Search NASA⌕ Search

SEARCH · Search NASA

Results for “dc polarization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Airborne Arctic Stratospheric Expedition Preparation: Ozone

This video shows the rollout of the ER-2 and DC-8 at Ames, takeoffs and landings, and operations aboard the DC-8 and ER-2 in Puntas Arenas, Chile. Animation of the north polar regions showing the ozone hole is also included.

Source record↗

Alfven Wave - DC Dualism in Description of Stationary Field-Aligned Currents

In many cases, the field-aligned currents (FACs) in the Earth's magnetosphere and heliosphere may be described in terms of both DC currents and the currents of a propagating Alfven wave. The simplest example is when a propagating Alfven wave transports a potential hop along the magnetic fieid: between the source of the wave and its front, the problem is well stationary and includes the stationary field-aligned currents, transporting the electric charges along the magnetic field, which may be described as a DC problem, and only at the front of the wave there are the polarization (inertial) currents, closing across the magnetic field. In some cases, the Alfven wave approach brings better understanding to many problems. We will consider here the results of the applications of this approach to two long-staying problems: the effect of saturation of the transpolar voltage in the Earth's magnetosphere, and the experimentally-observed existence of the strong field-aligned currents in the subtle Mercury's magnetosphere which is not able tc close the measured field-aligned currents.

Khazanov, George V.↗

An Intrinsic Fiber-Optic Sensor for Structure Lightning Current Measurement

An intrinsic optical-fiber sensor based on Faraday Effect is developed that is highly suitable for measuring lightning current on aircraft, towers and complex structures. Originally developed specifically for aircraft installations, it is light-weight, non-conducting, structure conforming, and is immune to electromagnetic interference, hysteresis and saturation. It can measure total current down to DC. When used on lightning towers, the sensor can help validate other sensors and lightning detection network measurements. Faraday Effect causes light polarization to rotate when the fiber is exposed to a magnetic field in the direction of light propagation. Thus, the magnetic field strength can be determined from the light polarization change. By forming closed fiber loops and applying Ampere's law, measuring the total light rotation yields the total current enclosed. A broadband, dual-detector, reflective polarimetric scheme allows measurement of both DC component and AC waveforms with a 60 dB dynamic range. Two systems were built that are similar in design but with slightly different sensitivities. The 1310nm laser system can measure 300 A - 300 kA, and has a 15m long sensing fiber. It was used in laboratory testing, including measuring current on an aluminum structure simulating an aircraft fuselage or a lightning tower. High current capabilities were demonstrated up to 200 kA at a lightning test facility. The 1550nm laser system can measure 400 A - 400 kA and has a 25m fiber length. Used in field measurements, excellent results were achieved in the summer of 2012 measuring rocket-triggered lightning at the International Center for Lightning Research and Testing (ICLRT), Camp Blanding, Florida. In both systems increased sensitivity can be achieved with multiple fiber loops. The fiber optic sensor provides many unique capabilities not currently possible with traditional sensors. It represents an important new tool for lightning current measurement where low weight, complex shapes, large structure dimension, large current, and low frequency capabilities are important considerations.

Nguyen, Truong X.↗

Influence of discharge polarity on streamer breakdown criterion of ambient air in a non-uniform electric field

Streamer breakdown of atmospheric air with non-uniform dc electric field in a needle-to-plate electrode configuration is studied using a semi-analytic model and experimental measurements. A high voltage (either positive or negative) is applied to a hollow needle with 0.51 mm outer diameter and 0.25 mm inner diameter separated from a planar ground electrode by a gap distance of 0.1–1.4 cm. Breakdown voltages are recorded for both positive and negative discharge polarities. Empirical relations between the critical avalanche size for streamer breakdown and the gap distance are proposed. Using these empirical relations, a semi-analytic model based on Meek's criterion for streamer breakdown is developed to accurately predict the measured breakdown voltages. It is found that for pd > 380 Torr cm (or d > 0.5 cm at one atmosphere) streamer breakdown of ambient air occurs at a lower applied voltage for a positively biased needle compared to that with a negatively biased needle, referred as the polarity effect. For pd < 380 Torr cm breakdown is attained at a lower applied voltage with a negatively biased needle compared to that with a positively biased needle, and breakdown mode transits from the polarity effect to the so called inverted polarity effect.

