Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

124 records · Page 7

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗

Comparison of In-situ Near Infrared Melt Pool Imagery to Optical Microscopy Measurements

Additive manufacturing (AM) is a rapidly growing technology. An area of major importance is the integrity and repeatability of AM parts. The goal is to reduce obstacles to certify AM built parts to allow for use in critical aerospace applications. In-situ nondestructive evaluation sensors can be used for build assessment and can potentially play a key role in certifying AM parts. For example, melt pool features are understood to have a strong correlation to microstructural defects and the use of a near infrared (NIR) camera can be used to record the melt pool, cooling areas, and temperature gradients during the build. This work explores the use of a low cost NIR camera to obtain single line track imagery of the Ti-6Al-4V melt pools for various processing parameters. The NIR camera is radiometrically calibrated and configured in-line with the laser source to obtain high resolution imagery of the melt pool shape and dynamics. The challenge to measure melt pool shapes is to identify the transition points between the metal solid to liquid phase. Factors for melt pool measurements such as thermal camera pixel resolution, surface emissivity, and blurring due to the laser beam movement are discussed. Lastly, the melt pool imagery are compared to optical microscopy measurements for validation.

additive manufacturing↗

N2 positive and N2/+/ band systems and the energy spectra of auroral electrons.

Use of the relative emission rates of the auroral N2 positive and N2(+) band systems to limit the permissible range of differential electron fluxes in auroras, due to remarkable differences in electron excitation functions for the two kinds of systems. Use of recently measured electron cross sections and many observational data from ground based and rocket studies shows that the results are consistent with spectra equivalent to a power law E to the minus 1.4 power for primaries and secondaries combined. The unified primary spectra of Rees (1969) and secondary spectra of Rees et al. (1969) fail seriously to predict the optical ratios. It is shown that Rees' primary spectrum is deficient in slow primaries, owing to the use of defective Monte Carlo results of Maeda (1965). Doubt is thereby cast on the validity of experimental results for the differential spectrum below 50 eV reported by Feldman et al. (1971) because of the rapid decrease in flux with energy shown by those measurements.

Shemansky, D. E.↗

Measured optical performance of three Fabry-Perot interferometers for use in a tunable ultraviolet filter

A narrowband ultraviolet (UV) filter would allow the first monochromatic two-dimensional images of astrophysical plasmas to be obtained in UV emission lines. The high etendue and spectral resolving power of the Fabry-Perot (FP) interferometer make it an excellent candidate for use in a tunable UV filter, provided that adequate optical performance can be obtained. Laboratory measurements of three UV FP interferometers with progressively greater dielectric mirror reflectances are described. The measurements demonstrate the adequate reflectivity, absorption, and small-scale smoothness of currently available coatings and substrates for UV interferometry. The measurements are conducted at 228.8 nm utilizing a cadmium hollow cathode light source. The best performing interferometer has a finesse of 41 and maximum transmittance of 0.38 over a coating-performance-dominated 3-mm-diam subaperture and a finesse of 26 and maximum transmittance of 0.32 over a parabolic-defect-dominated 30-mm-diam aperture. This interferometer is well suited for use in a UV filter system.

Korendyke, Clarence M.↗

Hydrogen Sensors Boost Hybrids; Today's Models Losing Gas?

Advanced chemical sensors are used in aeronautic and space applications to provide safety monitoring, emission monitoring, and fire detection. In order to fully do their jobs, these sensors must be able to operate in a range of environments. NASA has developed sensor technologies addressing these needs with the intent of improving safety, optimizing combustion efficiencies, and controlling emissions. On the ground, the chemical sensors were developed by NASA engineers to detect potential hydrogen leaks during Space Shuttle launch operations. The Space Shuttle uses a combination of hydrogen and oxygen as fuel for its main engines. Liquid hydrogen is pumped to the external tank from a storage tank located several hundred feet away. Any hydrogen leak could potentially result in a hydrogen fire, which is invisible to the naked eye. It is important to detect the presence of a hydrogen fire in order to prevent a major accident. In the air, the same hydrogen-leak dangers are present. Stress and temperature changes can cause tiny cracks or holes to form in the tubes that line the Space Shuttle s main engine nozzle. Such defects could allow the hydrogen that is pumped through the nozzle during firing to escape. Responding to the challenges associated with pinpointing hydrogen leaks, NASA endeavored to improve propellant leak-detection capabilities during assembly, pre-launch operations, and flight. The objective was to reduce the operational cost of assembling and maintaining hydrogen delivery systems with automated detection systems. In particular, efforts have been focused on developing an automated hydrogen leak-detection system using multiple, networked hydrogen sensors that are operable in harsh conditions.

