tank. It was preferable to install a more accurate fill level sensor than to implement a boil-off meter. The fill level sensor would be composed of an accurate pair of pressure transducers that would essentially weigh the remaining liquid hydrogen. This upgrade, allowing boil-off data to be obtained weekly instead of over several months, is ongoing, and will then provide a relatively rapid indication of the presence of a leak.

Youngquist, Robert↗

Rapid-Chill Cryogenic Coaxial Direct-Acting Solenoid Valve

A commercially available cryogenic direct- acting solenoid valve has been modified to incorporate a rapid-chill feature. The net effect of the modifications is to divert some of the cryogenic liquid to the task of cooling the remainder of the cryogenic liquid that flows to the outlet. Among the modifications are the addition of several holes and a gallery into a valve-seat retainer and the addition of a narrow vent passage from the gallery to the atmosphere.

Richard, James↗

Improved liquid-level sensor for cryogenics

Liquid-level indicator, consisting of a diode heated by a resistor, allows simultaneous use of two or three of the liquids nitrogen, hydrogen, and helium. Operation depends on strong temperature-dependence of the forward resistance of a germanium diode and the difference between liquid and vapor in heat-transfer properties.

Hyman, L. G.↗

Validation of a Two-Phase CFD Model for Autogenous Pressurization and Expulsion

This paper presents a two-phase computational fluid dynamics (CFD) model for simulating autogenous pressurization and expulsion in a cryogenic liquid hydrogen storage tank, utilizing a volume-of-fluid (VOF) approach combined with the kinetics-based Schrage equation to accurately capture the phase boundary and interfacial heat, mass, and momentum transfer between liquid and vapor phases. The model is validated against experimental data from NASA's K-site tank facility, specifically experimental case 225, which involved pressurization and controlled expulsion of liquid hydrogen. Various turbulence models are evaluated to assess their influence on model accuracy. The CFD simulations successfully replicate key thermodynamic behaviors observed during the experiments, including pressure evolution, temperature profiles, and phase-change dynamics at the vapor-liquid interface. The predicted tank pressures, temperatures, and pressurant requirements agree with experimental data, with pressurant mass predictions within 16\% of observed values. This study highlights the importance of selecting appropriate turbulence models to accurately simulate complex flow and heat transfer phenomena during tank pressurization and expulsion. By enhancing the accuracy and reliability of CFD models for liquid hydrogen under cryogenic conditions, this research contributes to developing efficient cryogenic propellant management strategies for future space missions.

Computational Fluid Dynamics↗

Experimental, Numerical, and Analytical Slosh Dynamics of Water and Liquid Nitrogen in a Spherical Tank

Understanding, predicting, and controlling fluid slosh dynamics is critical to safety and improving performance of space missions when a significant percentage of the spacecraft's mass is a liquid. Computational fluid dynamics simulations can be used to predict the dynamics of slosh, but these programs require extensive validation. Many experimental and numerical studies of water slosh have been conducted. However, slosh data for cryogenic liquids is lacking. Water and cryogenic liquid nitrogen are used in various ground-based tests with a spherical tank to characterize damping, slosh mode frequencies, and slosh forces. A single ring baffle is installed in the tank for some of the tests. Analytical models for slosh modes, slosh forces, and baffle damping are constructed based on prior work. Select experiments are simulated using a commercial CFD software, and the numerical results are compared to the analytical and experimental results for the purposes of validation and methodology-improvement.

slosh↗

Continuous-Reading Cryogen Level Sensor

Two pressure transducers used in system for measuring amount of cryogenic liquid in tank. System provides continuous measurements accurate within 0.03 percent. Sensors determine pressure in liquid and vapor in tank. Microprocessor uses pressure difference to compute mass of cryogenic liquid in tank. New system allows continuous sensing; unaffected by localized variations in composition and density as are capacitance-sensing schemes.

