Search NASA⌕ Search

SEARCH · Search NASA

Results for “data cubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

MAGIC: M arching Cubes Isosurface Uncertainty Visualization for G auss i an Uncertain Data With Spatial C orrelation

Here, in this paper, we study the propagation of data uncertainty through the marching cubes algorithm for isosurface visualization for correlated uncertain data. Consideration of correlation has been shown paramount for avoiding errors in uncertainty quantification and visualization in multiple prior studies. Although the problem of isosurface uncertainty with spatial data correlation has been previously addressed, there are two major limitations to prior treatments. First, there are no analytical formulations for uncertainty quantification of isosurfaces when the data uncertainty is characterized by a Gaussian distribution with spatial correlation. Second, as a consequence of the lack of analytical formulations,existing techniques resort to a Monte Carlo sampling approach, which is expensive and difficult to integrate into visualization tools. To address these limitations, we present a closed-form framework to efficiently derive uncertainty in marching cubes level-sets for Gaussian uncertain data with spatial correlation (MAGIC). To derive closed-form solutions, we leverage the Hinkley's derivation on the ratio of Gaussian distributions. With our analytical framework, we achieve a significant speed-up and enhanced accuracy of uncertainty quantification over classical Monte Carlo methods. We further accelerate our analytical solutions using many-core processors to achieve speed-ups up to 585× and integrability with production visualization tools for broader impact. We demonstrate the effectiveness of our correlation-aware uncertainty framework through experiments on meteorology, urban flow, and astrophysics simulation datasets.

Gaussian↗

SIMILARITY BETWEEN THE C{sup 18}O (J = 1-0) CORE MASS FUNCTION AND THE INITIAL MASS FUNCTION (IMF) IN THE S140 REGION

We present the results of C{sup 18}O(J = 1-0) mapping observations of a 20' x 18' area in the Lynds 1204 molecular cloud associated with the Sharpless 2-140 (S140) H II region. The C{sup 18}O cube ({alpha}-{delta}-v{sub LSR}) data show that there are three clumps of sizes {approx}1 pc in the region. Two of these have peculiar redshifted velocity components at their edges, which can be interpreted as the results of the interaction between the cloud and the Cepheus Bubble. From the C{sup 18}O cube data, clumpfind identified 123 C{sup 18}O cores, which have mean radius, velocity width in FWHM, and LTE mass of 0.36 {+-} 0.07 pc, 0.37 {+-} 0.09 km s{sup -1}, and 41 {+-} 29 M{sub sun}, respectively. Considering the uncertainty in the C{sup 18}O abundance, all the cores in S140 are most likely to be gravitationally bound. We derived a C{sup 18}O core mass function (CMF), which shows a power-law-like behavior above a turnover at 30 M{sub sun}. The best-fit power-law index of -2.1 {+-} 0.2 is quite consistent with that of the initial mass function (IMF) and the C{sup 18}O CMF in the OMC-1 region as found by Ikeda and Kitamura. Kramer et al. estimated the power-law index of -1.65 in S140 from the C{sup 18}O(J = 2-1) data, which is inconsistent with this study. The C{sup 18}O(J = 2-1) data are spatially limited to the central part of the cloud and are likely to be biased toward high-mass cores, leading to the flatter CMF. Consequently, this study and our previous study strongly support that the power-law form of the IMF has already been determined at the density of {approx}< 10{sup 3}-10{sup 4} cm{sup -3}, traced by the C{sup 18}O(J = 1-0) line.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMAGINE: first neutron protein structure and new capabilities for neutron macromolecular crystallography

