Search NASA⌕ Search

SEARCH · Search NASA

Results for “current limiters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Theoretical assessment of the transition between electron emission mechanisms in a collisional crossed-field gap

Understanding the transition to the limiting current under vacuum and collisional conditions for thermal-field emission in a crossed-field gap is critical for characterizing the operating regime for numerous applications, such as high-power microwaves and Hall thrusters. By deriving the exact solution for the current density as a function of cathode temperature (and, by extension, initial velocity), cathode electric field, applied voltage, collision frequency, and magnetic field, we determine the transition from the canonical current source (thermal-field emission) to the vacuum and collisional limiting currents under different operating conditions. Here, we further show that the exact solution recovers the asymptotic solutions for the canonical and limiting currents for vacuum and collisional crossed-field gaps under appropriate limits. The exact solution demonstrates that the critical current decreases with both increasing magnetic field strength and increasing collisionality. Nexus phase space plots constructed by matching the individual asymptotic solutions provide the conditions for the transitions between mechanisms, elucidating when a single mechanistic equation would suffice and when theories combining multiple mechanisms are necessary.

Breen, Lorin I. [Purdue Univ., West Lafayette, IN ↗

Counter-Current Flow Limitation Studies in Complex Geometries Utilizing Interface Capturing Simulations Coupled with PID Flow Rate Controller

In nuclear thermal-hydraulic studies, counter-current flow limitation (CCFL) typically refers to steam rising at a fast rate such that it prevents coolant from draining down within a confined channel. CCFL is a crucial issue in nuclear reactor safety analysis. This study investigates CCFL in debris bed channels using high-resolution interface-capturing simulations. A novel proportional-integral-derivative flow rate controller is developed to efficiently achieve the CCFL conditions. Verification studies confirm that CCFL occurs under the same conditions with or without the controller, demonstrating that PID control ensures accurate prediction. Three debris bed channel geometries were examined: a cylindrical channel, a channel with small obstacles, and a channel with large obstacles. Results show that obstacles significantly impact flow behavior, interfacial shear, wall shear, and pressure gradients required for CCFL. Furthermore, the comparison with experimental data confirmed that simulations incorporating geometric complexities align more closely with experimental CCFL conditions. A pressure gradient correlation was also developed for CCFL prediction.

Counter-current flow limitation↗

Electropneumatic transducer automatically limits motor current

Pneumatic controller regulates the load on a centrifugal freon compressor in a water cooling system, thus limiting the current input to an electric motor driving it. An electromechanical transducer monitoring the motor input current sends out air signals which indicate changes in the current to the pneumatic controller.

Lovitt, T. F.↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Electrochemical Study of OH - in Molten MgCl 2 -NaCl-KCl Salts

Here the present study determines the equilibrium concentration of OH- in molten MgCl 2 -NaCl-KCl salts and measures the kinetic properties data of OH- (diffusion coefficient, exchange current density, charge transfer coefficient, limiting current density, and standard rate constant) accordingly at different temperatures. The equilibrium concentration of OH- descends as the temperature increases, which ranges from 4.11 to 2.84 × 10 -6 mol cm -3 in the temperature range of 600 °C–800 °C. The diffusion coefficient follows Arrhenius law with a value between 2.46 and 4.48 × 10 -4 cm 2 s -1 . The exchange and limit current densities, and standard rate constant increase with temperature. The calculated standard rate constant κ 0 follows Arrhenius law, which is in the range from 1.23 to 2.50 × 10 -4 cm s -1 . The measured charge transfer coefficient is independent of temperature, which validates the present measurements.

14 SOLAR ENERGY↗

Design and Testing of a Breadboard Electrical Power Control Unit for the Fluid Combustion Facility Experiment

The Fluid Combustion Facility (FCF) Project and the Power Technology Division at the NASA Glenn Research Center (GRC) at Lewis Field in Cleveland, OH along with the Sundstrand Corporation in Rockford, IL are jointly developing an Electrical Power Converter Unit (EPCU) for the Fluid Combustion Facility to be flown on the International Space Station (ISS). The FCF facility experiment contains three racks: A core rack, a combustion rack, and a fluids rack. The EPCU will be used as the power interface to the ISS 120V(sub dc) power distribution system by each FCF experiment rack which requires 28V(sub dc). The EPCU is a modular design which contains three 120V(sub dc)-to-28V(sub dc) full-bridge, power converters rated at 1 kW(sub e) each bus transferring input relays and solid-state, current-limiting input switches, 48 current-limiting, solid-state, output switches; and control and telemetry hardware. The EPCU has all controls required to autonomously share load demand between the power feeds and--if absolutely necessary--shed loads. The EPCU, which maximizes the usage of allocated ISS power and minimizes loss of power to loads, can be paralleled with other EPCUs. This paper overviews the electrical design and operating characteristics of the EPCU and presents test data from the breadboard design.