Barone, F. E.↗

Inverted Outflow Ground Testing of Cryogenic Propellant Liquid Acquisition Devices

NASA is currently developing propulsion system concepts for human exploration. These propulsion concepts will require the vapor free acquisition and delivery of the cryogenic propellants stored in the propulsion tanks during periods of microgravity to the exploration vehicles engines. Propellant management devices (PMDs), such as screen channel capillary liquid acquisition devices (LADs), vanes and sponges have been used for earth storable propellants in the Space Shuttle Orbiter and other spacecraft propulsion systems, but only very limited propellant management capability currently exists for cryogenic propellants. NASA is developing PMD technology as a part of their cryogenic fluid management (CFM) project. System concept studies have looked at the key factors that dictate the size and shape of PMD devices and established screen channel LADs as an important component of PMD design. Modeling validated by normal gravity experiments is examining the behavior of the flow in the LAD channel assemblies (as opposed to only prior testing of screen samples) at the flow rates representative of actual engine service (similar in size to current launch vehicle upper stage engines). Recently testing of rectangular LAD channels has included inverted outflow in liquid oxygen and liquid hydrogen. This paper will report the results of liquid oxygen testing compare and contrast them with the recently published hydrogen results; and identify the sensitivity these results to flow rate and tank internal pressure.

Liquid Oxygen↗

Inverted Outflow Ground Testing of Cryogenic Propellant Liquid Acquisition Devices

NASA is currently developing propulsion system concepts for human exploration. These propulsion concepts will require the vapor free acquisition and delivery of the cryogenic propellants stored in the propulsion tanks during periods of microgravity to the exploration vehicles engines. Propellant management devices (PMD's), such as screen channel capillary liquid acquisition devices (LAD's), vanes and sponges have been used for earth storable propellants in the Space Shuttle Orbiter and other spacecraft propulsion systems, but only very limited propellant management capability currently exists for cryogenic propellants. NASA is developing PMD technology as a part of their cryogenic fluid management (CFM) project. System concept studies have looked at the key factors that dictate the size and shape of PMD devices and established screen channel LADs as an important component of PMD design. Modeling validated by normal gravity experiments is examining the behavior of the flow in the LAD channel assemblies (as opposed to only prior testing of screen samples) at the flow rates representative of actual engine service (similar in size to current launch vehicle upper stage engines). Recently testing of rectangular LAD channels has included inverted outflow in liquid oxygen and liquid hydrogen. This paper will report the results of liquid oxygen testing compare and contrast them with the recently published hydrogen results; and identify the sensitivity of these results to flow rate and tank internal pressure.

Microgravity↗

Gas-phase flowrate effect on disintegrating cryogenic liquid-jets

Two phase liquid and gaseous nitrogen flow in a pneumatic two fluid atomizer was investigated. Characteristic dropsize for cryogenic sprays were measured with a scattered light scanning instrument developed at NASA-Lewis. Tests were conducted primarily in the aerodynamic stripping regime of liquid jet atomization. At a sampling distance of bar-x=1.3 cm, the Sauter mean, D(sub 32), and volume median, D(sub v.5), drop diameters were measured and correlated with nitrogen gas flowrate, W(sub n), to give the following expressions: D sub 32 to the -1=210W(sub n) to the -1.33 and D(sub v.5) to the -1=150 W(sub n to the -1.33, where reciprocal diameters and gas flowrate are in cm (-1) and g/sec, respectively. The exponent 1.33 for nitrogrn gas flowrate, W(sub n), is the same as that predicted by atomization theory for liquid-jet breakup in high velocity gasflow. When the spray was sampled at axial distances of bar-x=2.5 and 4.5 cm downstream of the atomizer, the exponent decreased to 1.2 and 0.9, respectively. This was attributed to the loss of small droplets due to their rapid vaporization.

Ingebo, Robert D.↗

Gas-phase flowrate effect on disintegrating cryogenic liquid-jets

Two phase liquid and gaseous nitrogen flow in a pneumatic two fluid atomizer was investigated. Characteristic dropsize for cryogenic sprays were measured with a scattered light scanning instrument developed at NASA-Lewis. Tests were conducted primarily in the aerodynamic stripping regime of liquid jet atomization. At a sampling distance of bar-x =1.3 cm, the Sauter mean, D(sub 32), and volume median, D(sub v.5), drop diameters were measured and correlated with nitrogen gas flowrate, W(sub n), to give the following expressions: D sub 32 to the -1=210W(sub n) to the -1.33 and D(sub v.5) to the -1=150 W(sub n to the -1.33, where reciprocal diameters and gas flowrate are in cm (-1) and g/sec, respectively. The exponent 1.33 for nitrogen gas flowrate, W(sub n), is the same as that predicted by atomization theory for liquid-jet breakup in high velocity gasflow. When the spray was sampled at axial distances of bar-x=2.5 and 4.5 cm downstream of the atomizer, the exponent decreased to 1.2 and 0.9, respectively. This was attributed to the loss of small droplets due to their rapid vaporization.

