At least 127 records · Page 7

Distortions and stabilization of simple-cubic calcium at high pressure and low temperature

Ca-III, the first superconducting calcium phase under pressure, was identified as simple-cubic (sc) by previous X-ray diffraction (XRD) experiments. In contrast, all previous theoretical calculations showed that sc had a higher enthalpy than many proposed structures and had an imaginary (unstable) phonon branch. By using our newly developed submicrometer high-pressure single-crystal XRD, cryogenic high-pressure XRD, and theoretical calculations, we demonstrate that Ca-III is neither exactly sc nor any of the lower-enthalpy phases, but sustains the sc-like, primitive unit by a rhombohedral distortion at 300 K and a monoclinic distortion below 30 K. This surprising discovery reveals a scenario that the high-pressure structure of calcium does not go to the zero-temperature global enthalpy minimum but is dictated by high-temperature anharmonicity and low-temperature metastability fine-tuned with phonon stability at the local minimum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis and Properties of the Helium Clathrate and Defect Perovskite [He 2– x $^\square$ x ][CaNb]F 6

The defect double perovskite [He 2– x $^\square$ x ][CaNb]F 6 , with helium on its A-site, can be prepared by the insertion of helium into ReO 3 -type CaNbF 6 at high pressure. Upon cooling from 300 to 100 K under 0.4 GPa helium, ~60% of the A-sites become occupied. Helium uptake was quantified by both neutron powder diffraction and gas insertion and release measurements. After the conversion of gauge pressure to fugacity, the uptake of helium by CaNbF 6 can be described by a Langmuir isotherm. The enthalpy of absorption for helium in [He 2– x $^\square$ x ][CaNb]F 6 is estimated to be ~+3(1) kJ mol –1 , implying that its formation is entropically favored. Helium is able to diffuse through the material on a time scale of minutes at temperatures down to ~150 K but is trapped at 100 K and below. The insertion of helium into CaNbF 6 reduces the magnitude of its negative thermal expansion, increases the bulk modulus, and modifies its phase behavior. On compressing pristine CaNbF 6 , at 50 and 100 K, a cubic (Fm$\overline{3}$m) to rhombohedral (R$\overline{3}$) phase transition was observed at <0.20 GPa. However, a helium-containing sample remained cubic at 0.4 GPa and 50 K. CaNbF 6 , compressed in helium at room temperature, remained cubic to >3.7 GPa, the limit of our X-ray diffraction measurements, in contrast to prior reports that upon compression in a nonpenetrating medium, a phase transition is detected at ~0.4 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscopium: a Scanning Hard X-ray Nanoprobe Beamline at Synchrotron Soleil

Nanoscopium is the single scanning hard X-ray nano-probe beamline planned at SOLEIL. This {approx}155 m long beamline will fully exploit the high brilliance and coherence characteristics of the X-ray beam both for diffraction limited focusing and for contrast formation. It will offer the most advanced imaging techniques in multimodal mode and will be a research tool for a wide user community working in the fields of earth-, environmental-, and life-sciences. The different {mu}-{mu}nano-probe techniques offered by the beamline will permit elemental mapping at trace (ppm) levels (scanning XRF), speciation mapping (XANES), phase gradient mapping (scanning differential phase contrast), and density-contrast based imaging of internal structures (coherent diffraction imaging) in the 30 nm to 1 {mu}m spatial resolution range, also in ''in situ conditions''. Nanoscopium will cover the 5-20 keV energy range. The stability of the nanobeam will be ensured by horizontally reflecting beamline optics (a sagitally and a tangentially pre-focusing mirror, horizontally reflecting monochromators) in front of the overfilled secondary source. Trade-off between high energy resolution ({Delta}E/E{approx}10{sup -4}) and high flux (10{sup 11} ph/s with {Delta}E/E{approx}10{sup -2}) will be achieved by two interchangeable monochromators (a double crystal and a double multilayer one). KB mirror and FZP lenses will be used as focusing devices. The beamline is in the design and construction phase. It is foreseen to be open for users at the beginning of 2013.

