Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic tanks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Predicted thermal response of a cryogenic fuel tank exposed to simulated aerodynamic heating profiles with different cryogens and fill levels

A two dimensional finite difference thermal model was developed to predict the effects of heating profile, fill level, and cryogen type prior to experimental testing the Generic Research Cryogenic Tank (GRCT). These numerical predictions will assist in defining test scenarios, sensor locations, and venting requirements for the GRCT experimental tests. Boiloff rates, tank-wall and fluid temperatures, and wall heat fluxes were determined for 20 computational test cases. The test cases spanned three discrete fill levels and three heating profiles for hydrogen and nitrogen.

Hanna, Gregory J.↗

Nodal Modeling of Submerged Helium Injection Pressurization of a Cryogenic Propellant Tank

Subcooling of cryogenic propellant by helium injection is one of the most effective methods for suppressing bulk boiling and keeping subcooled propellant conditions for pre-launch, launch, and post-launch pressurization applications. For tank pressurization, submerged helium injection can substantially reduce helium consumption by infusing gaseous propellant into the tank ullage. This paper describes a thermodynamic model of the helium bubbling process in liquid oxygen to estimate the amount of oxygen vapor absorbed by the rising helium bubbles and the amount of subcooling of liquid oxygen due to evaporative heat and mass transfer. The physics of helium dissolution during the pressurization process is also modeled, primarily for liquid hydrogen propellant where the dissolution is more significant. The analyses were performed in a simulation model of tank pressurization built with Generalized Fluid System Simulation Program (GFSSP), a general-purpose flow network code developed at NASA/Marshall Space Flight Center. The numerical predictions of subcooling have been compared with the experimental data of Cho et al. which investigated the propellant subcooling effect as a function of system pressure, helium injection temperature, and flowrate for a non-drained submerged injection system. The numerical predictions of helium consumption have been compared with the test data from a NASA Centaur test vehicle which included both direct and submerged injection with draining of propellants. Hydrogen propellant testing of the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) conducted at NASA/Glenn Research Facility was also analyzed. The data used for the model validation were taken in 1-g, but the model was developed to be applicable in both multi-g and micro-g environments.

tank pressurization↗

Evaluation of Carbon Composite Overwrap Pressure Vessels Fabricated Using Ionic Liquid Epoxies Project

The intent of the work proposed here is to ascertain the viability of ionic liquid (IL) epoxy based carbon fiber composites for use as storage tanks at cryogenic temperatures. This IL epoxy has been specifically developed to address composite cryogenic tank challenges associated with achieving NASA's in-space propulsion and exploration goals. Our initial work showed that an unadulterated ionic liquid (IL) carbon-fiber composite exhibited improved properties over an optimized commercial product at cryogenic temperatures. Subsequent investigative work has significantly improved the IL epoxy and our first carbon-fiber Composite Overwrap Pressure Vessel (COPV) was successfully fabricated. Here additional COPVs, using a further improved IL epoxy, will be fabricated and pressure tested at cryogenic temperatures with the results rigorously analyzed. Investigation of the IL composite for lower pressure liner-less cryogenic tank applications will also be initiated. It is expected that the current Technology Readiness Level (TRL) will be raised from about TRL 3 to TRL 5 where unambiguous predictions for subsequent development/testing can be made.

Grugel, Richard↗

Nodal Numerical Modeling of Submerged Helium Injection in a Cryogenic Propellant Tank

Subcooling of cryogenic propellant by helium injection is one of the most effective methods for suppressing bulk boiling and keeping subcooled propellant conditions for pre-launch, launch, and post-launch pressurization applications. For tank pressurization, submerged helium injection can substantially reduce helium consumption by infusing gaseous propellant into the tank ullage. This paper presents a mathematical model of the helium bubbling process in liquid oxygen to estimate the amount of oxygen vapor absorbed by the rising helium bubbles and the amount of subcooling of liquid oxygen due to evaporative heat and mass transfer. This mathematical model was incorporated in a simulation model of tank pressurization built with Generalized Fluid System Simulation Program (GFSSP), a general-purpose flow network code developed at NASA/Marshall Space Flight Center. The numerical predictions of subcooling have been compared with the experimental data of Cho et al. which investigated the propellant subcooling effect as a function of system pressure, helium injection temperature, and flowrate for a non-drained submerged injection system. The numerical predictions of helium consumption have been compared with the test data from a NASA Centaur test vehicle which included both direct and submerged injection with draining of propellants. The numerical model developed with GFSSP has been validated against two sets of experimental data and has been shown to predict both propellant subcooling and helium consumption to within 30% in most cases. The test data used for the model validation were taken in 1-g, but the mass diffusion model was developed to be applied in both 1-g and micro-g environments.