Source record↗

UV filters for lighting of plants

The wavelength dependent interaction of biological systems with radiation is commonly described by appropriate action spectra. Particularly effective plant responses are obtained for ultraviolet (UV) radiation. Excess shortwave UV-B radiation will induce genetic defects and plant damage. Besides the ecological discussion of the deleterious effects of the excess UV radiation there is increasing interest in horticultural applications of this spectral region. Several metabolic pathways leading to valuable secondary plant products like colors, odors, taste, or resulting in mechanical strength and vitality are triggered by UV radiation. Thus, in ecologically as well as in economically oriented experiments the exact generation and knowledge of the spectral irradiance, particularly near the UV absorption edge, is essential. The ideal filter 'material' to control the UV absorption edge would be ozone itself. However, due to problems in controlling the toxic and chemically aggressive, instable gas, only rather 'small ozone filters' have been realized so far. In artificial plant lighting conventional solid filter materials such as glass sheets and plastic foils (celluloseacetate or cellulosetriacetate) which can be easily handled have been used to absorb the UV-C and the excess shortwave UV-B radiation of the lamp emissions. Different filter glasses are available which provide absorption properties suitable for gradual changes of the spectral UV-B illumination of artificial lighting. Using a distinct set of lamps and filter glasses an acceptable simulation of the UV-B part of natural global radiation can be achieved. The aging of these and other filter materials under the extreme UV radiation in the lamphouse of a solar simulator is presently unavoidable. This instability can be dealt with only by a precise spectral monitoring and by replacing the filters accordingly. For this reason attempts would be useful to develop real ozone filters which can replace glass filters. In any case chamber experiments require a careful selection of the filter material used and must be accompanied by a continuous UV-B monitoring.

Doehring, T.↗

Characterization of Magnetoacoustic Emission Related to Structural Properties of Ferromagnets

An extensive study of magnetoacoustic emission (MAE) properties has been performed over the past several years. As a result, the dependence of the spectral characteristics of MAE on certain microstructural variations and uniaxially applied stress in a particular type of low carbon steel are now well known. The embrittlement-causing concentration of certain atomic species, e. g., tin, sulphur, phosphorous etc., at the grain boundaries of this steel creates strong potential barriers resisting the motion of non-180 domain walls which is the source of MAE. (Since the only type of non-180 domain walls in this material are 90 domain walls, the term 90 domain wall will be used throughout this paper in place of non-180 domain wall.) An MAE burst produced during one-half cycle of a hysteresis loop at a low AC magnetic field frequency (e. g., 0.7 Hz) shows two sub-peaks; the leading peak is usually sharp and short-lived, while the trailing peak is usually smooth and long-lasting. It has been shown that the enhanced domain wall-defect interaction, due to the strengthened potential barriers, causes an increase in the asymmetry of the MAE signal by suppressing the leading sub-peak and amplifying the trailing sub-peak. This phenomena is due to the delayed motion of the 90 domain walls. The effect of a tensile stress applied parallel to the external AC magnetic field is to diminish the MAE. On the other hand, the amplitude of the MAE burst has been shown to be a non-monotonic function of the stress amplitude. Recently, our study has concentrated on obtaining quantitative values for parameters computed from the MAE spectra averaged over a sufficient number of cycles to achieve statistical stability. Nevertheless, certain fundamental elements of the MAE characteristics remain unexplained.

