Search NASA⌕ Search

SEARCH · Search NASA

Results for “decimated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Canopus: A Paradigm Shift Towards Elastic Extreme-Scale Data Analytics on HPC

Scientific simulations on high performance computing (HPC) platforms generate large quantities of data. To bridge the widening gap between compute and I/O, and enable data to be more efficiently stored and analyzed, simulation outputs need to be refactored, reduced, and appropriately mapped to storage tiers. However, a systematic solution to support these steps has been lacking on the current HPC software ecosystem. To that end, this paper develops Canopus, a progressive JPEGlike data management scheme for storing and analyzing big scientific data. It co-designs the data decimation, compression and data storage, taking the hardware characteristics of each storage tier into considerations. With reasonably low overhead, our approach refactors simulation data into a much smaller, reduced-accuracy base dataset, and a series of deltas that is used to augment the accuracy if needed. The base dataset and deltas are compressed and written to multiple storage tiers. Data saved on different tiers can then be selectively retrieved to restore the level of accuracy that satisfies data analytics. Thus, Canopus provides a paradigm shift towards elastic data analytics and enables end users to make trade-offs between analysis speed and accuracy on-the-fly. We evaluate the impact of Canopus on unstructured triangular meshes, a pervasive data model used by scientific modeling and simulations. In particular, we demonstrate the progressive data exploration of Canopus using the “blob detection” use case on the fusion simulation data.

Lu, Tao↗

Hf‐W chronology of a macrochondrule from the L5/6 chondrite Northwest Africa 8192

Abstract A large, igneous‐textured, and 2 cm‐sized spherical object from the L5/6 chondrite NWA 8192 was investigated for its chemical composition, petrography, O isotopic composition, and Hf‐W chronology. The petrography and chemical data indicate that this object closely resembles commonly found chondrules in ordinary chondrites and is therefore classified as a “macrochondrule.* As a result of metal loss during its formation, the macrochondrule exhibits elevated Hf/W, which makes it possible to date this object using the short‐lived 182 Hf‐ 182 W system. The Hf‐W data provide a two‐stage model age for metal–silicate fractionation of 1.4 ± 0.6 Ma after Ca‐Al‐rich inclusion (CAI) formation, indicating that the macrochondrule formed coevally to normal‐sized chondrules from ordinary chondrites. By contrast, Hf‐W data for metal from the host chondrite yield a younger model age of ~11 Ma after CAIs. This younger age agrees with Hf‐W ages of other type 5–6 ordinary chondrites, and corresponds to the time of cooling below the Hf‐W closure temperature during thermal metamorphism on the parent body. The Hf‐W model age difference between the macrochondrule and the host metal demonstrates that the Hf‐W systematics of the bulk macrochondrule were not disturbed during thermal metamorphism, and therefore, that the formation age of such objects can still be determined even in strongly metamorphosed samples. Collectively, this study illustrates that chondrule formation was not limited to mm‐size objects, implying that the rarity of macrochondrules reflects either that this process was very inefficient, that subsequent nebular size‐sorting decimated large chondrules, or that large precursors were rare.

58 GEOSCIENCES↗

Monitoring critical facilities by using advanced RF devices

The ability to monitor critical environment parameters of nuclear plants at all times, particularly during and after a disruptive accident, is vital for the safety of plant personnel, rescue and recovery crews, and the surrounding communities. Conventional hard-wired assets that depend on supplied power may be decimated as a result of such events, as witnessed in the Japanese Fukushima nuclear power plant in March 2011. Self-powered monitoring devices operating on a wireless platform, on the other hand, may survive such calamity and remain functional. The devices would be pre-positioned at strategic locations, particularly where the dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance. Equipped with sensors for β-γ radiation, neutrons, hydrogen gas, temperature, humidity, pressure, and water level, as well as with criticality alarms and imaging equipment for heat, video, and other capabilities, these devices can provide vital surveillance information for assessing the extent of plant damage, mandating responses (e.g., evacuation before impending hydrogen explosion), and enabling overall safe and efficient recovery in a disaster. A radio frequency identification (RFID)-based system - called ARG-US - may be modified and adapted for this task. Developed by Argonne for DOE, ARG-US (meaning 'watchful guardian') has been used successfully to monitor and track sensitive nuclear materials packages at DOE sites. It utilizes sensors in the tags to continuously monitor the state of health of the packaging and promptly disseminates alarms to authorized users when any of the preset sensor thresholds is violated. By adding plant-specific monitoring sensors to the already strong sensor suite and adopting modular hardware, firmware, and software subsystems that are tailored for specific subsystems of a plant, a Remote Area Modular Monitoring (RAMM) system, built on a wireless sensor network (WSN) platform, is being developed by Argonne National Laboratory. ARG-US RAMM, powered by on-board battery, can sustain extended autonomous surveillance operation during and following an incident. The benefits could be invaluable to such critical facilities as nuclear power plants, research and test reactors, fuel cycle manufacturing centers, spent-fuel dry-cask storage facilities, and other nuclear installations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accuracy of pencil-beam redefinition algorithm dose calculations in patient-like cylindrical phantoms for bolus electron conformal therapy

