Search NASA⌕ Search

SEARCH · Search NASA

Results for “deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multi-images deconvolution improves signal-to-noise ratio on gated stimulated emission depletion microscopy

Time-gated detection, namely, only collecting the fluorescence photons after a time-delay from the excitation events, reduces complexity, cost, and illumination intensity of a stimulated emission depletion (STED) microscope. In the gated continuous-wave- (CW-) STED implementation, the spatial resolution improves with increased time-delay, but the signal-to-noise ratio (SNR) reduces. Thus, in sub-optimal conditions, such as a low photon-budget regime, the SNR reduction can cancel-out the expected gain in resolution. Here, we propose a method which does not discard photons, but instead collects all the photons in different time-gates and recombines them through a multi-image deconvolution. Our results, obtained on simulated and experimental data, show that the SNR of the restored image improves relative to the gated image, thereby improving the effective resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data-driven deconvolution for large eddy simulations of Kraichnan turbulence

In this article, we demonstrate the use of artificial neural networks as optimal maps which are utilized for convolution and deconvolution of coarse-grained fields to account for sub-grid scale turbulence effects. Here, we demonstrate that an effective eddy-viscosity is predicted by our purely data-driven large eddy simulation framework without explicit utilization of phenomenological arguments. In addition, our data-driven framework precludes the knowledge of true sub-grid stress information during the training phase due to its focus on estimating an effective filter and its inverse so that grid-resolved variables may be related to direct numerical simulation data statistically. The proposed predictive framework is also combined with a statistical truncation mechanism for ensuring numerical realizability in an explicit formulation. Through this, we seek to unite structural and functional modeling strategies for modeling non-linear partial differential equations using reduced degrees of freedom. Both a priori and a posteriori results are shown for a two-dimensional decaying turbulence case in addition to a detailed description of validation and testing. A hyperparameter sensitivity study also shows that the proposed dual network framework simplifies learning complexity and is viable with exceedingly simple network architectures. Our findings indicate that the proposed framework approximates a robust and stable sub-grid closure which compares favorably to the Smagorinsky and Leith hypotheses for capturing the theoretical k -3 scaling in Kraichnan turbulence.

42 ENGINEERING↗

PReBeaM FOR PLANCK: A POLARIZED REGULARIZED BEAM DECONVOLUTION MAP-MAKING METHOD

We describe a maximum-likelihood regularized beam deconvolution map-making algorithm for data from high-resolution, polarization-sensitive instruments, such as the Planck data set. The resulting algorithm, which we call PReBeaM, is pixel-free and solves for the map directly in spherical harmonic space, avoiding pixelization artifacts. While Fourier methods like ours are expected to work best when applied to smooth, large-scale asymmetric beam systematics (such as far-side lobe effects), we show that our m-truncated spherical harmonic representation of the beam results in negligible reconstruction error-even for m as small as 4 for a polarized elliptically asymmetric beam. We describe a hybrid OpenMP/MPI parallelization scheme which allows us to store and manipulate the time-ordered data from satellite instruments with a typical full-sky scanning strategy. Finally, we apply our technique to noisy data and show that it succeeds in removing visible power spectrum artifacts without generating excess noise on small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Deconvoluting sources of variability in aerosol jet printing using light scattering measurements

Aerosol jet printing (AJP) is a digital additive manufacturing technique for hybrid and conformal electronics, where its contactless deposition readily enables patterning over 3D surface topography. However, the complexity of aerosol transport physics makes deposition rate sensitive to process variability, hindering widespread industry adoption. Light scattering measurements have recently been demonstrated as a capable tool for measuring deposition rate in real time, enabling closed-loop control and in-situ qualification frameworks. These inline optical measurements present further opportunity as a diagnostic tool to understand the effects of secondary process parameters affecting vapor–liquid equilibrium and heat and mass transport during deposition. Downstream of the optical measurement cell, changing the sheath gas flow rate, increasing temperature via an inline heater, and adding solvent vapor via a sheath gas bubbler were observed to alter drying physics during sheath-collimation, and thereby impaction efficiency. Further upstream, the introduction of solvent vapor via a carrier gas bubbler and liquid build-up in the printhead were seen to affect the quantitative relationship between the light scattering data and the true deposition rate. Using this information, tightened controls of meaningful secondary parameters were implemented to improve the batch-to-batch consistency for printing a dielectric ink. In addition to advancing AJP process reliability for production, this work demonstrates the capability of inline optical measurements to provide insight into process physics and deconvolute competing mechanisms that underly variability.

