Search NASA⌕ Search

SEARCH · Search NASA

Results for “delta method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Improvement of the thermoelectric properties of [Bi{sub 1.68}Ca{sub 2}O{sub 4-{delta}}]{sup RS}[CoO{sub 2}]{sub 1.69} cobaltite by chimie douce methods

[Bi{sub 1.68}Ca{sub 2}O{sub 4-{delta}}]{sup RS}[CoO{sub 2}]{sub 1.69} has been obtained by different chimie douce methods and uniaxially or isostatically pressed. The influence of these parameters on the thermoelectric properties has been investigated. Contrary to the Seebeck coefficient, which remains unchanged, the electrical conductivity is greatly modified. In particular, spray-drying synthesis followed by uniaxial pressing results in an electrical conductivity two times larger than in the case of conventional solid state synthesis. Our results suggest that a narrow particle size distribution is beneficial to the thermoelectric properties of the layered compounds. The spray-drying technique seems to be promising to improve the electrical conductivity of layered materials. Moreover, this method presents other advantages (homogeneous samples and less energetic processing) which could be interesting to the future manufacturing of thermoelectric devices. - Graphical abstract: Small particles and narrow size distribution is obtained for spray-drying [Bi{sub 1.68}Ca{sub 2}O{sub 4}]{sup RS}[CoO{sub 2}]{sub 1.69} cobaltate. The power factor is boosted up two times compared with the conventional solid state method.

36 MATERIALS SCIENCE↗

Implementation of Weighted Delta-Tracking with Scattering in the Serpent 2 Monte Carlo Code

Serpent 2, a continuous-energy Monte Carlo Reactor physics burnup code developed at the VTT Technical Research Centre of Finland, uses a common rejection sampling technique, known as Woodcock delta-tracking. This method improves the efficiency of Monte Carlo in the complicated geometric layout of nuclear reactors and is widely used despite drawbacks that make it inefficient in specific cases, such as in the presence of strong absorbers. At present, Serpent actively uses delta-tracking, falling back to a surface tracking option in situations where delta-tracking is inefficient to partially offset these weaknesses. Morgan and Kotlyar introduced a Weighted Delta Tracking (WDT) routine to address these issues, replacing the rejection sampling of absorption events with an implicit event. In this research, we examine the theoretical basis for rejection sampling and implicit events, and how they relate to WDT. We then discuss implementation of a routine that extends the WDT routine to include scattering events. The routine is implemented and tested within Serpent. We examine various test cases including a Boiling Water Reactor (BWR) pin cell, and homogenous fuel media based on the content of the fuel of the Transient Test Reactor (TREAT) at Idaho National Lab (INL)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Remote Sensing Monitoring Methods for Detecting Invasive Weed Coverage in Delta Waterways and Bay Marshlands

This presentation is part of the Independent Science Board of the State of California Delta Stewardship Council brown bag seminar series on the "How the Delta is Monitored", followed with a panel discussion. Various remote sensing approaches for aquatic vegetation will be reviewed. Key research and application issues with remote sensing monitoring in the Delta will be addressed.

Invasive↗

Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

Costen, Robert C.↗

Maximum likelihood method to correct for missed levels based on the {Delta}{sub 3}(L) statistic

The {Delta}{sub 3}(L) statistic of random matrix theory is defined as the average of a set of random numbers {l_brace}{delta}{r_brace}, derived from a spectrum. The distribution p({delta}) of these random numbers is used as the basis of a maximum likelihood method to gauge the fraction x of levels missed in an experimental spectrum. The method is tested on an ensemble of depleted spectra from the Gaussian orthogonal ensemble (GOE) and accurately returned the correct fraction of missed levels. Neutron resonance data and acoustic spectra of an aluminum block were analyzed. All results were compared with an analysis based on an established expression for {Delta}{sub 3}(L) for a depleted GOE spectrum. The effects of intruder levels are examined and seen to be very similar to those of missed levels. Shell model spectra were seen to give the same p({delta}) as the GOE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The delta-Eddington approximation for radiative flux transfer

Simple approximations, like the Eddington, are often incapable of coping with the highly asymmetric phase functions typical of particulate scattering. A simple yet accurate method called the delta-Eddington approximation is proposed for determining monochromatic radiative fluxes in an absorbing-scattering atmosphere. In this method, the governing phase function is approximated by a Dirac delta function forward scatter peak and a two-term expansion of the phase function. The fraction of scattering into the truncated forward peak is taken proportional to the square of the phase function asymmetry factor, which distinguishes the delta-Eddington approximation from others of similar nature. The transmission, reflection, and absorption predicted by the delta-Eddington approximation are compared with doubling method calculations for realistic ranges of optical depth, single-scattering albedo, surface albedo, sun angle and asymmetry factor. The approximation is shown to provide an accurate and analytically simple parameterization of radiation to replace the empirism currently encountered in many general circulation and climate models.