Purpose: The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer.Methods: PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom. A bolus was designed using the planning.decimal{sup Registered-Sign} (p.d) software (.decimal, Inc., Sanford, FL) to conform the 90% dose line to the distal surface of the PTV. Dose measurements were taken with thermoluminescent dosimeters placed into predrilled holes. The Pinnacle{sup 3} (Philips Healthcare, Andover, MD) treatment planning system was used to calculate PBA dose distributions. The PBRA dose distributions were calculated with an in-house C++ program. In order to accurately account for the phantom materials a table correlating CT number to relative electron stopping and scattering powers was compiled and used for both PBA and PBRA dose calculations. Accuracy was determined by comparing differences in measured and calculated dose, as well as distance to agreement for each measurement point.Results: The measured doses had an average precision of 0.9%. For the retromolar trigone phantom, the PBRA dose calculations had an average {+-}1{sigma} dose difference (calculated - measured) of -0.65%{+-} 1.62% without the bolus and -0.20%{+-} 1.54% with the bolus. The PBA dose calculation had an average dose difference of 0.19%{+-} 3.27% without the bolus and -0.05%{+-} 3.14% with the bolus. For the nose phantom, the PBRA dose calculations had an average dose difference of 0.50%{+-} 3.06% without bolus and -0.18%{+-} 1.22% with the bolus. The PBA dose calculations had an average dose difference of 0.65%{+-} 6.21% without bolus and 1.75%{+-} 5.94% with the bolus. From a clinical perspective an agreement of 5% or better between planned (calculated) and delivered (measured) dose is desired. Statistically, this was true for 99% ({+-}2{sigma}) of the dose points for three of the four cases for the PBRA dose calculations, the exception being the nose without bolus for which this was true for 89% ({+-}1.6{sigma}) of the dose points. For the retromolar trigone, with and without bolus, the PBA showed agreement of 5% or better for approximately 86% ({+-}1.5{sigma}) of the dose points. For the nose, with and without bolus, the PBA showed agreement of 5% or better for only approximately 58% ({+-}0.8{sigma}) of the dose points.Conclusions: The measured data, whose high precision makes them useful for evaluation of the accuracy of electron dose algorithms, will be made publicly available. Based on the spread in dose differences, the PBRA has at least twice the accuracy of the PBA. From a clinical perspective the PBRA accuracy is acceptable in the retromolar trigone and nose for electron therapy with and without bolus.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy

Purpose: To evaluate the neutron and photon dose equivalent rates at the treatment vault entrance (H{sub n,D} and H{sub G}), and to study the secondary radiation to the patient in GRID therapy. The radiation activation on the grid was studied.Methods: A Varian Clinac 23EX accelerator was working at 18 MV mode with a grid manufactured by .decimal, Inc. The H{sub n,D} and H{sub G} were measured using an Andersson–Braun neutron REM meter, and a Geiger Müller counter. The radiation activation on the grid was measured after the irradiation with an ion chamber γ-ray survey meter. The secondary radiation dose equivalent to patient was evaluated by etched track detectors and OSL detectors on a RANDO{sup ®} phantom.Results: Within the measurement uncertainty, there is no significant difference between the H{sub n,D} and H{sub G} with and without a grid. However, the neutron dose equivalent to the patient with the grid is, on average, 35.3% lower than that without the grid when using the same field size and the same amount of monitor unit. The photon dose equivalent to the patient with the grid is, on average, 44.9% lower. The measured average half-life of the radiation activation in the grid is 12.0 (±0.9) min. The activation can be categorized into a fast decay component and a slow decay component with half-lives of 3.4 (±1.6) min and 15.3 (±4.0) min, respectively. There was no detectable radioactive contamination found on the surface of the grid through a wipe test.Conclusions: This work indicates that there is no significant change of the H{sub n,D} and H{sub G} in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam delivery is suggested.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-356: Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10{sup 9}), resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-641: Development and Verification of Automatic Reading Dose of Interest From Eclipse's DVH