43 PARTICLE ACCELERATORS↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Influence of substrate temperature on glancing angle deposited Ag nanorods

When Ag sculptured thin films were grown with glancing angle deposition by ion beam sputtering at either room temperature or elevated substrate temperatures T{sub S}, a large morphological difference was observed. The incident particle flux reached the silicon substrate at a glancing angle {beta}{>=}80 deg. as measured to the substrate normal. A slit aperture was used in order to reduce the particle beam divergence. At room temperature, columnar structures were formed, irrespective of the presence of the slit aperture. At elevated temperatures (573 and 623 K) and collimated particle flux in the presence of the slit aperture, however, enhanced surface diffusion causes the growth of crystalline nanorod- and nanowirelike structures. In the absence of the slit aperture, the flux beam divergence is higher, resulting in island- and mountainlike crystalline structures. The density of the nanorods and nanowires was observed to be higher on the planar Si substrates in comparison to honeycomblike prepatterned substrates with different pattern periods. On the patterned substrates, the nanorods are not necessarily found to be evolving on the seed points but can rather be also observed in-between the artificial seeds. The glancing angle deposited films at high temperatures were observed to be polycrystalline, where the (111) crystal orientation of the film is dominant, while the presence of the less intense (200) reflection was noticed from the x-ray diffraction measurements. In contrast, compact thin films deposited with {beta}{approx_equal}0 deg. at high temperatures were found to be epitaxial with (200) orientation.

36 MATERIALS SCIENCE↗

High-temperature stability of thermoelectric Ca{sub 3}Co{sub 4}O{sub 9} thin films

An enhanced thermal stability in thermoelectric Ca{sub 3}Co{sub 4}O{sub 9} thin films up to 550 °C in an oxygen rich environment was demonstrated by high-temperature electrical and X-ray diffraction measurements. In contrast to generally performed heating in helium gas, it is shown that an oxygen/helium mixture provides sufficient thermal contact, while preventing the previously disregarded formation of oxygen vacancies. Combining thermal cycling with electrical measurements proves to be a powerful tool to study the real intrinsic thermoelectric behaviour of oxide thin films at elevated temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interpretable and Efficient Interferometric Contrast in Scanning Transmission Electron Microscopy with a Diffraction-Grating Beam Splitter

Efficient imaging of biomolecules, 2D materials and electromagnetic fields depends on retrieval of the phase of transmitted electrons. We demonstrate a method to measure phase in a scanning transmission electron microscope using a nanofabricated diffraction grating to produce multiple probe beams. The measured phase is more interpretable than phase-contrast scanning transmission electron microscopy techniques without an off-axis reference wave, and the resolution could surpass that of off-axis electron holography. Here, we apply the technique to image nanoparticles, carbon sub- strates and electric fields. The contrast observed in experiments agrees well with contrast predicted in simulations.

36 MATERIALS SCIENCE↗

Diffraction Modeling of Finite Subband EFC Probing on Dark Hole Contrast with WFIRST-CGI Shaped Pupil Coronagraph

The current NASA WFIRST (Wide-Field InfraRed Survey Telescope) coronagraph instrument (CGI) design allocates two subband filters per each full science band in order to contain system complexity and cost. We present our detailed investigation results on the adequacy of such a limited number of finite subband filters in achieving broadband dark hole contrast with a shaped pupil coronagraph (SPC). The study is based on diffraction propagation modeling with realistic WFIRST optics, where each subband’s image plane electric field is estimated from pairwise pupil plane deformable mirror (DM) probing and image plane intensity averaging of the resulting fields of multiple (subband) wavelengths. Multiple subband choices and probing and control strategies are explored, including standard subband probing; mixed wavelength and/or weighted Jacobian matrix; subband probing with intensity subtraction; and extended subband probing with intensity subtraction. Overall, the investigation shows that the achievable contrast with a limited number of finite subbands is about 2~2.5x worse than the designed contrast for the current SPC. The result suggests that future shaped pupil designs should be optimized for slightly broader bandwidths than the intended science bandpasses if limited subbands are used for wavefront sensing via probing.

WFIRST↗

Multimodal microscopy of extended defects in β-Ga 2 O 3 (010) EFG crystals

Beta-phase gallium oxide (β-Ga 2 O 3 ) has attracted attention in recent years as a potentially low cost, large area substrate and active layer material for high power, high temperature power electronics and sensing devices. However, growth of β-Ga 2 O 3 crystals is complicated by easily activated (100) and (001) cleavage planes, the presence of low angle grain boundaries (LAGBs) and twins, and the potential formation of polycrystalline grains. In this study, β-Ga 2 O 3 crystals were grown by the edge-defined film-fed growth technique with an (010) principal face. Two crystals with apparently randomly formed high angle grain boundaries (HAGBs) were selected and analyzed by electron backscatter diffraction, electron channeling contrast imaging, and cathodoluminescence to investigate the nature of the LAGBs and the source of the HAGB formation. It was discovered that planar LAGBs lying parallel to the (010) plane exist in the region immediately preceding the start of an HAGB. Increased misorientation across the LAGB was observed, approaching the initiation of a new grain. We present multimodal microscopy characterization, correlating misorientation and variation in optoelectronic properties with LAGBs and the associated dislocations.