Cryogenics↗

Validation of Loci-Stream for Autogenous Pressurization of Cryogenic Propellant Tank

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

cryogenic fluid management↗

Validation of Loci-Stream for Autogenous Pressurization of Cryogenic Propellant Tank

Autogenous pressurization of cryogenic propellant tanks eliminates the need to have an additional pressurant tank on the space vehicle, which is highly advantageous due to reduced vehicle mass and design complexity. Autogenous pressurization therefore is one of the key technologies for deep space exploration and long-term space missions. The complex interaction of thermal gradients, turbulence and phase change near the interface make the problem a challenging one to model. Nodal analysis tools and reduced order models are unable to capture the necessary physics. 3-D CFD analyses are necessary to fully characterize autogenous pressurization. CFD analyses pose their own difficulties. The requisite CFD tool to tackle this problem need to be modular with the ability to incorporate various physics models, efficient, and computationally scalable for simulating flight size tanks. NASA MSFC's Loci-Stream CFD tool along with the VOF module is a great candidate to fit this mold. We demonstrate our modeling approach and validation of Loci-Stream for predicting autogenous pressurization of a flight scale propellant tank in order for the solver to serve as a reliable design and analysis tool for NASA's CFM application needs. Liquid hydrogen tank pressurization tests carried out at the MSFC test stand 300 facilities provide reliable validation data for this purpose. These tests were modeled using the Loci-Stream solver with a newly implemented two-phase sharp interface treatment. We show that our modeling approach and CFD solver predict the autogenous pressurization phenomena satisfactorily, and document challenging aspects of modeling this problem.

CFM↗

Thermal Structures Technology Development for Reusable Launch Vehicle Cryogenic Propellant Tanks

Analytical and experimental studies conducted at the NASA Langley Research Center for investigating integrated cryogenic propellant tank systems for a Reusable Launch Vehicle are described. The cryogenic tanks are investigated as an integrated tank system. An integrated tank system includes the tank wall, cryogenic insulation, Thermal Protection System (TPS) attachment sub-structure, and TPS. Analysis codes are used to size the thicknesses of cryogenic insulation and TPS insulation for thermal loads, and to predict tank buckling strengths at various ring frame spacings. The unique test facilities developed for the testing of cryogenic tank components are described. Testing at cryogenic and high-temperatures verifies the integrity of materials, design concepts, manufacturing processes, and thermal/structural analyses. Test specimens ranging from the element level to the subcomponent level are subjected to projected vehicle operational mechanical loads and temperatures. The analytical and experimental studies described in this paper provide a portion of the basic information required for the development of light-weight reusable cryogenic propellant tanks.

Johnson, Theodore F.↗

Thermal Structures Technology Development for Reusable Launch Vehicle Cryogenic Propellant Tanks

Analytical and experimental studies conducted at the NASA, Langley Research Center (LaRC) for investigating integrated cryogenic propellant tank systems for a reusable launch vehicle (RLV) are described. The cryogenic tanks are investigated as an integrated tank system. An integrated tank system includes the tank wall, cryogenic insulation, thermal protection system (TPS) attachment sub-structure, and TPS. Analysis codes are used to size the thicknesses of cryogenic insulation and TPS insulation for thermal loads, and to predict tank buckling strengths at various ring frame spacings. The unique test facilities developed for the testing of cryogenic tank components are described. Testing at cryogenic and high-temperatures verifies the integrity of materials, design concepts, manufacturing processes, and thermal/structural analyses. Test specimens ranging from the element level to the subcomponent level are subjected to projected vehicle operational mechanical loads and temperatures. The analytical and experimental studies described in this paper provide a portion of the basic information required for the development of light-weight reusable cryogenic propellant tanks.

Johnson, Theodore F.↗

Computational Fluid Dynamics Based Extraction of Heat Transfer Coefficient in Cryogenic Propellant Tanks

Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from: inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. The work presented under this task uses the first-principles based Computational Fluid Dynamics (CFD) technique to compute heat transfer from tank wall to the cryogenic fluids, and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between tank wall and cryogenic propellant, and that between tank wall and ullage gas were then simulated. The results showed that commonly used heat transfer correlations for either vertical or horizontal plate over predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.