Purpose: According to clinical and research requirement, we develop a function of automatic reading dose of interest from dose volume histogram(DVH), to replace the traditional method with a mouse one by one point, and it's also verified. Methods: The DVH automatic reading function will be developed in an in-house developed radiotherapy information management system(RTIMS), which is based on Apache+PHP+MySQL. A DVH ASCII file is exported from Varian Eclipse V8.6, which includes the following contents: 1. basic information of patient; 2. dose information of plan; 3. dose information of structures, including basic information and dose volume data of target volume and organ at risk. And the default exported dose volume data also includes relative doses by 1% step and corresponding absolute doses and cumulative relative volumes, and the volumes are 4 decimal fraction. Clinically, we often need read the doses of some integer percent volumes, such as D50 and D30. So it couldn't be directly obtained from the above data, but we can use linear interpolation bye the near volumes and doses: Dx=D2−(V2−Vx)*(D2−D1)/(V2−V1), and program a function to search, read and calculate the corresponding data. And the doses of all preseted volume of interest of all structures can be automatically read one by one patient, and saved as a CSV file. To verify it, we select 24 IMRT plans for prostate cancer, and doses of interest are PTV D98/D95/D5/D2, bladder D30/D50, and rectum D25/D50. Two groups of data, using the automatic reading method(ARM) and pointed dose method(PDM), are analyzed with SPSS 16. The absolute difference=D-ARM-D-PDM, relative difference=absolute difference*100%/prescription dose(7600cGy). Results: The differences are as following: PTV D98/D95/D5/D2: −0.04%/− 0.04%/0.13%/0.19%, bladder D30/D50: −0.02%/0.01%, and rectum D25/D50: 0.03%/0.01%. Conclusion: Using this function, the error is very small, and can be neglected. It could greatly improve the efficiency of clinical work. Project supported by the National Natural Science Foundation of China (Grant No.81101694)

60 APPLIED LIFE SCIENCES↗

SU-D-210-05: The Accuracy of Raw and B-Mode Image Data for Ultrasound Speckle Tracking in Radiation Therapy

Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation template matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion would also be prudent. This work is support by Cancer Research UK Programme Grant C33589/A19727.

60 APPLIED LIFE SCIENCES↗

SU-F-T-189: Dosimetric Comparison of Spot-Scanning Proton Therapy Techniques for Liver Tumors Close to the Skin Surface

Purpose: Spot-scanning technique has been utilized to achieve conformal dose distribution to large and complicated tumors. This technique generally does not require patient-specific devices such as aperture and compensator. The commercially available spot-scanning proton therapy (SSPT) systems, however, cannot deliver proton beams to the region shallower than 4 g/cm2. Therefore some range compensation device is required to treat superficial tumors with SSPT. This study shows dosimetric comparison of the following treatment techniques: (i) with a tabletop bolus, (ii) with a nozzle-mounted applicator, and (iii) without any devices and using intensity-modulated proton therapy (IMPT) technique. Methods: The applicator composed of a combination of a mini-ridge filter and a range shifter has been manufactured by Hitachi, Ltd., and the tabletop bolus was made by .decimal, Inc. Both devices have been clinically implemented in our facility. Three patients with liver tumors close to the skin surface were examined in this study. Each treatment plan was optimized so that the prescription dose of 76 Gy(RBE) or 66 Gy(RBE) would be delivered to 99% of the clinical target volume in 20 fractions. Three beams were used for tabletop bolus plan and IMPT plan, whereas two beams were used in the applicator plan because the gantry angle available was limited due to potential collision to patient and couch. The normal liver, colon, and skin were considered as organs at risk (OARs). Results: The target heterogeneity index (HI = D{sub 5}/D{sub 95}) was 1.03 on average in each planning technique. The mean dose to the normal liver was considerably less than 20 Gy(RBE) in all cases. The dose to the skin could be reduced by 20 Gy(RBE) on average in the IMPT plan compared to the applicator plan. Conclusion: It has been confirmed that all treatment techniques met the dosimetric criteria for the OARs and could be implemented clinically.