42 ENGINEERING↗

Tropospheric- Stratospheric Measurement Studies Summary

The two high altitude aircraft, ER-2 NASA #706 and 709 and the DC-8 NASA #717 are in active use in several programs of upper atmospheric research to study polar ozone changes, stratospheric-tropospheric exchange processes and atmospheric effects of aviation aircraft. The ER-2 has participated in seven major missions which mainly concentrated on vortex dynamics and the large losses of Ozone in the Polar regions (Ozone hole) observed in the spring. One mission verified the complex dynamical chemical and physical processes that occur during sunrise and sunset. Stratospheric Tracers of Atmospheric Transport (STRAT) obtained background measurements using the full ER-2 suite of instruments. Photochemistry of Ozone Loss in the Arctic Region in Summer (POLARIS) in 1997 assisted in understanding the mid-latitude and Arctic Ozone losses during the Northern Summer. The DC-8 with the Meteorological Measurement System (MMS) has participated in the Subsonic Aircraft: Cloud and Contrail Effects Special Study (SUCCESS), in 1996 and the Subsonic assessment Ozone and Nitrogen oxide experiment (SONEX) in 1997 missions. The MMS with its sophisticated software accurately measures ground speed and attitude, in-situ static and dynamic pressure total temperature, which are used to calculate the three dimensional wind fields, static pressure, temperature and turbulence values to meteorological accuracy. The meteorological data is not only of interest for its own sake in atmospheric dynamical processes such as mountain waves and flux measurements; but is also required by other ER-2 experiments that simultaneously measure water vapor, O3, aerosols, NO, HCl, CH4, N2O, ClO, BrO, CO2, NOy, HOx and temperature gradients. MMS products are extensively used to assist in the interpretation of their results in understanding the importance of convective effects relative to in-situ chemical changes, as may be noted by examining the list of references attached. The MMS consists of three subsystems: (a) aircraft instrumentation, inertial navigation system (INS), static and dynamic pressure taps, (b) additional dedicated instrumentation measuring angle of attack, yaw, total temperature, and a GPS which on the DC-8 measures position, velocity and attitude (c) an on board data, storage and computing acquisition system. This instrumentation and the associated software requires both an on-going laboratory ground calibration procedure for the total air temperature, static and total pressure inputs, verification of the INS dynamic response and also extensive air measurements and intercomparisons which ultimately verify and calibrate the complete system and its software. More than the usual accuracy is required because of the near cancellation occurring in the difference between the ground speed and true airspeed vectors used to give the wind vector. In the past year we have redesigned, recalibrated and used the MMS system on the NASA DC-8 that was previously used in the SUCCESS mission for the SONEX mission. Two papers were co-authored based on SUCCESS flights. Several reports and handouts were written for SONEX. Calibrations of the DC-8 pressure transducer temperature measuring thermistors was completed and an extensive analysis spanning several years of data files of the DC-8 Rosemount pressure transducer calibrations was done.

Browen, Stuart W.↗

Dual-polarization airborne lidar observations of polar stratospheric cloud evolution

Dual-polarization 0.532 micron lidar data show systematic polar stratospheric cloud (PSC) evolution along a portion of the Airborne Arctic Stratospheric Expedition DC-8 flight of January 31, 1989. This flight leg was roughly aligned with air parcel motion on isentropic surfaces from 400-500 K, where the local adiabatic cooling rate was about 20 K/day. Type 1 PSCs show low depolarization ratios and scattering ratios which approach intermediate limiting values as ambient temperature decreases. These data suggest that Type 1 particles formed by rapid cooling may be nearly spherical and are restricted in size by partitioning of a limited HNO3 vapor supply among many competing growth sites. Type 2 PSCs appear at temperatures below estimated local frost points with increases in depolarization and scattering typical of larger ice crystals.