Yang, H. Q.↗

CFD Extraction of Heat Transfer Coefficient in Cryogenic Propellant Tanks

Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. This study uses first-principles based CFD methodology to compute heat transfer from the tank wall to the cryogenic fluids and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between the tank wall and cryogenic propellant, and that between the tank wall and ullage gas were then simulated. The results showed that the commonly used heat transfer correlations for either vertical or horizontal plate over-predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.

Yang, H. Q.↗

Preliminary Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank strongly affect the condition of the tank and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A preliminary thermal stress analysis of a high-pressure cryogenic storage tank was performed. Stresses during normal operation were determined, as well as the transient temperature distribution. An elastic analysis was used to determine the thermal stresses in the inner wall based on the temperature data. The results of this elastic analysis indicate that the inner wall of the storage tank will experience thermal stresses of approximately 145,000 psi (1000 MPa). This stress level is well above the room-temperature yield strength of 304L stainless steel, which is about 25,000 psi (170 MPa). For this preliminary analysis, several important factors have not yet been considered. These factors include increased strength of 304L stainless steel at cryogenic temperatures, plastic material behavior, and increased strength due to strain hardening. In order to more accurately determine the thermal stresses and their affect on the tank material, further investigation is required, particularly in the area of material properties and their relationship to stress.

Baker, J. Mark↗

Analysis of Thermal-Protection Systems for Space-Vehicle Cryogenic-Propellant Tanks

Analytical techniques are presented that permit the calculation of heat-transfer rates with various thermal-protection systems for liquid-cryogenic-propellant tanks subjected to on-board, solar, and planetary heat fluxes. The thermal-protection systems considered include using closely spaced reflective surfaces (foils) and widely spaced reflective surfaces (shadow shields), insulation, arrangement of vehicle components, orientation with respect to radiant heating sources, and coatings for the control of solar absorptivity. The effectiveness of these thermal-protection systems in reducing propellant heating is shown both for ideal heat-transfer models and for a simplified hydrogen-oxygen terminal stage on a Mars mission. The proper orientation of a space-vehicle cryogenic tank with respect to the Sun is one of the more beneficial methods of reducing the heating effect of solar flux. Shadow shields can be extremely effective in reducing the propellant heating due to both solar and on-board fluxes. However, low-altitude planet orbits can result in high propellant heating rates due to planetary radiation reflected from the shields. For low-altitude orbits of more than a few days, foils appear to be desirable for all cryogenic-tank surfaces. Foils are also effective in reducing the on-board heating. A choice of shadow shields or foils cannot be made until a particular vehicle and a particular mission are chosen. The thermal conductivity of insulation materials would have to be lower by about two orders of magnitude with no increase in density before insulation could compete with reflective surfaces for use in long-duration thermal protection of cryogenic tanks in space. To demonstrate the application of the methods devised, thermal-protection systems are developed for a hydrogen-oxygen terminal stage for typical Mars missions.

SPACE VEHICLE↗

Advanced cryogenic propellant tank development status

The design and development of cryogenic propellant tanks with reduced weight and production costs is described with reference to applications for the National Launch System. The development program focused on the use of an aluminum-lithium alloy to demonstrate the production capability, manufacturability, and strength inherent in the novel material. Other key parameters for the alloy include fracture toughness, stress-corrosion resistance, and conformance to NASA specifications for cryogenic propellant tanks. The commercially produced aluminum-lithium alloy product forms are shown to operate acceptably in the temperature range for cryogenic propellant tanks. The alloy under consideration and the tank design are important advances in the development of ultralightweight launch-vehicle structures.