Namkung, M.↗

Expression of the Acyl-Coenzyme A: Cholesterol Acyltransferase GFP Fusion Protein in Sf21 Insect Cells

The enzyme acyl-coenzyme A:cholesterol acyltransferase (ACAT) is an important contributor to the pathological expression of plaque leading to artherosclerosis n a major health problem. Adequate knowledge of the structure of this protein will enable pharmaceutical companies to design drugs specific to the enzyme. ACAT is a membrane protein located in the endoplasmic reticulum.t The protein has never been purified to homogeneity.T.Y. Chang's laboratory at Dartmouth College provided a 4-kb cDNA clone (K1) coding for a structural gene of the protein. We have modified the gene sequence and inserted the cDNA into the BioGreen His Baculovirus transfer vector. This was successfully expressed in Sf2l insect cells as a GFP-labeled ACAT protein. The advantage to this ACAT-GFP fusion protein (abbreviated GCAT) is that one can easily monitor its expression as a function of GFP excitation at 395 nm and emission at 509 nm. Moreover, the fusion protein GCAT can be detected on Western blots with the use of commercially available GFP antibodies. Antibodies against ACAT are not readily available. The presence of the 6xHis tag in the transfer vector facilitates purification of the recombinant protein since 6xHis fusion proteins bind with high affinity to Ni-NTA agarose. Obtaining highly pure protein in large quantities is essential for subsequent crystallization. The purified GCAT fusion protein can readily be cleaved into distinct GFP and ACAT proteins in the presence of thrombin. Thrombin digests the 6xHis tag linking the two protein sequences. Preliminary experiments have indicated that both GCAT and ACAT are expressed as functional proteins. The ultimate aim is to obtain large quantities of the ACAT protein in pure and functional form appropriate for protein crystal growth. Determining protein structure is the key to the design and development of effective drugs. X-ray analysis requires large homogeneous crystals that are difficult to obtain in the gravity environment of earth. Protein crystals grown in microgravity are often larger and have fewer defects than those grown on earth. The analysis of higher quality space-grown crystals will assist in structure-based drug design. We have successfully grown GCAT-infected Sf21 cells in both adhesion and suspension cultures. Expression levels of GCAT in cell lines such as Sf9 and High Five appear to be reduced. We intend to replicate GCAT expression in all three cell lines using the NASA rotating wall bioreactor which effectively duplicates a microgravity environment. The bioreactor itself could be launched to study the expression of the GFP and GCAT proteins in the actual microgravity environment achieved in orbit.

Mahtani, H. K.↗

Theoretical and Experimental Evaluation of the Bond Strength Under Peeling Loads

Reliable applications of adhesively bonded joints require understanding of the stress distribution along the bond-line and the stresses that are responsible for the joint failure. To properly evaluate factors affecting peel strength, effects of defects such as voids on the stress distribution in the overlap region must be understood. In this work, the peel stress distribution in a single lap joint is derived using a strength of materials approach. The bonded joint is modeled as Euler-Bernoulli beams, bonded together with an adhesive. which is modeled as an elastic foundation which can resist both peel and shear stresses. It is found that for certain adhesive and adherend geometries and properties, a central void with the size up to 50 percent of the overlap length has negligible effect on the peak peel and shear stresses. To verify the solutions obtained from the model, the problem is solved again by using the finite element method and by treating the adherends and the adhesive as elastic materials. It is found that the model used in the analysis not only predicts the correct trend for the peel stress distribution but also gives rather surprisingly close results to that of the finite element analysis. It is also found that both shear and peel stresses can be responsible for the joint performance and when a void is introduced, both of these stresses can contribute to the joint failure as the void size increases. Acoustic emission (AE) activities of aluminum-adhesive-aluminum specimens with different void sizes were monitored. The AE ringdown counts and energy were very sensitive and decreased significantly with the void size. It was observed that the AE events were shifting towards the edge of the overlap where the maximum peeling and shearing stresses were occurring as the void size increased.