The first high-resolution neutron protein structure of perdeuterated rubredoxin from Pyrococcus furiosus ( Pf Rd) determined using the new IMAGINE macromolecular neutron crystallography instrument at the Oak Ridge National Laboratory is reported. Neutron diffraction data extending to 1.65 Å resolution were collected from a relatively small 0.7 mm 3 Pf Rd crystal using 2.5 d (60 h) of beam time. The refined structure contains 371 out of 391, or 95%, of the D atoms of the protein and 58 solvent molecules. The IMAGINE instrument is designed to provide neutron data at or near atomic resolution (1.5 Å) from crystals with volume <1.0 mm 3 and with unit-cell edges <100 Å. Beamline features include novel elliptical focusing mirrors that deliver neutrons into a 2.0 × 3.2 mm focal spot at the sample position with full-width vertical and horizontal divergences of 0.5 and 0.6°, respectively. Variable short- and long-wavelength cutoff optics provide automated exchange between multiple-wavelength configurations (λ min = 2.0, 2.8, 3.3 Å to λ max = 3.0, 4.0, 4.5, ~20 Å). These optics produce a more than 20-fold increase in the flux density at the sample and should help to enable more routine collection of high-resolution data from submillimetre-cubed crystals. Notably, the crystal used to collect these Pf Rd data was 5–10 times smaller than those previously reported.

Meilleur, Flora↗

Constraints on the dark matter annihilation from Fermi-LAT observation of M31

Gamma-ray is a good probe of dark matter (DM) particles in the Universe. We search for the DM annihilation signals in the direction of the Andromeda galaxy (M31) using 7.5 year Fermi-LAT pass 8 data. Similar to Pshirkov et al. (2016), we find that there is residual excess emission from the direction of M31 if only the galactic disk as traced by the far infrared emission is considered. Adding a point-like source will improve the fitting effectively, although additional slight improvements can be found if an extended component such as a uniform disk or two bubbles is added instead. Taking the far infrared disk plus a point source as the background model, we search for the DM annihilation signals in the data. We find that there is strong degeneracy between the emission from the galaxy and that from 10s GeV mass DM annihilation in the main halo with quark final state. However, the required DM annihilation cross section is about 10{sup −25}–10{sup −24} cm{sup 3}s{sup −1}, orders of magnitude larger than the constraints from observations of dwarf spheroidal galaxies, indicating a non-DM origin of the emission. If DM subhalos are taken into account, the degeneracy is broken. When considering the enhancement from DM subhalos, the constraints on DM model parameters are comparable to (or slightly weaker than) those from the population of dwarf spheroidal galaxies. We also discuss the inverse Compton scattering component from DM annihilation induced electrons/positrons. For the first time we include an energy dependent template of the inverse Compton emission (i.e., a template cube) in the data analysis to take into account the effect of diffusion of charged particles. We find a significant improvement of the constraints in the high mass range of DM particles after considering the inverse Compton emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Computed Tomography (CT) Analysis of 3D Printed Lattice Structures

LATTICE structures are increasingly used in product design across different industries, including the Department of Energy (DOE), due to their high strength and lightweight properties. These structures possess qualities such as high stiffness, energy absorption, large surface area, and structural support. To ensure lattice structures' quality and symmetry, it is crucial to have defect-free structures. However, in some cases, traditional non-destructive evaluation methods may not be practical due to encasing lattice structures in material. To analyze the lattice structures' quality, this project will employ CT imaging to gain access to the encased structures and perform a detailed analysis of each section. Three 3D printed complex lattice cubes were created, with two exposed and one encased in material, for this project. The CT X-ray cabinet will be used to scan all three cubes, and the data collected will be reconstructed and evaluated using complex interpretation software. This analysis will allow for a detailed examination of the structure's porosity, inclusions, cracks, wall thickness, and symmetry in each section.