Poole, L. R.↗

Evidence for two different structuring and scattering mechanisms and the associated role of aerosols in the polar summer mesosphere

A Super Arcas rocket, MISTI B, was launched as part of the Polar Mesospheric Summer Echoes (PMSE) salvo to measure electron density irregularities using rf and dc probes. Large and small scale structures in the electron density were measured on rocket ascent and descent at the altitudes of 86.5 and 88.5 +/- .5 km. Since the rocket apogee was 89 km, the rocket was in the height range 88.5 +/- .5 km for 30 seconds giving us an unusual measurement of horizontal structure over a distance of 5.5 km. A power spectrum of the fluctuations for the upper layer gives further evidence that turbulent mixing is an important process in PMSE. The power spectrum of the lower layer, however, gives evidence that this layer is characterized by a form of partial or Fresnel scattering. Both spectra are in excellent agreement with similar analysis of electron fluctuation spectra measured in the same layers on the TURBO-B rocket flown 12 minutes later and the analysis of Cornell University Portable Radar Interferometer (CUPRI) data by Cho et al., 1993A. Thus two different structuring and scattering mechanisms exist at altitudes only 1 km apart. Using the simultaneous dc and rf probe measurements of electron depletions and sharp gradients in the lower layer, we speculate on the role of aerosols in creating these depletions and gradients.

Ulwick, J. C.↗

Analysis of the new polarimeter for the Marshall Space Flight Center vector magnetograph

The magnetograph was upgraded in both electronic control of the magnetograph hardware and in the polarization optics. The problems associated with the orignal polarimeter were: (1) field of view errors associated with the natural birefringence of the KD*P crystals; (2.) KD*P electrode failure due to the halfwave dc voltage required in one of the operational sequences; and (3) breakdown of the retardation properties of some KD*Ps when exposed to a zero to halfwave modulation (DC) scheme. The new polarimeter gives up the flexibility provided by two variable waveplates to adjust the retardances of the optics for a particular polarization measurement, but solves the problems associated with the original polarimeter. With the addition of the quartz quarterwave plates, a new optical alignment was developed to allow the remaining KD*P to correct for errors in the waveplates. The new optical alignment of the polarimeter is prescribed. The various sources of error, and how those errors are minimized so that the magnetograph can look at the transverse field in real time are discussed.

West, E. A.↗

Large-volume CdZnTe bar detectors characterized by laser-induced transient currents

In this work, we studied the free-carrier transport properties and space-charge formation/polarization in a CdZnTe bar-shaped radiation detector using the Laser-Induced Transient Current technique. We found out that a steady-state space charge ranging from 8 x 10 8 to 2.1 x 10 9 cm -3 is formed throughout the detector at about 0.5 s following biasing. The measured current waveforms were modeled by Monte Carlo simulations after taking into account the electric and weighting fields inside the detector and shielding box. Modeling of the unpolarized waveforms revealed an exceptionally high electron mobility-lifetime product μ e τ e ≥0.095cm 2 V -1 . The observed formation of positive space charge in the biased detector and linear scaling of the current waveform shapes on applied bias revealed that the detector polarization is attributed to carrier injection at the anode. In conclusion, measurements in pulsed and DC bias in modified electrode geometry proved the surface-charge formation.

47 OTHER INSTRUMENTATION↗

Nonreciprocal reflection-beam isolators for far-infrared use

Magnetoplasma reflection-beam isolators for submillimeter-wave use are discussed in theory and experiment. The basic device uses the Kerr transverse magnetooptic effect (plane of polarization of the EM wave in the plane of incidence, which is perpendicular to a dc magnetic field) in InSb near room temperature. When the semiconductor slab is covered with a thin dielectric layer acting as a matching transformer, improved performance is predicted and observed at 337 microns, and very efficient isolator performance is predicted for 118 microns. Physical arguments are presented to explain the nonreciprocal phenomenon and lead to better device design.