Nayeb-Hashemi, Hamid↗

Platform for Post-Processing Waveform-Based NDE

Signal- and image-processing methods are commonly needed to extract information from the waves, improve resolution of, and highlight defects in an image. Since some similarity exists for all waveform-based nondestructive evaluation (NDE) methods, it would seem that a common software platform containing multiple signal- and image-processing techniques to process the waveforms and images makes sense where multiple techniques, scientists, engineers, and organizations are involved. NDE Wave & Image Processor Version 2.0 software provides a single, integrated signal- and image-processing and analysis environment for total NDE data processing and analysis. It brings some of the most useful algorithms developed for NDE over the past 20 years into a commercial-grade product. The software can import signal/spectroscopic data, image data, and image series data. This software offers the user hundreds of basic and advanced signal- and image-processing capabilities including esoteric 1D and 2D wavelet-based de-noising, de-trending, and filtering. Batch processing is included for signal- and image-processing capability so that an optimized sequence of processing operations can be applied to entire folders of signals, spectra, and images. Additionally, an extensive interactive model-based curve-fitting facility has been included to allow fitting of spectroscopy data such as from Raman spectroscopy. An extensive joint-time frequency module is included for analysis of non-stationary or transient data such as that from acoustic emission, vibration, or earthquake data.

Roth, Don J.↗

Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport

The objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the crystals grown by vapor transport as results of buoyance-driven convection and growth interface fluctuations caused by irregular fluid-flows. ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, were grown by vapor transport technique with real time in-situ non-invasive monitoring techniques. The grown crystals were characterized extensively to correlate the grown crystal properties with the growth conditions. The following are the research progress in the past two years. In-situ monitoring of partial pressure by optical absorption technique and visual observation of the growing crystal were performed during vapor growth of ZnSe. Low-temperature photoluminescence (PL) spectra and glow discharge mass spectroscopy (GDMS) were measured on ZnSe starting materials provided by various vendors and on bulk crystals grown from these starting materials by physical vapor transport (PVT) to study the effects of purification and contamination during crystal growth process. Optical characterization was performed on wafers sliced from the grown crystals of ZnSe, ZnTe and ZnSe(1-x),Te(x), (0<x<0.4). Energy band gaps at room temperature were determined from optical transmission measurements and a best fit curve to the band gap vs. composition, x, data gives a bowing parameter of 1.45. Low-temperature photoluminescence (PL) spectra of ZnSe and ZnTe were dominated by near band edge emissions and no deep donor-acceptor pairs were observed. The PL spectrum exhibited a broad emission for the ZnSe(1-x),Te(x), samples, 0.09<x<0.39. The single broad PL emission spectra and the spectra measured as a function of temperature were interpreted as being associated with the exciton bound to Te clusters because of the high Te content in these samples. To validate numerical codes, in-situ monitoring during the PVT of HgI2 was designed. Optical absorption spectra of the vapor phase over HgI2 were measured for wavelengths between 200 and 600nm at sample temperatures between 349 and 610K. The Beer's Law constants for 15 wavelengths between 200 and 440 nm were determined. From these constants the vapor pressure of HgI2 was established as a function of temperature for the liquid and the solid Beta-phases To characterize the growth conditions during the PVT growth of In-doped ZnSe the optical absorbance of the vapor phase over the In-Se system were measured and were used to obtain the partial pressures of Se2(g) and In2Se(g).

Su, Ching-Hua↗

UAV Inspection of Electrical Transmission Infrastructure with Path Conformance Autonomy and Lidar-Based Geofences NASA Report on UTM Reference Mission Flights at Southern Company Flights November 2016

