Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A Coil Detection System for Dynamic Wireless Charging of Electric Vehicle

Application of wireless power transfer while EV is in motion can significantly reduce the battery storage capacity. A major challenge in implementation of dynamic wireless power transfer (DWPT) is automatic detection of EV to avoid loss in efficiency and alleviate any safety concerns. This paper proposes a novel coil detection method for segmented DWPT. Detection of the EV ahead of its arrival will initiate energizing of the transmitter buried inside the road to enable just-in-time transfer of power. At low speeds, communication can be a reliable method to power up the transmitter coil. However, at high speeds on highways, communication latency time for the detection of an EV is long and hence impractical. This paper proposes a low cost and low power EV detection system based on a novel orthogonal coil arrangement to detect EVs traveling at high speeds. Here, the proposed detection system was tested on a laboratory scale prototype for verification purpose. For high speed verification, simulation in PLECS was conducted to test the functionality of the proposed system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Energy Intrusion Detection System

SAND2022-14659 O The Wind Energy Intrusion Detection System uses a human-machine interface (HMI) to parse results and analyze for anomalies. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Johnson, Jay↗

Virus detection system

Nonpathogenic marker virus, monitored by compact automatic detection system, is used to determine ability of water-reclamation system to reject passage of viruses into potable water.

Fraser, A. S.↗

A bubble detection system for propellant filling pipeline

This paper proposes a bubble detection system based on the ultrasound transmission method, mainly for probing high-speed bubbles in the satellite propellant filling pipeline. First, three common ultrasonic detection methods are compared and the ultrasound transmission method is used in this paper. Then, the ultrasound beam in a vertical pipe is investigated, suggesting that the width of the beam used for detection is usually smaller than the internal diameter of the pipe, which means that when bubbles move close to the pipe wall, they may escape from being detected. A special device is designed to solve this problem. It can generate the spiral flow to force all the bubbles to ascend along the central line of the pipe. In the end, experiments are implemented to evaluate the performance of this system. Bubbles of five different sizes are generated and detected. Experiment results show that the sizes and quantity of bubbles can be estimated by this system. Also, the bubbles of different radii can be distinguished from each other. The numerical relationship between the ultrasound attenuation and the bubble radius is acquired and it can be utilized for estimating the unknown bubble size and measuring the total bubble volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VETA-1 x ray detection system

The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.

Podgorski, W. A.↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗

Evaluation of a dual processor implementation for a fault inferring nonlinear detection system

The design of a modified fault inferring nonlinear detection system (FINDS) algorithm for a dual-processor configured flight computer is described. The algorithm was changed in order to divide it into its translational dynamics and rotational kinematics and to use it for parallel execution on the flight computer. The FINDS consists of: (1) a no-fail filter (NFF), (2) a set of test-of-mean detection tests, (3) a bank of first order filters to estimate failure levels in individual sensors, and (4) a decision function. NFF filter performance using flight recorded sensor data is analyzed using a filter autoinitialization routine. The failure detection and isolation capability of the partitioned algorithm is evaluated. A multirate implementation for the bias-free and bias filter gain and covariance matrices is discussed.

Godiwala, P. M.↗

Development of an Intelligent Hypertext Manual for the Space Shuttle Hazardous Gas Detection System

The Intelligent Hypertext Manual (IHM) for the Hazardous Gas Detection System (HGDS) of the Space Shuttle is described as an example of an integrated knowledge system. The IHM is described in terms of its design as a system for facilitating the interpretation of real-time data regarding hazardous gases and their successful and timely detection. Hypermedia technology is employed that incorporates text, video, and sound, and the architecture of the IHM integrated knowledge system is based on knowledge elements, a basic user interface, and integrated application software. Knowledge organization enhances the retrieval of documents for launch commit criteria, operations and maintenance requirements, flight-measurement location, and hypermedia incorporation. The integration of computer and AI technologies for the HGDS IHM demonstrates the potential for enhancing efficiency in aerospace operations with aerospace data that are easy to retrieve.

Lo, Ching F.↗

Detection system ensures positive alarm activation in digital message loss

Lost Word Detection System /LOWDS/ provides special identification for each error detection message transmitted from receiver to transmitter. The message is identified as an original message or an n-times retransmitted message so the receiver can detect where a retransmission request was not fulfilled and activate an alarm.

Bokros, P.↗

A practical obstacle detection system for the Mars Rover

Discussion of an obstacle detection system which uses a laser range finder as the principal sensing device. The laser scans the scene ahead and stores the range data for the terrain in a matrix form. This matrix can be thought of as a 'range image'. This range varies from point to point, but sharp changes are caused by the presence of obstacles. Some existing algorithms and one developed by the authors were used to obtain the outlines of obstacles from the 'range image'. All these algorithms end with a thresholding operation. A theoretical analysis shows how a proper value of the threshold may be chosen, given the type of irregularity of the terrain to be detected. The analysis also shows how large the statistics of measurement noise can be allowed without leading to false alarms.

Reed, M.↗

A solenoid failure detection system for cold gas attitude control jet valves

The development of a solenoid valve failure detection system is described. The technique requires the addition of a radioactive gas to the propellant of a cold gas jet attitude control system. Solenoid failure is detected with an avalanche radiation detector located in the jet nozzle which senses the radiation emitted by the leaking radioactive gas. Measurements of carbon monoxide leakage rates through a Mariner type solenoid valve are presented as a function of gas activity and detector configuration. A cylindrical avalanche detector with a factor of 40 improvement in leak sensitivity is proposed for flight systems because it allows the quantity of radioactive gas that must be added to the propellant to be reduced to a practical level.

Johnston, P. A.↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of Advanced Atmospheric Water Vapor Differential Absorption Lidar (DIAL) Detection System

The measurement of atmospheric water vapor is very important for understanding the Earth's climate and water cycle. The lidar atmospheric sensing experiment (LASE) is an instrument designed and operated by the Langley Research Center for high precision water vapor measurements. The design details of a new water vapor lidar detection system that improves the measurement sensitivity of the LASE instrument by a factor of 10 are discussed. The new system consists of an advanced, very low noise, avalanche photodiode (APD) and a state-of-the-art signal processing circuit. The new low-power system is also compact and lightweight so that it would be suitable for space flight and unpiloted atmospheric vehicles (UAV) applications. The whole system is contained on one small printed circuit board (9 x 15 sq cm). The detection system is mounted at the focal plane of a lidar receiver telescope, and the digital output is read by a personal computer with a digital data acquisition card.

Refaat, Tamer F.↗

Performance and long-term stability of the ICARUS-T600 scintillation light detection system

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \sim 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. Long-term behavior of PMT gains and timing resolution, demonstrate the robustness and reliability of the ICARUS scintillation light detection system and provide valuable input for the design and operation of future large-scale liquid argon detectors.

Raselli, Gian Luca [INFN, Perugia] (ORCID:00000002↗