additive manufacturing↗

Point spread function deconvolution using a convolutional autoencoder

A major issue in optical astronomical image analysis is the combined effect of the instrument’s point spread function (PSF) and the atmospheric seeing that blurs images and changes their shape in a way that is band and time-of-observation dependent. In this work we present a very simple neural network based approach to nonblind image deconvolution that relies on feeding a convolutional autoencoder (CAE) input images that have been preprocessed by convolution with the corresponding PSF and its regularized inverse, a method which is both conceptually simple and computationally less intensive. We also present here, a new approach for dealing with limited input dynamic range of neural networks compared to the dynamic range present in astronomical images.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-209: Independent Dose Calculation in FFF Modulated Fields with Pencil Beam Kernels Obtained by Deconvolution

Purpose: To obtain the pencil beam kernels that characterize a megavoltage photon beam generated in a FFF linac by experimental measurements, and to apply them for dose calculation in modulated fields. Methods: Several Kodak EDR2 radiographic films were irradiated with a 10 MV FFF photon beam from a Varian True Beam (Varian Medical Systems, Palo Alto, CA) linac, at the depths of 5, 10, 15, and 20cm in polystyrene (RW3 water equivalent phantom, PTW Freiburg, Germany). The irradiation field was a 50 mm diameter circular field, collimated with a lead block. Measured dose leads to the kernel characterization, assuming that the energy fluence exiting the linac head and further collimated is originated on a point source. The three-dimensional kernel was obtained by deconvolution at each depth using the Hankel transform. A correction on the low dose part of the kernel was performed to reproduce accurately the experimental output factors. The kernels were used to calculate modulated dose distributions in six modulated fields and compared through the gamma index to their absolute dose measured by film in the RW3 phantom. Results: The resulting kernels properly characterize the global beam penumbra. The output factor-based correction was carried out adding the amount of signal necessary to reproduce the experimental output factor in steps of 2mm, starting at a radius of 4mm. There the kernel signal was in all cases below 10% of its maximum value. With this correction, the number of points that pass the gamma index criteria (3%, 3mm) in the modulated fields for all cases are at least 99.6% of the total number of points. Conclusion: A system for independent dose calculations in modulated fields from FFF beams has been developed. Pencil beam kernels were obtained and their ability to accurately calculate dose in homogeneous media was demonstrated.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-69: Iterative Deconvolution of the Initial Photon Fluence for EPID Dosimetry: A Monte Carlo Based Study

Purpose: Developing a fast and accurate calculation model to reconstruct the applied photon fluence from an external photon radiation therapy treatment based on an image recorded by an electronic portal image device (EPID). Methods: To reconstruct the initial photon fluence the 2D EPID image was corrected for scatter from the patient/phantom and EPID to generate the transmitted primary photon fluence. This was done by an iterative deconvolution using precalculated point spread functions (PSF). The transmitted primary photon fluence was then backprojected through the patient/phantom geometry considering linear attenuation to receive the initial photon fluence applied for the treatment.The calculation model was verified using Monte Carlo simulations performed with the EGSnrc code system. EPID images were produced by calculating the dose deposition in the EPID from a 6 MV photon beam irradiating a water phantom with air and bone inhomogeneities and the ICRP anthropomorphic voxel phantom. Results: The initial photon fluence was reconstructed using a single PSF and position dependent PSFs which depend on the radiological thickness of the irradiated object. Appling position dependent point spread functions the mean uncertainty of the reconstructed initial photon fluence could be reduced from 1.13 % to 0.13 %. Conclusion: This study presents a calculation model for fluence reconstruction from EPID images. The{sup Result} show a clear advantage when position dependent PSF are used for the iterative reconstruction. The basic work of a reconstruction method was established and further evaluations must be made in an experimental study.

60 APPLIED LIFE SCIENCES↗

Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization

Purpose: Cerebral perfusion computed tomography (PCT) imaging as an accurate and fast acute ischemic stroke examination has been widely used in clinic. Meanwhile, a major drawback of PCT imaging is the high radiation dose due to its dynamic scan protocol. The purpose of this work is to develop a robust perfusion deconvolution approach via structure tensor total variation (STV) regularization (PD-STV) for estimating an accurate residue function in PCT imaging with the low-milliampere-seconds (low-mAs) data acquisition. Methods: Besides modeling the spatio-temporal structure information of PCT data, the STV regularization of the present PD-STV approach can utilize the higher order derivatives of the residue function to enhance denoising performance. To minimize the objective function, the authors propose an effective iterative algorithm with a shrinkage/thresholding scheme. A simulation study on a digital brain perfusion phantom and a clinical study on an old infarction patient were conducted to validate and evaluate the performance of the present PD-STV approach. Results: In the digital phantom study, visual inspection and quantitative metrics (i.e., the normalized mean square error, the peak signal-to-noise ratio, and the universal quality index) assessments demonstrated that the PD-STV approach outperformed other existing approaches in terms of the performance of noise-induced artifacts reduction and accurate perfusion hemodynamic maps (PHM) estimation. In the patient data study, the present PD-STV approach could yield accurate PHM estimation with several noticeable gains over other existing approaches in terms of visual inspection and correlation analysis. Conclusions: This study demonstrated the feasibility and efficacy of the present PD-STV approach in utilizing STV regularization to improve the accuracy of residue function estimation of cerebral PCT imaging in the case of low-mAs.