Joseph, J. H.↗

Spectral contaminant identifier for off-axis integrated cavity output spectroscopy measurements of liquid water isotopes

Developments in cavity-enhanced absorption spectrometry have made it possible to measure water isotopes using faster, more cost-effective field-deployable instrumentation. Several groups have attempted to extend this technology to measure water extracted from plants and found that other extracted organics absorb light at frequencies similar to that absorbed by the water isotopomers, leading to {delta}{sup 2}H and {delta}{sup 18}O measurement errors ({Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O). In this note, the off-axis integrated cavity output spectroscopy (ICOS) spectra of stable isotopes in liquid water is analyzed to determine the presence of interfering absorbers that lead to erroneous isotope measurements. The baseline offset of the spectra is used to calculate a broadband spectral metric, m{sub BB}, and the mean subtracted fit residuals in two regions of interest are used to determine a narrowband metric, m{sub NB}. These metrics are used to correct for {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O. The method was tested on 14 instruments and {Delta}{delta}{sup 18}O was found to scale linearly with contaminant concentration for both narrowband (e.g., methanol) and broadband (e.g., ethanol) absorbers, while {Delta}{delta}{sup 2}H scaled linearly with narrowband and as a polynomial with broadband absorbers. Additionally, the isotope errors scaled logarithmically with m{sub NB}. Using the isotope error versus m{sub NB} and m{sub BB} curves, {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O resulting from methanol contamination were corrected to a maximum mean absolute error of 0.93 per mille and 0.25 per mille respectively, while {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O from ethanol contamination were corrected to a maximum mean absolute error of 1.22 per mille and 0.22 per mille . Large variation between instruments indicates that the sensitivities must be calibrated for each individual isotope analyzer. These results suggest that the properly calibrated interference metrics can be used to correct for polluted samples and extend off-axis ICOS measurements of liquid water to include plant waters, soil extracts, wastewater, and alcoholic beverages. The general technique may also be extended to other laser-based analyzers including methane and carbon dioxide isotope sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Cross Section Measurements for the {sup 6}Li(n,t){alpha} Reaction in the Few MeV Region

New measured differential cross sections of tritons and alpha particles following the {sup 6}Li(n,t){alpha} reaction are reported for incident neutron energies between 0.2 and approximately 20 MeV. The neutrons were produced by spallation at the WNR facility at the Los Alamos Neutron Science CEnter (LANSCE), with the incident neutron energy determined by the time-of-flight method. Four E-{delta}E telescopes were used at eight laboratory angles. These data have been incorporated into a prior R-matrix fit for the compound {sup 7}Li system, and result in an (n,t) reaction cross section that is 4% to 10% higher than previous evaluations in the 1-3 MeV incident neutron energy region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Heat Shock Protein 27-Targeted Heptapeptide of the PKC{Delta} Catalytic V5 Region Sensitizes Tumors With Radio- and Chemoresistance

Purpose: Previous data suggest that the PKC{delta} catalytic V5 (PKC{delta}-V5) heptapeptide (HEPT) (FEQFLDI) binds HSP27 and blocks HSP27-mediated radio- or chemoresistance. Here we investigated further the in vivo function of the PKC{delta}-V5 HEPT. Methods and Materials: Labeling of HEPT with Cy5.5 or fluorescein isothiocyanate was performed to evaluate in vitro or in vivo distribution of HEPT. A clonogenic survival assay, flow cytometry, and Western blotting of cleaved caspase-3 were performed to determine in vitro sensitization effects of HEPT plus ionizing radiation (IR) versus IR alone or those of HEPT plus cisplatin(Cis) versus Cis alone. A nude mouse xenografting system was also applied to detect in vivo sensitizing effects of HEPT. Results: HEPT efficiently bound to HSP27 and showed sensitization after combined treatment with IR versus treatment with Cis alone in NCI-H1299 lung carcinoma cells, with higher HSP27 expression, which was similar to that of combined treatment with IR or with Cis alone in NCI-H460 lung carcinoma cells with lower HSP27 expression. In vivo image analysis using Cy5.5-labeled HEPT showed that HEPT was retained in HSP27-overexpressing cancer cells after xenografting to nude mice. Combined treatment of HEPT with IR versus that with Cis alone in xenografted mice showed that HEPT increased radio- or chemosensitization in NCI-H1299 cells compared to that in mice xenografted with NCI-H460 cells. Conclusions: The novel PKC{delta}-V5 HEPT may help overcome HSP27-mediated radio- or chemoresistance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal least-squares finite element method for elliptic problems

An optimal least squares finite element method is proposed for two dimensional and three dimensional elliptic problems and its advantages are discussed over the mixed Galerkin method and the usual least squares finite element method. In the usual least squares finite element method, the second order equation (-Delta x (Delta u) + u = f) is recast as a first order system (-Delta x p + u = f, Delta u - p = 0). The error analysis and numerical experiment show that, in this usual least squares finite element method, the rate of convergence for flux p is one order lower than optimal. In order to get an optimal least squares method, the irrotationality Delta x p = 0 should be included in the first order system.

