Search NASA⌕ Search

SEARCH · Search NASA

Results for “current limiters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Space charge limited corrections to the power figure of merit for diamond

An interpretation of the unipolar figure of merit is formulated for wide bandgap (WBG) semiconductors based on the on-state specific resistance (RON,sp) derived from the space charge limited current–voltage relationship (Mott–Gurney square law). The limitations of the traditional Ohmic R ON,sp for WBG semiconductors are discussed, particularly at low doping, while the accuracy of the Mott–Gurney based R ON,sp is confirmed by Silvaco ATLAS drift–diffusion simulations of diamond Schottky pin diodes. The effects of incomplete ionization are considered as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EMPHATIC Silicon Strip Detector Efficiencies

EMPHATIC is an experiment at Fermilab which aims to reduce current neutrino flux uncertainties. This report discusses the limitations current neutrino flux uncertainties places on large scale neutrino experiments, provides background on the EMPHATIC experiment, and details the project of determining the efficiency of the Silicon Strip Detectors (SSDs) used in EMPHATIC. As part of the data analysis process and in order to increase the accuracy of EMPHATIC’s simulations a representation of efficiency of each SSD is required. To achieve this a data-driven analysis was performed on EMPHATIC's collected data using the Root and Art frameworks. Visual and numerical representations of efficiency were determined. The average efficiency over all SSDs is 98.58\%, however this number deflated as it includes known bad channels.

Olson, Virginia [Illinois U., Urbana (main)]↗

Determining the Efficiency of EMPHATICs Silicon Strip Detectors (SSDs)

EMPHATIC is an experiment at Fermilab which aims to reduce current neutrino flux uncertainties. This report discusses the limitations current neutrino flux uncertainties places on large scale neutrino experiments, provides background on the EMPHATIC experiment, and details the project of determining the efficiency of the Silicon Strip Detectors (SSDs) used in EMPHATIC. As part of the data analysis process and in order to increase the accuracy of EMPHATIC’s simulations a representation of efficiency of each SSD is required. To achieve this a data-driven analysis was performed on EMPHATIC's collected data using the Root and Art frameworks. Visual and numerical representations of efficiency were determined. The average efficiency over all SSDs is 98.58\%, however this number deflated as it includes known bad channels.

Olson, V. [Illinois U., Urbana (main)]↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Frequency Shift and $Q$ of Disordered Superconducting RF Cavities

Niobium superconducting radio-frequency (SRF) cavities for high-energy accelerator applications have been greatly improved in terms of the quality factor $Q$ by techniques such as Nitrogen doping. However, the mechanisms leading to improvement in $Q$ are still not fully understood. Quite recently the SRF group at Fermilab measured anomalies in the frequency shift of N-doped SRF Niobium cavities near the transition temperature. Here we report our theoretical analysis of these results based on the microscopic theory of superconductivity that incorporates anisotropy of the superconducting gap and inhomogeneous disorder in the screening region of the SRF cavities. We are able to account for frequency shift anomalies very close to $T_c$ on the order of fractions of 1 kHz. Our results for the frequency shift and Q are in good agreement with the experimental data reported for all four N-doped Nb SRF cavities by Bafia et al. We also compare our theory with an earlier report on a Nb sample measured at 60 GHz. In addition, we show that the quality factor calculated theoretically has a peak of upper convexity with the largest $Q$ at intermediate levels of disorder. For strong disorder, i.e. the dirty limit, pair breaking in the presence of disorder and screening currents limits the $Q$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NAWI Research Spotlight: Technoeconomic Assessment of Brine Valorization from Brackish Groundwater

This NAWI Research Spotlight Webinar was presented to the NAWI Alliance on June 27, 2024. The presentation describes project progress to date on a technoeconomic assessment of brine valorization from brackish groundwater. Desalination at inland brackish groundwater treatment plants is currently limited by high costs of concentrate management and disposal. With current methods, 5-25% of the feed is disposed of as concentrate, with 98% of disposal using conventional methods (i.e. no byproduct recovery). This project aims to assess the technical and economic feasibility of industrial ecosystems to desalinate brackish groundwater and supply existing and potential markets for clean concentrate or other bulk constituents from the brine.