Ingebo, Robert D.↗

Internship at NASA Kennedy Space Center's Cryogenic Test laboratory

NASA's Kennedy Space Center (KSC) is known for hosting all of the United States manned rocket launches as well as many unmanned launches at low inclinations. Even though the Space Shuttle recently retired, they are continuing to support unmanned launches and modifying manned launch facilities. Before a rocket can be launched, it has to go through months of preparation, called processing. Pieces of a rocket and its payload may come in from anywhere in the nation or even the world. The facilities all around the center help integrate the rocket and prepare it for launch. As NASA prepares for the Space Launch System, a rocket designed to take astronauts beyond Low Earth Orbit throughout the solar system, technology development is crucial for enhancing launch capabilities at the KSC. The Cryogenics Test Laboratory at Kennedy Space Center greatly contributes to cryogenic research and technology development. The engineers and technicians that work there come up with new ways to efficiently store and transfer liquid cryogens. NASA has a great need for this research and technology development as it deals with cryogenic liquid hydrogen and liquid oxygen for rocket fuel, as well as long term space flight applications. Additionally, in this new era of space exploration, the Cryogenics Test Laboratory works with the commercial sector. One technology development project is the Liquid Hydrogen (LH2) Ground Operations Demonstration Unit (GODU). LH2 GODU intends to demonstrate increased efficiency in storing and transferring liquid hydrogen during processing, loading, launch and spaceflight of a spacecraft. During the Shuttle Program, only 55% of hydrogen purchased was used by the Space Shuttle Main Engines. GODU's goal is to demonstrate that this percentage can be increased to 75%. Figure 2 shows the GODU layout when I concluded my internship. The site will include a 33,000 gallon hydrogen tank (shown in cyan) with a heat exchanger inside the hydrogen tank attached to a refrigerator capable of removing 850 Watts at 20 Kelvin (shown in green). The refrigerator and most of its supporting equipment will be kept in a standard shipping container (shown in pink). Currently, GODU is in the fabrication process and some of the large components have already been purchased.

Holland, Katherine↗

NASA Advanced Fuels Program

NASA with the USAF Research Laboratory and it's industry partners, has been conducting planning and research into advanced fuels. This work is sponsored under the NASA Advanced Space Transportation Program (ASTP). The current research focus is on Alternative Hydrocarbon fuels, Monopropellants, and Solid Cryogens for storing atoms of Hydrogen, Boron, Carbon, and Aluminum. Alternative hydrocarbons that are under consideration are bi cyclo propylidene, spiro pentane, and tri propargyl amine. These three fuels have been identified as initial candidates to increase the specific impulse of hydrocarbon fueled rockets by 10-15 seconds over 02/RP-1. Formulation of these propellants is proceeding this year, and rocket engine testing is planned for the near future. Monopropellant investigations are focused on dinitramine based fuels, and potential collaborations with the US Navy. The dinitramine fuel work is being conducted under an Small Business Innovation research (SBIR) contract with the team of Orbital Technologies Corp. (Madison, WI) and SRI (Menlo Park, CA). This work may lead to a high density, high specific impulse monopropellants that can simplify the operations for launch vehicles and spacecraft. Solid Cryogens are being considered to store atoms of Hydrogen, Boron, Carbon, and Aluminum. Stored atom propellants are potentially the highest specific impulse chemical rockets that may be practical. These fuels are composed of atoms, stored in solid cryogenic particles, suspended in a cryogenic liquid or gel. The fuel would be fed to a rocket engine as a slurry or gelled cryogenic liquid with the suspended particles with the trapped atoms. Testing is planned to demonstrate the formation of the particles, and then characterize the slurry flows. Rocket propellant and propulsion technology improvements can be used to reduce the development time and operational costs of new space vehicle programs. Advanced propellant technologies can make the space vehicles safer, more operable, and better performing. Five technology areas are described: Monopropellants, Alternative Hydrocarbons, Gelled Hydrogen, Metallized Gelled Propellants, and High Energy Density Materials. The benefits of these propellants for future vehicles are outlined using mission study results and the technologies are briefly discussed.