60 APPLIED LIFE SCIENCES↗

Electronic structure at coarse-grained resolutions from supervised machine learning

Computational studies aimed at understanding conformationally dependent electronic structure in soft materials require a combination of classical and quantum-mechanical simulations, for which the sampling of conformational space can be particularly demanding. Coarse-grained (CG) models provide a means of accessing relevant time scales, but CG configurations must be back-mapped into atomistic representations to perform quantum-chemical calculations, which is computationally intensive and inconsistent with the spatial resolution of the CG models. A machine learning approach, denoted as artificial neural network electronic coarse graining (ANN-ECG), is presented here in which the conformationally dependent electronic structure of a molecule is mapped directly to CG pseudo-atom configurations. By averaging over decimated degrees of freedom, ANN-ECG accelerates simulations by eliminating backmapping and repeated quantum-chemical calculations. The approach is accurate, consistent with the CG spatial resolution, and can be used to identify computationally optimal CG resolutions.

36 MATERIALS SCIENCE↗

Scattering of an exciton polariton by impurity centers in GaAs

Scattering of an exciton polariton by impurity centers at low temperatures has not been investigated comprehensively in spite of its significant role in processes accompanying Bose–Einstein condensation of an exciton polariton. For studying the peculiarities of the interaction of an exciton polariton with impurity centers, we have studied the integrated absorption of the ground state (n{sub 0} = 1) of the exciton in GaAs in thin (micrometer-thick) wafers with an appreciable optical transmission. Comparative analysis of the transmission in the vicinity of the exciton resonance performed on 15 samples of crystalline GaAs wafers with different concentrations N of impurity has revealed an unexpected regularity. The value of N increases by almost five decimal orders of magnitude, while the normalized spectrally integrated absorption of light exhibits a slight increase, following the power dependence N{sup m} on the concentration, where m = 1/6. It has been shown that this dependence indicates the diffusion mechanism of propagation of the exciton polaritons through the bulk of the semiconductor, which is present along with the ballistic propagation of light through the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Misanthropic entropy and renormalization as a communication channel

A central physical question is the extent to which infrared (IR) observations are sufficient to reconstruct a candidate ultraviolet (UV) completion. We recast this question as a problem of communication, with messages encoded in field configurations of the UV being transmitted to the IR degrees of freedom via a noisy channel specified by renormalization group (RG) flow, with noise generated by coarse graining/decimation. We present an explicit formulation of these considerations in terms of lattice field theory, where we show that the “misanthropic entropy” — the mutual information obtained from decimating neighbors — encodes the extent to which information is lost in marginalizing over/tracing out UV degrees of freedom. Our considerations apply both to statistical field theories as well as density matrix renormalization of quantum systems, where in the quantum case, the statistical field theory analysis amounts to a leading-order approximation. As a concrete example, we focus on the case of the 2D Ising model, where we show that the misanthropic entropy detects the onset of the phase transition at the Ising model critical point.

Physics↗

Seismic Analysis Code 2000

The Seismic Analysis Code (SAC2000) is a general purpose interactive program designed for the study of sequential signals, especially time-series data. Emphasis has been placed on analysis tools used by research seismologists in the detailed study of seismic events. Analysis capabilities include general arithmetic operations, Fourier transforms, spectral estimation techniques, IIR and FIR filtering, signal stacking, decimation, interpolation, correlation, and seismic phase picking. SAC2000 also contains an extensive graphics capability. Versions are available for a wide variety of computer systems. SAC2000 was developed at Lawrence Livermore National Laboratory.

Barno, Justin↗

Utah FORGE: Phase 1a Tensor Strainmeter Data for the April, 2022 Stimulation of Well 16A(78)-32

Data from two Tensor Optical Fiber Strainmeters that were operational during Stages 1, 2, and 3 of the April, 2022 stimulation of well 16A(78)-32. Each csv file contains data from each stimulation stage (stage1, stage2, stage3) for both Phase 1a strainmeter installations (FS01, formerly FS-C, and FS02, formerly FS1-2) in human-readable comma-separated value text files. There are two header lines in each file describing the data contained in that column along with their units, respectively. Data have been decimated from 2 to 1 Hz to match the Pason data found in the linked GDR dataset below (16A78-32 Stimulation Pason Data). These files contain the time series spanning the same time interval as the Pason data as well as ambient data for 5 hours before the stimulation and 5 hours following shut in. The station locations were chosen based on their proximity to the borehole seismometers owned and operated by the University of Utah. See README.txt for more information.