Fritz, Alison↗

Minimizing Interfacial Resistance between Polymer Electrolytes and Metal Electrodes Using Applied Current

Reducing the interfacial resistance between different phases in electrochemical systems is crucial for enabling practical applications. In this work, we proposed a process for reducing the interfacial resistance between polymer electrolytes and metal electrodes. Thus far in the literature, the lowest interfacial resistance reported in these systems is 15 Ω·cm2. In this study, assembled and preconditioned symmetric cells with lithium–indium alloy electrodes showed similar values. The current through the cell was increased in steps up to the limiting current. This resulted in a permanent decrease of the interfacial resistance to values as low as 1 Ω·cm2, a value that is comparable to that of optimized lithium-ion batteries. The proposed process is general, and it could be applied to any combination of polymer electrolytes and metal electrodes.

Lee, Jaeyong↗

Quantum Mechanical Evaluation of CZTS Properties for Photovoltaic Applications

As a quaternary semiconductor, CZTS (Cu 2 ZnSnS 4 ) shows promise as a thin-film solar cell material. The constituent elements in CZTS are abundant and non-toxic, and CZTS has an ideal band gap (~1.5 eV) for solar cell applications, which produces a large absorption coefficient. Unfortunately, the low efficiencies and difficulties in synthesizing the desired crystallographic phase (kesterite) and the associated formation of antisite defects limit its deployment. Using theoretical and computational tools, we investigated these current limitations, explored strategies to resolve these issues, and developed design guidelines to improve the efficiency of CZTS-based sunlight absorbers. We first sought to understand the challenges associated with synthesizing the kesterite phase and proposed ways to favor kesterite growth, thus adding to the understanding of CZTS photovoltaics. We also analyzed the major limitations at the atomic scale lowering the efficiency of CZTS: the low open-circuit voltage (V oc ) and the short carrier lifetime, thus addressing the technical effectiveness of CZTS photovoltaics. We believe the latter is due to Shockley-Read-Hall (SRH) recombination centers associated with point defects. We also studied the electronic structure of interfaces and defects introducing such recombination centers, and explored doping strategies to reduce SRH recombination. Ultimately, these efforts will benefit the public by contributing to the development of cheap and efficient solar energy conversion technologies made from abundant, non-toxic materials.

14 SOLAR ENERGY↗

DEMONSTRATION OF MULTI-PHYSICS EVALUATION OF FUEL ROD BURST PROBABILITY WITH BURNUP EXTENSION UNDER LBLOCA CONDITIONS

Extending the fuel discharge burnup level, e.g., from the current limit of rod averaged discharge burnup limit of 62 GWD/MT to a proposed new limit of 75 GWD/MT, can provide significant economic benefits to the current fleet of operating light water reactors (LWRs). It allows for longer operating cycles and improved resource utilization. The major economic gain of longer operating cycles is attributable to the increased capacity factor resulting from decreased refueling time as a fraction of total operating time, as well as fewer assemblies to be discharged for a given amount of energy produced. The main licensing challenges for higher burnup fuel are to ensure fuel rod safety under design basis accident conditions, especially under large-break loss-of-coolant accident (LBLOCA) and reactivity insertion accident (RIA). In this work, two-year cycle core design for a typical 4-loop pressurized water reactor (PWR) is performed with enrichment increased up to 6% and burnup extended to 75 GWD/MT. The fuel rod burst potential evaluations under large-break loss-of-coolant accident (LBLOCA) conditions are subsequently performed using the multi-physics best estimate plus uncertainty analysis framework LOTUS (LOCA Toolkit for the U.S. LWRs) and the preliminary results are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reduced-Order Parameterized Short-Circuit Current Model of Inverter-Interfaced Distributed Generators