14 SOLAR ENERGY↗

Shock induced damage in copper: A before and after, three-dimensional study

We report on the microstructural features associated with the formation of incipient spall and damage in a fully recrystallized, high purity copper sample. Before and after ballistic shock loading, approximately 0.8 mm 3 of the sample's crystal lattice orientation field is mapped using non-destructive near-field High Energy Diffraction Microscopy. Absorption contrast tomography is used to image voids after loading. This non-destructive interrogation of damage initiation allows for novel characterization of spall points vis-a-vis microstructural features and a fully 3D examination of microstructural topology and its influence on incipient damage. The spalled region is registered with and mapped back onto the pre-shock orientation field. As expected, the great majority of voids occur at grain boundaries and higher order microstructural features; however, we find no statistical preference for particular grain boundary types. We note the damaged region contains a large volume of $Σ-3$ (60 degrees < 111 >) connected domains with a large area fraction of incoherent $Σ-3$ boundaries.

36 MATERIALS SCIENCE↗

Unusual crystallization behavior in Ga-Sb phase change alloys

Combined in situ X-ray scattering techniques using synchrotron radiation were applied to investigate the crystallization behavior of Sb-rich Ga-Sb alloys. Measurements of the sheet resistance during heating indicated a reduced crystallization temperature with increased Sb content, which was confirmed by in situ X-ray diffraction. The electrical contrast increased with increasing Sb content and the resistivities in both the amorphous and crystalline phases decreased. It was found that by tuning the composition between Ga:Sb = 9:91 (in at.%) and Ga:Sb = 45:55, the change in mass density upon crystallization changes from an increase in mass density which is typical for most phase change materials to a decrease in mass density. At the composition of Ga:Sb = 30:70, no mass density change is observed which should be very beneficial for phase change random access memory (PCRAM) applications where a change in mass density during cycling is assumed to cause void formation and PCRAM device failure.

36 MATERIALS SCIENCE↗

Crystal structure and magnetic properties of the Ba{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}, Pb{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}, and Pb{sub 3}TeCo{sub 3}V{sub 2}O{sub 14} langasites

We report the structural and magnetic characterizations of Ba{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}, Pb{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}, and Pb{sub 3}TeCo{sub 3}V{sub 2}O{sub 14}, compounds that are based on the mineral dugganite, which is isostructural to langasites. The magnetic part of the structure consists of layers of Co{sup 2+} triangles. Nuclear and magnetic structures were determined through a co-refinement of synchrotron and neutron powder diffraction data. In contrast to the undistorted P321 langasite structure of Ba{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}, a complex structural distortion yielding a large supercell is found for both Pb{sub 3}TeCo{sub 3}P{sub 2}O{sub 14} and Pb{sub 3}TeCo{sub 3}V{sub 2}O{sub 14}. Comparison of the three compounds studied along with the zinc analog Pb{sub 3}TeZn{sub 3}P{sub 2}O{sub 14}, also characterized here, suggests that the distortion is driven by Pb{sup 2+} lone pairs; as such, the Pb compounds crystallize in a pyroelectric space group, P2. Magnetic susceptibility, magnetization, and heat capacity measurements were performed to characterize the magnetic behavior. All three compounds become antiferromagnetic with Néel temperatures T{sub N}≈21 K (Ba{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}), ≈13 K (Pb{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}), and ≈8 K (Pb{sub 3}TeCo{sub 3}V{sub 2}O{sub 14}), and they exhibit magnetic transitions at high applied magnetic fields, suggesting intrinsically complex magnetic behavior for tetrahedrally coordinated d{sup 7} Co{sup 2+} in this structure type. - Graphical abstract: Ba{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}, Pb{sub 3}TeCo{sub 3}P{sub 2}O{sub 14} and Pb{sub 3}TeCo{sub 3}V{sub 2}O{sub 14} exhibit a triangles-of-triangles arrangement of the magnetic cations. Despite the Pb-induced crystallographic distortion, all of these materials exhibit competing antiferromagnetic and ferromagnetic interactions that lead to complex high field magnetism. - Highlights: • Nuclear and magnetic structures of Ba{sub 3}TeCo{sub 3}P{sub 2}O{sub 14}, Pb{sub 3}TeCo{sub 3}P{sub 2}O{sub 14} and Pb{sub 3}TeCo{sub 3}V{sub 2}O{sub 14}. • Structural characterization shows complex Pb-induced distortion. • Distortion puts Pb-compounds into space group that allows potential multiferroicity. • Magnetic characterization shows competing magnetic interactions. • Triangles of triangles motif results in complex high-field magnetic behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the microstructure obtained by the quenching and partitioning process in a low-carbon steel

The 'quenching and partitioning' process is a new heat treatment for the development of multiphase steels with improved mechanical properties. In this work, a partial austenitization followed by Q and P paths, at which the partitioning step is effectuated at a temperature equal to the quenching temperature, has been applied to a low-carbon steel. The resulting multiphase microstructures have been investigated by optical microscopy using bright field and differential interference contrast, electron backscatter diffraction, X-ray diffraction and magnetic measurements. This group of techniques has led to a complete identification of the microstructural constituents: ferrite present during the partial austenitization, epitaxial ferrite formed during cooling, martensite and retained austenite. The analysis of the results has shown a significant relevance of the epitaxial ferrite in the retention of austenite, whereas the carbon partitioning from martensite to austenite has played a minor role.