Scholz, E. F.↗

Cryogenic Storage Tank Non-Destructive Evaluation

This slide presentation reviews the work in non-destructive evaluation (NDE) of cryogenic storage tanks. Four large cryogenic tanks, constructed in 1965 with perlite insulation in the annular regions, are of concern. The construction of the tanks, two Liquid Oxygen (LOX) and two Liquid Hydrogen (LH2), are described. The loss rate for the LOX tank at Pad A is slightly higher than that for the one at Pad B. The concerns for the LH2 tank at Pad B are that there is a significantly higher boil-off rate than that at Pad A, that there is mold growth, indicative of increased heat flow, that there is a long down-time needed for repairs, and that 3 of 5 full thermal cycles have been used on the Pad B LH2 tank. The advantages and disadvantages of thermal imaging are given. A detailed description of what is visible of the structures in the infra-red is given and views of the thermal images are included. Missing Perlite is given as the probable cause of the cold spot on the Pad B LH2 tank. There is no indications of problematic cold regions on the Pad A LH2 tank, as shown by the thermal images given in the presentation. There is definite indication of a cold region on the Pad A LOX tank. There is however concerns with thermal imaging, as thermal images can be significantly effected by environmental conditions, image differences on similar days but with different wind speeds. Other effects that must be considered include ambient temperature, humidity levels/dew, and cloud reflections

Arens, Ellen↗

Technique for Configuring an Actively Cooled Thermal Shield in a Flight System

Broad area cooling shields are a mass-efficient alternative to conductively cooled thermal radiation shielding. The shield would actively intercept a large portion of incident thermal radiation and transport the heat away using cryogenic helium gas. The design concept consists of a conductive and conformable surface that maximizes heat transfer and formability. Broad Area Cooled (BAC) shields could potentially provide considerable mass savings for spaceflight applications by eliminating the need for a rigid thermal radiation shield for cryogen tanks. The BAC consists of a network of capillary tubes that are thermally connected to a conductive shield material. Chilled helium gas is circulated through the network and transports unwanted heat away from the cryogen tanks. The cryogenic helium gas is pumped and chilled simultaneously using a specialized pulse-tube cryocooler, which further improves the mass efficiency of the system. By reducing the thermal environment temperature from 300 to 100 K, the radiative heat load on a cryogen tank could be reduced by an order of magnitude. For a cryogenic liquid propellant scenario of oxygen and hydrogen, the boiloff of hydrogen would be significantly reduced and completely eliminated for oxygen. A major challenge in implementing this technology on large tanks is that the BAC system must be easily scalable from lab demonstrations to full-scale missions. Also, the BAC shield must be conformable to complex shapes like spheres without losing the ability to maintain constant temperature throughout. The initial design maximizes thermal conductivity between the capillary tube and the conductive radiation shielding by using thin, corrugated aluminum foil with the tube running transverse to the folds. This configuration has the added benefit of enabling the foil to stretch and contract longitudinally. This allows the BAC to conform to the complex curvature of a cryogen tank, which is key to its success. To demonstrate a BAC shield system with minimal impact to current cryogen tank designs, the shielding must be applied after the final assembly of the tank and supporting structure. One method is to pre-fabricate the shield in long strips. A spool of corrugated aluminum foil with a thermally sunk aluminum capillary running through the center could then be simply wound around the cryogen tanks and encapsulated within the multi-layer insulation (MLI) blanket. Then, on orbit, the BAC would intercept thermal radiation coming in through the MLI and transport it away from the cryogen tanks. An optimization of the design could be done to take into account mass savings from thinner MLI blankets, eliminating solid thermal shields, and ultimately, a reduction in the required cryogen tank size.

Barkfknecht, Peter↗

Cryogenic Fuel Tank Draining Analysis Model

One of the technological challenges in designing advanced hypersonic aircraft and the next generation of spacecraft is developing reusable flight-weight cryogenic fuel tanks. As an aid in the design and analysis of these cryogenic tanks, a computational fluid dynamics (CFD) model has been developed specifically for the analysis of flow in a cryogenic fuel tank. This model employs the full set of Navier-Stokes equations, except that viscous dissipation is neglected in the energy equation. An explicit finite difference technique in two-dimensional generalized coordinates, approximated to second-order accuracy in both space and time is used. The stiffness resulting from the low Mach number is resolved by using artificial compressibility. The model simulates the transient, two-dimensional draining of a fuel tank cross section. To calculate the slosh wave dynamics the interface between the ullage gas and liquid fuel is modeled as a free surface. Then, experimental data for free convection inside a horizontal cylinder are compared with model results. Finally, cryogenic tank draining calculations are performed with three different wall heat fluxes to demonstrate the effect of wall heat flux on the internal tank flow field.

Greer, Donald↗

Cryogenic Propellant Tank Drain Simulation with a Stratified Ullage Nodal Model

Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.

Richard G Hibbs↗