36 MATERIALS SCIENCE↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPE6 Atmospheric Lidar Data User Guide

The Wind Cube v2 is a vertically-profiling, remote sensing instrument based on pulsed Light Detection and Ranging (Lidar) technology that provideshigh quality wind measurements on par with an IEC calibrated meteorological mast. The instrument uses four radial laser beams (0, 90, 180, 270° in the azimuth, scan angle 28° from zenith) and one vertically (V) orientated beam to measure flow characteristics from 40 m up to 290 m above ground level at 12 user-programmable heights (Figure 1). Lidar creates a “virtual” meteorological tower whereby the characteristics of the wind in the lower part of the planetary boundary layer are sampled. It takes roughly 4 seconds to complete a full conical scan, followed by the 5thbeam (V) pointed in the vertical position. The underlying principle of pulsed lidar measurements of wind is the use of optical heterodyne (coherent) detection, in which laser pulses are transmitted into the atmosphere and scattered off of naturally-occurring small dust particles or aerosols entrained in the ambient flow field (Figure 2). Radial velocity is proportional to Doppler frequency shift. In simple to moderately complex terrain wind speed accuracy is 0.1 m/s, wind direction accuracy is 1.5°.

58 GEOSCIENCES↗

Environmental conditions leading to fogging in commercial poly(vinyltoluene) plastic scintillators

We report light scattering particles can appear in environmentally-exposed pieces of plastic scintillator materials, leading to decreased scintillation light output. In this work, 1” cubes of commercially-available plastic scintillators were aged hydrothermally at temperatures between 25–55 °C, and 0%–100% relative humidity (R.H.), and the mass uptake and degree of light scattering were measured after cooling below the aging temperature. A correlation was found between moisture mass uptake and degree of light scattering, and the fogging phenomenon was found to be reversible upon moisture desorption. Additionally, variable temperature light scattering studies revealed a correlation between the temperature of fog onset and moisture mass uptake in hydrothermally-aged 1” scintillator cubes. The fog onset data was further used in a local weather-based model to predict the appearance of light scattering in deployed radiation portal monitor panels, and the model was validated with several specimens collected from retired portal panels. Together, the results quantitatively characterize the observed environmental aging of plastic scintillator radiation portal panels, give insight to deployed panel lifetime as a function of environment, and pave the way for future developments in environmentally-stable radiation portal monitors.

36 MATERIALS SCIENCE↗

A HOT AND MASSIVE ACCRETION DISK AROUND THE HIGH-MASS PROTOSTAR IRAS 20126+4104

We present new spectral line observations of the CH{sub 3}CN molecule in the accretion disk around the massive protostar IRAS 20126+4104 with the Submillimeter Array, which, for the first time, measure the disk density, temperature, and rotational velocity with sufficient resolution (0.″37, equivalent to ∼600 au) to assess the gravitational stability of the disk through the Toomre- Q parameter. Our observations resolve the central 2000 au region that shows steeper velocity gradients with increasing upper state energy, indicating an increase in the rotational velocity of the hotter gas nearer the star. Such spin-up motions are characteristics of an accretion flow in a rotationally supported disk. We compare the observed data with synthetic image cubes produced by three-dimensional radiative transfer models describing a thin flared disk in Keplerian motion enveloped within the centrifugal radius of an angular-momentum-conserving accretion flow. Given a luminosity of 1.3 × 10{sup 4} L {sub ⊙}, the optimized model gives a disk mass of 1.5 M {sub ⊙} and a radius of 858 au rotating about a 12.0 M {sub ⊙} protostar with a disk mass accretion rate of 3.9 × 10{sup −5} M {sub ⊙} yr{sup −1}. Our study finds that, in contrast to some theoretical expectations, the disk is hot and stable to fragmentation with Q > 2.8 at all radii which permits a smooth accretion flow. These results put forward the first constraints on gravitational instabilities in massive protostellar disks, which are closely connected to the formation of companion stars and planetary systems by fragmentation.

79 ASTRONOMY AND ASTROPHYSICS↗

Materials Data on BeCu by Materials Project

CuBe is Tetraauricupride structured and crystallizes in the cubic Pm-3m space group. The structure is three-dimensional. Be is bonded in a body-centered cubic geometry to eight equivalent Cu atoms. All Be–Cu bond lengths are 2.33 Å. Cu is bonded in a body-centered cubic geometry to eight equivalent Be atoms.