36 MATERIALS SCIENCE↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Frustration Driven by Itinerancy in Spinel CoV 2 O 4

Localized spins and itinerant electrons rarely coexist in geometrically-frustrated spinel lattices. They exhibit a complex interplay between localized spins and itinerant electrons. In this paper, we study the origin of the unusual spin structure of the spinel CoV 2 O 4 , which stands at the crossover from insulating to itinerant behavior using the first principle calculation and neutron diffraction measurement. In contrast to the expected paramagnetism, localized spins supported by enhanced exchange couplings are frustrated by the effects of delocalized electrons. This frustration produces a non-collinear spin state even without orbital orderings and may be responsible for macroscopic spin-glass behavior. As a result, competing phases can be uncovered by external perturbations such as pressure or magnetic field, which enhances the frustration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nm-scale spatial resolution x-ray imaging with MLL nanofocusing optics: instrumentational requirements and challenges

The Hard X-ray Nanoprobe (HXN) beamline at NSLS-II has been designed and constructed to enable imaging experiments with unprecedented spatial resolution and detection sensitivity. The HXN X-ray Microscope is a key instrument for the beamline, providing a suite of experimental capabilities which includes scanning fluorescence, diffraction, differential phase contrast and ptychography utilizing Multilayer Laue Lenses (MLL) and zoneplate (ZP) as nanofocusing optics. In this paper, we present technical requirements for the MLL-based scanning microscope, outline the development concept and present first ~15 x 15 nm 2 spatial resolution x-ray fluorescence images.

47 OTHER INSTRUMENTATION↗

BERT Non-Destructively Probes the Microstructure of Dissimilar Welds [Poster]

Energy-resolved neutron imaging (ERNI) utilizes contrast provided by diffraction. Microstructure with >100µm grains as in cast, annealed or welded materials is difficult to characterize by X-ray or electron-based methods $\Rightarrow$ Well-suited for neutron Bragg-edge radiography. BERT was applied to dissimilar welds of Inconel on steel produced by additive manufacturing. Viewing the sample at time-of-flight/energy/wavelength where a single grain orientation dominates the attenuation allows to map grain orientations. Similarly to electron-backscatter diffraction (EBSD) but on cm length scales and through-thickness. Combined with texture measurements on the HIPPO instrument, identifying major grain orientations, 2D and 3D grain orientation maps are feasible. Results can guide development of thermo-mechanical treatment avoiding or introducing such microstructures, characterize dissimilar welds, interpretation of acoustic signals for quality control, guide destructive examination with X-rays/electrons, or provide data for codes predicting such microstructures.

36 MATERIALS SCIENCE↗

Microshutter Arrays for the NGST NIRSpec

We are developing a programmable multiobject field selector for the NGST NIRSpec. This device is a microshutter array, a close-packed 2000 x 2000 array of 100 micrometer x 100 micrometer shutters fabricated with Micro-ElectroMechanical Systems (MEMS) technologies. The shutters are opened using a magnet scanned over the array. The shutters are held open by electrostatic potentials on adjacent vertical electrodes. Modeling of the magnetic actuation of the microshutters allowed optimization of the magnetic field configuration, the distance between magnet and shutters, and the force and torque produced by the magnet. The results of laboratory tests are consistent with our modeling. We have demonstrated actuation, latching and addressing. We are able to rotate shutters out of the plane up to 90 degree and more, to latch them electrostatically to the walls and release them selectively. During the last six month all critical elements of the array have been demonstrated. Fabrication processes were developed to deposit vertical electrodes on support grid side walls and insulated light-shields that block the gaps between shutters and the support grid. Physical optics analysis was performed to assess the expected optical performance of the microshutters. A preliminary Fourier optics analysis on the microshutter array performance has been carried out. More detailed analysis of wave propagation through 3D structures is a next step. An optical test station for verifying optical parameters of the shutter array at room temperature has been developed. It allows to measure parameters, such as transmission, scattering, contrast ratio, and diffraction of the array structure. Initial data have been acquired and are being analyzed and compared to theoretical predictions.

Moseley, Harvey↗