Kanda, M.↗

Comparison of column abundances from three infrared spectrometers during AASE 2

Three Fourier transform infrared (FTIR) spectromenters were based on board the NASA DC-8 during the second Airborne Arctic Stratospheric Expedition (AASE II) in 1992. Two FTIRs used solar absorption and one used thermal emission. We compare over 2000 measurements from these 3 FTIRs, on 12 DC-8 flights, for closely coincident air masses and times, both inside and outside the polar vortex. In the majority of cases the offset biases are quite small, in the range 1-4%, and comparable to the absolute precisions expected. In most cases the rms scatter is in the range 4-11%; this scatter is unlikely to be geophysical, but rather is probably instrumental or analytical in origin.

Traub, W. A.↗

An Assessment of the Ozone Loss During the 1999-2000 SOLVE Arctic Campaign

Ozone observations from ozonesondes, the lidars aboard the DC-8, in situ ozone measurements from the ER-2, and satellite ozone measurements from Polar Ozone and Aerosol Measurement III (POAM) were used to assess ozone loss during the Sage III Ozone Loss and Validation Experiment (SOLVE) 1999-2000 Arctic campaign. Two methods of analysis were used. In the first method a simple regression analysis is performed on the ozonesonde and POAM measurements within the vortex. In the second method, the ozone measurements from all available ozone data were injected into a free running diabatic trajectory model and carried forward in time from December 1 to March 15. Vortex ozone loss was then estimated by comparing the ozone values of those parcels initiated early in the campaign with those parcels injected later in the campaign. Despite the variety of observational techniques used during SOLVE, the measurements provide a fairly consistent picture. Over the whole vortex, the largest ozone loss occurs between 550 and 400 K potential temperatures (approximately 23-16 km) with over 1.5 ppmv lost by March 15, the end of the SOLVE mission period. An ozone loss rate of 0.04-0.05 ppmv/day was computed for March 15. Ozonesondes launched after March 15 suggest that an additional 0.5 ppmv or more ozone was lost between March 15 and April 1. The small disagreement between ozonesonde and POAM analysis of January ozone loss is found to be due to biases in vortex sampling. POAM makes most of its solar occultation measurements at the vortex edge during January 2000 which bias samples toward air parcels that have been exposed to sunlight and likely do experience ozone loss. Ozonesonde measurements and the trajectory technique use observations that are more distributed within the interior of the vortex. Thus the regression analysis of the POAM measurements tends to overestimate mid-winter vortex ozone loss. Finally, our loss calculations are broadly consistent with other loss computations using ER-2 tracer data and MLS satellite data, but we find no evidence for the 1992 high mid-January loss reported using the Match technique.

Schoeberl, Mark R.↗

Aerosol Optical Depth Measurements by Airborne Sun Photometer in SOLVE II: Comparisons to SAGE III, POAM III and Airborne Spectrometer Measurements

The 14-channel NASA Ames Airborne Tracking Sunphotometer (AATS-14) measured solar-beam transmission on the NASA DC-8 during the Second SAGE III Ozone Loss and Validation Experiment (SOLVE II). This paper presents AATS-14 results for multiwavelength aerosol optical depth (AOD), including its spatial structure and comparisons to results from two satellite sensors and another DC-8 instrument. These are the Stratospheric Aerosol and Gas Experiment III (SAGE III), the Polar Ozone and Aerosol Measurement III (POAM III) and the Direct beam Irradiance Airborne Spectrometer (DIAS).