Flights at low altitudes in close proximity to electrical transmission infrastructure present serious navigational challenges: GPS and radio communication quality is variable and yet tight position control is needed to measure defects while avoiding collisions with ground structures. To advance unmanned aerial vehicle (UAV) navigation technology while accomplishing a task with economic and societal benefit, a high voltage electrical infrastructure inspection reference mission was designed. An integrated air-ground platform was developed for this mission and tested in two days of experimental flights to determine whether navigational augmentation was needed to successfully conduct a controlled inspection experiment. The airborne component of the platform was a multirotor UAV built from commercial off-the-shelf hardware and software, and the ground component was a commercial laptop running open source software. A compact ultraviolet sensor mounted on the UAV can locate 'hot spots' (potential failure points in the electric grid), so long as the UAV flight path adequately samples the airspace near the power grid structures. To improve navigation, the platform was supplemented with two navigation technologies: lidar-to-polyhedron preflight processing for obstacle demarcation and inspection distance planning, and trajectory management software to enforce inspection standoff distance. Both navigation technologies were essential to obtaining useful results from the hot spot sensor in this obstacle-rich, low-altitude airspace. Because the electrical grid extends into crowded airspaces, the UAV position was tracked with NASA unmanned aerial system traffic management (UTM) technology. The following results were obtained: (1) Inspection of high-voltage electrical transmission infrastructure to locate 'hot spots' of ultraviolet emission requires navigation methods that are not broadly available and are not needed at higher altitude flights above ground structures. (2) The sensing capability of a novel airborne UV detector was verified with a standard ground-based instrument. Flights with this sensor showed that UAV measurement operations and recording methods are viable. With improved sensor range, UAVs equipped with compact UV sensors could serve as the detection elements in a self-diagnosing power grid. (3) Simplification of rich lidar maps to polyhedral obstacle maps reduces data volume by orders of magnitude, so that computation with the resultant maps in real time is possible. This enables real-time obstacle avoidance autonomy. Stable navigation may be feasible in the GPS-deprived environment near transmission lines by a UAV that senses ground structures and compares them to these simplified maps. (4) A new, formally verified path conformance software system that runs onboard a UAV was demonstrated in flight for the first time. It successfully maneuvered the aircraft after a sudden lateral perturbation that models a gust of wind, and processed lidar-derived polyhedral obstacle maps in real time. (5) Tracking of the UAV in the national airspace using the NASA UTM technology was a key safety component of this reference mission, since the flights were conducted beneath the landing approach to a heavily used runway. Comparison to autopilot tracking showed that UTM tracking accurately records the UAV position throughout the flight path.

Moore, Andrew J.↗

Metastable Phase Relations in the System Ca(sub O)-Al2(sub O)3-MgO-TiO(sub 2): Applications to Ca- And Al-Rich Inclusions

Introduction: High temperature phases such as corundum, hibonite, grossite, and perovskite are among the earliest phases that condensed in the early solar nebula. Recent work has shown that defect-structured phases occur in some ultrarefractory inclusions as metastable, possibly more kinetically-favored alternatives to the thermodynamically predicted stable phase assemblages [1-4]. For example, Han et al. have shown that non-stoichiometry in hibonite is accommodated by extra "spinel" blocks in the structure instead of the equilibrium assemblages hibonite+corundum or hibonite+spinel. To explore these relations, we have conducted a series of experiments in the system CaO-Al2O3- MgO-TiO2. Here we discuss the compositions and mineralogy of the experimental samples and how they relate to phases in refractory inclusions with a focus on perovskite and spinel. Methods: For the series of annealing studies, a CaO-Al2O3 eutectic melt is allowed to react with a pure alumina crucible at 1,530degC for either 4 hours or 5 days, followed by quenching in air. Later experiments were similar except that additions of 5 wt% MgO, and CaTiO(sub 3) were used to explore the effect of minor elements on the phase assemblages. The experimental conditions resulted in reaction zones approximately 100-300 m wide consisting of a hibonite layer immediately adjacent to the corundum, followed by a grossite layer, and finally krotite with residual quenched melt. For the experiments with Mg, spinel is distributed in all layers but is mainly concentrated in the krotite layer. In the Ti-bearing experiments, perovskite precipitated in association with the krotite and residual melt. In addition to the experiments, we also analyzed perovskite grains in the FUN inclusion SHAL [5] and a large compact type A CAI from Allende. The experiments and refractory inclusions were analyzed using a JEOL 7600F SEM and quantitative analyses were obtained using the JEOL 8530F field-emission electron microprobe.