The short-circuit response of inverter-interfaced distributed generators (IIDGs) is not adequately represented in many conventional protection studies. This paper presents an in-depth analysis of IIDG behavior during grid faults and proposes a more accurate reduced-order parameterized short-circuit current (RPSC) model of inverters. Typical inverter components are thoroughly investigated to identify those that play dominant roles during faults. The paper shows that the current limiter is the dominant factor for the steady-state fault-current of inverter; while the inverter filter along with the severity of the voltage disturbance largely determine the initial transient spike of inverter fault current. The proposed model is low-order and can be used in large scale simulations. The parameters of the proposed RPSC model can be extracted from laboratory experiments without requiring proprietary manufacturer information. The proposed fault-current model is analogous to the well-known synchronous machine model that segregates the inverter fault current into subtransient, transient, and steady-state fault currents. Finally, experimental and simulation tests are presented to validate the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Simple, Scalable Large Deformation Solid Mechanics Implementation in the MOOSE Framework

This article describes a large deformation solid mechanics solver implemented as part of the freely available and open source MOOSE finite element simulation framework. The article documents the choices made in developing the solid mechanics framework and describes novel formulations for the gradient operator and constitutive modeling framework made to simplify implementations of different coordinate systems, stabilized gradient operators, and different constitutive model inputs and outputs. In the process, the article describes a new formulation that casts objective integration of the Cauchy stress as a linear transformation of the small stress rate. Finally, the article presents key implementation details and examines the parallel efficiency of the solid mechanics solver implemented in MOOSE. The implementation retains a good weak scaling efficiency beyond 1,000 parallel processes. The article includes a discussion of the factors limiting the parallel efficiency of implicit, large deformation solid mechanics codes on current high-performance computers, with the main current limitation being the scalability of the algebraic multigrid methods used to solve the linearized equilibrium equations.

Applied computing → Computer-aided design↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model of Inverter-Based Resources

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Is an NDA required to share a vendor Blackbox model for SC analysis? Differences in VRT detection and injection logics. Angle rotation is not addressed in control logics of most vendors. Current limitation logic during unbalanced faults is not clear. Model IBR as a current source with shunt to improve convergence

IBRs, Model of IBRs, Short Circuit Analysis, Class↗

Distributed Computing for the Project 8 Experiment

The Project 8 collaboration aims to measure the absolute neutrino mass or improve on the current limit by measuring the tritium beta decay electron spectrum. We present the current distributed computing model for the Project 8 experiment. Project 8 is in its second phase of data taking with a near continuous data rate of 1Gbps. The current computing model uses DIRAC (Distributed Infrastructure with Remote Agent Control) for its workflow and data management. A detailed meta-data assignment using the DIRAC File Catalog is used to automate raw data transfers and subsequent stages of data processing. The DIRAC system is deployed on containers managed using a Kubernetes cluster to provide a scalable infrastructure. A modified DIRAC Site Director provides the ability to submit jobs using Singularity on opportunistic High-Performance Computing (HPC) sites.

Distributed Computing, Kubernetes, DIRAC, Project ↗

Challenges and Opportunities in the Enzymatic Recycling of Nylons

Enzymatic depolymerization has the potential to contribute to nylon waste recycling. However, the implementation of a viable industrial process still lags far behind progress in enzymatic polyester recycling. Here we review the current biocatalytic nylon recycling landscape, highlighting biochemical, structural, and materials science barriers that currently limit depolymerization extents. We detail efforts to identify, engineer, and characterize new nylon depolymerases, where currently even the best biocatalysts rarely exceed ~1 wt% conversion of solid polymer to products. Based on our analyses, we suggest that limited substrate accessibility due to substrate crystallinity and hydrogen bonding, rather than intrinsic enzyme inefficiency or instability, is the primary bottleneck to enhanced depolymerization. Guided by successes in polyester enzymatic recycling, we outline a research roadmap combining nylonase engineering with polymer pretreatment, chemo-enzymatic cascades, and process analyses to accelerate development of viable enzymatic nylon recycling processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Black-Starting Microgrids Using Inverter-Based Distributed Energy Resources