Jiang, Bo-Nan↗

Kinetic-energy release of fragments from electron-impact dissociation of the molecular hydrogen ion and its isotopologues

We calculate here the kinetic-energy release distributions of fragments produced for electron-impact dissociation of the vibrationally excited molecular hydrogen ion ${{\mathrm{H}}_{2}}^{+}$ and its isotopologues ${{\mathrm{D}}_{2}}^{+}$ and ${{\mathrm{T}}_{2}}^{+}$. Here we apply the adiabatic-nuclei convergent close-coupling method and compare results with several different methods, including the ${\delta}$ approximation. Results are presented for a number of dissociative excitation transitions and dissociative ionization as a function of the initial vibrational state of the molecule. We confirm that the square root approximation is a good approximation for the adiabatic-nuclei kinetic-energy release cross sections of ${{\mathrm{H}}_{2}}^{+}$. Agreement with experiment, where available, is good.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-C-213-02: Characterizing 3D Printing in the Fabrication of Variable Density Phantoms

Purpose: In this work, we present characterization, process flow, quality control and application of 3D fabricated low density phantoms for radiotherapy quality assurance. Methods: A Rostock delta 3D printer using polystyrene filament of diameter 1.75 mm was used to print geometric volumes of 2×2×1 cm{sup 3} of varying densities. The variable densities of 0.1 to 0.75 g/cm {sup 3} were created by modulating the infill. A computed tomography (CT) scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. The time required to print these volumes was also recorded. Using the calibration, two low density cones (0.19, 0.52 g/cm{sup 3}) were printed and benchmarked against commercially available phantoms. The dosimetric validation of the low density scaling of Anisotropic Analytical Algorithm (AAA) was performed by using a 0.5 g/cm{sup 3} slab of 10×10×2.4 cm{sup 3} with EBT3 GafChromic film. The gamma analysis at 3%/3mm criteria were compared for the measured and computed dose planes. Results: Analysis of the volume of air pockets in the infill resulted in a reasonable uniformity for densities 0.4 to 0.75 g/cm{sup 3}. Printed phantoms with densities below 0.4 g/cm{sup 3} exhibited a higher ratio of air to polystyrene resulting in large non-uniformity. Compared to the commercial inserts, good agreement was observed only for the printed 0.52 g/cm{sup 3} cone. Dosimetric comparison for a printed low density volume placed in-between layers of solid water resulted in >95% gamma agreement between AAA calculated dose planes and measured EBT3 films for a 6MV 5×5 cm{sup 2} clinical beam. The comparison showed disagreement in the penumbra region. Conclusion: In conclusion, 3D printing technology opens the door to desktop fabrication of variable density phantoms at economical prices in an efficient manner for the quality assurance needs of a small clinic.

60 APPLIED LIFE SCIENCES↗

Magnetospheric field morphology at magnetically quiet times

Review of the magnetospheric morphology, using the method of the Delta B topology, where Delta B is the difference between the observed and a reference field. It is confirmed that Delta B continuously decreases inward to close distances from the earth at all local times. Extrapolating the statistical relation between Dst at the ground and the equatorial Delta B obtained from OGO-5 near perigee, it is shown that Dst is 54 gammas, when Delta B is zero at approximately 2 to 3 earth radii. Conversely, for a magnetically quiet condition as defined by Dst = 0, the average equatorial Delta B at these distances is -45 gammas. These results demonstrate the significance of the effects of the magnetospheric equatorial current that exists even at quiet times. A preliminary study of inclination shows that the field lines on the dusk side are more stretched out than on the dawn side. A comparison of declination on both sides indicates that the bending of the field lines toward the tail is greater near dusk than near dawn. These results suggest an appreciable dawn-dusk asymmetry in the configuration of the inner magnetospheric field.

Sugiura, M.↗

Indirect methods for measuring variations of the solar constant

The difference between the methods that measure delta S, and those that measure variations in the solar luminosity, delta L, is discussed. It is shown that the past practice of simply relating delta S to delta L by geometrical arguments is not valid because of anisotropy of the solar radiation. It is concluded that direct techniques prove the existence of short term variability that is fully explainable in terms of the passage of active regions (spots and faculae) on the face of the Sun. The obervations of changes in the solar diameter support the existence of structurally induced variations of the solar luminosity on timescales of tens of years, which are significant in the understanding of climatic variations.

Sofia, S.↗

Comparison of storm-time changes of geomagnetic field at ground and at MAGSAT altitudes

Computations concerning variations of the geomagnetic field at MAGSAT altitudes were investigated. Using MAGSAT data for the X, Y, and Z components of the geomagnetic field, a computer conversion to yield the H component was performed. Two methods of determining delta H normalized to a constant geocentric distance R sub 0 = 6800 were investigated, and the utility of elta H at times of magnetic storms was considered. Delta H at a geographical latitude of 0 at dawn and dusk, the standard Dst, and K sub p histograms were plotted and compared. Magnetic anomalies are considered. Examination of data from the majority of the 400 passes of MAGSAT considered show a reasonable delta H versus latitude variation. Discrepancies in values are discussed.

Kane, R. P.↗