Kimnach, Greg L.↗

Serial and parallel power equipment with high-temperature superconducting elements

One of the prospective, practical applications of high-temperature superconductors is the fault-current limitation in electrical energy networks. The development and testing of experimental HTSC serial current limiters have been reported in the literature. A Hungarian electric power company has proposed the development of a parallel equipment for arc suppressing both in the industrial and customers' networks. On the basis of the company's proposal the authors have outlined the scheme of a compound circuit that can be applied both for current limitation and arc suppressing. In this paper the design principles and methods of the shunt equipment are presented. These principles involve the electrical, mechanical and cryogenic aspects with the special view on the electrical and mechanical connection between the HTSC material and the current lead. Preliminary experiments and tests have been carried out to demonstrate the validity of the design principles developed. The results of the experiments and of the technological investigations are presented.

Bencze, Laszlo↗

Integral Battery Power Limiting Circuit for Intrinsically Safe Applications

A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal oxide semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels. The comparator detects this drop and opens the switch before the current in the inductor has a chance to respond. This circuit protects both the current and voltage from exceeding safe levels. Typically, this type of protection is accomplished by a fuse or a circuit breaker, but in order for a fuse or a circuit breaker to blow or trip, the current must exceed the safe levels momentarily, which may be just enough time to ignite anything in a hazardous environment. To prevent this from happening, a fuse is typically current-limited by the addition of the resistor to keep the current within safe levels while the fuse reacts. The use of a resistor is acceptable for non-battery applications where the wasted energy and voltage drop across the resistor can be tolerated. The use of the switch and inductor minimizes the wasted energy. For example, a circuit runs from a 3.6-V battery that must be current-limited to 200 mA. If the circuit normally draws 10 mA, then an 18-ohm resistor would drop 180 mV during normal operation, while a typical switch (0.02 ohm) and inductor (0.97 ohm) would only drop 9.9 mV. From a power standpoint, the current-limiting resistor protection circuit wastes about 18 times more power than the switch and the inductor configuration. In the fault condition, both the resistor and the inductor react immediately. The resistor reacts by allowing more current to flow and dropping the voltage. Initially, the inductor reacts by dropping the voltage, and then by not allowing the current to change. When the comparator detects the drop in voltage, it opens the switch, thus preventing any further current flow. The inductor alone is not sufficient protection, because after the voltage drop has settled, the inductor would then allow the current to change, in this example, the current would be 3.7 A. In the fault condition, the resistor is flowing 200 mA until the fuse blows (anywhere from 1 ms to 100 s), while the switch and inductor combination is flowing about 2 A test current while monitoring for the fault to be corrected. Finally, as an additional safety feature, the circuit can be configured to hold the switch opened until both the load and source are disconnected.

Burns, Bradley M.↗

Electrochemical Study on the Kinetic Properties of Fe 2+ /Fe, Ni 2+ /Ni, Cr 2+ /Cr and Cr 3+ /Cr 2+ in Molten MgCl 2 -KCl-NaCl Salts

Here, the fundamental kinetic parameters of corrosion product ions (Fe, Ni and Cr ions) are of significant importance to understand the corrosion mechanisms of the structural materials in the molten salts. In the present study, the fundamental data of Fe 2+ , Ni 2+ , Cr 2+ and Cr 3+ (diffusion coefficient D, exchange current density i 0 , charge transfer coefficient α, limiting current density i L and standard rate constant k0) were measured at different concentrations (1.53 × 10 –6 –7.48 × 10 –4 mol cm –3 ) and temperatures (600 °C–800 °C). The values of D are independent of concentrations and follow Arrhenius law with temperature, which descend in the order of D Cr 2+ > D Fe 2+ > D Cr 3+ > D Ni 2+ with values ranging from 0.94 × 10 –5 to 3.31 × 10 –5 cm 2 s –1 . Both i 0 and k 0 depend on the temperatures, which also follow Arrhenius law.

14 SOLAR ENERGY↗

Permanent Nanobubbles in Water: Liquefied Hollow Carbon Spheres Break the Limiting Diffusion Current of Oxygen Reduction Reaction

Porous liquids have traditionally been designed with sterically hindered solvents. Alternatively, recent efforts rely on dispersing microporous frameworks in simpler solvents like water. Here we report a unique strategy to construct macroporous water by selectively incorporating hydrophilicity on the surfaces of hydrophobic hollow carbon spheres (HCS). Specifically, we show that the stable dispersion surface ionized HCS in water while retaining the inherent porosity. The electrocatalytic conversion of small gas molecules in aqueous electrolytes is limited by the concentration and diffusion rates of gas molecules in water. In this case, macroporous water exhibited 6 times gas uptake compared to nonporous (pure) water. Furthermore, by leveraging the high gas capacity and enhanced diffusion kinetics, the limiting diffusion current of oxygen reduction reaction (ORR) in macroporous water is 2 times that in nonporous water, offering promising prospects for sustainable energy conversion technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Redox Flow Battery Having Metal-Ligand Complex

Researchers at Los Alamos National Laboratory have developed new non-aqueous electrolyte materials for redox flow batteries (RFB). These batteries are a viable technology for scalable energy storage beyond lithium ion batteries. Cost is currently limiting deployment, with poor energy density being the primary culprit. One way to improve energy density is by increasing the cell potential beyond the current limit in aqueous media. The higher cell potential and additional electrons stored per molecule will increase the energy density of the RFB medium, overcoming a critical limitation to the current RFBs. Like lithium ion batteries, RFB's can span from the kW to multi MW power storage systems. The nickel complexes described herein have demonstrated redox potentials >3 V which is at least twice the aqueous limit. We are interested in partnering with battery developers to further advance this technology to the product prototype stage.