Russell, P.↗

Retrieval of Ozone Column Content from Airborne Sun Photometer Measurements During SOLVE II: Comparison with SAGE III, POAM III,THOMAS and GOME Measurements

During the Second SAGE 111 Ozone Loss and Validation Experiment (SOLVE II), the 14- channel NASA Ames Airborne Trackmg Sunphotometer (AATS-14) was mounted on the NASA DC-8 and successfully measured spectra of total and aerosol optical depth (TOD and AOD) during the sunlit portions of eight science flights. Values of ozone column content above the aircraft have been derived from the AATS-14 data by using a linear least squares method. For each AATS-14 measured TOD spectrum, this method iteratively finds the ozone column content that yields the best match between measured and calculated TOD. The calculations assume the known Chappuis ozone band shape and a three-parameter AOD shape (quadratic in log-log space). Seven of the AATS-14 channels (each employing an interference filter with a nominal full-width at half maximum bandpass of -5 nm) are within the Chappuis band, with center wavelengths between 452.9 nm and 864.5 nm. One channel (604.4 nm) is near the peak, and three channels (499.4, 519.4 and 675.1 nm) have ozone absorption within 30-40% of that at the peak. For the typical DC-8 SOLVE II cruising altitudes of approx. 8-12 km and the background stratospheric aerosol conditions that prevailed during SOLVE 11, absorption of incoming solar radiation by ozone comprised a significant fraction of the aerosol-plus-ozone optical depth measured in the four AATS-14 channels centered between 499.4 and 675.1 nm. Typical AODs above the DC-8 ranged from 0.003-0.008 in these channels. For comparison, an ozone overburden of 0.3 atm-cm (300 DU) translates to ozone optical depths of 0.009,0.014, 0.041, and 0.012, respectively, at these same wavelengths. In this paper, we compare AATS-14 values of ozone column content with temporally and spatially near-coincident values derived from measurements acquired by the Stratospheric Aerosol and Gas Experiment III (SAGE III) and the Polar Ozone and Aerosol Measurement 111 (POAM III) satellite sensors. We also compare AATS-14 ozone retrievals during selected DC-8 latitudinal and longitudinal transects with total column ozone data acquired by the Total Ozone Mapping Spectrometer (TOMS) and the Global Ozone Monitoring Experiment (GOME) satellite sensors. To enable this comparison, the amount of ozone in the column below the aircraft is estimated by combining SAGE and/or POAM data with high resolution, fast response in-situ ozone measurements acquired during the DC-8 ascent at the start of each science flight.

Livingston, J.↗

Photoinduced anomalous Hall effect in two-dimensional transition metal dichalcogenides

A circularly polarized ac pump field illuminated near resonance on two-dimensional transition metal dichalcogenides (TMDs) produces an anomalous Hall effect in response to a dc bias field. In this work, we develop a theory for this photoinduced anomalous Hall effect in undoped TMDs irradiated by a strong coherent laser field. The strong field renormalizes the equilibrium bands and opens up a dynamical energy gap where single-photon resonance occurs. The resulting photon dressed states, or Floquet states, are treated within the rotating-wave approximation. A quantum kinetic equation approach is developed to study the nonequilibrium density matrix and time-averaged transport currents under the simultaneous influence of the strong ac pump field and the weak dc probe field. Dissipative effects are taken into account in the kinetic equation that captures relaxation and dephasing. The photoinduced longitudinal and Hall conductivities display notable resonant signatures when the pump field frequency reaches the spin-split interband transition energies. Rather than valley polarization, we find that the anomalous Hall current is mainly driven by the intraband response of photon-dressed electron populations near the dynamical gap at both valleys, accompanied by a smaller contribution due to the interband response. In conclusion, these findings highlight the importance of photon-dressed bands and nonequilibrium distribution functions in achieving a proper understanding of the photoinduced anomalous Hall effect in a strong pump field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ozone Loss From Quasi-Conservative Coordinate Mapping During the 1999-2000 SOLVE Campaign