60 APPLIED LIFE SCIENCES↗

Multichannel deconvolution of vibrational signals: A state-space inverse filtering approach

Deconvolution of noisy measurements, especially when they are multichannel, has always been a challenging problem. The processing techniques developed range from simple Fourier methods to more sophisticated model-based parametric methodologies based on the underlying acoustics of the problem at hand. Methods relying on multichannel mean-squared error processors (Wiener filters) have evolved over long periods from the seminal efforts in seismic processing. However, when more is known about the acoustics, then model-based state-space techniques incorporating the underlying process physics can improve the processing significantly. The problems of interest are the vibrational response of tightly coupled acoustic test objects excited by an out-of-the-ordinary transient, potentially impairing their operational performance. Further, employing a multiple input/multiple output structural model of the test objects under investigation enables the development of an inverse filter by applying subspace identification techniques during initial calibration measurements. Feasibility applications based on a mass transport experiment and test object calibration test demonstrate the ability of the processor to extract the excitations successfully.

42 ENGINEERING↗

Deconvolution of Composition and Crystallite Size of Silver Hollandite Nanorods: Influence on Electrochemistry

In this paper, silver hollandite (Ag 1.4 Mn 8 O 16 ) has been synthesized by an aqueous, low-temperature co-precipitation technique to afford silver hollandite with distinct crystallite sizes (10 and 15 nm, identified as S-Ag 1.4 Mn 8 O 16 and L-Ag 1.4 Mn 8 O 16 , respectively) and equivalent silver content (x), allowing for the deconvolution of electrochemical effects related to crystallite size and silver content. The as-prepared silver hollandite materials were confirmed to be structurally analogous. Notably, TEM imaging reveals a high degree of bundling of S-Ag 1.4 Mn 8 O 16 nanorods compared to L-Ag 1.4 Mn 8 O 16 which facilitates more intimate connection of the S-Ag 1.4 Mn 8 O 16 material with enhanced interparticle contact. The electrochemical behavior and lithium diffusion properties were investigated by galvanostatic cycling, CV, electrochemical impedance, pulsed-discharge experiments, and ex-situ XAS analysis of cycled cathodes. Lithium based electrochemical cells containing S-Ag 1.4 Mn 8 O 16 delivered a capacity 15X higher than L-Ag 1.4 Mn 8 O 16 on cycle 1. Ex-situ XAS demonstrated structural change for S-Ag 1.4 Mn 8 O 16 and formation of Ag 0 on insertion of 3.8 Li + intercalation. However, the samples of L-Ag 1.4 Mn 8 O 16 were lithiated by a more limited 0.25 molar equivalents, where no significant structural changes were observed. Finally, the findings affirm crystallite size significantly impacts electrochemistry independent of cation occupancy of the α-MnO 2 type structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ FTIR Spectral Deconvolution [SWR-24-60]

In-situ FTIR Spectral Deconvolution contains scripts for the fitting of gaussians to convoluted FTIR spectra. It was specifically developed to handle a time-series of in situ ATR-FTIR spectra, split the spectra into its individual gaussians, and track those peaks as they shift in intensity and energy. Along with the actual fitting script, this repository contains several support scripts for data analysis and recall of prior fit results.

Tremolet de Villers, Bertrand↗

Denoised Wigner distribution deconvolution via low-rank matrix completion

Wigner distribution deconvolution (WDD) is a decades-old method for recovering phase from intensity measurements. Although the technique offers an elegant linear solution to the quadratic phase retrieval problem, it has seen limited adoption due to its high computational/memory requirements and the fact that the technique often exhibits high noise sensitivity. Here, we propose a method for noise suppression in WDD via low-rank noisy matrix completion. Our technique exploits the redundancy of an object’s phase space to denoise its WDD reconstruction. We show in model calculations that our technique outperforms other WDD algorithms as well as modern iterative methods for phase retrieval such as ptychography. Here, our results suggest that a class of phase retrieval techniques relying on regularized direct inversion of ptychographic datasets (instead of iterative reconstruction techniques) can provide accurate quantitative phase information in the presence of high levels of noise.

47 OTHER INSTRUMENTATION↗