Palaszewski, Bryan↗

Carbon- and Ceramic-Matrix Composite Nozzle Extensions for Liquid Rocket Engines

Carbon-carbon (C-C) composite and ceramic matrix composite (CMC) nozzle extensions are being considered and developed for use with a variety of cryogenic liquid rocket engine systems. Some of the potential applications include in-space, lunar lander, and launch vehicle upper stage propulsion systems. Composite material systems of interest include C-C and carbon/silicon-carbide (C-SiC) composites, as well as modified versions of such composites (coatings, mixed matrices, oxidation inhibitors, etc.). Nozzle extension materials and fabrication methods under development by industry support both National Aeronautics and Space Administration (NASA) and Department of Defense (DOD) requirements, as well as those of the broader Commercial Space industry. Marshall Space Flight Center (MSFC) efforts are aimed at both (a) assisting industry with the development of composite nozzle extensions for cryogenic liquid rocket engines, and (b) developing and demonstrating capabilities for characterizing, testing, and qualifying such nozzle extensions. Results of recent MSFC nozzle-extension characterization efforts and engine firing demonstrations will be presented.

carbon-carbon↗

System for Testing Thermal Insulation of Pipes

An apparatus and method have been developed for measuring the rates of leakage of heat into pipes carrying liquids, the purpose of the measurements being to quantify the thermal performance of the insulation system. The apparatus is designed primarily for testing pipes used to carry cryogenic liquids, but can also be used for measuring the thermal performance of other insulated pipes or piping systems. The basic measurement principle is straightforward: The outer surface of the pipe insulation is maintained at a fixed warmer temperature. The interior of the pipe is maintained in a narrow fixed lower-temperature range by means of a regular liquid (e.g., water) that is pumped through the pipe at a known flow rate or a cryogenic liquid (e.g., nitrogen) that is saturated at atmospheric pressure and replenished until steady-state conditions are achieved. In the case of water or another liquid pumped through, the inlet and outlet temperatures are measured and heat-leak power is calculated as the mass flow rate of the liquid multiplied by the specific heat of the liquid multiplied by the inlet-to-outlet temperature rise of the liquid. In the case of liquid nitrogen or another low-temperature boiling liquid, the heat-leak power is calculated as the rate of boil-off multiplied by the latent heat of vaporization of the liquid. Then the thermal-insulation performance of the pipe system can be calculated as a function of the measured heat-leak power, the inner and outer boundary temperatures, and the dimensions of the pipe. The apparatus can test as many as three pipes simultaneously. The pipes can have inner diameters up to .15 cm and outer diameters up to .20 cm. The lengths of the pipes may vary; typical lengths are of the order of 18 m. Two thermal guard boxes . one for each end of the pipe(s) under test . are used to make the inlet and outlet fluid connections to the pipe(s) (see figure). The connections include bellows that accommodate thermal expansion and contraction of the pipes. The guard boxes and pipe(s) are positioned so that the pipe(s) slope upward from the upstream to the downstream end at an angle of at least 2 . The upward slope allows vapor bubbles to accumulate at the downstream end. The thermal guard boxes keep the ends of the pipes at the lower interior temperature to prevent spurious lengthwise leakage of heat into the pipes. It is important to prevent this spurious heat leakage because, if it were allowed to occur, it could contribute a large error in the measured heat-leak power. The upstream thermal guard box includes a heat exchanger through which liquid flowing into the pipe(s) is subcooled to the saturation temperature corresponding to the ambient pressure. Conversely, this heat exchanger can also be used to warm the flowing liquid to a desired fixed temperature. The apparatus includes a temperature control device that is placed around each pipe under test. Each device is operated under thermostatic control to maintain the outer surface of the pipe insulation at the specified test temperature. All measurements are recorded on a portable data-acquisition system.

Fesmire, James E.↗