Recent trends in power systems show increasing deployment of inverter-based distributed energy resources (DERs) at the distribution level. Efforts have also been made to use inverter-based DERs for system restoration of critical sections of distribution feeders. In the past few years, there has been active consideration of using local grid-forming (GFM) DERs, which can form their own voltage and frequency, to black-start microgrids instead of waiting for the bulk system for supply restoration. However, using current-limited inverter-based DERs for black-start operations with high inrush currents can pose some technical challenges. This paper presents detailed electromagnetic transient studies on a digital real-time simulator to assess the operational feasibility of using local inverter-based GFM DERs for microgrid black-start operations as a bottom-up approach instead of a top-down approach where the substation is used to restore critical sections of the feeder. The paper presents key modeling details for distribution system components for studying GFM DER-based microgrid black-start operations. The paper presents simulation results comparing different black-start approaches using GFM DERs for two test systems: i) a simple test microgrid and ii) a real-world utility microgrid currently being designed and deployed by Holy Cross Energy in Colorado.

black start↗

Lignin impairs Cel7A degradation of in vitro lignified cellulose by impeding enzyme movement and not by acting as a sink

Abstract Background Cellulose degradation by cellulases has been studied for decades due to the potential of using lignocellulosic biomass as a sustainable source of bioethanol. In plant cell walls, cellulose is bonded together and strengthened by the polyphenolic polymer, lignin. Because lignin is tightly linked to cellulose and is not digestible by cellulases, is thought to play a dominant role in limiting the efficient enzymatic degradation of plant biomass. Removal of lignin via pretreatments currently limits the cost-efficient production of ethanol from cellulose, motivating the need for a better understanding of how lignin inhibits cellulase-catalyzed degradation of lignocellulose. Work to date using bulk assays has suggested three possible inhibition mechanisms: lignin blocks access of the enzyme to cellulose, lignin impedes progress of the enzyme along cellulose, or lignin binds cellulases directly and acts as a sink. Results We used single-molecule fluorescence microscopy to investigate the nanoscale dynamics of Cel7A from Trichoderma reesei , as it binds to and moves along purified bacterial cellulose in vitro. Lignified cellulose was generated by polymerizing coniferyl alcohol onto purified bacterial cellulose, and the degree of lignin incorporation into the cellulose meshwork was analyzed by optical and electron microscopy. We found that Cel7A preferentially bound to regions of cellulose where lignin was absent, and that in regions of high lignin density, Cel7A binding was inhibited. With increasing degrees of lignification, there was a decrease in the fraction of Cel7A that moved along cellulose rather than statically binding. Furthermore, with increasing lignification, the velocity of processive Cel7A movement decreased, as did the distance that individual Cel7A molecules moved during processive runs. Conclusions In an in vitro system that mimics lignified cellulose in plant cell walls, lignin did not act as a sink to sequester Cel7A and prevent it from interacting with cellulose. Instead, lignin both blocked access of Cel7A to cellulose and impeded the processive movement of Cel7A along cellulose. This work implies that strategies for improving biofuel production efficiency should target weakening interactions between lignin and cellulose surface, and further suggest that nonspecific adsorption of Cel7A to lignin is likely not a dominant mechanism of inhibition.

09 BIOMASS FUELS↗

Transverse BBU Suppression with Feedback for Energy-Recovery Linacs

The Electron–Ion Collider (EIC) achieves its design luminosity by cooling the ion beam with a high-current electron beam generated in an energy-recovery linac (ERL). The baseline ERL lattice employs a BNL five-cell cavity that is frequency-scaled to 197 MHz, 591 MHz, and 1.773 GHz, raising concerns about multibunch beam-breakup (BBU) instabilities. Threshold currents for each frequency option are established with two independent BBU tracking codes, providing cross-validated operating margins that guide cavity selection. To further increase the current limit, we incorporate a digital transverse feedback (FB) system that targets the dominant higher-order modes (HOMs). Simulations show the FB raises the BBU threshold by roughly an order of magnitude: power-spectral-density analysis of the beam centroid at the linac exit confirms strong suppression of the aliased HOM peak, although some spectral growth appears at secondary frequencies. This combined study quantifies baseline BBU limits, demonstrates effective active mitigation, and charts a practical path toward robust, high-current operation of the EIC ERL.

Accelerator Physics↗