25 ENERGY STORAGE↗

Hollow cathode plasma coupling study, 1986

The electron collection and emission characteristics of a simple hollow cathode contactor, an extended anode hollow cathode contactor supplied by JSC, and a ring cusp magnetic field contactor are presented and the effects of discharge power and argon or xenon expellant flowrate on these characteristics are examined. All of the contactors are shown to exhibit good electron emission performance over a wide range of discharge power and expellant type and flowrate. Good electron performance is shown to be more difficult to achieve. Results suggest that the extended anode and ring cusp contactors should perform satisfactorily to electron emission currents beyond 1000 mA and electron collection currents beyond 500 mA. All contactors performed better on xenon than argon. A general theory of plasma contactor operation in both the electron collection and electron emission modes, which describes the current-limiting effects of space-charge phenomena is given. This current-limiting and collecting phenomenon is shown to be a function of driving potential differences and emitting and collecting surface radius ratio for the case of a spherical geometry. Discharge power did not appear to influence the electron collection current substantially in the experiments so it is suggested in light of the model that the contactors are generally not limited by their ion production capabilities under conditions at which they were tested.

Wilbur, Paul J.↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Nonlocal, diamagnetic electromagnetic effects in magnetically insulated transmission lines

We identify the time-dependent physics responsible for the critical reduction of current losses in magnetically insulated transmission lines (MITLs) due to uninsulated space charge-limited currents of electrons emitted by field stress. A drive current of sufficiently short pulse length introduces a strong enough time dependence that steady-state results alone become inadequate for the complete understanding of current losses. The time-dependent physics can be described as a nonlocal, diamagnetic electromagnetic response of space charge limited currents. As the pulse length is increased or equivalently, the MITL length reduced, these time-dependent effects diminish and current losses converge to those predicted by the well-known Child–Langmuir law in the external (vacuum) fields. We present a simple one-dimensional (1D) model that encapsulates the essence of this physics. We find excellent agreement with 2D particle-in-cell simulations for two MITL geometries, Cartesian parallel plate and azimuthally symmetric straight coaxial. Based on the 1D model, we explore various scaling dependencies of MITL losses with relevant parameters, e.g., peak current, pulse length, geometrical dimensions, etc. We propose an improved physics model of magnetic insulation in the form of a Hull curve, which could also help improve predictions of current losses by common circuit element codes, such as BERTHA. Finally, we describe how to calculate the temperature rise due to electron impact within the 1D model.

Computer simulation↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Interfacial Atomistic Mechanisms of Lithium Metal Stripping and Plating in Solid–State Batteries

All-solid-state batteries based on a Li metal anode represent a promising next-generation energy storage system, but are currently limited by low current density and short cycle life. Further research to improve the Li metal anode is impeded by the lack of understanding in its failure mechanisms at lithium–solid interfaces, in particular, the fundamental atomistic processes responsible for interface failure. Here, using large-scale molecular dynamics simulations, the first atomistic modeling study of lithium stripping and plating on a solid electrolyte is performed by explicitly considering key fundamental atomistic processes and interface atomistic structures. In the simulations, the interface failure initiated with the formation of nano-sized pores, and how interface structures, lithium diffusion, adhesion energy, and applied pressure affect interface failure during Li cycling are observed. By systematically varying the parameters of solid-state lithium cells in the simulations, the parameter space of applied pressures and interfacial adhesion energies that inhibit interface failure during cycling are mapped to guide selection of solid-state cells. Furthermore, this study establishes the atomistic modeling for Li stripping and plating, and predicts optimal solid interfaces and new strategies for the future research and development of solid-state Li-metal batteries.

25 ENERGY STORAGE↗

A machine learning approach to predict thermal expansion of complex oxides

Although it is of scientific and practical importance, the state-of-the-art of predicting the thermal expansion of oxides over broad temperature and composition ranges by physics-based atomistic simulations is currently limited to qualitative agreements. We present an emerging machine learning (ML) approach to accurately predict the thermal expansion of cubic oxides with a dataset consisting of experimentally measured lattice parameters while using the metal cation polyhedron and temperature as descriptors. High-fidelity ML models that can accurately predict temperature- and composition-dependent lattice parameters of cubic oxides with isotropic thermal expansions have been successfully trained. The ML-predicted thermal expansions of oxides not included in the training dataset have shown good agreement with available experiments. The limitations of the current approach and challenges to go beyond cubic oxides with isotropic thermal expansion are also briefly discussed.

36 MATERIALS SCIENCE↗