Keller, L. P.↗

Electron Beam Induced Luminescence of SiO2 Optical Coatings

Optical coatings of disordered thin film SiO,/SiO, samples undergoing electron beam bombardment exhibited a cathodoluminescence effect. Measurements were made of the absolute illuminance and emission spectra as functions of incident electron energy (0.2 keV to 30 keV). flux (approx. 0.1 nA/sq cm to > 100 nA/sq cm) and power (<50 nW/sq cm to > 3mW/sq cm) for coatings (approx.60 nm to approx.200 nm thick) on reflective metal substrates over a range of sample temperatures (approx.40 K to approx.400 K) and emission wavelengths (approx.260 nm to approx.5000 nm). Illuminance reached a plateau saturation intensity I(sub sat) approx. 10(exp -4)W/sq cm. scaling as [I(sub mc)/(I + I(sub mc)/I(sub sat)] as incident power I(sub mc) approached I(sub sat). Well below I(sub sat), illuminance scaled linearly with incident power for lower-energy non-penetrating radiation that deposited all of its energy in the dielectric film. At higher incident energies (> 1-5 keV) electrons penetrate the dielectric, depositing only a fraction of their energy in the dielectric film, where deposited energy scales as the ratio of film thickness to penetration range. Since electron range exhibits a peak below approx. 1 keV, the illuminance decreased with increasing energy for penetrating radiation. The temperature dependence of the illuminance. in general, increased with decreasing temperature. Changes in apparent color with temperature were also observed. Four bands in the UV/VIS/NIR range from 300 nm to 1000 nm were observed in spectral measurements; no significant luminescence was detected in a range from approx. 1000 nm to approx. 5000 nm. These different bands either increased or decreased in intensity and shifted slightly in energy with decreasing temperature. Our measurements are explained in terms of simple disordered band theory models based on atomic-scale stochastic transport of electrons in highly disordered insulating materials. The theoretical models provide a fundamental basis for understanding the dependence of cathodoluminescence on irradiation time, incident flux and energy. and sample thickness and temperature. The observed luminescence occurs when an incident high energy electron excites a valence band electron into the conduction band. Following the excitation. a complex series of transitions take place between the extended conduction states and the long-lived localized trapped states (or chromophores) associated with structural or compositional defects in the dielectric materials. Thc transport equations and models of thc spatial and energy distribution of the trapped states below the mobility edge, their occupancy, and transitions provide microscopic scale insights into this macroscopic phenomenon. Our observations and theoretical models are also compared with similar previous room temperature studies of similar SiO2 films.

Dennison, J. R.↗

Methods of Fabricating Scintillators with Radioisotopes for Beta Battery Applications

Technology has been developed for a class of self-contained, long-duration power sources called beta batteries, which harvest the energy contained in the radioactive emissions from beta decay isotopes. The new battery is a significant improvement over the conventional phosphor/solar cell concept for converting this energy in three ways. First, the thin phosphor is replaced with a thick scintillator that is transparent to its own emissions. By using a scintillator sufficiently thick to completely stop all the beta particles, efficiency is greatly improved. Second, since the energy of the beta particles is absorbed in the scintillator, the semiconductor photodetector is shielded from radiation damage that presently limits the performance and lifetime of traditional phosphor converters. Finally, instead of a thin film of beta-emitting material, the isotopes are incorporated into the entire volume of the thick scintillator crystal allowing more activity to be included in the converter without self-absorption. There is no chemical difference between radioactive and stable strontium beta emitters such as Sr-90, so the beta emitter can be uniformly distributed throughout a strontium based scintillator crystal. When beta emitter material is applied as a foil or thin film to the surface of a solar cell or even to the surface of a scintillator, much of the radiation escapes due to the geometry, and some is absorbed within the layer itself, leading to inefficient harvesting of the energy. In contrast, if the emitting atoms are incorporated within the scintillator, the geometry allows for the capture and efficient conversion of the energy of particles emitted in any direction. Any gamma rays associated with secondary decays or Bremsstrahlung photons may also be absorbed within the scintillator, and converted to lower energy photons, which will in turn be captured by the photocell or photodiode. Some energy will be lost in this two-stage conversion process (high-energy particle to low-energy photons to electric current). The geometric advantage partially offsets this as well, since the absorption depth of high-energy beta radiation is much larger than the depth of a p-n junction. Thus, in a p-n junction device, much of the radiation is absorbed far away from the junction, and the electron- hole pairs are not all effectively collected. In contrast, with a transparent scintillator the radiation can be converted to light in a larger volume, and all of the light can be collected in the active region of the photodiode. Finally, the new device is more practical because it can be used at much higher power levels without unduly shortening its lifetime. While the crystal structure of scintillators is also subject to radiation damage, their performance is far more tolerant of defects than that of semiconductor junctions. This allows the scintillator- based approach to use both higher energy isotopes and larger quantities of the isotopes. It is projected that this technology has the potential to produce a radioisotope battery with up to twice the efficiency of presently used systems.