36 MATERIALS SCIENCE↗

Tomo2Mesh: Fast Reconstruction and Visualization of Tomography Data in Mesh Format

Tomo2Mesh is an open-source project targeted towards real-time reconstruction, segmentation, and visualization of computed tomography (CT) data in mesh format. The CT reconstruction scheme is based on filtered back-projection of voxel subsets. The segmentation scheme uses a 3D convolutional neural network. To allow for fast, real-time reconstruction, voxel subsets are first identified by coarse reconstruction. The detail in specific regions of interest is improved through full reconstruction of voxel subsets in that region. Data structures are implemented to store and process voxel subsets. Finally, voxel data is labeled using connected components to detect disconnected regions such as voids whose morphological attributes (e.g., Feret diameter, principal axis orientation, local number density, size, etc.) can be measured also in real-time. Finally, a fast marching cubes implementation processes labeled voxel data into a triangular face mesh (vertices and faces) in .ply format for visualization in Paraview or other mesh visualization tools. The code provides a simple programming interface for detecting, classifying, and visualizing regions of interest based on morphology. For example, detected voids can be classified as round pores or extended cracks. Highly porous neighborhoods can be identified based on local number density. The mesh texture (or color) is assigned based these morphological attributes to allow smart visualization scenarios in real-time (e.g., show only long cracks). At the time of first release (July 2022), extraction of face mesh for visualization for raw CT data from a 2 megapixel camera would take between 1-5 minutes for most scenarios.

TEKAWADE, ANIKET↗

Near infrared spectral imaging of explosives using a tunable laser source

Diffuse reflectance near infrared hyperspectral imaging is an important analytical tool for a wide variety of industries, including agriculture consumer products, chemical and pharmaceutical development and production. Using this technique as a method for the standoff detection of explosive particles is presented and discussed. The detection of the particles is based on the diffuse reflectance of light from the particle in the near infrared wavelength range where CH, NH, OH vibrational overtones and combination bands are prominent. The imaging system is a NIR focal plane array camera with a tunable OPO/laser system as the illumination source. The OPO is programmed to scan over a wide spectral range in the NIR and the camera is synchronized to record the light reflected from the target for each wavelength. The spectral resolution of this system is significantly higher than that of hyperspectral systems that incorporate filters or dispersive elements. The data acquisition is very fast and the entire hyperspectral cube can be collected in seconds. A comparison of data collected with the OPO system to data obtained with a broadband light source with LCTF filters is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Global Magneto-ionic Medium Survey: A Faraday Depth Survey of the Northern Sky Covering 1280–1750 MHz

The Galactic interstellar medium hosts a significant magnetic field, which can be probed through the synchrotron emission produced from its interaction with relativistic electrons. Linearly polarized synchrotron emission is generated throughout the Galaxy and, at longer wavelengths, modified along nearly every path by Faraday rotation in the intervening magneto-ionic medium. Full characterization of the polarized emission requires wideband observations with many frequency channels. We have surveyed polarized radio emission from the Northern sky over the range 1280–1750 MHz, with channel width 236.8 kHz, using the John A. Galt Telescope (diameter 25.6 m) at the Dominion Radio Astrophysical Observatory, as part of the Global Magneto-Ionic Medium Survey. The survey covered 72% of the sky, decl. −30° to +87° at all R.A. The intensity scale was absolutely calibrated, based on the flux density and spectral index of Cygnus A. Polarization angle was calibrated using the extended polarized emission of the Fan Region. Data are presented as brightness temperatures with angular resolution 40′. Sensitivity in Stokes Q and U is 45 mK rms in a 1.18 MHz band. We have applied rotation measure synthesis to the data to obtain a Faraday depth cube of resolution 150 rad m{sup −2} and sensitivity 3 mK rms of polarized intensity. Features in Faraday depth up to a width of 110 rad m{sup −2} are represented. The maximum detectable Faraday depth is ±2 × 10{sup 4} rad m{sup −2}. The survey data are available at the Canadian Astronomy Data Centre.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