15 GEOTHERMAL ENERGY↗

CODAS Data from Oliktok Point, Beaufort Sea, Alaska

Cryosphere/Ocean Distributed Acoustic Sensing (CODAS) data collected from the Beaufort Sea, Alaska, using ~37.4 km of dark telecommunications fiber located at Oliktok Point, Alaska. Data were collected with a Silixa iDAS, using 10 m gauge length, 2 m spatial resolution, and 1000 Hz sample rate. Provided here are the DAS-recorded time series for the rapid refreeze event described in Baker & Abbott (2022) (see link below). This covers a date range of 2021-11-10 15:00 UTC to 2021-11-11 17:00 UTC. Data have been decimated to 100 Hz and 20 m (i.e., every 10th channel for 1831 channels, total), as used in Baker & Abbott (2022). Data have been extracted from raw format into 1-hour long .sac* files and organized into directories by channel number, spanning channels 100 to 18400. Time series units are nano-strainrate (nm/m/s). For distribution, data have been compressed into .zip files containing all time series files for 100 channels. *For information on the Seismic Analysis Code (SAC) file format: https://seiscode.iris.washington.edu/projects/sac

16 TIDAL AND WAVE POWER↗

Experimental Study of a Single Electron in a Storage Ring via Undulator Radiation

A single electron orbiting around a ring and emitting single quanta at the rate of about one event per hundred turns could produce a wealth of information about physical processes in large traps (i.e. storage rings) for charged particles. It should be noted that Paul and Penning traps in the 1980s led to the Nobel prize for studying state and motion of single quantum particles, and just recently the Penning trap technique has enabled the measurement of a single proton magnetic moment with an unprecedented precision of 10 decimal places. The information from the storage ring traps could also be used for characterization of a quantum system as well as the "trap" itself, i.e. measuring properties of the storage ring lattice and electron interaction with the laser fields. Although, the interest in single electron quantum processes today is mostly academic in nature, the diagnostics and methodology developed for single electron radiation studies could find subsequent applications in a variety of applied disciplines in quantum technology, including quantum communications and quantum computing.

43 PARTICLE ACCELERATORS↗

Dimensionally Aligned Signal Projection Algorithms Library

Dimensionally aligned signal projection (DASP) algorithms are used to analyze fast Fourier transforms (FFTs) and generate visualizations that help focus on the harmonics for specific signals. At a high level, these algorithms extract the FFT segments around each harmonic frequency center, and then align them in equally sized arrays ordered by increasing distance from the base frequency. This allows for a focused view of the harmonic frequencies, which, among other use cases, can enable machine learning algorithms to more easily identify salient patterns. This work seeks to provide an effective open-source implementation of the DASP algorithms proposed by Vann et al. (2018) as well as functionality to help explore and test how these algorithms work with an interactive dashboard and signal-generation tool. The DASP library is implemented in Python and contains four types of algorithms for implementing these feature engineering techniques: fixed harmonically aligned signal projection (HASP), decimating HASP, interpolating HASP, and frequency aligned signal projection (FASP). Each algorithm returns a numerical array, which can be visualized as an image. The HASP algorithms are variations of the algorithms originally presented by Vann et al. (2018). For consistency, FASP, which is the terminology used for the short-time Fourier transform (STFT), has been implemented as part of the library to provide a similar interface to the STFT of the raw signal. Additionally, the library contains an algorithm to generate artificial signals with basic customizations such as the base frequency, sample rate, duration, number of harmonics, noise, and number of signals. Finally, the library provides multiple interactive visualizations, each of which is implemented using IPyWidgets and works in a Jupyter environment. A dashboard-style visualization is provided, which contains some common signal-processing visual components (signal, FFT, spectogram) updating in unison with the HASP functions (see Figure 1 below). Separate from the dashboard, an independent visualization is provided for each of the DASP algorithms as well as for the artifical signal generator. These visualizations are included in the library to aid in developing an intuitive understanding how the algorithms are affected by different input signals and parameter selections.

harmonics↗

Hanford External Dosimetry Technical Basis Manual PNL-MA-842

The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanford’s DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNL’s Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Maintenance and distribution of controlled hard copies of the manual by PNNL was discontinued beginning with Revision 0.2.

61 RADIATION PROTECTION AND DOSIMETRY↗