Rensing, Noa M.↗

Five-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Data Processing, Sky Maps, and Basic Results

The Wilkinson Microwave Anisotropy Probe (WMAP) is a Medium-Class Explorer (MIDEX) satellite aimed at elucidating cosmology through full-sky observations of the cosmic microwave background (CMB). The WMAP full-sky maps of the temperature and polarization anisotropy in five frequency bands provide our most accurate view to date of conditions in the early universe. The multi-frequency data facilitate the separation of the CMB signal from foreground emission arising both from our Galaxy and from extragalactic sources. The CMB angular power spectrum derived from these maps exhibits a highly coherent acoustic peak structure which makes it possible to extract a wealth of information about the composition and history of the universe. as well as the processes that seeded the fluctuations. WMAP data have played a key role in establishing ACDM as the new standard model of cosmology (Bennett et al. 2003: Spergel et al. 2003; Hinshaw et al. 2007: Spergel et al. 2007): a flat universe dominated by dark energy, supplemented by dark matter and atoms with density fluctuations seeded by a Gaussian, adiabatic, nearly scale invariant process. The basic properties of this universe are determined by five numbers: the density of matter, the density of atoms. the age of the universe (or equivalently, the Hubble constant today), the amplitude of the initial fluctuations, and their scale dependence. By accurately measuring the first few peaks in the angular power spectrum, WMAP data have enabled the following accomplishments: Showing the dark matter must be non-baryonic and interact only weakly with atoms and radiation. The WMAP measurement of the dark matter density puts important constraints on supersymmetric dark matter models and on the properties of other dark matter candidates. With five years of data and a better determination of our beam response, this measurement has been significantly improved. Precise determination of the density of atoms in the universe. The agreement between the atomic density derived from WMAP and the density inferred from the deuterium abundance is an important test of the standard big bang model. Determination of the acoustic scale at redshift z = 1090. Similarly, the recent measurement of baryon acoustic oscillations (BAO) in the galaxy power spectrum (Eisenstein et al. 2005) has determined the acoustic scale at redshift z approx. 0.35. When combined, these standard rulers accurately measure the geometry of the universe and the properties of the dark energy. These data require a nearly flat universe dominated by dark energy consistent with a cosmological constant. Precise determination of the Hubble Constant, in conjunction with BAO observations. Even when allowing curvature (Omega(sub 0) does not equal 1) and a free dark energy equation of state (w does not equal -1), the acoustic data determine the Hubble constant to within 3%. The measured value is in excellent agreement with independent results from the Hubble Key Project (Freedman et al. 2001), providing yet another important consistency test for the standard model. Significant constraint of the basic properties of the primordial fluctuations. The anti-correlation seen in the temperature/polarization (TE) correlation spectrum on 4deg scales implies that the fluctuations are primarily adiabatic and rule out defect models and isocurvature models as the primary source of fluctuations (Peiris et al. 2003).

Weiland, J.L.↗