During the winter of 1999-2000, the Sage III Ozone Loss and Validation Experiment (SOLVE) field experiment took place in Kiruna, Sweden. The purpose of SOLVE was to examine ozone depletion mechanisms in the Arctic stratosphere (from about 10 to 50 km altitude) during the winter and early spring, when a band of strong winds (the 'polar vortex') circle the pole. Measurements of stratospheric ozone were made by several different kinds of instruments in different meteorological situations. We analyzed these data using the 'quasi-conservative coordinate mapping' technique, in which the measurements are analyzed in terms of meteorological properties ('potential temperature' and 'potential vorticity') which tend not to change very much over a few days. This technique reduces or removes the changes that are associated with the polar vortex moving around. Over longer time periods, potential temperature and potential vorticity change as air cools and descends within the polar vortex. We account for these changes by calculating the trajectories of air parcels, and this enables us to extend the analysis over a ten-week period from January 10 to March 17, 2000. Using data from the NASA ER-2 aircraft, from the DIAL and AROTEL laser sounders on the NASA DC-8 aircraft, and balloon-borne ozonesondes, our analysis reveals changes in ozone which, because we have removed the effects of polar vortex motion and the descending air, indicate chemical destruction of ozone in early 2000. We find a peak decline rate of approximately 0.03 ppmv/day near 470 K of potential temperature (near 20 km) in mid-January which sinks in altitude to around 440 K (near 18 km) in mid-March.

Lait, L. R.↗

A Composite View of Ozone Evolution in the 1995-96 Northern Winter Polar Vortex Developed from Airborne Lidar and Satellite Observations

The processes which contribute to the ozone evolution in the high latitude lower stratosphere are evaluated using a three dimensional model simulation and ozone observations. The model uses winds and temperatures from the Goddard Earth Observing System Data Assimilation System. The simulation results are compared with ozone observations from three platforms: the differential absorption lidar (DIAL) which was flown on the NASA DC-8 as part of the Vortex Ozone Transport Experiment; the Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite; and the Polar Ozone and Aerosol Measurement (POAM II) solar occulation instrument, on board the French Satellite Pour I'Observations de la Terre. Comparisons of the different data sets with the model simulation are shown to provide complementary information and a consistent view of the ozone evolution. The model ozone in December and January is shown to be sensitive to the ozone vertical gradient and the model vertical transport, and only weakly sensitive to the model photochemistry. The most consistent comparison between observed and modeled ozone evolution is found for a simulation where the vertical profiles between 12 and 20 km within the polar vortex closely match December DIAL observations. Diabatic trajectory calculations are used to estimate the uncertainty due to vertical advection quantitatively. The transport uncertainty is significant, and should be accounted for when comparing observations with model ozone. The model ozone evolution during December and January is broadly consistent with the observations when these transport uncertainties are taken into account.

Douglass, Anne R.↗

Vertical Structure of Stratiform Rain During TEFLUN-B and TRMM-LBA as Derived From an Airborne Radar Perspective

The NASA aircraft instrumented with airborne radars overflew a number of stratiform rain systems during the Texas and Florida Underflights Experiment-B TEFLUN-B) and TRMM-LBA (LBA). TEFLUN-B was conducted near Melbourne Florida during late Summer 1998 for validation of the TRMM satellite. LBA was conducted in Rondonia, Brazil in the Amazon region. Key in these campaigns were the ER-2 and DC-8 aircraft, as well as extensive ground-validation networks including the NCAR S-band (S-POL) polarization radar and University of North Dakota Citation II in situ microphysics measurements. This paper compares the vertical structure of precipitation and vertical motions for four cases: 5 September 1998 and 13 August 1998 during TEFLUN-B and 17 February 1999 and 21 February 1999 during LBA. Both these stratiform systems were within close range of the S-POL radar, and were sampled with downlooking radars and radiometers on the ER-2 (and DC-8 during LBA). Emphasis in the paper is on statistics of the vertical hydrometeor profiles, and their relation to the vertical velocity structure deduced from the ER-2 Doppler Radar (EDOP) measurements. These profiles are used to identify whether growth regions exist as would be expected with mesoscale updrafts often associated with stratiform regions. Finally, rain rates in the stratiform rain derived from EDOP and S-POL are compared.

Heymsfield, Gerald M.↗